HINKLEY 28910AZ-LL Tetra 1 Light 8 inch Tall LED Outdoor Wall Lamp Instruction Manual
- June 16, 2024
- HINKLEY
Table of Contents
HINKLEY 28910AZ-LL Tetra 1 Light 8 inch Tall LED Outdoor Wall Lamp
Product Information
- Product Name : HINKLEY
- Item No : 28910
- Manufacturer : HINKLEY
- Address : 33000 Pin Oak Parkway Avon Lake, OH 44012
- Contact : 800.446.5539 / 440.653.5500
- Website : hinkley.com
Specifications
- Mounting : Drawing 1
- Assembly : Drawing 2
- Fixture Type : Indoor/Outdoor
- Bulb Type : GU10
- Wiring Type : IS-18
Product Usage Instructions
Mounting Instructions
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
- Release mounting plate (4) from backplate (1) by removing screws (2).
- Secure mounting plate (4) to junction box (5) using screws (3) (Not Provided).
- Make wiring connections using IS-18 wiring instructions.
- Secure backplate (1) to mounting plate (4) using the previously removed screws (2).
- Lamp fixture with appropriate GU10 bulb (7).
- Place lens cover (9) onto the main fixture body (6) and use screws (11) to lock into place.
- Note: Orient the two weep slots toward the canopy/premise wall at install to ensure proper water drainage.
IS-18 Wiring Instructions
Safety Warning: Read wiring and grounding instructions (IS 18) and any
additional directions. Turn power supply off during installation. If new
wiring is required, consult a qualified electrician or local authorities for
code requirements.
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist-on connector – see Drawings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections.
Outdoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist-on connector – see Drawings 2 or 3.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Cover open end of connectors with silicone sealant to form a watertight seal.
- If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
IS200 Caulking Instructions
After securing fixture to the wall: It is recommended that the gap between the wall and the fixture backplate be sealed on the top and both sides, with a good quality waterproof caulk or silicone sealant (NOT INCLUDED) – see Drawing 1.
Bead of caulk to seal the gap.
Caulking Gun
Frequently Asked Questions (FAQ)
-
Q: What type of bulb does this fixture use?
A: This fixture uses a GU10 bulb. -
Q: Where can I find the wiring and grounding instructions?
A: The wiring and grounding instructions can be found in the IS-18 section of the user manual. -
Q: Do I need to hire an electrician for new wiring?
A: If new wiring is required, it is recommended to consult a qualified electrician or local authorities for code requirements. -
Q: How should I seal the gap between the wall and the fixture backplate?
A: It is recommended to use a good quality waterproof caulk or silicone sealant (NOT INCLUDED) to seal the gap.
Assembly Instructions
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
start here
- Release mounting plate (4) from backplate (1) by removing screws (2).
- Secure mounting plate (4) to junction box (5) using screws (3)(Not Provided).
- Make wiring connections using IS -18 on the next page.
- Secure backplate (1) to mounting plate (4) using the previously removed screws (2).
- Lamp fixture with appropriate GU10 bulb (7).
- Place lens cover (9) onto the main fixture body (6) and use screws (11) to lock into place°£ .
Note : orient the two weep slots toward the canopy/premise wall at install to ensure proper water drainage
DRAWING 1 – MOUNTING
DRAWING 2 – ASSEMBLY
IS200 Caulking Instructions
start here
After securing fixture to the wall it is recommended that the gap between
the wall and the fixture backplate be sealed on the top and both sides, with a
good quality waterproof caulk or silicone sealant (NOT INCLUDED) – see Drawing
After securing fixture in place it is recommended that the gap between the
mounting top and fixture base be sealed with any good quality waterproof caulk
or silicone sealant (not
included). It is also recommended that a small bead of caulk or sealant be put
under the ball knobs used to mount fixture – see Drawing 2.
I.S. 18 wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
wiring instructions
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Drawing 1 – Flush Mount
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
-
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially. -
Please refer to the grounding instructions below to complete all electrical connections.
Drawing 2 – Chain Hung
grounding instructions
-
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
Note : On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw. -
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2. -
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.
Drawing 3 – Post-Mount
- 33000 Pin Oak Parkway Avon Lake, OH
- 44012 800.446.5539 / 440.653.5500
- hinkley.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>