Entel RP500 Series Professional Compact Repeater Base Station User Guide

May 15, 2024
Entel

User Guide – RP500 Series
Professional compact repeater base station
v10/10
Common Information RP510/520/580/580-U

Introduction

This guide covers the ‘basics’ of your base station operation. To meet your exact requirements the radio may have been customised by your Entel authorised dealer. These features will be explained in a separate guide issued by the dealer.

Certification

Declaration of Conformity
We Entel UK Limited of:
320 Centennial Avenue Centennial Park
Elstree
Borehamwood Hertfordshire WD6 3TJ
United Kingdom
Declares under our sole responsibility that the product range: RP500 Series Base Station Transceiver
Conforms to the following standards or other nominative documents:

  • EN 300 086-2 V1.2.1, EN 301 489-1 V1.8.1: 2008-04, EN 301 489-5 V1.3.1: 2002-08,
    EN 60950-1:2006, in accordance with Directive 99/5/EC.

Serial Number ____

Entel RP500 Series Professional Compact Repeater Base Station -
Certification 1

Radio Care

Warranty
The RP5XX comes with a 12 month warranty, for details see our full terms & conditions.

Advice

  • Do not use options or accessories not specified by Entel
  • Ensure that the radio is used within the parameters for which it was designed
  • Keep dry, do not use in high humidity areas

Warning

  • Disconnect from the mains before fitting any accessories or removing any cover

Do not install the transceiver in the following locations:

  • In explosive atmospheres (flammable gas, dust including metallic & grain powders etc)
  • Near explosives or blasting sites

Caution

  • Do not disassemble or modify the transceiver for any reason
  • Do not transmit without an antenna fitted, be aware the base station will automatically transmit when talk-through is enabled
  • Do not transmit while touching the antenna terminal or any exposed metallic parts of the aerial as this may result in a burn
  • Do not obstruct the fan/vents
  • Always replace fuses with the same rating. Never fit a fuse of a higher rating. Replace the fuse only after investigating and correcting the cause of the blown fuse

End of Life Disposal

  • When your Entel transceiver reaches the end of its useful life, please ensure that the unit is disposed of in an environmentally friendly way.
    For country specific information please see www.entel.co.uk/recycling/index.htm.

Packing list

  • RP5xx Base Station Transceiver
  • Mains IEC power lead
  • UG500 User guide

Optional Accessories

Power Options

CNB500 Internal rechargeable lithium ion battery
RP5DCL External DC cable for connection to external battery

Hardware Options

RPBRAK Wall mount installation bracket
MPX70 Internally mounted UHF duplexer for single antenna operation
MPX26 Internally mounted VHF High Band duplexer for single antenna operation
DPF4/6 Externally mounted VHF Mid Band duplexer for single antenna operation
RPSCR Voice scrambler

Audio Accessory Options

CMP550 Heavy duty speaker microphone
DMP550 Desk microphone
DMP550BT Desk microphone with bluetooth

Preparing the base station for use

Before use check the following:
The external antenna connection is correctly fitted to the base station before it is switched on.
Dependent upon configuration either one or both ‘N Type’ sockets may be used. Check with your dealer.
The antenna plug must be screwed fully on to the socket. Failure to attach the antenna correctly can lead to poor performance and damage the unit.

Turn the base station on/off
When powered from the mains, use the rear mounted isolator switch to power the base.
To turn the base on/off turn the front mounted on/off volume control clockwise.

Receiving calls on the base station
Calls can be monitored on the base station utilising the internal loudspeaker. Use the on/off volume control to set a comfortable listening volume.

Attaching / Removing an optional local control microphone
Calls can be made from the base station using one of the Entel approved microphone options.
To insert the optional local control microphone, ensure that the plug with the locking nib is uppermost and push the plug in to the socket until it clicks in to place. To remove the plug, push down the nib on the plug and pull out.

Talk Through enable/disable
Talk Through facility can be enabled or disabled from the front of the base station. To enable press the talk through button and the LED will illuminate to show the feature is active. To disable press the talk through button again (the LED will extinguish)

RP500

Standard Features:

  • Single channel
  • Transmit power output 5 Watts VHF, 4 Watts UHF, 1 Watt low power
  • 100% duty cycle
  • CTCSS & DCS (Analogue & Digital squelch) with squelch tail elimination
  • Second receiver (for country specific licensing requirements)
  • Dealer adjustable transmit tail with pip tones
  • Exceptionally loud and clear audio
  • Talk through on / off button
  • Local control with optional microphone
  • Mains failure alert indicates when optional back-up battery is in use

Dealer fit options:

  • Voice scrambler (when local control is required on an encrypted system)
  • Internal Duplexer for single antenna operation (external on RP510)
  • Internal 3.6AH Lithium Ion battery

Entel RP500 Series Professional Compact Repeater Base Station - Preparing
1

Controls & Indicators

Entel RP500 Series Professional Compact Repeater Base Station - Controls &
Indicators 1

  1. On / Off Volume control – Rotate clockwise to turn on and increase volume, anticlockwise to decrease and turn off.
  2. Talk Through switch – Press to select / deselect talk through
  3. Transmit LED – will illuminate red when the base is transmitting
  4. Talk Through LED – will illuminate white when talk through is enabled
  5. Internal loudspeaker – to monitor transmissions through the base station
  6. Receive signal LED – will illuminate green when a transmission is being received
  7. Power LED – will illuminate blue when the base is switched on
  8. Microphone socket – Insert optional microphone to enable local control use

Entel RP500 Series Professional Compact Repeater Base Station - Controls &
Indicators 2

  1. Mains input – 110-240 IEC mains power input socket
  2. Mains fuse – 3.15A 20mm mains protection fuse
  3. External 13.8VDC input – to provide an external source to power the base station
  4. Antenna sockets – One or both sockets may be used dependant upon configuration
  5. Extractor fan – Dealer configurable, continuous – temperature – or transmit operation
  6. External 13.8VDC fuse – External power input 3A DC protection fuse
  7. Earth stud
  8. On / Off switch – AC mains power switch

Feature Operation

12V Operation
There are 2 methods to operate your base station from 12VDC.

External back-up battery
Using the optional RP5DCL lead, an external 12V lead acid back-up battery can be connected. The base station will float charge the battery whilst powered from a mains source.
The maximum charge current the base will deliver is 3A.

Internal Lithium Ion battery option
A dealer fit 3.6AH lithium Ion rechargeable battery can be fitted. Whilst powered from the mains, the base station will charge the internal battery.

Mains Failure / 12V Operation Warning
If an optional mains failure back-up battery is fitted or if base is only powered from 12V battery then a low level pip tone will sound on all transmissions to alert users that the base station is not mains powered. (This feature is dealer programmable and can be disabled).

Talk Through & Local Control
The base station has a front mounted talk through on/off button. When talk through is on, this will allow users to communicate using the base as a relay. Turning talk through off will prevent users talking to each other and will only allow communication to the base. Using an optional microphone allows the base to be used as an additional radio.

Cooling Fan
The rear mounted cooling fan has 3 dealer configurable operating modes.

  1. Fan operates continuous while base is switched on
  2. Fan operates only when base is transmitting
  3. Fan disabled.

Transmit Tail & Pip Tones
When used in talk through, the base station has an adjustable transmit tail length, dealer adjustable between 3-46 seconds. The transmit tail will keep the base station on transmit for the pre-set time after a radio user has ended their transmission. To indicate the transmit tail to all users on the radio system the base will generate pip tones for the duration of the transmit tail. If you transmit during the transmit tail, the pip tones will stop and your transmission will be heard.

Dual Receiver
Your base station is fitted with two receivers. Where country licensing dictates, the second receiver will be used to monitor for transmissions on the base stations transmit channel.
If a signal is detected on this channel the base will be prevented from transmitting. The second receiver cannot be used to monitor transmissions, it is used only to lock out the transmitter function.

Troubleshooting Guide

PROBLEM PROBABLE CAUSE SOLUTION
Radios cannot talk to each other through the base station Talk Through is
switched off Turn Talk Through on using button on front panel of base

station.
I am operating on batteries and the range has suddenly dropped| The base has automatically switched to low power as the batteries are getting low| Recharge battery / plug in to mains supply if available
The base station does not transmit and talk through is switched on| The base has the dual receiver active| Wait for a short period and try again
The base station is pipping when in use| This is a mains failure alert to indicate that the base is operating from a battery| The alert will end when the base is powered from the mains
Radio emits screeching noise.| A channel has been selected which has not been programmed by your dealer with a suitable frequency.| Check that you have not accidentally switched to an unused channel & select a programmed channel.

Notes
Use this page to record important information, such as the serial number of your repeater, and any private channels programmed by your dealer.

‘the professional’s choice’

AT
BE
BG
CY
CZ
DK
EE
FI| FR
DE
GR
HU
IS
IE
IT
LV| LT
LU
MT
NL
NO
PL
PT
RO| SK
SI
ES
SE
CH
UK
---|---|---|---

Copyright Entel UK Ltd. 2009

0891
Registered Community Design Application 000810890
U.S. Design Patent Pending No. 23/182,829
Copyright and Unregistered Design Right Entel UK 2009
All rights reserved
Headquarters: United Kingdom www.entel.co.uk
https://manual-hub.com/

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals