SILMET Proglass Plus Cem User Manual

June 17, 2024
SILMET

SILMET Proglass Plus Cem

SILMET-Proglass-Plus-Cem-PRODUCT

PREPARE RESTORATION

  • STEP 1
    Seat the restoration to check occlusion, proper fit, and contact.
    Tip: Do not force the restoration into place.

  • STEP 2
    Sandblast with 30 or 50 microns of aluminum oxide at 2 Bar (30 psi) to create a matte surface

  • STEP 3
    Clean with alcohol and air dry with oil-free air.

SILMET-Proglass-Plus-Cem-FIG-1

PRETREAT TOOTH

  • STEP 4
    • Clean prepared tooth.
    • Do not over-dry the tooth.
    • Over-drying can lead to post operative sensitivity.
      Tip: Completely remove any residue (temporary cement, desensitizers, astringents, disinfectants, etc.).
      Do not use H202, EDTA or NaHco3.

APPLY CEMENT

  • STEP 5
    For Dispenser Delivery:
    Squeeze a small amount of ProGlass Plus Cem from the syringe to ensure even dispensing.
    For Automix Delivery:
    Dispense a small amount of cement onto the mix pad to ensure a perfect mix. Discard this material.

  • STEP 6
    For Dispenser Delivery:
    Apply a thin layer of cement to the inside surface of the restoration, with a spatula.
    For Automix Delivery:
    Dispense cement directly into the crown.

SILMET-Proglass-Plus-Cem-FIG-3

SEAT AND CLEAN UP

  • STEP 7
    Firmly seat the crown with finger pressure.
    STEP 8
    Excess cement can be removed 2 minutes after seating the restoration or after tack light curing 3 seconds per surface.
    Tip: Do not exceed the recommended tack cure time, Otherwise, clean-up will be difficult.
    Remove excess cement with a scaler while holding the crown it place.

SILMET-Proglass-Plus-Cem-FIG-4

FINISH

  • STEP 9
    Light cure (≥ 400mW/cm2) for an additional 20 seconds per surface. ProGlass Plus Cem set time is ≤5 minutes after placement in the mouth.

  • STEP 10
    Finish restoration and adjust occlusion.

STORE CEMENT

  • STEP 11
    For Dispenser Delivery:
    Wipe the dispenser barrels independently to avoid contamination of the material and premature setting ensure that the cap is put firmly in place.
    For Automix Delivery:
    Store with the original sealing cap in place.
    Tip: To prevent premature curing and drying of the paste, be sure to follow the recommended cleaning and storage steps.
    Ideal storage is normal ambient room temperature of 5-24°C / 41-75.2°F.
    For further reference, please refer to Instructions for Use.

SILMET-Proglass-Plus-Cem-FIG-6

12 Hassadna st., Or-Yehuda, 6022011, Israel
Tel: +972-3-7353000
info@silmet.co.il
www.silmetdental.com