PLANET WGS-6325-8UP2X Industrial Wall-mount Managed Gigabit Ethernet Switch User Manual

June 17, 2024
PLANET

PLANET WGS-6325-8UP2X Industrial Wall-mount Managed Gigabit Ethernet

Switch

Product Information

Specifications

  • Model Name: WGS-6325-8UP2X
  • Copper Ports: 4 x 10/100/1000/2500T (Ports 1-4), 4 x 10/100/1000T (Ports 5-8)
  • Fibre Ports: 2 x 1G/2.5G/10GX

Product Usage Instructions

Package Contents
Thank you for purchasing the PLANET Industrial Wall-mount Managed Gigabit Switch, WGS-6325-8UP2X. The package should contain the following items:

  • The Wall-mount Managed Switch x1
  • Quick Installation Guide x1 pc
  • Wall-mounted Kit x1 set
  • RJ45 Dust Cap x8
  • SFP Dust Cap x2
  • 2-pin Terminal Block Connector x1

If any item is found missing or damaged, please contact your local reseller for replacement.

Requirements
To access the Wall-mount Managed Switch, you will need the following:

  • A computer with terminal emulation software, such as Tera Term or PuTTY.
  • It is recommended to use Chrome version 98.0.xxx or above to access the Wall-mount Managed Switch.
  • If the Web interface of the Wall-mount Managed Switch is not accessible, please turn off the anti-virus software or firewall and then try again.

Hardware Installation

Wall Mount Installation
To install the Wall-mount Managed Switch on the wall, follow these steps:

  1. Drill 4 holes with 8mm diameter on the wall. The horizontal and vertical distances between the 2 holes are 230mm and 124mm, respectively.
  2. Hammer the four anchors into the four holes.
  3. Screw the four given screws into the anchors to finish the wall-mount installation.

FAQ

Package Contents

Thank you for purchasing PLANET Industrial Wall-mount Managed Gigabit Switch, WGS-6325-8UP2X. The table below shows the model with the number of ports:

Model Name Copper Port Fiber Port
WGS-6325-8UP2X 4 x 10/100/1000/2500T (Ports 1-4)

4 x 10/100/1000T (Ports 5-8)

| 2 x 1G/2.5G/10GX

In the following sections, unless specified, the term “Wall-mount Managed Switch” mentioned in this quick installation guide refers to the above model. Open the box of the Wall-mount Managed Switch and carefully unpack it. The box should contain the following items:

If any item is found missing or damaged, please contact your local reseller for replacement.

Requirements

  • A flat-blade screwdriver
  • Workstations running Windows XP/2003/Vista/7/8/2008/10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols.
  • Workstations are installed with Ethernet NIC (Network Interface Card)
  • Ethernet Port Connection
    • Network cables — Use network (UTP) cables with RJ45 connectors.
    • The above Workstations is installed with Web browser.
    • The above Workstations have been installed with SSH and telnet client software, such as Tera Term or PuTTY.

NOTE: It is recommended to use Chrome 98.0.xxx or above to access the Wall-mount Managed Switch. If the Web interface of the Wall-mount Managed Switch is not accessible, please turn off the anti-virus software or firewall and then try it again.

Hardware Installation

Wall Mount Installation
To install the Wall-mount Managed Switch on the wall, simply follow the following steps:

  • Step 1: Drill 4 holes with 8mm diameter on the wall. The horizontal and vertical distances between the 2 holes are 230mm and 124mm, respectively.
  • Step 2: Hammer the four anchors into the four holes.
  • Step 3: Then the four given screws are screwed into the anchors to finish the wall-mount installation, as shown below.

Wall Hanging Installation
To hang the Wall-mount Managed Switch on the wall, simply follow the following steps:

  • Step 1: Drill 2 holes (one hole on each side) with 8mm diameter on the wall; the distance between the 2 holes is 230 mm and the line through them must be horizontal.
  • Step 2: Place two anchors inside the hole by hammering them. Then screw the two screws leaving a space of 2mm apart as shown in the circled diagram below.
  • Step 3: The switch, shown in the picture below, can now be hung on the wall.

Make sure the equipment is securely wall-mounted as strong vibration could cause it to drop or break.

Grounding the Device
The user MUST complete grounding wired with the device; otherwise, sudden lightning could cause fatal damage to the device. EMD (Lightning) DAMAGE IS NOT COVERED UNDER WARRANTY.

Wiring the Power and Alarm Inputs

The Wall-mount Managed Switch features a strong dual power input system incorporated into the customer’s automation network to enhance system reliability and uptime.

Model / Power Input Range PWR1 PWR2
WGS-6325-8UP2X DC 48-54V, 11A max

Note: Maximum power requirements also rely on the real site application.

Dual power input is required for maximum PoE loading

  • Single power input: Max. 240 watts PoE budget
  • Dual power input: Max. 480 watts PoE budget

Caution: PWR1 and PWR2 must provide exactly the same DC voltage for power load balance while operating with dual power input.

Terminal Block Connector Pinout
The Front Panel of the Wall-mount Managed Switch consists of one spring terminal block connector within 4 contacts. Please follow the steps below to insert the power wire.

Insert positive/negative DC power wires into Contacts V1+ and V1- for Power 1, or Contacts V2+ and V2- for Power 2.

Wiring Completed in Three Steps

  • Step 1: Press the flat-blade screwdriver diagonally into the release hole.
  • Step 2: Leave the flat-blade screwdriver pressed into the release hole and insert the wire into the terminal hole. Insert the wire until the stripped portion is no longer visible to prevent shorting.
  • Step 3: Remove the flat-blade screwdriver from the release hole. After you connect the wires, pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the terminal block.

The wire gauge should be in the range from 12 to 16 AWG.

Wiring the Alarm Contact
The alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the Wall-mount Managed Switch will detect the event status of the port or power failure and then forms an open circuit. The following illustration shows an application example for wiring the alarm contacts.

Web Login

Starting Web Management
The following shows how to start up the Web Management of the Wallmount Managed Switch. Note the Wall-mount Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address.
For example, the default IP address of the Wall-mount Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100) and the default subnet mask is 255.255.255.0.

Logging in to the Wall-mount Managed Switch

  1. Use Chrome 98.0.xxx or above Web browser and enter IP address https://192.168.0.100 to access the Web interface.
  2. When the following dialog box appears, please enter “admin” in both the default user name and password fields. The login screen in Figure 5-2 appears.
    • Default IP Address: 192.168.0.100
    • Default Username: admin
    • Default Password: admin
  3. After entering the password, the main screen appears as Figure 5-3 shows.
    The Switch Menu on the top of the Web page lets you access all the commands and statistics the Wall-mount Managed Switch provides. The Switch Menu always contains one or more buttons, such as “System”, “Switching”, “Routing”, “QoS”, “Security”, “PoE”, “Ring”, “ONVIF” and “Maintenance”.

NOTE: If you are not familiar with Switch functions or the related parameter, press “Help icon” anytime on the Web page to get the help description.

Saving Configuration via the Web
To save all applied changes and set the current configuration as a startup configuration, the startup-configuration file will be loaded automatically across a system reboot.

  1. Click the Save icon on the top Switch Menu bar.
  2. Press the “Save Configuration” button.
  3. Or the other way to save the setting is to Click Maintenance, Save Startup Config.

SSH Login

The Wall-mount Managed Switch also supports SSHv2 for remote management. The switch asks for user name and password for remote login when using SSHv2 client software; please use “admin” for both username and password.

  • Default IP address: 192.168.0.100
  • Username: admin
  • Password: admin

The user can now enter commands to manage the Wall-mount Managed Switch. For a detailed description of the commands, please refer to the following chapters.

  1. For security reason, please change and memorize the new password after this first setup.
  2. Only accept command in lowercase letter under console interface..

Configuring IP Address
The Wall-mount Managed Switch is shipped with default IP address shown below:

  • IP Address: 192.168.0.100
  • Subnet Mask: 255.255.255.0

To check the current IP address or modify a new IP address for the Switch, please use the procedure as follows:

Display of the Current IP Address

  1. At the “#” prompt, enter “show ip interface brief”.

  2. The screen displays the current IP address shown in Figure 6-2.
    Configuration of the IP Address

  3. At the “#” prompt, enter the following command and press as shown in following.
    The previous command would apply the following settings for the Wall-mount Managed Switch.

    • IP Address: 192.168.1.100
    • Subnet Mask: 255.255.255.0
  4. Repeat step 1 to check if the IP address has changed.

Storing the Current Switch Configuration
At the “#” prompt, enter the following command and press .

copy running-config startup-config

If the IP is successfully configured, the Wall-mount Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the Wall-mount Managed Switch through the new IP address.

NOTE: If you are not familiar with the command line interface(CLI) or the related parameter, enter “help” anytime in CLI to get the help description.

Recovering Back to Default Configuration

IP Address has been changed or admin password has been forgotten –
To reset the IP address to the default IP address “192.168.0.100” or reset the login password to default value, press the reset button on the front panel for about 5 seconds. After the device is rebooted, you can log in the Web interface management within the same subnet of 192.168.0.xx.

Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
PLANET online FAQs: https://www.planet.com.tw/en/support/faq
Switch support team email address: support@planet.com.tw
WGS-6325-8UP2X User’s Manual: https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=WGS&view=3#list

Copyright © PLANET Technology Corp. 2023.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.

Read User Manual Online (PDF format)