Sona ID-77 Wall LED
Product Information
Specifications
- Module Lengths : 4ft and 8ft
- Mount Spacing : Within 6″ of the fixture end or joint
- Tools Required : Gear Wrench
Product Usage Instructions
Step 1: Install Switchbox and Make Electrical Connections
- Recommended : For best mounting aesthetics, install the switchbox flush with the finished wall directly behind the fixture’s specified power location. Install two studs at the mounting location, leaving enough gap between the studs to accommodate a standard switchbox mounted sideways (about 4″).
- Make electrical connections in the switchbox with the supplied SVT cord. Secure the power cord with the supplied strain relief on the switchbox side.
- Alternate : Install the switchbox as close as possible to the fixture’s power mount location. Run the power cord (supplied) from the switchbox to the fixture. Crimp strain reliefs (supplied) on the cord inside the switchbox and fixture-level wire cover. Allow at least 12″ of cord outside the wall for connection.
Step 2: Attach Switchbox Cover Plate
- Feed the SVT cord through the hole in the supplied switchbox cover plate. Attach the cover plate to the switchbox with two screws (supplied by others). Secure the cover plate to the wall structure with two structural screws (supplied by others).
- Recommended : Attach the wall mount bracket to the switchbox cover plate with 3 screws (supplied). Leave the power cord outside the wall for connection.
- Alternate : Install the wall mount bracket within 6″ from the fixture end, as close as possible to the power supply. Secure the bracket to the wall structure.
Step 3: Install Wall Brackets
- Install the wall bracket at the power location.
- Install additional wall mount brackets as required for single fixtures or continuous rows. Ensure that the additional brackets are level with the first bracket.
- Important : Attach the wall mount brackets to the wall structure within 6″ from the ends of the fixture.
Step 4: Mount First Fixture
- Raise the first fixture into position and engage it on the wall brackets, then rotate it down into position.
- Important: For power locations, knock out 1/2″ EKO before raising into position. Go to Step 6 for further instruction.
Step 5: Complete Electrical Connection at End
- Power entry preparation (7708)
FAQ
-
Q: Can I install the Sona wall fixtures as standalone units?
A: Yes, the 4ft and 8ft modules can be installed as individual standalone units. -
Q: Can I join multiple Sona wall fixtures together to create continuous runs?
A: Yes, you can join multiple Sona wall fixtures together to create continuous runs. You will need Sona Joint Kit(s) for each in-row joint. -
Q: How far should the wall brackets be positioned from the fixture end or joint?
A: The wall brackets should be positioned within 6″ of the fixture end or joint. -
Q: What tools are required for installation?
A: Gear Wrench is the required tool for installation. -
Q: Are there any specific electrical and building codes that need to be followed during installation?
A: Yes, it is important to install the Sona wall fixtures in accordance with national and local building and electrical codes.
Installation Instructions
In 77 Sona Wall IFDI
System Overview
These instructions review how to install Sona wall mount fixtures. 4ft and 8ft
modules can be installed as individual standalone units, or they can be joined
together to create continuous runs. The graphics below show the components
required to install a typical run of Sona wall fixtures.
IMPORTANT : Read all instructions including fixture wiring AND mechanical
details before beginning installation.
Sona power mount kit(s)
- Wall bracket (S1)
-
10-32 x 5/6” machine screw (x3)
-
10-32 x 1/2” Philips screw (x2)
- J-box cover plate (x1)
- 1/2” bushing
Standalone or continuous run configurations
Module Lengths
Sona wall fixtures come in 4ft and 8ft modules. Overall module lengths are
shown below. Add 4-15/16” for each sculpted endcap or 7/16” for each flat
endcap.
Tools Required
- Medium Phillips Screwdriver
- 3/8” Wrench, 1/4” ratchet with 3/8” socket, or 3/8” Gear Wrench.
Mount Spacing
- Variable wall mount brackets can be positioned within 6″ of the fixture end or joint.
- Minimum one mount per fixture end and joint
IMPORTANT
All mount brackets must be secured to wall structure (studs or cross
braces). Wall bracket(s) must be installed within 6″ from fixture end (s).
-
Install switchbox and make electrical connections
RECOMMENDED : For best mounting aesthetics, install switchbox flush with finished wall directly behind fixture’s specified power location. Install two studs at mounting location. Leave enough gap between studs to accommodate standard switchbox mounted sideways (about 4″). Make electrical connections in switchbox with supplied SVT cord. Secure power cord with supplied strain relief on the switchbox side.
ALTERNATE : Install switchbox as close as possible to fixture’s power mount location. Run power cord
(supplied) from switchbox to fixture. Crimp strain reliefs (supplied) on cord inside switchbox and fixture-level wire cover. Allow at least 12″ of cord outside the wall for connection. -
Attach switchbox cover plate
Feed SVT cord through hole in supplied switchbox cover plate. Attach cover plate to switchbox with two screws (supplied by others). Secure cover plate to wall structure with two structural screws (supplied by others). -
Install wall bracket at power location
RECOMMENDED : Attach wall mount bracket to switchbox cover plate with 3 screws (supplied). Leave power cord outside wall for connection.
ALTERNATE : Install wall mount bracket within 6″ from fixture end, as close as possible to power supply. Secure bracket to wall structure. -
Install wall brackets at non-power locations
Install additional wall mount brackets as re-quired for single fixture or continuous rows. Ensure additional brackets are level with first bracket.
IMPORTANT : Attach wall mount brackets to wall structure within 6″ from ends of fixture. -
Mount first fixture
Raise first fixture into position and engage it on wall brackets, then rotate it down into position (as shown).
IMPORTANT : For power locations, knock out 1/2” EKO before raising into position. Go to STEP 6 for further instruction. -
Complete electrical connection at end
POWER LOCATION : Break 1/2″ knock-outs in cross plate before raising into position. Raise luminaire as described in STEP 5. -
Power entry preparation (7708)
Remove screws on both sides to allow LED light engine reflector to be removed. Untuck diffuser from under front lip of housing before removing light engine.
IMPORTANT : To avoid damage of light engine unplug the red & black DC wire harness connector from the light engine.
Once light engine and diffuser is moved away from wire cover you will have access to the knocked out 1/2” EKO.
Insert bushing from the inside of the luminaire. Begin preparation for power connection.
Install strain relief under reflector to secure power cord. Remove installed quick-connect plugs and complete electrical connections using wire nuts (supplied by others). Tuck wires into wiring cavity. NONPOWER
LOCATIONS : Cap all wires and tuck into wire cavity.
Power entry preparation (7708)
Recommended to unsecure top screws holding down light engine, to allow LED light engine to be slid away from the wall side.
IMPORTANT : If end screws are removed the reflector will not stop when slid. Do not lift light engine out to avoid damage to the DC wires connected to the LED boards.
Remove both screws securing back wall reflector. Remove back reflector to gain
access to the EKO knock out.
Insert bushing from the inside of the luminaire. Begin preparation for power
connection.
Install strain relief under reflector to secure power cord. Remove installed
quick-connect plugs and complete electrical connections using wire nuts
(supplied by others). Tuck wires into wiring cavity. NONPOWER
LOCATIONS : Cap all wires and tuck into wire cavity.
-
Mount second fixture
Insert joiner aligners into second (joining) fixture. Raise second fixture into position; at end opposite joint, engage fixture into wall mount bracket (shown in STEP 5). At joint, carefully slide fixture into position so that first and second fixtures are engaged on joiner aligners. -
Complete electrical connections at joint
Complete electrical connections at joint using supplied quick-wire connectors. Tuck wires into wiring cavity. -
Secure joint
Recommended for ease during installation remove both screws holding light engine and untuck diffuser from front lip of housing (See Step 7). This will allow for access to secure joint hardware. (see Step 12).
Secure joint using supplied nuts and bolts. Ensure star washer side faces against metal plate at end of fixture. Repeat steps 8 – 10 for each additional fixture in row. -
Install endcaps using supplied hardware. NOTE : Two different endcaps supplied (left/right)
. IMPORTANT : Led alite recommends hand-tightening screws or using low torque setting on power tools. -
Secure components (7708)
-
Secure fixture(s) to wall mount brackets with two screws (supplied, #10-32 x 1/2″) at each bracket location.
-
Lift light engine and slide back into place. Tuck diffuser back under front lip of housing.
-
Re-insert the two screws holding light engine in place.
Secure components (7718) -
Secure fixture(s) to wall mount brackets with two screws (supplied, #10-32 x 1/2″) at each bracket location
-
Slide light engine back into place and secure screws once flush to back reflector.
-
Secure screws to hold light engine in place. If completing power entry fixture re-install back reflector before sliding back light engine.
-
Finishing
Ensure all components are secure and installed according to code.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide rea-sonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ATTENTION : Install in accordance with national and local building and electrical codes.
- © 2023 Signify Holding. All rights are reserved. Reproduction in whole or part is prohibited without the written consent of the copyright owner.
- Phone : 604.888.6811
- Signify North America Corporation. 4
- 00 Crossing Bivd, Suite 600 Bridgewater, NJ 08807.
- Telephone : 855-486-2216
- Web : ledalite.com/products
- Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 253.
- Telephone : 800
- Revision D
- November 20, 2023
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>