hygger HG105 DC Frequency Water Pump User Manual
- June 17, 2024
- hygger
Table of Contents
HG105 USER MANUAL
hygger DC frequency water pump
HG105 DC Frequency Water Pump
WARNINGS:
-
Please use the adapter and related accessories.
-
Do not put the pump in the flammable, explosive and corrosive liquid.
-
Do not use the pump in the water temperature above 35°C(95°F ).
Maximum water depth is 1.5M(4.9ft). -
Do notimmerse the plug in water or other liquid.
Do not allow children or the inexperienced to operate the product alone without safety precautions.
PRODUCT FEATURES:
- Visual LCD display with 4 water circulation modes, power feeder function and DC safety voltage usage
- Bottom suction water intake, low water level operation
- Sine wave technology, ultra-quiet, IC electronic detection
- No water dry running and locked rotor protection
- Mini size, elegant appearance
- Suitable for use in seawater and freshwater.
PRODUCT SPECIFICATION:
Model | HG105-1500 | HG105-2500 | HG105-3500 |
---|---|---|---|
Voltage | DC 24V | ||
Power | 20W | 30W | 35W |
Flow Rate | 396GPH | ||
(1500L) | 660GPH | ||
(2500L) | 925GPH |
(3500L)
Head Max| 6.6ft (2m)| 9.8ft (3m)| 11.5ft (3.5m)
US standard outlet nozzle| 3/4″| 3/4″| 1″
1″| 1-1/4″
5/8″| Straight
nozzle:3/4″| Straight
nozzle:1″
Screw cap
:G 3/4″| Screw cap
:G 1-1/8″| Screw cap
:G 1-3/8″
EU/UK standard outlet nozzle| 19mm| 29mm| 25mm
25mm| 31.5mm
15.9mm
outer:31mm
inner:25mm| outer:38mm
inner:32mm
26.9mm
37mm| 44.7mm
OPERATING INSTRUCTION:
CONTROLLER FEATURE:
MAINTANCE AND CAUTION:
When using the pump, please pay attention to the position of the pump. Please connect the pump supply after installation. If the pump fails to pump out water the first time, this may be caused by the airin the pump body. Please try unplugging and replugging to vent the air. To ensure safety, please install an earth leakage switch with a leakage current of less than 30mA when using outdoor (the earth leakage switch shall be installed by the user).
- Always disconnect the pump from the power supply before cleaning, maintenance and handling.
- Try to avoid the pump dry running.
- Do not lift the pump by just holding the power cord, in case the cable connections inside the pump become disconnected.
- Do not use the pump in heated liquids.
- The pump can’t be used in the swimming pool.
- This product has multiple protection functions. When entering the protection state, unplug the power supply and then plug it back in to restore the pump to normal operation.
TROUBLE SHOOTING:
Error code | Fault | Solution |
---|---|---|
Er01 | Controller over current | Abnormality working current, check if the pump |
is or the controller is damaged
Er02| Controller over temperature| Check that the controller is not exposed to
the sunlight
or high temperature environment
Er03| The pump is idling| The pump is idling, check if the pump is dry
heating.
The pump must be filled with water before running
Er04| The pump is blocked| Currently the impeller is out of operation. Clean
the pump and impeller to ensure the impeller is clean and working properly
Er05| Controller over voltage| Check the input supply voltage
Controller under voltage
DISPOSAL
Do not dispose of this product as unsorted municipal waste.
Collection of such waste separately for special treatment is necessary. This
product has to be disposed of at an authorized place for the recycling of
electrical and electronic appliances rather than being disposed of together
with the domestic waste. Collecting and recycling waste is a way of saving
natural resources. So, please consult with your local seller to make sure the
product is disposed of in an environmentally friendly way.
PACKING LIST
Model | HG105-1500 | HG105-2500 | HG105-3500 |
---|---|---|---|
Water pump | √ | √ | √ |
DC adapter | √ | √ | √ |
LCD controller with holder | √ | √ | √ |
User manual | √ | √ | √ |
Nozzle | 5/8″x1PC | ||
3/4″x1PC | 3/4″x1PC | ||
1″x1PC | 1″x1PC |
1-1/4″x1PC
Straight nozzle| /| 3/4″x1PC| 1″x1PC
Screw cap| G 3/4″x 1 PC| G 1-1 /8″x 1 PC| G 1-3/8″x 1 PC
Rubber pad| 1PC| 1PC| 1PC
User manual| 1PC| 1PC| 1PC
CONTACT INFORMATION
Distributed by:Hygger Aquarium, Inc.
13941 Magnolia Ave, Chino, CA91710
Contact us at www.hygger-online.com
Email:mago@hygger-online.com
Trademarks of Shenzhen Mago Trading Co.,Ltd
Bantian Group Business Center,Longgang, Shenzhen City, China
All Rights Reserved
Made in China
E-CrossStu GmbH
Mainzer Landstr.69, Frankfurt am Main, Baden-Wiirttemberg, 60329,Germany
E-CrossStu@web.de
+49 69332967674|
YH Consulting Limited
C/0 YH Consulting Limited
Office 147,Centurion House, London Road,
Staines—upon —Thames,Surrey, TW18 4AX,London
H2YHUK@gmail.com
+44 07514-677868
---|---
MADE IN CHINA
Documents / Resources
|
hygger HG105 DC Frequency Water
Pump
[pdf] User Manual
HG105 DC Frequency Water Pump, HG105, DC Frequency Water Pump, Frequency Water
Pump, Water Pump, Pump
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>