RFC – RF Cylinder Thermostat
Operating Instructions
RFC-RF RF Room Cylinder Thermostat
CAUTION!
Only qualified electricians or authorised service staff are permitted to open
the thermostat.
Ensure that this wireless enabled thermostat is installed 1 metre from any
metalic object, television, radio or wireless internet transmitter.
Factory default settings
Temperature indicator: °C
Switching differential: 2.5°C
In built frost protection: 5°C
Keypad lock: Off
Specifications & wiring
Power Supply: | 2 x AAA Alkaline Battery |
---|---|
Power consumption: | 50 uA |
Battery replacement: | Once per year |
Temp. Control Range: | 10…90°C |
Dimensions: | 84 84 30mm |
Temp. sensor: | NTC 10K Ohm @ 25°C – 1.5m probe type |
Temp. indication: | °C |
a Mounting of temperature sensor
ON CYLINDER: To ensure accurate control of your cylinder, the temperature
sensor should be mounted on the bottom 1/3 of the cylinder. It is essential
that the sensing element is in direct contact with the cylinder and that there
is no insulation between it and the cylinder. 60°C is the temperature level
required in order to prevent the build up of legionella bacteria. The
temperature sensor can be fixed to the cylinder using the provided foil tape.
ON PIPEWORK: To ensure accurate control, the temperature sensor should be
mounted on the pipework as tightly as possible. It is essential that the
sensing element is in direct contact with the pipework and that there is no
insulation between it and the pipework. The temperature sensor can be fixed to
the pipework using the provided foil tape. !
b Mounting of thermostat
The thermostat should be mounted in a position that will make reading the
display conventient.
The thermostat can be fitted to:
- Recessed conduit boxes
- Surface mounting boxes
- Directly on walls !
Installation
Press the button on the bottom of the thermostat.
The front housing will detach from the baseplate.
Insert the batteries (provided) into the thermostat.
Mount the unit as described in section 3. Ensure the cable sensor is connected
to terminals Con 3 and Con 4.
Offer the baseplate up to the thermostat. Snap it into position to close.
Button / symbol description
Resetting the thermostat
Press the button on the bottom of the thermostat, the front housing will
detach from the baseplate.
Insert the batteries into the thermostat.
Press the reset button on the PCB, ‘NO’ will flash on the screen.
Rotate the hand wheel clockwise until ‘YES’ appears on the screen.
Press the hand wheel once to confirm the setting.
The thermostat has now been reset and the current temperature will appear on
the screen.
Boost function
Press the boost button once, twice or three times to boost the heating for 1,
2 or 3 hours respectively. +1H, +2H or +3H will appear on the screen.
The boost function will override the programmer if the programmer is timed to
be Off.
Lock function
To lock the thermostat, press the hand wheel for 10 seconds. The keypad symbol
will appear on the screen.
To unlock the thermostat, press the hand wheel for 10 seconds. The keypad
symbol will disappear from the screen.
To connect the RF thermostat with the programmer
Lower the cover on the front of the time switch / programmer. Move the selector switch to the RUN position.
On the timeswitch / programmer, press the button for 5 seconds.
Wireless Connect will appear on the screen.
On the RFR wireless room thermostat or RFC wireless cylinder thermostat, press
the Code button. This is located inside the housing on the Printed Circuit
Board.
On the timeswitch / programmer, the available zones will begin to flash. Press
the button for the zone you wish to connect the thermostat to.
The wireless symbol appears on the screen.
The thermostat will count upwards to the number of the zone that it is paired
with. When it reaches the number of the zone that it is paired with press the
hand wheel on the thermostat.
The timeswitch / programmer is now operating in the wireless mode.
The temperature of the wireless thermostat is now displayed on the programmer.
Repeat this process for the second, third and fourth zone if required.
To disconnect the RF thermostat with the programmer
Lower the cover on the front of the timeswitch / programmer. Move the selector switch to the RUN position.
On the timeswtich/ programmer, press the ) button for 5 seconds.
This will take you into the Wireless Connect screen.
Press the button for 3 seconds.
This will clear all RF connections thereby disconnecting all thermostats from
the timeswitch / programmer.
Press the button.
EPH Controls Ireland
Sitecast Industrial Estate, Pouladuff, Cork, T12 W665, Ireland
sales@ephcontrols.com
www.ephcontrols.com
EPH Controls UK
Unit E4, Welland Business Park, Valley Way, Market Harborough,
Leicestershire, LE16 7PS, United Kingdom
sales@ephcontrols.co.uk
www.ephcontrols.co.uk
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>