GREISINGER 100 T-Logg USB Level Converter Instruction Manual

June 17, 2024
GREISINGER

GREISINGER 100 T-Logg USB Level Converter

GREISINGER-100-T-Logg-USB-Level-Converter-PRODUCT

Product Information

Specifications

  • Model: S58.0.01.6C-03
  • Product Name: T-Logg USB level converter
  • Interface: USB
  • Contact Information: +49 (0) 9402 / 9383-0,  info@greisinger.de.

Intended Use

The T-Logg USB level converter allows for the connection of the T-Logg module to the USB interface of your PC. It is primarily used for the following applications:

  • Exchange data capture
  • Configuration of the T-Logg function
  • Readout measuring data storage
  • And more

General Advice

Before using the device, it is recommended to read through the installation and operating manual attentively and familiarize yourself with the operation of the device. Keep the manual easily accessible for future reference.

Safety Instructions

This device has been designed and tested to meet safety regulations for electronic measuring devices. To ensure faultless operation and reliability, please consider the following safety measures:

  1. Faultless operation and reliability can only be assured if the device is used within the specified climatic conditions mentioned in the specifications section.
  2. Mishandling of the interface adapter may result in damage to the device or any attached devices. The manufacturer does not assume any warranty for damages caused by the use of the interface adapter.
  3. Observe standard regulations for the operation and safety of electrical, light, and heavy current equipment, with particular attention to national safety regulations.
  4. When connecting the device to other devices, ensure thorough interconnection to avoid undesired voltage potentials.
  5. In case of obvious malfunctions, such as visible damage or non-functioning of the device, store the device under appropriate conditions and contact the manufacturer for repair or servicing.

Product Usage Instructions

System Requirements

To successfully use the T-Logg USB-level converter, ensure that your system meets the following requirements:

  • No specific system requirements are mentioned in the manual.

Disposal Notes

Properly dispose of the T-Logg USB level converter according to local regulations. Do not dispose of it with regular household waste.

FAQ

  • Q: How to check whether the adaptor has been installed correctly and via which COM-port can I approach the installed adaptor?
  • A: To check if the adaptor has been installed correctly and determine the COM-port, follow these steps:
  • (Instructions for checking the adaptor installation and COM-port are not provided in the manual.)
  • Q: How to change the COM-port of the adaptor?
  • A: To change the COM-port of the adaptor, follow these steps:
  • (Instructions for changing the COM-port are not provided in the manual.)
  • Q: How to find out the used version of the driver?
  • A: To find out the used version of the driver, follow these steps:
  • (Instructions for finding the driver version are not provided in the manual.)

Intended use

The level converter enables the connection of the T-Logg module to the USB interface of your PC.

  • Applications:
  • Exchange data capture
  • Configuration of the T-Logg function
  • Readout measuring data storage etc.

General advice
Read through this document attentively and make yourself familiar with the operation of the device before you use it. Keep this document in a ready-to- hand way to be able to look up in case of doubt.

Safety instructions

This device was designed and tested considering the safety regulations for electronic measuring devices.
Faultless operation and reliability in the operation of the measuring device can only be assured if the General Safety Measures and the device’s specific safety regulations mentioned in this user’s manual are considered.

  1. Faultless operation and reliability in the operation of the measuring device can only be assured if the device is used within the climatic conditions specified in the chapter “Specifications“.

  2. By faulty handling of the interface adapter damage of the device cannot be excluded. Likewise, damage to your attached device is possible.
    In such a case, we cannot assume any warranty.
    The manufacturer will not assume any warranty for damages to other devices resulting from the use of the interface adapter.

  3. Standard regulations for operation and safety for electrical, light and heavy current equipment have to be observed, with particular attention paid to the national safety regulations.

  4. When connecting the device to other devices (e.g. the PC) the interconnection has to be designed most thoroughly, as internal connections in third-party devices (e.g. connection of ground with protective earth) may lead to undesired voltage potentials.

  5. The device must be switched off and must be marked against use again, in case of obvious malfunctions of the device which are e.g.:
    visible damage
    no pre-scripted working of the device
    storing the device under inappropriate conditions for a longer time
    When not sure, the device should be sent to the manufacturer for repair or servicing.

  6. Attention: Do not use this product as safety or emergency stopping device or in any other application where failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in serious injury and material damage.

Installation

  • For installation of the device drivers a user account with an administrator-authorisation is required.
  • If you haven’t an appropriate authorisation please consult your system administrator.
  • If you already have a device installed with the same USB-Chipset the adaptor will be installed automatically, if not the system will request you to install the driver.
  • If the adaptor is correctly installed on the system you have, for application with our software, a new additional COM-Port is available.

Specification

Connection

  • PC: Standard USB-plug connector (type A)
  • EASYBus: connection jack M8 (3-pin) for direct connection of a T-Logg
  • Power Supply: via USB interface
  • Operating temperature: 0 … +50 °C
  • Storage temperature: -25 … +70 °C
  • Cable length: 1 m
  • Weight: 40 g

EMC
The device corresponds to the essential protection ratings established in the Regulations of the
Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility (2004/108/EG).
Under EN 61326:1997 + A1:1998 + A2:2001 (appendix B, class B).

System requirements

  • 1.0 GHz Dual Core Processor or higher
  • Operating system: Windows XP, Windows Vista, Windows 7, Windows 8, Windows 8.1,
  • Windows Server 2003, Windows 2008, Windows 2008 R2, (note: not suitable for Windows RT)
  • free USB port.

Disposal notes

  • The device must not be disposed of in the regular domestic waste.
  • Send the device directly to us (sufficiently stamped), if it should be disposed of.
  • We will dispose of the device appropriate and environmentally sound.

Frequently Asked Questions

  • How to check whether the adaptor has been installed correctly and via which COMport can I approach the installed adaptor?
  • Start the Device-Manager and open the submenu “Ports (COM & LPT)” If the installation was successful, there will be the entry “USB Serial Port (COMx)”, in which the x after the Com indicates the available COM-port (i.e. COM4).
  • Note: The adaptor will not be shown in the device manager if it is not connected to the PC. If the entry is occupied by an exclamation mark or the entry is not there, then the driver has not been installed correctly.
  • How to change the COM-port of the adaptor?
  • Make sure that the adaptor is connected, start the Device Manager and open the submenu “Ports (COM & LPT)”
  • If the installation is successful, there will be the entry “USB Serial Port (COMx)”, in which the x after the Com indicates the available COM-port (i.e. COM 4).
  • Open the features of this connection by a double-click, go to “Port Settings” and then click there the button “Advanced…”.
  • There you can choose the preferred COM-Port at the point “COM Port Number”. If this port is already reserved for another (even not connected) device, an error message will appear:
  • “In principle, 2 devices may be set on the same COM-port, but then you have to take care, that not both devices are connected at the same time because this would lead to a conflict!“
  • How to find out the used version of the driver?
  • Make sure that the adaptor is connected and start the Device-Manager start \ settings \ control panel \ performance and maintenance \ system \ hardware).
  • For the COM-driver open the submenu “Ports (COM & LPT)”, and open the features for this connection “USB Serial Port (COMx)” by double-clicking and changing them to “Driver”.
  • There you can see the currently used driver version.

GREISINGER-100-T-Logg-USB-Level-Converter-FIG-2

CONTACT

  • GHM Messtechnik GmbH • Standort Greisinger
  • Hans-Sachs-Str. 26 • D-93128 Regenstauf
  • +49 (0) 9402 / 9383-0  +49 (0) 9402 / 9383-33  info@greisinger.de.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GREISINGER User Manuals

Related Manuals