legrand DQFP20UST Flip Up Table Box Instruction Manual
- June 16, 2024
- Legrand
Table of Contents
legrand DQFP20UST Flip Up Table Box
Product Information
Specifications
- Product: Legrand Electrical Systems
- Conformance: Conforms to the current National Electrical Code or codes administered by local authorities
- Grounding: Should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities
- Safety: May present a possible shock or fire hazard if improperly installed or used
- NRTL Mark: Legrand electrical products may bear the mark of a Nationally Recognized Testing Laboratory (NRTL)
- Installation: Should be installed in conformance with current local and/or the National Electrical Code
- Usage: For use in dry locations only, not for use in floors
- Receptacle: Dust and splash resistant, disconnect power and allow it to dry thoroughly if liquid enters the unit
Product Usage Instructions
- Step 1 : Preparing the Installation
- Print the provided template and ensure it is scaled correctly and the correct size.
- Use an electric drill with a 1/2 [12.7mm] bit to drill corner pilot holes according to the template.
- Step 2: Cutting and Fitting the Enclosure
- Use a portable jigsaw to cut along the inside edge of the template line.
- Test fit the enclosure to the hole cut and adjust if necessary.
- Carefully file the opening with a wood rasp if needed.
- Step 3: Connecting and Mounting
- Connect any electrical feed and communications to the enclosure.
- Drop the enclosure into the opening.
- Attach the mounting brackets into the corresponding slots in the enclosure body for each side.
- Tighten the thumb screw until it comes in contact with the underside of the table. Do not overtighten.
- Step 4: Finalizing the Installation
- Make final terminations according to the provided instructions.
- Plug the cord into a proper electrical receptacle.
- GFCI protected circuits are recommended for added safety.
FAQ
-
Q: Can I use Legrand electrical systems in wet locations?
A: No, Legrand electrical systems are designed for use in dry locations only. They are not suitable for wet environments. -
Q: What should I do if liquid enters the receptacle?
A: Promptly disconnect the breaker or unplug power and allow the unit to dry thoroughly before using it again. -
Q: Are there any specific requirements for installation?
A: Legrand electrical systems should be properly grounded and installed in compliance with the requirements of the current National Electrical Code or codes administered by local authorities.
Wiremold®
deQuorum™ Flip-Up Table Box
No: 1013244 – 11/14
Installation Instructions
- Catalog Number(s)
- Country of Origin: Made in US
- Legrand electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities.
- All electrical products may present a possible shock or fire hazard if improperly installed or used. Legrand electrical products may bear the mark of a Nationally Recognized Testing Laboratory (NRTL) and should be installed in conformance with current local and/or the National Electrical Code.
- Caution: For use in dry locations only. Not for use in floors. The provided receptacle is dust and splash resistant only. If liquid enters the until, promptly disconnect breaker or unplug power and allow it to dry thoroughly
Communications Installation
- The communication compartment has two grommeted openings. One communication cable can be passed through each grommet to the large opening in the front of the box for termination.
Holecut Template
When printing copies of this template, be sure the template is scaled correctly and that it is the correct size once it is printed before proceeding.
For additional dimensional information and installation templates – please visit the CAD file section at www.legrand.us/wiremold
- With template provided, use an electric drill with 1/2″ [12.7mm] bit to drill corner pilot holes
- Use a portable jigsaw to cut along the inside edge of the template line. Test fit the enclosure to the hole cut. Carefully file opening with wood rasp if needed.
- Connect any electrical feed and communications and drop enclosure into opening.
- From under the table surface, attach mounting brackets into corresponding slots in the enclosure body for each side. Tighten the thumb screw until it comes in contact with underside of table. Tighten until snug. Do not overtighten. Make final terminations. Plug cord into a proper electrical receptacle. GFCI protected circuits are recommended
© Copyright 2014 Legrand All Rights Reserved
- 860.233.6251
- 1.877.BY.LEGRAND
References
- Legrand CA | Delivering and Managing Power, Light, and Data
- Legrand US | Delivering and Managing Power, Light, and Data
- Wiremold Wire and Cable Management Products from Legrand
- Manual-Hub.com – Free PDF manuals!
Read User Manual Online (PDF format)