FrSky R9M 900MHz Long Range RC System Instruction Manual
- June 17, 2024
- Frsky
Table of Contents
FrSky R9M 900MHz Long Range RC System
Introduction
Thank you for purchasing FrSky R9M telemetry module. As the first Frsky long- range system works in 868MHz, it offers two modes by way of adapting to different flight situations. To fully enjoy the benefits of this system, please read the instruction manual carefully and set up the device as described below
Overview
- If the module is connected to both an external power and a transmitter, it will automatically be powered by the one with a higher voltage.
- 3s Li-Battery is not recommended as an external power supply, or it may be damaged.
Specifications
- Vin Voltage Range: DC 4V~12.6V
- External Power Supply: 4V~12V (2s Li-Battery is recommended )
- Telemetry Interface: Smart Port
- Upgrade Interface: Smart Port
- Modulations: PXX or CPPM (auto-detected)
- RF Operating Frequency: 868MHz
About the output power and operating current:
EUVe.-.ion | Range Check | |
---|---|---|
RFPo-r | 25mW | 500mW |
I
Operating voltage /current| CIV/180mA| 10V/100mA|
12V/273mA| 12V/193mA| BV/BUmA 10V/42mA
Numbers of Channel| SCH| 16CH| 16CH| I
comparably| R9 series| I
Smart Port (S. Port) is a signal wire full duplex digital transmission interface developed by FrSky Electronic Co., Ltd. All products enabled with Smart Port (including XJT module, Rx8R receiver, new hub-less sensors, new Smart Dashboard, etc), serial port user data and other user input/output devices can be connected without limitations for numbers or sequences at a high transmission speed.
Features
- Long range, low latency and high precision RC system
- Telemetry (25mW) /No Telemetry (500mW/200mW) mode
- Smart Port enabled and support telemetry data transmission
Binding Procedure
Binding is the process of uniquely associating a receiver to a transmitter RF module. A transmitter external RF module can be bound to multiple receivers (not to be used simultaneously). A receiver can only be bound to one RF module.
In R9M mode
-
Put the transmitter RF module into binding mode
-
For Taranis Series transmitters, turn on the transmitter, go to MENU MODEL SETUP- PAGE 2, choose External RF Mode
R9M EU, and select BIND (Open TX2.2.1 and its improved versions are strongly recommended). -
For Horus Series transmitters, turn on the transmitter, go to RF SYSTEM, choose External RF (ON), and select BIND.
-
Connect the battery to the receiver while holding the Bind button on the receiver. The RED LED on the receiver will flash, indicating the binding process is completed.
-
Reboot the receiver and switch the RF module back to the normal mode. The flashing of the GREEN LED on the receiver indicates the receiver is receiving commands from the transmitter.
In PPM mode
- Select No Telemetry or Telemetry mode, then power on R9M while holding its F/S button, Green LED will be on and Red LED will be flashing.
- Connect the battery to the receiver while holding its Bind button. The Red LED on it will flash, indicating the binding process in completed.
- Reboot the R9M and the receiver. The flashing of the GREEN LED on the receiver indicates it is receiving commands from the transmitter.
Note : After binding procedure is completed, resupply the power and check if the receiver is truly communicating with the transmitter.
Note: After binding procedure is completed, resupply the power and check if the receiver is truly communicating with the transmitter.
How to switch Telemetry (25mW) or No Telemetry (500mW / 200mW)
- For Taranis Series transmitters, turn on the transmitter, go to the MENU-MODEL SETUP-PAGE2.
- Turn off Internal RF, choose External RF MODE R9M/LBT (EU), and select BIND to set the mode.
- For Horus Series transmitters, turn on the transmitter, go to the RF SYSTEM, choose External RF and R9M, then select with Tele or no Tele.
- For PPM mode: switch the mode through switches 1&2 ahead of binding, Press the F/S button, and blink times of RED& GREEN LED indicating the corresponding power.
Switch 1 | Switch 2 | Status | LED Blink (Times) |
---|
OFF
| ON| Telemetry mode (25mW, 8CH output)| Once (Green)
OFF| Telemetry mode (25mW, 16CH output)| Twice (Green)
ON
| ON| No telemetry mode (200mW)| Twice
(Green&Red)
OFF| No telemetry mode (500mW)| Three times
(Green&Red)
Note:
- The 2 modes both conform to the CE standard.
- The receiver should be rebound after switching the modes between Telemetry (25mW) and No Telemetry (200mW/500mW).
How to enable/disable the S.Port of R9M
- For Taranis X9D/X9D Plus and Taranis Q X7/X7S, If you want to turn on the S.Port of R9M, turn off the Internal RF.
- For Horus X12S/X10/X10S, turn on the transmitter. go to the RF SYSTEM, choose the External RF select the R9M, and select the S.Port or not.
Note : If S.Port is disabled, communication-related to S. Port between R9M and the transmitter will be cut off.
Range Check
A pre-flight range check should be done before each flying session. Reflections from nearby metal fences, concrete buildings or trees can cause loss of signal both during range check and during the flight. Under Range Check Mode, the RF power would decrease and Range distance will reduce to 1/30–1/10 that of the Normal Model.
- Place the model at least 60cm (two feet) above non-metal contaminated ground (e.g. on a wooden bench). The receiver antenna should be in a vertical position.
- For Taranis X9D/X9D Plus/X9E and Taranis Q X7/X7S, turn on the transmitter and the receiver, go to: MODEL SETUP/External RF/ Mode R9M/Range.
- For Horus X12S/X10/X10S, turn on the transmitter and the receiver, go to: MDL/RF SYSTEM/External RF (ON)/ STATE (RANGE).
- For PPM mode: Shorten TX&RX, power on R9M again.
How to Set Failsafe mode (on the transmitter)
There are 3 failsafe modes: No Pulse, Hold, Custom
- No Pulse: on loss of signal the receiver produces no pulses on any channel. To use this type, select it in the menu and wait 9 seconds for the failsafe to take effect.
- Hold: the model will maintain the last position after the signal is lost. To use this type, select it in the menu and wait 9 seconds for the failsafe to take effect.
- Custom: the customized position of each channel. The model will move to the pre-set position after the signal is lost. Move the cursor to “Set” and press ENTER, you will see FAILSAFE SETTING screen below. Move the cursor to the channel you want to set failsafe on, and press ENTER. When moving the corresponding sticks or switches, you will see the channel bar moving. Move the channel bar to the place you want for the failsafe and long press ENTER to finish the setting. Wait 9 seconds before the failsafe takes effect.
Note : If the failsafe is not set, the model will hold the last position after the signal is lost, thus it may fly away or cause injury.
For more information please refer to the introduction manual for the
transmitter.
FrSky is continuously adding features and improvements to our products. To get
the most from your product, please check the download section of the FrSky
website www.frsky-rc.com for the latest updated
firmware and manuals
FrSky Electronic Co., Ltd
wwww.frsky-rc.com Contact us: frsky@frsky-
rc.com.
Add:F-4, Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125,
Jiangsu, China Technical Support:
salestech@gmail.com
References