Haier ADH071M1ERG Duct Type Air Conditioner Instruction Manual
- June 17, 2024
- Haier
Table of Contents
- ADH071M1ERG Duct Type Air Conditioner
- Specifications
- Product Usage Instructions
- Cautions
- Safety Precautions
- Parts and Functions
- Heating Mode
- Care and Maintenance
- Troubleshooting
- Accessories
- Precaution for Installation
- Is The Unit Installed Correctly
- Installation Procedure
- FAQ
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ADH071M1ERG Duct Type Air Conditioner
Specifications
-
Model Numbers: ADH071M1ERG, ADH071M3ERG, ADH090M1ERG,
ADH105M1ERG, ADH125M1ERG, ADH140M1ERG, ADH105H1ERG, ADH125H1ERG,
ADH140H1ERG, ADH160H1ERG -
Installation and servicing must be done by qualified
personnel -
Refrigerant Type: R410A
-
Global Warming Potential (GWP): 2088
-
Air Conditioner Working Temperature: Cooling – 10~43 degrees
Celsius, Heating -15~24 degrees Celsius
Product Usage Instructions
Cautions
Before disposing of the old air conditioner, ensure it is
inoperative and safe. Unplug the air conditioner to avoid the risk
of child entrapment.
All packaging materials can be safely disposed of without
harming the environment. The cardboard box can be broken or cut
into smaller pieces and given to a waste paper disposal service.
The wrapping bag and foam pads contain no fluorochloric
hydrocarbon.
Safety Precautions
To avoid hazards, follow these safety precautions:
-
Only use the product as intended and specified in the
manual. -
Do not allow children to operate or play with the
appliance. -
If the supply cord is damaged, it must be replaced by the
manufacturer or a qualified person. -
This appliance is not intended for use by persons with reduced
physical, sensory, or mental capabilities unless supervised or
instructed by a responsible person. -
Do not operate the appliance with an external timer or separate
remote-control system. -
Keep the appliance and its cord out of reach of children under
8 years old. -
The A-weighted sound pressure level is below 70 dB.
-
This appliance is intended for expert or trained users in
shops, light industry, farms, or commercial use by lay
persons.
Parts and Functions
The air conditioner has the following parts and functions:
-
Display panel: Shows current settings and temperature.
-
Power button: Turns the air conditioner on and off.
-
Mode selection: Allows you to switch between cooling and
heating modes. -
Temperature control: Adjusts the desired temperature.
-
Fan speed control: Sets the fan speed to low, medium, or
high. -
Timer function: Allows you to set a specific time for the air
conditioner to turn on or off.
Heating Mode
To use the air conditioner in heating mode, follow these
steps:
-
Ensure the air conditioner is plugged into a power source.
-
Press the power button to turn on the air conditioner.
-
Select the heating mode using the mode selection button.
-
Adjust the temperature using the temperature control
button. -
Set the desired fan speed using the fan speed control
button. -
If desired, use the timer function to schedule the air
conditioner’s operation.
Care and Maintenance
To keep your air conditioner in optimal condition, follow these
care and maintenance instructions:
-
Regularly clean the air filters to remove dust and debris.
-
Check the outdoor unit for any obstructions or debris and
remove if necessary. -
Inspect the power cord for any damage and replace if
needed. -
Keep the air conditioner’s vents and grilles free from dirt and
dust. -
If the air conditioner is not in use for an extended period,
unplug it from the power source.
Troubleshooting
If you encounter any issues with the air conditioner, refer to
the troubleshooting section of the manual for possible
solutions.
Accessories
The air conditioner may come with additional accessories. Refer
to the accessories section in the manual for more information.
Precaution for Installation
Before installing the air conditioner, ensure you follow these
precautions:
-
Read the installation manual carefully before proceeding.
-
Ensure the unit is installed correctly by qualified
personnel. -
Do not vent the refrigerant into the atmosphere; it contains
fluorinated greenhouse gases covered by the Kyoto Protocol. -
Fill in the factory refrigerant charge and additional
refrigerant amount charged in the field using indelible ink.
Is The Unit Installed Correctly
To verify if the unit is installed correctly, refer to the
installation manual and check for proper installation procedures
and guidelines.
Installation Procedure
To install the air conditioner, follow these steps:
- Read the installation manual thoroughly.
- Gather all necessary tools and materials.
- Select a suitable location for installation.
- Ensure proper electrical connections are made.
- Securely mount the indoor and outdoor units as instructed.
- Connect the refrigerant lines and drain pipes.
- Test the air conditioner to ensure it is functioning
correctly.
FAQ
-
1. Q: Can children operate the air conditioner?
A: No, the appliance should not be operated or played with by
children. It can only be used by children aged 8 years and above
under supervision.
-
1. Q: Can the air conditioner be operated with an external
timer?
A: No, the appliance is not intended to be operated by means of
an external timer or separate remote-control system.
-
1. Q: What is the working temperature range of the air
conditioner?
A: The air conditioner can cool within a temperature range of 10
to 43 degrees Celsius and heat within a range of -15 to 24 degrees
Celsius.
DUCT TYPE AIR CONDITIONER OPERATION MANUAL AND INSTALLATION MANUAL
English
ADH071M1ERG ADH071M3ERG ADH090M1ERG
ADH105M1ERG ADH125M1ERG ADH140M1ERG
Contents
Cautions
3
Safety Precautions
4
Parts and Functions
7
Heating Mode
8
Care and Maintenance
9
Troubleshooting
10
Accessories
12
Precaution for Installation
13
Is The Unit Installed Correctly
14
Installation Procedure
15
ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG
No. 0150519050
This product must only be installed or serviced by qualified personnel. Please
read this manual carefully before installation. Keep this operation manual for
future reference.
Original instructions
Haier Industrial Park,Qianwangang Road,Eco-Tech Development Zone,Qingdao 266555,Shandong,P.R.C.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this symbol.This means that
electrical and electronic products shall not be mixed with unsorted household
waste.Do not try to dismantle the system yourself:the dismantling of the air
conditioning system,treatment of the refrigerant,of oil and of other part must
be done by a qualified installer in accordance with relevant local and
national legislation.Air conditioners must be treated at a specialized
treatment facility for reuse, recycling and recovery.By ensuring this product
is disposed of correctly,you will help to prevent potential negative
consequences for the environment and human health.Please contact the installer
or local authority for more information. Battery must be removed from the
remote controller and disposed of separately in accordance with relevant local
and national legislation.
IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
A
R410A
kg B
kg C
kg D
This product contains fluorinated greenhouse gases covered by the Kyoto
Protocol.Do not vent into the atmosphere. Refrigerant type:R410A GWP:2088
GWP=global warming potential Please fill in with indelible ink,
1 the factory refrigerant charge of the product 2 the additional refrigerant
amount charged in the field
and 1+2 the total refrigerant charge on the refrigerant charge label supplied
with the product. The filled out label must be adhered in the proximity of the
product charging port(e.g.onto the inside of the stop value cover). A contains
fluorinated greenhouse gases covered by the Kyoto Protocol B factory
refrigerant charge of the product:see unit name plate C additional refrigerant
amount charged in the field D total refrigerant charge E outdoor unit F
refrigerant cylinder and manifold for charging
WARNING
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in
order to avoid a hazard.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the
appliance. This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
The appliances are not intended to be operated by means of an external timer
or separate remote-control system. Keep the appliance and its cord out of
reach of children less than 8 years. The A-weighted sound pressure level is
below 70 dB. This appliance is intended to be used by expert or trained users
in shops, in light industry and on farms, or for commercial
use by lay persons
Air conditioner working temperature: cooling 10~43 degree, heating -15~24
degree.
2
Cautions
Disposal of the old air conditioner Before disposing an old air conditioner
that goes out of use, please make sure it’s inoperative and safe. Unplug the
air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which
require specialized waste disposal. The valuable materials contained in a air
conditioner can be recycled. Contact your local waste disposal center for
proper disposal of an old air conditioner and contact your local authority or
your dealer if you have any question. Please ensure that the pipework of your
air conditioner does not get damaged prior to being picked up by the relevant
waste disposal center, and contribute to environmental awareness by insisting
on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner All the packaging
materials employed in the package of your new air conditioner may be disposed
without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a
waste paper disposal service. The wrapping bag made of polyethylene and the
polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and
used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials
collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings Before starting the air conditioner, read the
information given in the User’s Guide carefully. The User’s Guide contains
very important observations relating to the assembly, operation and
maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise
due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt,
consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the
relative instructions set forth in the User’s Guide.
Installation shall be done by professional people, don’t install unit by
yourself.
For the purpose of safety, the air conditioner must be properly grounded in
accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill.
Never unplug your air conditioner by pulling on the power cord. Always grip
plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians.
Inadequate repairs may result in a major source of danger for the user of the
air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by
piercing or perforating the air conditioner’s tubes with sharp or pointed
items, crushing or twisting any tubes, or scraping the coatings off the
surfaces. If the refrigerant spurts out and gets into eyes, it may result in
serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not
put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should
children be allowed to sit on the outdoor unit.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
3
Safety Precautions
Before starting to use the system, read carefully this “SAFETY PRECAUTIONS” to ensure a proper operation of the system. Safety precautions described here are classified to ” WARNING” and ” CAUTION”. Precautions which are shown in the column of ” WANING” means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions are shown in the column of ” CAUTION”, a very serious problem could occur depending on situation. Make sure to observe these safety precautions faithfully because they are very important information to ensure the safety. Symbols which appear frequently in the text have following meanings.
Strictly prohibited.
Observe instructions faithfully.
Provide a positive grounding.
When you have read through the manual, keep it always at hand for read consultation. If the operator is replaced, make sure to hand over this manual to the new operator.
CAUTIONS FOR INSTALLATION
WARNING
The system should be applied to places as office, The system should be installed by your dealer or When you need some optional devices such as a
restaurant, residence and the like.
a professional installer.
humidifier, electric heater, etc., be sure to use the products
which are recommended by us. These devices should
be attached by a professional installer.
Application to inferior environment such as an engineering shop, could cause equipment malfunction and serious injury or death.
Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.
Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.
CAUTION
Do not install nearby the place where may have Depending on the place of installation, a circuit
leakage of flammable gas.
breaker may be necessary.
ON
Drain pipe should be arranged to provide a positive draining.
OFF
If the gas leaks and gathers around, it may cause Unless the circuit breaker is installed, it could cause If the pipe is arranged improperly, furniture or the
the fire.
electrical shocks.
likes may be damaged by leaked water.
Where strong winds may prevail, the system Install on the place where can endure the weight Make sure the system is grounded. should be fixed securely to prevent a collapse. of air conditioner.
Bodily injury could result by a collapse.
Bodily injury could result by a careless installation.
Grounding cable should never be connected to a gas pipe, city water pipe, lightning conductor rod or grounding cable of telephone. If the grounding cable is not set properly, it could cause electric shocks.
CAUTIONS FOR TRANSFER OR REPAIR
WARNING
Modification of the system is strictly prohibited. When the system needs a When the air conditioner is relocated, contact your dealer or a professional
repair, consult your dealer.
installer.
Improper practice of repair could cause water leakage, electric shock or Improper practice of installation could cause water leakage, electric shock
fire.
or fire.
4
Safety Precautions
CAUTIONS FOR OPERATION
WARNING
You should refrain from exposing your body directly to cool wind for a long time.
Do not poke the air inlet or outlet with a bar, etc.
When any abnormal condition (scorching smell or others) is found, stop the operation immediately and turn off the power switch. Then consult your dealer.
It could affect your physical condition or cause Since the internal fan is operating with a high
some health problems.
speed, it could cause an injury.
CAUTION
The system should never be used for any other purposes than intended such as for preservation of food, flora and fauna, precision devices or work of art.
Do not handle switches with a wet hand.
If you continue the operation without removing the cause, it could result in a
trouble, electric shock or fire.
Combustion apparatus should not be placed allowing a direct exposure to wind
of air conditioner.
It could cause deterioration of food or other problems.
Do not wash the air conditioner with water.
It could cause electric shocks.
Incomplete combustion could occur on the apparatus.
Do not install the system where the air outlet Make sure to use a fuse of proper electric rating. reaches directly the flora and fauna.
It could cause electric shocks.
Neither stand on the air conditioner nor place something on it.
It will not be good for their health.
Use of steel or copper wire in place of a fuse is strictly prohibited because it could result in a trouble or fire accident.
It is strictly prohibited to place a container of
Do not operate the system while the air outlet grill
combustible gas or liquid near the air conditioner is removed.
or to spray it directly with the gas or liquid.
There are risks of falling or injury by collapsed It could cause a fire accident. object.
There is a risk of injury.
Do not use the power switch to turn on or off the Do not touch the air outlet section while the swing Do not use such equipment as a water heater, etc.
system.
louver is operating.
around the indoor unit or the wire controller.
ON
OFF
It could cause a fire or water leakage.
There is a risk of injury.
If the system is operated at the vicinity of such equipment which generates steam, condensed water may drip during cooling operation or it could cause a fault current or short-circuit.
When operating the system simultaneously with Check occasionally the support structure of the When cleaning the system, stop the operation and
a combustion apparatus, indoor air must be unit for any damage after a use of long period of turn off the power switch.
ventilated frequently.
time.
Insufficient ventilation could cause an oxygen If the structure is not repaired immediately, the Cleaning should never be done while the internal
deficiency accident.
unit could topple down to cause a personal injury. fans are running with high speed.
Do not put water containers on the unit such as a flower vase, etc.
If the water enters into the unit and damages the electric insulation material, it may cause electric shock.
5
Safety Precautions
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Cooling
Indoor temperature Outdoor temperature
max. DB/WB min. DB/WB
max. DB/WB min. DB/WB
Indoor temperature
max. DB/WB min. DB/WB
32/23 C 18/14 C
43/26 C 10/6 C
27 C 15 C
Heating
max. DB/WB
Outdoor temperature min. DB/WB
24/18 C -15 C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on the indoor PC board is broken please change it with the type of T 3.15A /250V(For ADH105,
ADH125,ADH140M1ERG);or the type T5A /250V(For ADH071M1ERG,ADH071M3ERG,ADH090M1ERG).T8A/250V(For ADH105/125/140/160H1ERG)
4. The wiring method should be in line with the local wiring standard.
5. The power cable should be:
H05RN-F 3G 4.0mm2 (outdoor unit 1UH071/090/105N1ERG),
or H05RN-F 3G 6.0mm2 (outdoor unit 1UH125/140/160P1ERG),
or H05RN-F 5G 4.0mm2 (outdoor unit 1UH125/140P1EK);
The connecting cable should be:
H05RN-F4G 2.5mm2;
All the cables shall have got the European authentication certificate. During installation, when the connecting cables
break off, it must be assured that the grounding wire is the last one to be broken off.
6. The power cable and connect cable should be self-provided.
7. The breaker of the air conditioner should be all-pole switch, and the distance between its two contacts should be no
less than 3mm.
8. The indoor unit installation height is at least 2.5m.
9. A leakage breaker must be installed.
10.1 FOR ADH071M1ERG, ADH090M1ERG, we can get the 4 different ESP through adjust the indoor unit PCB SW1-4
and SW1-5, please refer below:
SW1 (1) (2) (3) (4) (5) (6) (7) (8) Static pressure
– – – OFF OFF – – –
10 Pa
– – – OFF ON – – –
30 Pa
– – – ON OFF – – –
50 Pa
– – – ON ON – – –
70 Pa
Attention:
Cut off the power supply to adjust the SW1-4, and SW1-5, or else the operation is invalid.
10.2 For ADH071M3ERG, ADH105M1ERG, ADH125M1ERG, ADH140M1ERG, ADH105H1ERG, ADH125H1ERG,
ADH140H1ERG,ADH160H1ERG,static pressure selection need achieved by wired controller, refer wired controller’s manual
to get details
External static pressure (pa)
Static pressure level ( N) ADH071M3ERG
1
25
ADH105M1ERG ADH125M1ERG ADH140M1ERG
30
ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG
40
2
37
40
50
3
50
50
60
4
70
60
80
5
90
70
100
6
100
80
120
7
110
90
150
8
120
100
180
9
130
110
200
10
150
120
250
For AD105/125/140M1ERG,ADH071M3ERG,ADH105/125/140/160H1ERG,static pressure
level selection can also be achieved by Infrared remote controller,method is:
Step a: set the Infrared remote controller at condition:FAN mode,fan speed
high. Step b:then aim the remote controller at the infrared remote receiver
RE-02,press HEALTH button 4+N times(1 N
10,integer) within 12 seconds,then the receiver will beep N+1 times,the static
pressure level N is been set successfully. Note:For Infrared remote controller
YR-HBS01, need press ON/OFF button make the controller’s at OFF status
first,then open the button cover press FRESH button will enter FAN mode
interface.
6
Parts and Functions
ADH071M1ERG ADH071M3ERG ADH090M1ERG
Air outlet frame
Electrical components Case
Drain pan Evaporator
The pump drain opening
ADH105M1ERG ADH125M1ERG ADH140M1ERG
Air outlet frame
Electrical components Case
Drain pan
Evaporator
The pump drain opening
ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG Air outlet frame
Drain pan
Fan
The drain opening
Electrical components Case
7
Heating Mode
“HOT KEEP” function “HOT KEEP” is operated in the following cases.
When heating is started: In order to prevent blowing out of cool wind, the
indoor unit fan stopped according to the room temperature which heating
operation is started. Wait for approx. 2 to 3 minute, and the operation will
be automatically changed to the ordinary heating mode. Defrosting operation
(in the heating mode): When it is liable to frost, the heating operation is
stopped automatically for 5 to 12 minutes once per approx. one hour, and
defrosting is operated. After defrosting is completed, operation mode is
automatically changed to ordinary heating operation. When the room thermostat
is actuated: When room temperature increases and room temperature controller
actuates, the fan speed is automatically changed to stop under low temperature
condition of indoor heat exchanger. When room temperature decreases, air
conditioner automatically changes over to ordinary heating operation.
Warming operation Heat pump type warming With the heat pump type warming, the
mechanism of heat pump that concentrate heat of outdoor air with the help of
refrigerant to warm the indoor space, is utilized. Defrosting operation When a
room is warmed with a heat pump type air conditioner, frost accumulates on the
heat exchanger of outdoor unit along with the drop of indoor temperature.
Since the accumulated frost reduces the effect of warming, it is necessary to
automatically switch the operation to the defrosting mode. During the
defrosting operation, heating operation is interrupted. Atmospheric
temperature and warming capacity Warming capacity of heat pump type air
conditioner decreases along with the drop of outdoor temperature. When the
warming capacity is not sufficient, it is recommended to use another heating
implement. Period of warm-up Since the heat pump type air conditioner employs
a method to circulate warm winds to warm the entire space of a room, it takes
time before the room temperature rises. It is recommendable to start the
operation a little earlier in a very cold morning.
8
Care and Maintenance
Turn off the power supply switch.
ON OFF
Points to observe Do not touch with wet hand.
Do not use hot water or volatile liquid.
Thinner
Do not use!
Benzine Tooth powder
CAUTION Do not open the inlet grill until fan stops completely. Fan will continue rotating for a while by the law of inertia after operation is being stopped.
Cleaning the air filter 1.Clean the air filter by lightly tapping it or with
the cleaner. It is more effective to clean
the air filter with water. If the air filter is very dirty, dissolve neutral
detergent in the lukewarm water (approx. 30 C), rinse the air filter in the
water, and thoroughly wash the air filter off the detergent in the plain
water. 2.After drying the air filter, set it up on the air conditioner.
CAUTION Do not dry the air filter with fire. Do not run the air conditioner
without the air filter.
Care and Cleaning of the unit Clean with soft and dry cloth. If it is very
dirty, dissolve neutral detergent in the lukewarm water and make the cloth wet
with the water. After wiping, clean off the detergent using clean water.
Post-Season Care Operate the unit with FAN mode on a fair day for about half a
day to dry the inside of the unit well. Stop operation and turn off the power
supply switch. Electric power is consumed even the air conditioner is in stop.
Clean the air filter and set it in the place.
Pre-Season Care See that there are no obstacles blocking the air inlet and air
outlet of both indoor and outdoor units. Make sure that the air filter is not
dirty. Cut in the power supply switch 12 hours before starting run.
9
Troubleshooting
Please check the following things about your air conditioner before making a service call. Unit fails to start
Is the power source switch Is city supply power in
adjust cut in?
normal?
ON
OFF
Power supply switch is not ON.
Power stoppage?
Isn’t the signal receiving section exposed to the direct sunlight or strong illumination?
Isn’t the earth leakage breaker in action? It is dangerous. Turn off the power supply switch immediately and contact the sales dealer.
Cooling or heating is not sufficient
Is the thermostat adjust as Isn’t the air filter dirty? required?
Isn’t any doors or windows left open?
Isn’t the swing louver horizontal? (At HEATING mode) If swing louver is horizontal, the blow wind does not reach floor.
Doesn’t any obstacle exist at the air inlet or outlet?
Cooling is not sufficient
Isn’t sun-shine invading direct? Isn’t any unexpected heating Isn’t the room much crowded? The wind does not blow during
load generated?
heating operation
Isn’t it warming up?
When the air conditioner does not operate properly after you have checked the above mentioned items or when the following phenomenon is observed, stop the operation of the air conditioner and contact your sales dealer.
The fuse or breaker often shuts down. Water drops off during cooling operation. There is a irregularity in operation or abnormal sound is audible.
The followings are not malfunction Water flowing sound is heard.
When the air conditioner is started, when the compressor starts or stops
during operation or when the air conditioner is stopped, it sometimes sounds
“shuru shuru” or “gobo gobo”. It is the flowing sound of the refrigerant, and it
is not a trouble.
SShhuururu
Cracking sound is heard. It smells.
This is caused by heat expansion or contraction of plastics.
Air which blows out from the indoor unit sometimes smells. The smell results
from residents of tobacco smoke or cosmetics stuck inside of unit.
During operation, white fog comes out of indoor unit.
It is switched into the FAN mode during cooling.
When the air conditioner is used at restaurant etc. where dense edible oil
fume is always exists, white fog sometimes blows out of air outlet during
operation. In this case consult sales dealer for cleaning the heat exchanger.
To prevent frost from being accumulated on the indoor unit heat exchanger, it
is sometimes automatically switched to the FAN mode,but it will soon return to
the cooling mode.
The air conditioner can not be restarted soon after it stops.
Unit does not start
Even if the operation switch is turned on, cooling, dehumidifying or heating
is not operable for three minutes after the conditioner is stopped. Because
the protecting circuit is activated. (During this time air conditioner operates
in fan mode.)
Wait for
three
minutes
Air does not blow or the fan speed can When it is excessively cooled during dehumidifying, the blower not be changed during dehumidifying. automatically repeats reducing and lowering the fan speed.
During operation, operation mode has changed over automatically.
Isn’t the AUTO mode selected? In the case of AUTO mode, operation mode is changed automatically from cooling to heating or vise-versa according to the room temperature.
Water or steam generates from the outdoor This results when frost accumulated on the outdoor unit is removed (during
unit during heating.
defrosting operation).
10
Troubleshooting
INDOOR UNIT TROUBLE SHOOTING
LED flash times of indoor PCB
LED4
LED3
0
1
0
2
0
4
0
7
0
8
0
12
0
13
Wired controller display
01 02 04
07
/
0C
0D
Contents of Malfunction
Possible reasons
Malfunction of indoor unit Sensor disconected,or broken, or at ambient temperature sensor wrong position,or short circuit
Malfunction of indoor unit Sensor disconected,or broken,or at piping temperature sensor wrong position,or short circuit
EEPROM wrong of indoor EEPROM chip disconected or broken
PCB
or wrong programmed, or PCB broken
Abnormal communication between indoor and outdoor units
Wrong connection,or the wires be disconected or wrong address setting of indoor unit or faulty power supply or PCB hardware malfunction
Abnormal communication Wrong connection or wired controller between wired controller and broken,or PCB hardware malfunction indoor unit
Malfunction of drain system
Pump motor disconnected or at wrong position,or the float switch disconnected, or at wrong position,or the short circuit bridge disconnected
Zero cross signal wrong
Zero cross signal detected wrong
Abnormal communication communication wire disconnected or
0
14
0E
between main control PCB & wrong connected or PCB hardware
fan motor driver
malfunction
0
15
0F
Fan motor overcurrent
Fan motor current too high
0
17
11
DC voltage high or low
DC voltage of the fan motor driver too high or too low
0
18
12
F.M.D temperature high
Fan motor driver over 95 C
0
19
13
Fan motor out of step
Wrong rotor location detected
M( 1)
N( 0)
/
Error of the outdoor unit
See note 1,2
Note:
1.The outdoor failure can also be indicated by the indoor unit,the checking
method as follows: outdoor unit error code=(M 10+N)-20.LED4 flash M times and
LED3 flash N times . 2.To get much more details about the out door unit
failure,please refer to the outdoor unit trouble shooting list.
11
Accessories
Accessories supplied with the indoor unit:
No.
Name of parts
Quantity
Note
1 Signal line
Connection between the wired remote
1
control and electric control board
2 Wired controller
1 For Air conditioner operation
3 3/8″ Brass nut (liquid side) 4 5/8″ Brass nut (gas side) 5 Coupler heat insulation(gas side)
1 For tightening the Connecting pipe
1
1 For indoor side pipe joint(gas side)
6 Coupler heat insulation(liquid side) 1 For indoor side pipe joint(liquid side)
7 Drain pipe 8 Instructions 9 Cable tie(Large) 10 Cable tie(small)
1
Drainage fittings group
(For ADHM series only)
1 Air conditioner operation
7
For fixing the heat insulation
(For ADHH series only)
For fixing the remote controller cable and 4 connecting cable
(For ADHH series only)
Shape
12
Precaution for Installation
Please read these “Safety Precautions” first and then accurately execute the
installation work. Though the precautionary points indicated herein are
divided under two headings, WARNING and CAUTION, those points which are
related to the strong possibility of an installation done in error resulting
in death or serious injury are listed in the WARNING section. However, there
is also a possibility of serious consequences in relationship to the points
listed in the CAUTION section as well. In either case, important safety
related information is indicated, so by all means, properly observe all that
is mentioned. After completing the installation, along with confirming that no
abnormalities were seen from the operation tests, please explain operating
methods as well as maintenance methods to the user (customer) of this
equipment, based on the owner’s manual. Moreover, ask the customer to keep
this sheet together with the owner’s manual.
WARNING
This system should be applied to places as office, restaurant, residence and
the like. Application to inferior environment such as engineering shop could
cause equipment malfunction. Please entrust installation to either the company
which sold you the equipment or to a professional contractor. Defects from
improper installations can be the cause of water leakage, electric shocks and
fires. Execute the installation accurately, based on following the
installation manual. Again, improper installations can result in water
leakage, electric shocks and fires. When a large air-conditioning system is
installed to a small room, it is necessary to have a prior planned
countermeasure for the rare case of a refrigerant leakage, to prevent the
exceeding of threshold concentration. In regards to preparing this
countermeasure, consult with the company from which you purchased the
equipment, and make the installation accordingly. In the rare event that a
refrigerant leakage and exceeding of threshold concentration does occur, there
is the danger of a resultant oxygen deficiency accident. For installation,
confirm that the installation site can sufficiently support heavy weight. When
strength is insufficient, injury can result from a falling of the unit.
Execute the prescribed installation construction to prepare for earthquakes
and the strong winds of typhoons and hurricanes, etc. Improper installations
can result in accidents due to a violent falling over of the unit. For
electrical work, please see that a licensed electrician executes the work
while following the safety standards related to electrical equipment, and
local regulations as well as the installation instructions, and that only
exclusive use circuits are used. Insufficient power source circuit capacity
and defective installation execution can be the cause of electric shocks and
fires. Accurately connect wiring using the proper cable, and insure that the
external force of the cable is not conducted to the terminal connection part,
through properly securing it. Improper connection or securing can result in
heat generation or fire. Take care that wiring does not rise upward, and
accurately install the lid/service panel. Its improper installation can also
result in heat generation or fire. When setting up or moving the location of
the air conditioner, do not mix air etc. or anything other than the designated
refrigerant (R410A) within the refrigeration cycle. Rupture and injury caused
by abnormal high pressure can result from such mixing. Always use accessory
parts and authorized parts for installation construction. Using parts not
authorized by this company can result in water leakage, electric shock, fire
and refrigerant leakage.
CAUTION
Execute proper grounding. Do not connect the ground wire to a gas pipe, water
pipe, lightning rod or a telephone ground wire. Improper placement of ground
wires can result in electric shock. The installation of an earth leakage
breaker is necessary depending on the established location of the unit. Not
installing an earth leakage breaker may result in electric shock. Do not
install the unit where there is a concern about leakage of combustible gas.
The rare event of leaked gas collecting around the unit could result in an
outbreak of fire. For the drain pipe, follow the installation manual to insure
that it allows proper drainage and thermally insulate it to prevent
condensation. Inadequate plumbing can result in water leakage and water damage
to interior items.
13
Is The Unit Installed Correctly
Confirm the following items for safe and comfortable use of air conditioner.
The installation work is to be burden on the sales dealer, and do not conduct
it by yourself.
Installation place
Avoid installing the air conditioner near Install the unit at well ventilated
place. the place where possibility of inflammable gas leakage exists.
Install the air conditioner firmly on the foundation that can fully support the weight of the unit.
Explosion (Ignition) may occur.
Select the place so as not to annoy neighbor with the hot air or noise.
If some obstacle exist, it may cause If not, it may cause vibration or noise. capacity reduction or noise increase.
Snow protection work is necessary where outdoor unit is blocked up by snow.
For details consult your sales dealer.
It is advisable not to install the air conditioner at the following special
place. It may cause malfunction, consult the sales dealer when you have to
install the unit on such a place.
The place where corrosive gas generates (Hot spring area etc.) The place where
salt breeze blows (Seaside etc.) The place where dense soot smoke exists The
place where humidity is extraordinarily high The place where near the machine
which radiates the electromagnetic wave The place where voltage variation is
considerably large
Electric work The electric work must be burden on the authorized engineer with
qualification for electric work and grounding work, and the work must be
conducted in accordance with electric equipment technical standard.
The power source for the unit is to be of exclusive use. An earth leakage
breaker should be installed.(This is necessary to prevent electric shock.) The
unit must be grounded.
When you change your address or the installation place Special technology is
required for removal or reinstallation of air conditioner, consult the sales
dealer. Besides, construction expense is charged for removal or
reinstallation.
For inspection and maintenance The capacity of air conditioner will decrease
by contamination of inside of unit when it is used for about three years
although depending upon the circumstances under which it is used, and so in
addition to the usual maintenance service, special inspection/maintenance
service is necessary. It is recommended to make a maintenance contract
(charged) by consulting your sales dealer.
14
Installation Procedure
Indoor Unit
NOTE
All wiring of this installation must comply with NATIONAL, STATE AND LOCAL
REGULATIONS. These instructions do not cover all variations for every kind of
installation circumstance. Should further information be desired or should
particular problems occur, the matter should be referred to your local
distributor.
WARNING
BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION.
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH,
EQUIPMENT MALFUNCTION AND/OR PROPERTY DAMAGE.
Preparation of indoor unit Before or during the installation of the unit, assemble necessary optional panel etc. depending on the specific type.
Select places for installation satisfying following conditions and at the same time obtain the consent on the part of your client user.
a.Places where chilled or heated air circulates freely. When the installation
height exceeds 3m warmed air stays close to the ceiling. In such cases,
suggest your client users to install air circulators.
b.Places where perfect drainage can be prepared and sufficient drainage. c.
Places free from air disturbances to the suction port and blowout hole of the
indoor unit, places where the fire alarm
may not malfunction or short-circuit. d.Places with the environmental dew-
point temperature is lower than 28 C and the relative humidity is less than 80
%.
(When installing at a place under a high humidity environment, pay sufficient
attention to the prevention of dewing such as thermal insulation of the unit.
) e.Installation dimension is the following.
(1) Installation by which service space is made on top of the unit
(recommended)
Install the unit away from the ceiling by 350mm or more
(2) Installation by which service is carried out from the bottom of the unit
Service space
500 or more
Service space
350 or more 30 or more
2500 or more (when no ceiling) FLOOR
Service access
Unit:mm
Service access
500 or more
Avoid installation and use at those places listed below.
a.Places exposed to oil splashes or steam (e.g. kitchens and machine plants).
Installation and use at such places incur deteriorations in the performance or
corrosion with the heat exchanger or damage in molded synthetic resin parts.
b.Places where corrosive gas (such as sulfurous acid gas) or inflammable gas
(thinner, gasoline etc.) in generated or remains. Installation and use at such
places cause corrosion in the heat exchanger and damage in molded synthetic
resin parts.
c. Places adjacent to equipment generating electromagnetic waves or high-
frequency waves such as in hospitals. Generated noise may cause malfunctioning
of the controller.
Pipe size
Model
Liquid side
Gas side
ADH071M1ERG ADH071M3ERG ADH090M1ERG ADH105M1ERG ADH125M1ERG ADH140M1ERG ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG
9.52mm
15.88mm
15
Installation Procedure
1. Preparation for suspending the unit a.Size of hole at ceiling and position
of hanging bolts
ADH071M1ERG ADH071M3ERG ADH090M1ERG ADH105M1ERG ADH125M1ERG ADH140M1ERG
D
70
Indoor Unit
ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG
AIR INLET
B A C
Hanging bolt position E
Ceiling hole size F
Panel dimensions
Pipe connection side
75
D
30 Ceiling ~ panel wrap dimensions
F
150
Model
A Hanging bolt position
B Ceiling hole size
C Panel dimensions
300
30
Ceiling ~ panel wrap dimensions
E
AIR OUTLET
Dimensions A(mm) B(mm) C(mm) D(mm) E(mm) F(mm)
ADH071M1ERG ADH071M3ERG ADH090M1ERG 983 1433 1493 595
ADH105M1ERG ADH125M1ERG ADH140M1ERG
1556 2006 2066 653
ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG
1285 1373 1163 543
740 800 798 858 1046 518
b.Hanger bolts installation Use care of the piping direction when the unit is installed.
Hole-in anchor Hole-in plug
Insert
2.Installation of indoor unit
Fix the indoor unit to the hanger bolts. If required, it is possible to
suspend the unit to the beam, etc. Directly by use of the bolts without using
the hanger bolts.
Concrete Hanging bolt M10
Note
When the dimensions of main unit and ceiling holes does not match, it can be
adjusted with the slot holes of hanging bracket.
M10 nut
Hanging bolt M10 washer
Adjusting to the levelness
Main unit
(a) Adjust the out-of levelness using a level or by the following method.
Make adjustment so that the relation between the lower surface of the unit proper and water level in the hose becomes as given below.
Piping side Supply water
(b) Unless the adjustment to the levelness is made properly, malfunctioning or failure of the float switch may occur.
Water level
0-6mm(for ADHM series) 5-20mm( for ADHH series)
M10 spring washer PVC hose
Bring the piping side slightly lower.
16
Installation Procedure
Installing Drain Pipes
CAUTION Install the drain pipe in accordance with the instructions in this
installation Manual and keep the area warm enough to prevent
condensation.Problems with the piping may lead to water leaks.
Be sure to properly insulate the drain pipes.
The position of the installed drain pipe should have a downward gradient of
1/100 or more. Do not connect the drain pipe in which ammonia or other types
of gas affecting the unit is generated.
For unit without water pump
1.5m~2m
Support
Drain Pipe
Down slope above 1/100 Insulation (supplied by the user)
Improper piping
Avoid riding across an elevation
Air vent
Keep free from traps
Do not pipe under water
Install the drain pipes according to the measurements given in the following
figure.
Flange positions for connecting the drain pipes.
395 407
66 130
Safety drain port 25(O.D.)
Main drain port 25(O.D.)
The size of drain opening
Unit model
The size of drain opening
ADH071M1ERG ADH071M3ERG ADH090M1ERG ADH105M1ERG ADH125M1ERG ADH140M1ERG
32mm(O.D.)
ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG
25mm(O.D.)
Please refer to the diagram and select drain pipe size according to drain opening inner diameter size.
(a) Drain piping should always be in a downhill grade (1/50~1/100) and avoid riding across an elevation or making traps.
Good piping
Suspension
bolts
1.5m ~ 2m
(b) When connecting the drain pipe to unit, pay sufficient attention not to
apply excess force to the piping on the unit side. Also, fix the piping at a
point as close as possible to the unit.
(c) For unit without water pump, the drain pipe shall be slant downwards
(greater than 1/100). The horizontal length of the drain pipe shall be less
than 20 m. In case of long pipe, supports shall be provided every 1.5~2m to
prevent wavy form. Central piping shall be laid out according to the right
figure. Take care not to apply external force onto the drain pipe connection
part.
(d) For unit with water pump drain pipe use hard PVC general purpose pipe VP
which can be purchased locally. When connecting, insert a PVC pipe end
securely into the drain socket before tightening securely using the attached
drain hose and clamp. Adhesive must not be used for connection of the drain
socket and drain hose (accessory).
Drain socket
Main unit
Pipe cover(large) VP(field purchased) [for insulation] (accessory)
Drain hose (accessory) Clamp (accessory) Adhesion
Pipe cover(small) [for insulation] (accessory)
VP(field purchased)
Pipe cover [for insulation] (field purchased)
Stage difference Drain hose Drain socket part
Heat insulation
A downhill grade of 1/100 or more
17
Installation Procedure
Drain Pipe
(e) When constructing drain piping for several units, position the common pipe
about 100 mm below the drain outlet of each unit as shown in the sketch. Use
VP-30(11/4″) or thicker pipe for this purpose.
Secure the elevation as high as possible (approx. 100 mm)
VP-30 A downhill grade of 1/100 or more
(f) The stiff PVC pipe put indoor side should be heat insulated. The height of
the drain head can be elevated up to a point 500 mm above the ceiling, and
when an obstacle exists in the ceiling space, elevate the piping to avoid the
obstacle using an elbow or corresponding gadget. When doing this, if the
stretch for the needed height is higher than 500 mm, the back-flow quantity of
drain at the event of interruption of the operation gets too much and it may
cause overflow at the drain pan. Therefore, make the height of the drain pipe
within the distance given in the sketch below.
290~325mm
Taking the ADH**H serials as an example, the installation of the drain pipe is
the following.
Use general hard polyvinyl chloride (VP25) and connect it with adhesive
(polyvinyl chloride) so that there is no leakage. Do not perform air bleeding.
Main drain pipe provide one trap on the main drain pipe near the indoor unit.
H1=100 mm(Approx) H2=50~100 mm
Unit Drain pan
Trap
H2 H1
Drain pipe
Safety drain There is no need to provide a trap for the safety drain pipe.If the safety drain pipe is connected to the main drain pipe,make the connection below the trap on the main drain pipe.
Drain hose
Right overhead
600
(Maximum local drain up dimension)
Joint for VP-25 (Local procurement)
(g) Avoid positioning the drain piping outlet at a place where generation of
odor may be stimulated. Do not lead the drain piping direct into a sewer from
where sulfur gas may generate.
(h) Because the drain spout is at the position, which negative pressure may
occur. So with the rise of water level in the drain pan, water leakage may
occur. In order to prevent water leakage, we designed a backwater bend. The
structure of backwater bend should be able to be cleaned. As the below figure
shown, use T type joint. The backwater bend is set near the air conditioner.
As figure shown, set a backwater bend in the middle of drain hose.
Unit Drain pan
Main pipe
Safety pipe
Drain pipe
Make sure that drain pipe is installed without rises. Do not perform air bleeding.
H2 H1
H1=100mm or the static pressure of air sending motor H2=1/2H1 (or between
50~100mm)
18
Rise Air bleeding
Rise
PROHIBITED
Installation Procedure
Drainage Test (1) Conduct a drainage test after completion of the electrical
work. (2) During the trial, make sure that drain flows properly through the
piping and that no water leaks from connections. (3) In case of a new
building, conduct the test before it is furnished
with the ceiling. (4) Be sure to conduct this test even when the unit is
installed in the
heating season.
Procedures (a) Supply about 1000 cc of water to the unit through the air
outlet
using a feed water pump. (b) Check the drain while cooling operation.
Before the electrical work has not been completed, connect a convex joint in
the drain pipe connection to provide a water inlet. Then, check if water leaks
from the piping system and that drain flows through the drain pipe normally.
Drain Pipe
Remove grommet. Make sure to install it back after test.
Insert water supply hose for 20 mm ~ 30 mm to supply water. (Insert hose facing toward bottom.)
Attached drain hose clamp
Main unit
Drain piping
Drain situation can be checked with transparent socket
Pour water into a convex joint.
Installation Procedure
Air Duct
Installation work for air outlet ducts
Air conditioner main unit
Calculate the draft and external static pressure and select the length, shape and blowout.
A Blowout duct 2-spot, 3-spot and 4-spot with specifications.
200 type duct are the standard
Note (1) Shield the central blowout hole for 2-spot. (2) Shield the blowout hole around the center for 3-spot.
Ceiling surface
B Special blowout (Option)
Heat
insulation
A Blowout duct (Optional or marketed item)
inlet duct (Optional or
Suction panel (Silent panel)
marketed item) C special inlet
Hole for check
(option) (with air
filter)
Limit the difference in length between spots at less than 2:1. Reduce the length of duct as much as possible. Reduce the number of bends as much as possible. (Corner R should be as larger as possible.) Use a band. etc. to connect the main unit and the blowout duct flange. Conduct the duct installation work before finishing the ceiling.
Bad example
Bad example Good example
Connection of suction, exhaust ducts a.Fresh air inlet
Inlet can be selected from the side or rear faces depending on the working
conditions. Use the rear fresh air inlet when the simultaneous intake and
exhaust is conducted. (Side inlet cannot be used.)
b.Exhaust (Make sure to use also the suction.) Use the side exhaust port.
State seeing from top of unit
Exhaust hole
Fig.1
Side fresh air inlet Rear fresh air inlet
Fig.2
19
Installation Procedure
Electrical wiring
WARNING
DANGER OF BODILY INJURY OR DEATH
TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFORE MAKING ANY
ELECTRIC CONNECTIONS. GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE
VOLTAGE CONNECTIONS.
Precautions for electrical wiring Electrical wiring work should be conducted
only by authorized personnel. Do not connect more than three wires to the
terminal block. Always use round type crimped terminal lugs with insulated
grip on the ends of the wires. Use copper conductor only.
Selection of size of power supply and interconnecting wires
Select wire sizes and circuit protection from table below. (This table shows 20 m length wires with less than 2% voltage drop.)
Item Model
Circuit breaker
Phase Switch breaker (A)
Overcurrent protector
rated capacity (A)
Power source wire size (minimum) (mm2)
Earth leakage breaker
Switch
Leak
breaker(A) current(mA)
ADH071M1ERG ADH071M3ERG ADH090M1ERG
1
30
26
4.0
40
30
ADH105M1ERG ADH125M1ERG ADH140M1ERG ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG
1
40
30
6.0
40
30
Wiring connection Make wiring to supply power to the outdoor unit, so that the power for the indoor unit is supplied by outdoor unit.
Outdoor 3 phase type
Outdoor single phase type
Except ADH071M3ERG
Indoor unit 1 2 3
Indoor unit 1 2 3
terminal block
Y/G
terminal block
Y/G
Outdoor unit terminal block
R
S
TN
123
Power supply:380-415V, 3N~,50/60Hz
Outdoor unit terminal block
LN
123
Y/G
Y/G
Power supply:1PH,220-240V~,50/60Hz
Y/G ADH071M3ERG
Indoor unit 1 2 3 terminal block
Outdoor unit terminal block
LN
123
Y/G
Power supply:1PH,220-240V~,50/60Hz
20
Address:Haier Industrial Park,Qianwangang Road,Eco-Tech Development Zone,Qingdao 266555,Shandong,P.R.C. Contacts: TEL +86-532-88936943; FAX +86-532-8893-6999 Website: www.haier.com