SILMET Proglass Plus Cem User Manual
- June 17, 2024
- SILMET
Table of Contents
SILMET Proglass Plus Cem
PREPARE RESTORATION
-
STEP 1
Seat the restoration to check occlusion, proper fit, and contact.
Tip: Do not force the restoration into place. -
STEP 2
Sandblast with 30 or 50 microns of aluminum oxide at 2 Bar (30 psi) to create a matte surface -
STEP 3
Clean with alcohol and air dry with oil-free air.
PRETREAT TOOTH
- STEP 4
- Clean prepared tooth.
- Do not over-dry the tooth.
- Over-drying can lead to post operative sensitivity.
Tip: Completely remove any residue (temporary cement, desensitizers, astringents, disinfectants, etc.).
Do not use H202, EDTA or NaHco3.
APPLY CEMENT
-
STEP 5
For Dispenser Delivery:
Squeeze a small amount of ProGlass Plus Cem from the syringe to ensure even dispensing.
For Automix Delivery:
Dispense a small amount of cement onto the mix pad to ensure a perfect mix. Discard this material. -
STEP 6
For Dispenser Delivery:
Apply a thin layer of cement to the inside surface of the restoration, with a spatula.
For Automix Delivery:
Dispense cement directly into the crown.
SEAT AND CLEAN UP
- STEP 7
Firmly seat the crown with finger pressure.
STEP 8
Excess cement can be removed 2 minutes after seating the restoration or after tack light curing 3 seconds per surface.
Tip: Do not exceed the recommended tack cure time, Otherwise, clean-up will be difficult.
Remove excess cement with a scaler while holding the crown it place.
FINISH
-
STEP 9
Light cure (≥ 400mW/cm2) for an additional 20 seconds per surface. ProGlass Plus Cem set time is ≤5 minutes after placement in the mouth. -
STEP 10
Finish restoration and adjust occlusion.
STORE CEMENT
- STEP 11
For Dispenser Delivery:
Wipe the dispenser barrels independently to avoid contamination of the material and premature setting ensure that the cap is put firmly in place.
For Automix Delivery:
Store with the original sealing cap in place.
Tip: To prevent premature curing and drying of the paste, be sure to follow the recommended cleaning and storage steps.
Ideal storage is normal ambient room temperature of 5-24°C / 41-75.2°F.