GREISINGER GNS-SCV-Z Capacitive Level Sensor Designed Instruction Manual

June 17, 2024
GREISINGER

**GREISINGER GNS-SCV-Z Capacitive Level Sensor Designed Instruction Manual

**

General Note

Read this document carefully and get used to the operation of the device before you use it. Keep this document within easy reach near the device for consulting in case of doubt. Mounting, start-up, operating, maintenance and removing from operation must be done by qualified, specially trained staff that have carefully read and understood this manual before starting any work.
The manufacturer will assume no liability or warranty in case of usage for other purpose than the intended one, ignoring this manual, operating by unqualified staff as well as unauthorized modifications to the device.
The manufacturer is not liable for any costs or damages incurred at the user or third parties because of the usage or application of this device, in particular in case of improper use of the device, misuse or malfunction of the connection or of the device.
The manufacturer is not liable for misprints

Safety

Intended Use

GNS-SCV is a capacitive level switch to offer a control of filling levels in liquids.
GNS-SCV-W: designed for use with water and conductive liquids.
GNS-SCV-Z: designed for use with oil and non-conductive liquids.

Safety signs and symbols

Warnings are labelled in this document with the followings signs:

Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance.
Attention! This symbol warns of possible dangers or dangerous situations which can provoke damage to the device or environment at non-observance.
NoteNote! This symbol point out processes which can indirectly influence operation or provoke unforeseen reactions at nonobservance.

Safety guidelines

However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device.

  1. Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under “Specification”. If the device is transported from a cold to a warm environment condensation may cause in a failure of the function. In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start-up.
  2. **** If there is a risk whatsoever involved in running it, the device has to be switched off immediately and to be marked accordingly to avoid re-starting. Operator safety may be a risk if.
    • – there is visible damage to the device.
    • the device is not working as specified.
    • the device has been stored under unsuitable conditions for a longer time. In case of doubt, please return device to manufacturer for repair or maintenance.
  3. **** Do not use these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in death or serious injury and material damage.
  4. **** This device must not be used at potentially explosive areas! The usage of this device at potentially explosive areas increases danger of deflagration, explosion or fire due to sparking

Product Specification

Scope of supply

  • GNS-SCV
  • Operating Manual

3.2 Operation advice
The GNS-SCV level switch has been designed to offer a very simple and safety control levels in
liquids. The GNS-SCV is, dependent on the version, suitable for various materials.

  • Water, conductive liquids (GNS-SCV-W)
  • Oil, non-conductive liquids (GNS-SCV-Z)
  • Solids in the form of powder and granules

Mounting and Maintenance
Take care to use metal hexagonal part of the body during connection to the adapters

Dimensions and Connections

Dimensions [mm] SW A B L0 L1 F
24 74 10 50 40 ± 2 ¼ ” NPT
Dimensions and Connections

Reshipment and Disposal

Reshipment

**** All devices returned to the manufacturer have to be free of any residual of measuring media and/or other hazardous substances. Measuring residuals at housing or sensor may be a risk for persons or environment.
Note Use an adequate transport package for reshipment, especially for fully functional devices. Please make sure that the device is protected in the package by enough packing materials

Disposal
The device must not be disposed in the unsorted municipal waste! Send the device directly to us (sufficiently stamped), if it should be disposed. We will dispose the device appropriate and environmentally sound

Specification

Body Brass
Process connection G ¼ ” NPT, Brass
Electrode Cu-Zn
Electrode-coating PTFE
Length of the electrode 50 mm
Max. medium temperature 30 … +125°C
Max. pressure 25 bar
Power Supply 12 … 35V DC / 5 mA
Wiring Angel plug (EN 175301-803/A)
Output NPN, make contact
Contact rating Max. 3W
Switching delay 4 sec.
Switching delay 4 sec. Switching point Vertical Horizontal 40mm ± 2 mm On

axis of GNS-SCV