DELL N1108T-ON Ethernet Switch User Guide
- June 17, 2024
- Dell
Table of Contents
- Notes, Cautions, and Warnings
- Introduction
- N1108T-ON/N1108P-ON Installation
- Connecting an N1100-ON Series Switch to a Terminal
- Booting the N1100-ON Series Switch
- Dell Easy Setup Wizard Console Example
- NOM Information (Mexico Only)
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Dell Networking
N1108T-ON/N1108P-ON/
N1124T-ON/N1124P-ON/
N1148T-ON/N1148P-ON
Switches
Getting Started Guide
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better
use of your switch.
CAUTION: A CAUTION indicates either potential damage to hardware or loss
of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal
injury, or death.
Lithium battery caution:
- There is a danger of explosion if a battery is incorrectly replaced. Replace only with the same or equivalent type. Dispose batteries of according to the manufacturer’s instructions.
- Disposing a battery into fire, a hot oven, mechanically crushing, or cutting it can result in an explosion.
- Leaving a battery in an extremely hot environment can result in leakage of flammable liquid, gas, or an explosion.
- If a battery is subjected to extremely low air pressure, it may result in leakage of flammable liquid, gas, or an explosion.
- The device can only be used in a fixed location such as a lab or a machine room. When you install the device, ensure that the protective earthing connection of the socket-outlet is verified by a skilled person.
© 2017 Dell Inc. or its subsidiaries. All rights reserved. This product is
protected by U.S. and international copyright and intellectual property laws.
Dell and the Dell logo are trademarks of Dell Inc. in the United States and/or
other jurisdictions. All other marks and names mentioned herein may be
trademarks of their respective companies.
Regulatory Models: E17W and E18W
May 2017 P/N NTHM9 Rev. A00
Introduction
This document provides basic information about the Dell Networking N1100-ON
Series switches, including how to install a switch and perform the initial
configuration. For information about how to configure and monitor switch
features, refer to the User Configuration Guide, which is available on the
Dell Support website at dell.com/support. See the Support website for the
latest updates on documentation and firmware.
NOTE: Switch administrators are strongly advised to maintain Dell
Networking switches on the latest version of the Dell Networking Operating
System (DNOS).
Dell Networking continually improves the features and functions of DNOS based
on feedback from you, the customer. For critical infrastructure, pre-staging
of the new release into a non-critical portion of the network is recommended
to verify network configuration and operation with the new DNOS version.
N1100-ON Series Hardware Overview
This section contains information about device characteristics and modular
hardware configurations for the Dell Networking N1100-ON Series switch.
Power Consumption for N1100-ON Series PoE Switches
Table 1-1 describes the power consumption for N1100-ON Series PoE switches.
The PoE power budget is 60W for the N1108P-ON, 185W for the N1124P-ON, and
370W for the N1148P-ON.
Table 1-1. Power Consumption for N1100-ON Series PoE Switches
Model| Input Voltage| Power Supply
Configuration| Maximum
Steady Current
Consumption (A)| Maximum
Steady
Power (W)
---|---|---|---|---
N1108P-ON| 100V/60Hz| Main PSU| 0.95A| 88.64W
| 110V/60Hz| Main PSU| 0.87A| 88.43W
| 120V/60Hz| Main PSU| 0.80A| 88.22W
| 220V/50Hz| Main PSU| 0.49A| 89.28W
| 240V/50Hz| Main PSU| 0.45A| 89.70W
N1124P-ON| 100V/60Hz| Main PSU| 2.66A| 260.66W
| 110V/60Hz| Main PSU| 2.38A| 257.95W
| 120V/60Hz| Main PSU| 2.16A| 256.27W
| 220V/50Hz| Main PSU| 1.18A| 250.52W
| 240V/50Hz| Main PSU| 1.10A| 251.25W
N1148P-ON| 100V/60Hz| Main PSU| 4.78A| 476.03W
| 110V/60Hz| Main PSU| 4.32A| 472.64W
| 120V/60Hz| Main PSU| 3.95A| 470.58W
| 220V/50Hz| Main PSU| 2.14A| 459.37W
| 240V/50Hz| Main PSU| 1.97A| 459.06W
Ventilation System
One fan cools the N1108T-ON/N1108P-ON switches, and two fans cool the N1024T-
ON/N1024P-ON/N1048T-ON/N1048P-ON switches. The fans are not field replaceable.
N1100-ON Series Model Summary
Table 1-2. N1100-ON Series Switch Regulatory Numbers
Marketing
Model Name
(MMN)| Description| Power Supply
Unit (PSU)| Regulatory
Model Number
(RMN)| Regulatory
Type Number
(RTN)
---|---|---|---|---
N1108T-ON| 10x1G/2x1G SFP Ports| DPS-24GP| E17W| E17W001
N1108P-ON| 10x1G/2x1G SFP/2xPoE+ Ports| DPS-80AP/DPS-24GP| E17W| E17W001
N1124T-ON| 24x1G/4x10G SFP+ Ports| DPS-40AP| E18W| E18W001
N1124P-ON| 24x1G/4x10G SFP+/6xPoE+ Ports| EDPS-250BF| E18W| E18W001
N1148T-ON| 48x1G/4x10G SFP+ Ports| DPS-60AP| E18W| E18W002
N1148P-ON| 48x1G/4x10G SFP+/12xPoE+ Port| YM-2501D| E18W| E18W002
N1108T-ON/N1108P-ON Installation
Rack Mounting an N1108T-ON/N1108P-ON Switch
WARNING: Read the safety information in the Safety and Regulatory Information
as well as the safety information for other switches that connect to or
support the switch.
The AC power connector is on the rear panel of the switch.
Installing in a Rack
WARNING: Do not use rack mounting kits to suspend the switch from under a
table or desk, or attach it to a wall.
CAUTION: Disconnect all cables from the switch before continuing. Remove
all self-adhesive pads from the underside of the switch, if they have been
attached.
CAUTION: When mounting multiple switches into a rack, mount the switches
from the bottom up.
-
Secure the N1108T-ON/N1108P-ON switch in either the Dell Rack Mount Kit as shown in Figure 1-1 or the Dell Tandem Tray Kit as shown in Figure 1-2.
-
Insert the switch into the 48.26 cm (19 inch) rack, ensuring that the rack mounting holes on the kit line up to the mounting holes in the rack.
-
Secure the kit to the rack with either the rack bolts or cage nuts and cagenut bolts with washers (depending on the kind of rack you have). Fasten the bolts on thebottom before fastening the bolts on the top.
N1124T-ON/N1124P-ON/N1148T-ON/N1148P-ON Installation
Rack Mounting an N1124T-ON/N1124P-ON/
N1148T-ON/ N1148P-ON Switch
WARNING: Read the safety information in the Safety and Regulatory
Information as well as the safety information for other switches that connect
to or support the switch.
The AC power connector is on the rear panel of the switch.
Installing in a Rack
WARNING: Do not use rack mounting kits to suspend the switch from under a
table or desk, or attach it to a wall.
CAUTION: Disconnect all cables from the switch before continuing. Remove
all self-adhesive pads from the underside of the switch, if they have been
attached.
CAUTION: When mounting multiple switches into a rack, mount the switches
from the bottom up.
-
Place the supplied rack-mounting bracket on one side of the switch, ensuring that the mounting holes on the switch line up to the mounting holes in the rack-mounting bracket. Figure 1-3 illustrates where to mount the brackets.
-
Insert the supplied bolts into the rack-mounting holes and tighten with a screwdriver.
-
Repeat the process for the rack-mounting bracket on the other side of the switch.
-
Insert the switch into the 48.26 cm (19 inch) rack, ensuring that the rackmounting holes on the bracket line up with the mounting holes in the rack.
-
Secure the bracket to the rack with either the rack bolts or cage nuts and cage-nut bolts with washers (depending on the kind of rack you have). Fasten the bolts on the bottom before fastening the bolts on the top.
CAUTION: Make sure that the supplied rack bolts fit the pre-threaded holes in the rack.
NOTE: Make sure that the ventilation holes are not obstructed.
Wall Installation for N1108T-ON and N1108P-ON
To mount the switch on a wall:
-
Make sure that the mounting location meets the following requirements:
• The surface of the wall must be capable of supporting the switch.
• Allow at least two inches (5.1 cm) space on the sides for proper ventilation and five inches (12.7 cm) at the back for power cable clearance.
• The location must be ventilated to prevent heat buildup. -
Place the supplied wall-mounting bracket on one side of the switch, verifying that the mounting holes on the switch line up to the mounting holes on the wall-mounting bracket.
-
Insert the supplied screws into the wall-mounting bracket holes and tighten with an M5x32 screwdriver.
-
Repeat the process for the wall-mounting bracket on the other side of the switch.
-
Place the switch on the wall in the location where the switch is being installed.
-
On the wall mark the locations where the screws to hold the switch must be prepared.
-
On the marked locations, drill the holes and place all plugs (not provided) in the holes.
-
Secure the switch to the concrete wall or wood material with screws (not provided). Make sure that the ventilation holes are not obstructed.
Installing as a Free-standing Switch
NOTE: Dell strongly recommends mounting the switch in a rack.
Install the switch on a flat surface if you are not installing it in a rack.
The surface must be able to support the weight of the switch and the switch
cables. The switch is supplied with four self-adhesive rubber pads.
- Attach the self-adhesive rubber pads on each location marked on the bottom of the switch.
- Set the switch on a flat surface, and make sure that it has proper ventilation by leaving 5 cm (2 inches) on each side and 13 cm (5 inches) at the back.
Stacking Multiple N1124T-ON/N1124P-ON/N1148T-ON/ N1148P-ON Switches
You can stack N1124T-ON/N1124P-ON/N1148T-ON/ N1148P-ON switches up to four
switches high using 10G SFP+ ports on the front of the switch.
The ports must be configured to support stacking. When multiple switches are
connected together through the stack ports, they operate as a single unit with
up to 208 front-panel ports. The stack operates and is managed as a single
entity. Refer to the User Configuration Guide and the CLI Reference Guide for
more information.
Starting and Configuring the N1100-ON Series Switch
The following flow chart provides an overview of the steps you use to perform
the initial configuration after the switch is unpacked and mounted.
Connecting an N1100-ON Series Switch to a Terminal
After completing all external connections, configure the switch by connecting
it to a terminal.
NOTE: Read the Release Notes for this product before proceeding. You can
download the Release Notes from the Dell Support website at
dell.com/support.
NOTE: Dell recommends that you obtain the most recent version of the user
documentation from the Dell Support website at
dell.com/support.
To monitor and configure the switch via the USB console, use the console port
on the front panel of the switch to connect it to a computer running VT100
terminal emulation software using the supplied USB cable. It may be necessary
to download and install a driver on first use of the USB cable.
The following equipment is required to use the console port:
- VT100-compatible computer with a USB port running VT100 terminal emulation software, such as HyperTerminal® and a USB driver.
- The supplied USB cable with a type B USB connector for the console port and USB connector for the host PC.
Perform the following tasks to connect a terminal to the switch console port:
-
Connect the USB type B connector on the supplied switch and connect the other end to a computer running VT100 terminal emulation software.
-
Configure the terminal emulation software as follows:
a Select the appropriate serial port (for example, COM 1) to connect to the console.
b Set the data rate to 115,200 baud.
c Set the data format to 8 data bits, 1 stop bit, and no parity.
d Set the flow control to none.
e Set the terminal emulation mode to VT100.
f Select Terminal keys for Function, Arrow, and Ctrl keys. Make sure that the setting is for Terminal keys (not Microsoft Windows keys). -
Connect the USB type B connector on the cable directly to the switch console port. The Dell Networking console port is located on the right side of the front panel and is labeled with a |O|O| symbol.
NOTE: Console access to the stack manager is available from any console port via the local CLI. Only one USB console session at a time is supported.
Connecting an N1100-ON Series Switch to a Power Source
CAUTION: Read the safety information in the Safety and Regulatory
Information manual as well as the safety information for other switches that
connect to or support the switch.
The N1100-ON Series models have one internal power supply. The power
receptacle is on the rear panel.
AC and DC Power Connection
-
Make sure that the switch console port is connected to a PC running a VT100 terminal emulator via the USB to USB Type B cable.
-
Using a 5-foot (1.5 m) standard power cable with safety ground connected, connect the power cable to the AC main receptacle located on the rear panel.
The PoE model switches have a heavy-duty power cable with a notched connector for the switch power receptacle. Use of this type of cable is mandatory for PoE-capable switches. -
Connect the power cable to a grounded AC outlet.
Booting the N1100-ON Series Switch
When the power is turned on with the local terminal already connected, the
switch goes through a power-on self-test (POST). POST runs every time the
switch is initialized and checks hardware components to determine if the
switch is fully operational before completely booting. If POST detects a
critical problem, the program flow stops. If POST passes successfully, valid
firmware is loaded into RAM. POST messages are displayed on the terminal and
indicate test success or failure. The boot process runs for approximately 60
seconds.
You can invoke the Boot menu after the first part of the POST is completed.
From the Boot menu, you can perform configuration tasks such as resetting the
system to factory defaults, activating the backup image, or recovering a
password. For more information about the Boot menu functions, refer to the
CLI Reference Guide.
Performing the N1100-ON Series Initial Configuration
The initial configuration procedure is based on the following assumptions:
- The Dell Networking switch was never configured before.
- The Dell Networking switch booted successfully.
- The console connection was established, and the Dell Easy Setup Wizard prompt appears on the screen of a PC running terminal emulation software.
The initial switch configuration is performed through the console port. After
the initial configuration, you can manage the switch from the alreadyconnected
console port or remotely through an interface defined during the initial
configuration.
NOTE: The switch is not configured with a default user name, password, or
IP address.
Before setting up the initial configuration of the switch, obtain the
following information from your network administrator:
- The IP address to be assigned to the management interface.
- The IP subnet mask for the network.
- The IP address of the management interface default gateway.
These settings are necessary to allow the remote management of the switch
through Telnet (Telnet client) or HTTP (Web browser).
Enabling Remote Management
On the N1100-ON Series switches, you can use any of the switch ports on the
front panel for in-band management. By default, all in-band ports are members
of VLAN 1.
The Dell Easy Setup Wizard includes prompts to configure network information
for the VLAN 1 interface on the N1100-ON Series switches. You can assign a
static IP address and subnet mask or enable DHCP and allow a network DHCP
server to assign the information.
Refer to the CLI Reference Guide for commands to configure network
information.
Initial Configuration Procedure
Perform the initial configuration by using the Dell Easy Setup Wizard or by
using the CLI. The wizard automatically starts when the switch configuration
file is empty. Exit the wizard at any point by entering [ctrl+z], but all
configuration settings specified will be discarded, and the switch will use
the default values.
NOTE: If you do not run the Dell Easy Setup Wizard or do not respond to
the initial Easy Setup Wizard prompt within 60 seconds, the switch enters CLI
mode. You must reset the switch with an empty startup configuration in order
to rerun the Dell Easy Setup Wizard.
For more information about performing the initial configuration by using the
CLI, refer to the CLI Reference Guide. This Getting Started Guide shows how to
use the Dell Easy Setup Wizard for initial switch configuration. The wizard
sets up the following configuration on the switch:
- Establishes the initial privileged user account with a valid password. The wizard configures one privileged user account during the setup.
- Enables CLI login and HTTP access to use the local authentication setting only.
- Sets up the IP address for the VLAN 1 routing interface, of which all in-band ports are members.
- Sets up the SNMP community string to be used by the SNMP manager at a given IP address. Skip this step if SNMP management is not used for this switch.
- Allows you to specify the network management system IP address or permit management access from all IP addresses.
- Configures the default gateway IP address for the VLAN 1 interface.
Example Session
This section describes a Dell Easy Setup Wizard session. The following values
are used by the example session:
-
The SNMP community string to be used is public.
-
The network management system (NMS) IP address is 10.1.2.100.
-
The user name is admin, and the password is admin123.
-
The IP address for the VLAN 1 routing interface is 10.1.1.200 with a subnet mask of 255.255.255.0.
-
The default gateway is 10.1.1.1.
The setup wizard configures the initial values as defined above. After completing the wizard, the switch is configured as follows: -
SNMPv2 is enabled and the community string is set up as defined above.
SNMPv3 is disabled by default. -
The admin user account is set up as defined.
-
A network management system is configured. From the management station, you can access the SNMP, HTTP, and CLI interfaces. You may also choose to allow all IP addresses to access these management interfaces by choosing the (0.0.0.0) IP address.
-
An IP address is configured for the VLAN 1 routing interface.
-
A default gateway address is configured.
NOTE: In the following example, the possible user options or default values are enclosed in [ ]. If you presswith no options defined, the default value is accepted. Help text is in parentheses.
Dell Easy Setup Wizard Console Example
The following example contains the sequence of prompts and responses
associated with running an example Dell Easy Setup Wizard session, using the
input values listed earlier.
After the switch completes the POST and is booted, the following dialog
appears:
Unit 1 – Waiting to select management unit)>
___Dell SupportAssist EULA__
I accept the terms of the license agreement. You can reject the license
agreement by configuring this command ‘eula-consent support-assist reject’.
By installing SupportAssist, you allow Dell to save your contact information
(e.g. name, phone number and/or email address) which would be used to provide
technical support for your Dell products and services Dell may use the
information for providing recommendations to improve your IT infrastructure.
Dell SupportAssist also collects and stores machine diagnostic information,
which may include but is not limited to configuration information, user
supplied contact information, names of data volumes, IP addresses, access
control lists, diagnostics & performance information, network configuration
information, host/server configuration & performance information and related
data (Collected Data) and transmits this information to Dell. By downloading
SupportAssist and agreeing to be bound by these terms and the Dell end user
license agreement, available at: http://www.dell.com/aeula, you agree to
allow Dell to provide remote monitoring services of your IT environment and
you give Dell the right to collect the Collected Data in accordance with
Dell’s Privacy Policy, available at:
http://www.dell.com/privacypolicycountryspecific, in order to enable the
performance of all of the various functions of SupportAssist during your
entitlement to receive related repair services from Dell. You further
agree to allow Dell to transmit and store the Collected Data from
SupportAssist in accordance with these terms. You agree that the provision of
SupportAssist may involve international transfers of data from you to Dell
and/or to Dell’s affiliates, subcontractors or business partners. When making
such transfers, Dell shall ensure appropriate protection is in place to
safeguard the Collected Data being transferred in connection with
SupportAssist. If you are downloading SupportAssist on behalf of a company or
other legal entity, you are further certifying to Dell that you have
appropriate authority to provide this consent on behalf of that entity. If you
do not consent to the collection, transmission and/or use of the Collected
Data, you may not download, install or otherwise use SupportAssist.
____AeroHive HiveManager NG EULA____
This switch includes a feature that enables it to work with HiveManager (an
optional management suite), by sending the switch’s service tag number and IP
Address to HiveManager to authenticate your entitlement to use HiveManager. If
you wish to disable this feature, you should run command ‘eula-consent
hiveagent reject’ immediately upon powering up the switch for the first time,
or at any time thereafter.
Applying Global configuration, please wait…
Welcome to Dell Easy Setup Wizard
The setup wizard guides you through the initial switch configuration, and gets
you up and running as quickly as possible. You can skip the setup wizard, and
enter CLI mode to manually configure the switch. You must respond to the next
question to run the setup wizard within 60 seconds, otherwise the system will
continue with normal operation using the default system configuration. Note:
You can exit the setup wizard at any point by entering [ctrl+z].
Would you like to run the setup wizard (you must answer this question within
60 seconds)? [Y/N] y
Step 1:
The system is not set up for SNMP management by default. To manage the switch
using SNMP (required for Dell Network Manager) you can. Set up the initial
SNMP version 2 account now.
Return later and set up other SNMP accounts. (For more information on setting
up an SNMP version 1 or 3 account, see the user documentation).
Would you like to set up the SNMP management interface now? [Y/N] To set up
the SNMP management account you must specify the management system IP address
and the “community string” or password that the particular management system
uses to access the switch. The wizard automatically assigns the highest access
level
[Privilege Level 15] to this account. You can use Dell Network Manager or
other management interfaces to change this setting, and to add additional
management system information later. For more information on adding management
systems, see the user documentation.
To add a management station:
Please enter the SNMP community string to be used.
NOTE: If it is configured, the default access level is set to the highest
available access for the SNMP management interface. Initially only SNMPv2 will
be activated. SNMPv3 is disabled until you return to configure security access
for SNMPv3 (e.g. engine ID, view, etc.).
Please enter the IP address of the Management System (A.B.C.D) or wildcard
(0.0.0.0) to manage from any Management Station. [0.0.0.0]: 10.1.2.100
Step 2:
Now we need to set up your initial privilege (Level 15) user account. This
account is used to login to the CLI and Web interface. You may set up other
accounts and change privilege levels later. For more information on setting up
user accounts and changing privilege levels, see the user documentation.
To set up a user account:
Please enter the user name. [root]:admin
Please enter the user password: ****
Please reenter the user password: ****
Step 3:
Next, an IP address is set up on the VLAN 1 routing interface.
You can use the IP address to access the CLI, Web interface, or SNMP interface
of the switch.
To access the switch through any Management Interface you can
- Set up the IP address for the Management Interface.
- Set up the default gateway if IP address is manually configured on the routing interface.
Step 4:
Would you like to set up the VLAN1 routing interface now? [Y/N] y
Please enter the IP address of the device (A.B.C.D) or enter “DHCP” (without
the quotes) to automatically request an IP address from the network DHCP
server: 10.1.1.200
Please enter the IP subnet mask (A.B.C.D or /nn): 255.255.255.0
Step 5:
Finally, set up the default gateway. Please enter the IP address of the
gateway from which this network is reachable. [0.0.0.0]: 10.1.1.1
This is the configuration information that has been collected:
SNMP Interface = “public”@10.1.2.100
User Account setup = admin
Password = ****
VLAN1 Router Interface IP = 10.1.1.200 255.255.255.0
Default Gateway = 10.1.1.1
Step 6:
If the information is correct, please enter (Y) to save the configuration and
copy the settings to the start-up configuration file. If the information is
incorrect, enter (N) to discard the configuration and restart the wizard:
[Y/N] y
Thank you for using the Dell Easy Setup Wizard. You will now enter CLI mode.
Applying Interface configuration, please wait…
Next Steps
After completing the initial configuration described in this section, connect
any of the front-panel switch ports to a production network for in-band remote
management.
If you specified DHCP for the VLAN 1 management interface IP address, the
interface will acquire its IP address from a DHCP server on the network. To
discover the dynamically assigned IP address, use the console port connection
to issue the following command:
- For the VLAN 1 routing interface, enter show ip interface.
To access the Dell OpenManage Switch Administrator interface, enter the VLAN 1
management interface IP address into the address field of a Web browser. For
remote management access to the CLI, enter the VLAN 1 management interface IP
address into a Telnet or SSH client. Alternatively, continue to use the
console port for local CLI access to the switch.
The N1100-ON Series switches support basic switching features such as VLANs
and spanning tree protocol. Use the Web-based management interface or the CLI
to configure the features your network requires. For information about how to
configure the switch features, refer to the User Configuration Guide or CLI
Reference Guide available on the support site:
dell.com/support.
NOM Information (Mexico Only)
The following information is provided on the device(s) described in this document in compliance with the requirements of the official Mexican standards (NOM):
Exporter:| Dell Inc.
One Dell Way
Round Rock, TX 78682
---|---
Importer:| Dell Computer de México, S.A. de C.V.
Paseo de la Reforma 2620 – 11o Piso
Col. Lomas Altas
11950 México, D.F.
Ship to:| Dell Computer de México, S.A. de C.V.
al Cuidado de Kuehne & Nagel de México S. de R.L.
Avenida Soles No. 55
Col. Peñon de los Baños
15520 México, D.F.
Supply voltage:| Dell Networking N1100-ON Series: 100V–240 VAC
Frequency:| Dell Networking N1100-ON Series: 50–60 Hz
Maximum steady state current consumption:| Dell Networking N1100-ON Series:
• 110V circuit: ~0.43A
• 220V circuit: ~0.21A
Do not use:
• 110V circuit: ~0.43A
• 220V circuit: ~0.21A
NOTE: The current shown here is for a single power
supply consumption.
Printed in the U.S.A.
www.dell.com |
dell.com/support
References
- Computers, Monitors & Technology Solutions | Dell Australia
- End User License Agreement | Dell
- Manual-Hub.com – Free PDF manuals!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>