YAESU VR-5000 Wideband Radio Scanner Receiver User Manual
- June 16, 2024
- YAESU
Table of Contents
- VR-5000 Wideband Radio Scanner Receiver
- Product Information
- Specifications
- Supplied Accessories
- Available Option
- Product Usage Instructions
- Front Panel Controls & Switches
- Rear Panel Connections
- Installation
- Memory Storage
- Memory Recall
- Enhanced Memory Channel Operation
- Memory Offset Tuning
- Naming Memories
- Naming Memory Groups
- Protecting Memories (Inhibits the Editing of Memorized
- Masking Memories
- Alpha-Numeric Memory Recall
- Programmable Memory Recall
- Memory Channel Sort
- PS (PreSet) Memory Channel
- Scanning
- Memory Scanning
- VFO scanning
- Programmable (Band Limit) Memory Scan (PMS)
- M-S Scan
- Band Scope Operation
- Smart Search Operation
- Priority Operation
- World Clock
- Timer Operation
- Optional Accessories
- AUTO Mode Preset Operation Parameters
- FAQ
- Q: What are the available options for the VR-5000?
- Q: How do I program and recall memories on the VR-5000?
- Q: Can I protect the memories on the VR-5000 from being
- Q: Does the VR-5000 support scanning functionality?
VR-5000 Wideband Radio Scanner Receiver
Product Information
Specifications
-
General Coverage Reception: 100 kHz to 2600 MHz
-
Modes: CW, SSB (LSB and USB), AM, FM (Wide and Narrow
bandwidths) -
Coverage includes: AM and FM broadcast bands, HF Shortwave
Bands up to 16 MHz, VHF and UHF TV bands, VHF AM aircraft band, and
a wide range of commercial and public safety frequencies
Supplied Accessories
The following accessories are included with the VR-5000:
- None mentioned in the manual
Available Option
No information provided in the manual.
Product Usage Instructions
Front Panel Controls & Switches
The front panel of the VR-5000 contains various controls and
switches for operating the receiver. The manual does not provide
specific details about each control and switch. Please refer to the
product’s official documentation or contact customer support for
detailed instructions on using the front panel controls and
switches.
Rear Panel Connections
The rear panel of the VR-5000 features various connections for
external devices. The manual does not provide specific details
about each connection. Please refer to the product’s official
documentation or contact customer support for detailed instructions
on using the rear panel connections.
Installation
To install the VR-5000 for everyday operation, follow these
steps:
-
Carefully unpack the VR-5000 from its packing carton.
-
Inspect the receiver for any signs of physical damage. Check
the knobs and switches for normal freedom of action. -
If any damage is suspected, write down your observations in
detail and notify the shipping company (if shipped) or your dealer
(if purchased in-person) immediately. -
Save the packing carton for possible use later.
Memory Storage
No information provided in the manual regarding memory
storage.
Memory Recall
No information provided in the manual regarding memory
recall.
Enhanced Memory Channel Operation
No information provided in the manual regarding enhanced memory
channel operation.
Memory Offset Tuning
No information provided in the manual regarding memory offset
tuning.
Naming Memories
No information provided in the manual regarding naming
memories.
Naming Memory Groups
No information provided in the manual regarding naming memory
groups.
Protecting Memories (Inhibits the Editing of Memorized
Channels)
No information provided in the manual regarding protecting
memories.
Masking Memories
No information provided in the manual regarding masking
memories.
Alpha-Numeric Memory Recall
No information provided in the manual regarding alpha-numeric
memory recall.
Programmable Memory Recall
No information provided in the manual regarding programmable
memory recall.
Memory Channel Sort
No information provided in the manual regarding memory channel
sort.
PS (PreSet) Memory Channel
No information provided in the manual regarding PS memory
channels.
Scanning
No information provided in the manual regarding scanning.
Memory Scanning
No information provided in the manual regarding memory
scanning.
VFO scanning
No information provided in the manual regarding VFO
scanning.
Programmable (Band Limit) Memory Scan (PMS)
No information provided in the manual regarding programmable
memory scan.
M-S Scan
No information provided in the manual regarding M-S scan.
Band Scope Operation
No information provided in the manual regarding band scope
operation.
Smart Search Operation
No information provided in the manual regarding smart search
operation.
Priority Operation
No information provided in the manual regarding priority
operation.
World Clock
No information provided in the manual regarding world clock.
Timer Operation
No information provided in the manual regarding timer
operation.
Optional Accessories
No information provided in the manual regarding optional
accessories.
AUTO Mode Preset Operation Parameters
No information provided in the manual regarding AUTO mode preset
operation parameters.
FAQ
Q: What are the available options for the VR-5000?
A: The manual does not provide information about available
options. Please refer to the product’s official documentation or
contact customer support for details on available options.
Q: How do I program and recall memories on the VR-5000?
A: The manual does not provide specific instructions for
programming and recalling memories. Please refer to the product’s
official documentation or contact customer support for detailed
instructions.
Q: Can I protect the memories on the VR-5000 from being
edited?
A: The manual does not provide information on protecting
memories. It is recommended to refer to the product’s official
documentation or contact customer support for guidance on memory
protection.
Q: Does the VR-5000 support scanning functionality?
A: The manual does not provide details about scanning features.
For information on scanning, please refer to the product’s official
documentation or contact customer support.
OPERATING MANUAL
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters 10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23
0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong
Kong
VERTEX STANDARD (AUSTRALIA) PTY., LTD.
Normanby Business Park, Unit 14/45 Normanby Road Notting Hill 3168, Victoria,
Australia
Contents
Introduction …………………………………… 1 Supplied Accessories ……………………………. 1 Available
Option ………………………………….. 1
Front Panel Controls & Switches ……. 2 Rear Panel Connections ………………….. 6
Installation …………………………………….. 8
Power connections ……………………………….. 8 Antenna considerations …………………………. 9 Basic
Operation ……………………………. 14 Introduction ………………………………………. 14 Turning the Power
On/Off …………………… 14 Adjusting the Volume and Squelch ………. 14 Frequency
Navigation …………………………. 14 Mode Selection ………………………………….. 15 Channel Step
Selection ……………………….. 16 Dual Receive ……………………………………… 16 Setting the clock
………………………………… 17 Receiving Short-Wave Broadcast Stations … 18 Memory Operation
……………………….. 20 Main Memory System ………………………… 20
Memory Storage …………………………….. 20 Memory Recall ………………………………. 20 Enhanced Memory
Channel Operation …. 22 Memory Offset Tuning ……………………. 22 Naming Memories
………………………….. 22 Naming Memory Groups …………………. 24 Protecting Memories (Inhibits
the
Editing of Memorized Channels) …. 24 Masking Memories …………………………. 25 Alpha-
Numeric Memory Recall ……….. 26 Programmable Memory Recall …………….. 26 Memory
Channel Sort ………………………… 28 PS (PreSet) Memory Channel ………………. 29 Scanning
………………………………………. 30 Memory Scanning ………………………………. 32 VFO scanning
……………………………………. 33 Programmable (Band Limit)
Memory Scan (PMS) … 34 M-S Scan ………………………………………….. 36
Band Scope Operation ………………….. 37 Smart Search Operation ……………….. 38 Priority
Operation ………………………… 39 World Clock …………………………………. 40 Timer Operation
…………………………… 42
ON/OFF Timer ………………………………….. 42 Sleep Timer ……………………………………….. 43 Alarm Timer
……………………………………… 43 DSP Operation ……………………………… 44 DSP NOTCH Filter …………………………….
44 DSP Bandpass Filter …………………………… 44 DSP CW Peaking Filter ………………………. 45 DSP
Noise Reduction …………………………. 46 CW-PITCH ……………………………………….. 46 Miscellaneous
Features …………………. 47 ATT (RF Attenuator) ………………………….. 47 NB (Noise Blanker)
……………………………. 47 RF TUNE ………………………………………….. 47 Keypad Beeper ………………………………….. 47
Locking Front Panel Controls ………………. 48 Display Contrast ………………………………… 49
Display Dimmer ………………………………… 49 Selecting the [F] key “Hang” Time ………. 49
Voice Synthesizer Operation ……………….. 50 Digital Voice Recorder ……………………….. 50
Field Strength Meter …………………………… 51 Audio Wave Meter …………………………….. 52 Radio
Control (R/C) Channel Monitoring . 52 Cloning ………………………………………… 53 CAT
Operation …………………………… 54 Reset …………………………………………….. 56 Installation of the
Optional Accessories … 57 “AUTO” Mode Preset
Operationg Parameters …. 58
Introduction
The VR-5000 is a communications receiver providing general coverage reception
from 100 kHz to 2600 MHz on the CW, SSB (LSB and USB), AM, and FM (Wide and
Narrow bandwidths) modes (this coverage includes the AM and FM broadcast
bands, HF Shortwave Bands up to 16 MHz, VHF and UHF TV bands, the VHF AM
aircraft band, and a wide range of commercial and public safety frequencies!).
Installation of the VR-5000 for everyday operation is may be accomplished in
minutes. However, care should be taken in the installation process, so as to
ensure maximum performance and safety. The procedures described below will
ensure that you get the most out of your new VR-5000 receiver.
INITIAL INSPECTION
After carefully removing the VR-5000 from its packing carton, inspect it for
any signs of physical damage. Rotate the knobs and push the switches, checking
each for normal freedom of action. If damage is suspected, write down your
observations in detail, and notify the shipping company (if the set was
shipped to you) or your dealer (if you purchased the set in-person)
immediately. Save the packing carton for possible use later.
SUPPLIED ACCESSORIES
AC Adapter PA-28B (120 V)/C (230-240 V)/U (230 V) DC Cable Operating Manual
AC Adapter PA-28
AVAILABLE OPTIONS
Digital Signal Processing Unit Voice Synthesizer Unit Digital Voice Memory Unit
DSP-1 FVS-1A DVS-4
DC Cable
VR-5000 OPERATING MANUAL
1
Front Panel Controls & Switches
PWR
SUB SET BS SET BS STEP M-S SCAN PMS SET PRI CLR DIM
M/S
B S
SCAN PMS CLR
PS
ADRS MODE
REC COPY X PLAY STEP M W V / M
ATT 1
SPL 4
VCS 7
LOCK S.SRCH
2
3
PRI S.CALL
5
6
RF TUNE TIMER
8
9
SET ENT BEEP
. N B 0
DSP
BANK
MAIN VOL/SQL Knob
MAIN VOL Knob The inner MAIN VOL knob adjusts the audio volume of the MAIN
receiver in the speaker or headphones.
SQL Knob The outer SQL knob sets the signal level threshold at which MAIN
receiver audio is muted (and the “BUSY” icon in the LCD turns off), in all
modes. This is normally kept fully counter-clockwise, except when scanning and
during FM operation.
SUB VOL/TONE Knob
SUB VOL Knob The inner SUB VOL knob adjusts the audio volume of the SUB
receiver in the speaker or headphones.
TONE Knob The outer TONE knob adjusts receiver audio characteristics.
PHONES Jack
This 3-pin (“stereo”) miniature jack is used for connection to your
headphones. When a plug is inserted into this jack, the internal (or external)
speaker will be cut off. This jack’s impedance is optimized for use with 16 to
32 headphone types.
2
VR-5000 OPERATING MANUAL
Front Panel Controls & Switches
PWR Knob
This is the main on/off switch for the VR-5000. Press and hold this switch for
one second to toggle the receiver’s power on and off.
LCD (Liquid Crystal Display)
The upper half of the display consists of a dot-matrix display for frequency
readout, plus various icons representing enabled receiver features. The lower
half contains a dot-matrix display for Band Scope viewing, menu programming,
and alpha numeric name display, etc.
Main Band Frequency
Main Band Channel Step
Memory Channel Number
Main Band S-Meter Main Band Reception Mode
Memory Bank Number Main Band Scan-Resume
Sub Band Reception Mode
Clock Memory Name
Bank Name
Sub Band Channel Step
Sub Band Squelch Open
Sub Band Frequency
Sub Band Scan-Resume
Function Keys
D : DELAY SCAN P : PAUSE SCAN H : HOLD SCAN
[M/S(SUB SET)] Key
Press this key momentarily to toggle the operating VFO between the MAIN VFO and
SUB VFO.
Press this key, after [F] key is pressed, to toggle the VFO link feature on and off.
[BS(BS SET)] Key Press this key momentarily to toggle the Band Scope feature on and off. Press this key twice, after the [F] key is pressed (when the Band Scope is activated) to activate the SUB VFO cursor, which enables SUB VFO tuning.
VR-5000 OPERATING MANUAL
3
Front Panel Controls & Switches
[WIDTH(BS STEP)] Key Press this key momentarily to select the Band Scope sweep
width. Press this key after [F] key is pressed (when the Band Scope is
activated) to select the Band Scope sweeping step size.
[SCAN(M-S SCAN)] Key Press this key momentarily to activate the scanning
function. Press this key after [F] key is pressed to activate the “M-S
Scanning” feature. M-S Scan: The scanner hops back and forth between the MAIN
VFO frequency and SUB VFO frequency.
[PMS(PMS SET)] Key Press this key momentarily to activate the Programmable
Memory Scan feature. Press this key after [F] key is pressed to enable PMS
memory (band edge) programming. PMS Scan: The scanner sweeps a user-defined
subband of frequencies (e.g. 450-480 MHz).
[CLR(PRI CLR)] Key Press this key momentarily to clear (cancel) the function
you currently are programming. Press this key after [F] key is pressed to
disable Priority Channel operation. [V(DIM)] Key Press this key momentarily to
enable adjustment of the display brightness. Press this key after [F] key is
pressed to activate the optional FVS-1A Voice Synthesizer Unit which provides
announcement of the operating frequency (with resolution to the displayed 100
Hz digit) for operators with vision impairments.
PS Key
Press this key momentarily to recall one of up to five PS (PreSet) memories
for operation. Press and hold this key for one second to store the operating
parameters into consecutive PS memories.
Command Keys
[MODE(ADRS)] Key Press this key momentarily to select the operating
(receiving) mode. Repeated pressing of this key will scroll you through the
available receiving mode choices. Press this key after [F] key is pressed to
select the recording field (memory register) for the voice recorder (requires
the optional DVS-4 Digital Voice Recorder unit).
[COPY(REC)] Key Press this key momentarily to copy the SUB VFO data into the
MAIN VFO. Press this key after [F] key is pressed to start the voice recorder.
4
VR-5000 OPERATING MANUAL
Front Panel Controls & Switches
[STEP(PLAY)] Key Press this key momentarily to select the synthesizer steps to
be used during VFO operation. Press this key after [F] key is pressed to
initiate playback on the voice recorder.
[V/M(MW)] Key Press this key momentarily to change the frequency control
method between the VFO and the Memory systems. Press this key after [F] key is
pressed to initiate the memory storage process.
[BANK] Key Press this key momentarily to select the desired memory bank.
T(W)/S(X) Keys
In the VFO mode, pressing either of these keys momentarily steps (according to
the DIAL knob’s step setting) the operating frequency down or up,
respectively. Pressing either of these keys after [F] key is pressed causes a
frequency hop of 10 MHz down or up. In the Memory mode, pressing either of
these keys momentarily steps the Memory Channel down or up respectively. While
the Band Scope is engaged, pressing either of these keys moves the Channel
Marker.
Keypad
This keypad is used for direct frequency entry during VFO operation. Secondary
functions (activated by first pressing the [F] key) allow control of the
VR5000’s various control functions.
[F] Key
This key is used to activate the “Alternate” command functions of the panel
keys. If this key is pressed before one of the panel keys is pressed, the
“Alternate” functions of the key will be enabled.
DSP Key
Press this key momentarily to activate the optional DSP-1 Digital Signal
Processing Unit.
DIAL Knob
This is the main tuning dial for the VR-5000. It is used for most tuning,
memory selection, and function setting tasks on the VR-5000.
VR-5000 OPERATING MANUAL
5
Rear Panel Connections
DC 13.5V
MUTE
ANT B
B
A
ANT
ANT A
EXT SP REC
+8V
IF OUT
CAT
DC 13.5V Jack
This is the DC power supply connection for the VR-5000. Connect the Supplied
PA28 AC adapter to this jack.
MUTE Jack
If using the VR-5000 with a transceiver, shorting this jack during transmit
will mute receiver output and attenuate the RF signal input. Check the
information provided with your particular transceiver for details regarding
proper connection.
ANT B Terminal
Use these spring-loaded terminal connectors to connect a high-impedance
antenna.
ANT Switch
This switch selects antennas connected to the ANT A jack or ANT B terminal.
ANT A Jack
Connect the 50 coaxial feed line from your low-impedance antenna here, using a
type-M (PL-259) connector.
6
VR-5000 OPERATING MANUAL
Rear Panel Connections
EXT SP Jack
This 2-contact mini phone jack provides receiver audio for an external
loudspeaker with an impedance of 4 ~ 16 . Inserting a plug in this jack
disables the loudspeaker.
REC Jack
This jack provides a constant level (8 mV @ 1 k) audio output, which is
unaffected by the VOL and TONE controls. This audio can be used for tape-
recording purposes, and for connection to data demodulator/decoder equipment.
+8V Jack
This output jack provides 8V DC at up to 100 mA for providing DC voltage to
low power accessories. The center contact is positive.
IF OUT Jack
This output jack provides low-level 10.7 MHz IF output.
CAT Jack
This 9-pin serial DB-9 jack allows external computer control of the VR-5000.
Connect a serial cable here and to the RS-232C “COM” port on your personal
computer.
VR-5000 OPERATING MANUAL
7
Installation
PHYSICAL LOCATION OF THE RECEIVER
The VR-5000 should be located in a place that allows unobstructed ventilation
around the cabinet. Although the VR-5000 does not produce significant amounts
of heat, as with any electronic device a well-ventilated location will ensure
that heat does not build up inside the cabinet.
Do not place the VR-5000 on top of another heat-generating device, and keep
its top cover free of books, papers, and other objects which might impede
ventilation.
If you utilize a computer in your monitoring location, we recommend that the
VR-5000, its feedline, and its power cord all be kept as far away from the
computer as possible, as the computer, its monitor, and/or other peripherals
may radiate energy which can interfere with reception. Experimentation with
several different locations may be necessary, in order to find the most
interference-free location.
POWER CONNECTIONS
Base Station Operation
PA-28 AC Power Adapter Installation
Your VR-5000 is supplied with an AC Power Adapter, model PA-28, which provides the 13.5 Volts (DC) required by the VR-5000. We do not recommend any other type of power adapter for use with this product.
To install the PA-28, first connect the small, round DC output connector on the cable of the PA-28 to the DC 13.5V jack on the rear panel of the VR-5000. Then plug the PA-28 into the AC wall outlet.
When disconnecting the PA-28, it is recommended that you first turn the VR-5000 off, then unplug the PA-28 from the wall outlet, then unplug the round DC output connector.
When making power connections, always grasp the DC output connector, or the body of the PA-28, so as to minimize strain on the power cable. Never disconnect the PA-28 by pulling on either end of the cable, as this may lead to early mechanical failure of the PA-28.
DC Power Supply Connections
A well-regulated 13.5 Volt DC Power Supply may also be used with the VR-5000, providing it is capable of supplying 1 Ampere of current continuously. A DC cable is supplied with your VR-5000 for connection to a power supply.
When making power connections to a power supply, be absolutely certain to observe the correct polarity, as serious damage can occur if the connections are reversed.
Connect the wire containing the White Stripe to the Positive (+) DC output terminal, and connect the All-Black wire to the Negative () DC output terminal. Double-check your hookup before plugging the DC output connector into the VR-5000.
8
VR-5000 OPERATING MANUAL
Installation
We recommend that, when using an external DC power supply, you turn the power
supply on, then turn on the VR-5000; when shutting down, turn the VR-5000 off
first, then turn off the power supply.
If the input voltage becomes too low (due to power supply failure or a problem
in the DC cable), the VR-5000’s display will indicate “ERROR LOW VOLTAGE” If
this should happen, check the output voltage from your power supply; if it is
OK, then look for a problem in the DC cable.
Important Notice Be absolutely certain to observe correct power supply
polarity. Our Limited Warranty does not cover damage caused by improper power
supply voltage or polarity.
ANTENNA CONSIDERATIONS
Antenna performance is critical to successful reception using the VR-5000.
Extra time and care in installing your antenna(s) will reap great benefits for
your monitoring station.
Best performance will always be obtained by the use of an outdoor antenna
system, installed as high and in the clear as reasonably possible. Indoor
antenna installations generally suffer from high levels of interference from
computers and other electronic devices, as well as noise generated by
fluorescent lights and home appliances.
Because of the wide frequency range of the VR-5000, no single antenna can be
expected to provide optimized performance on all available frequencies.
Therefore, separate discussions will address antenna principles for three
general categories of antenna frequency range.
Important Safety Note
Never install an antenna where it (or its supporting mast) could possibly come
in contact with utility power lines, even in a catastrophic wind storm. Such
power lines carry thousands of volts of energy, and you can be killed
instantly if the antenna connected to this product should come in contact with
power lines, even for an instant. The utilization of the services of a
professional antenna-installation company is highly recommended, if you have
any doubts about your ability to install your antenna system safely.
VR-5000 OPERATING MANUAL
9
Installation
Antennas for Low- and Medium-Frequency Reception (below 2 MHz)
Good all-around reception will be obtained using a single long random length
wire, connected to the (red) Hi-Z terminal on the rear panel. The wire should
be supported as high above ground as possible by insulators at the end at
possibly mid-span, depending on the length of the wire. The longer the wire,
the stronger will be the signals received.
Insulated wire is generally preferred, as it is less susceptible to corrosion.
The wire should be clear of nearby metallic objects to the greatest extent
possible.
A good earth ground connection, as shown in the illustration, can be essential
to good performance of a random length antenna. It may be connected to the
Black terminal just to the left of the Red antenna terminal.
Antennas for Short-wave (HF)
Optimum performance on frequencies between 2 and 30 MHz will generally be
obtained through use of a resonant antenna with an impedance near 50 Ohms at
the frequency of interest. Broadband or multiband “Dipole” antennas, such as
the Yaesu model YA-30, are available from your dealer.
If a particular frequency in the HF range is of interest to you, a half-
wavelength Dipole antenna may easily be constructed from readily-available
materials. A dipole consists of a length of wire, cut according to the
formulas below; the wire is broken in the middle, and insulators are installed
at each end and in the middle. A 50- or 75-Ohm coaxial cable is then connected
in the middle, with the center conductor of the coaxial cable going to one
side of the center insulator and the shield of the coaxial cable connecting to
the other side of the insulator.
Length (meters) = 142.5 ÷ Frequency (MHz), or Length (feet) = 468 ÷ Frequency
(MHz)
Better “balance” in the antenna’s reception pattern will be obtained if you
make a coil of coaxial cable, ten turns of about 10″ (25 cm) in diameter, just
below the center insulator of the Dipole antenna. Tape the turns together
securely to hold them in place.
The Dipole will work well near its design frequency. However, if you are
interested in reception on several frequency bands separated by a number of
MHz (for example, the 7 MHz band and the 15 MHz band), you may wish to cut
wires for each band of interest, and solder the center ends of these
different-length wires together on each side of the center insulator. The
outer ends may then be fanned out so that they are separated by a few feet.
Install a type “M” (“PL-259”) coaxial connector at the station-end of the
coaxial cable, and connect the coaxial cable to the coaxial jack (“Antenna A”)
on the rear panel of the VR5000.
10
VR-5000 OPERATING MANUAL
Installation
Antennas for VHF and UHF Reception
Any antenna used for reception above 30 MHz will be fed with coaxial cable, so
it must be connected to the Antenna A jack.
The wide frequency coverage of the VR-5000 means that a wide-band vertical
antenna (such as the “Discone” type) will be required for reasonable
performance on the VHF and UHF bands. Optimized narrow-band vertical antennas
will provide better performance on a specific frequency range, at the expense
of poorer performance on other frequencies.
While vertical orientation of the antenna will be compatible with the
configuration of the majority of base and mobile stations being heard,
horizontally-oriented antennas are often used by amateur radio stations using
the USB and CW modes in the 50 MHz, 70 MHz (U.K.), 144 MHz, and 432 MHz bands.
Whichever antenna(s) you use, it is important to use the best quality (lowest
loss) coaxial cable possible, as cable loss in a long length of coaxial cable
can be very high if smalldiameter cable is used. This will reduce the strength
of the incoming signals, making reception of weaker signals difficult or
impossible.
Your local dealer will be in the best position to recommend an antenna type,
as well as installation tips, for successful monitoring in your area.
Antenna Switching
Antenna switching between the coaxial Antenna-A and long-wire Antenna-B jacks
(on the rear panel of the receiver) is accomplished using the ANT A/B slide
switch, located between the two antenna jacks on the rear panel of the
VR-5000. An antenna may be connected to each jack; there is no need to remove
an antenna when the alternate jack is being used.
If multiple antennas are to be used in conjunction with the coaxial Antenna A
jack, consult your dealer regarding the procurement of a coaxial antenna
switch suitable for the frequency range of interest.
Important Note Regarding Antenna Safety!
Disconnect all antennas connected to the VR-5000 if you receive information
that a lightning storm is approaching your area. Extremely high voltages can
be fed into your station through an antenna system, and a receiver struck by
lightning will be permanently damaged or destroyed.
Do not, however, attempt to disconnect your antenna(s) if a lightning storm is
in progress in your immediate area. You could be killed instantly if you are
handling the antenna or its feedline at the moment lightning strikes!
VR-5000 OPERATING MANUAL
11
Installation
MUTE Terminal Connections
The MUTE jack on the rear panel allows the receiver to be silenced during
transmission, should the VR-5000 be utilized with an external transmitter (not
available from Yaesu). Typically, such a transmitter will have an internal
relay, the contacts of which will close to ground during transmission;
connection of a cable connected to this type of switching system will cause
the audio output from the VR-5000 to be cut off (when the center conductor is
shorted to ground).
If an external transmitter is used, it is important also to disconnect all antennas connected to the VR-5000 during transmission. An external switch or relay will be required for this task.
Transmmiter triggerd relay
Normally Open (N.O) MUTE
Common
GND
Normally Closed (N.C)
DC 13.5V
MUTE
ANT B
B
A
ANT
ANT A
EXT SP REC
+8V
IF OUT
CAT
GND EXT SP (4 16 )
GND 8 mV (rms) at 1 k impedance
REC Jack Connections
The rear panel’s REC jack provides constant-level “Line Out” audio output,
suitable for connection to a tape recorder, modem, or computer sound card for
recording or datadecoding purposes. The front panel Volume control does not
affect the output level at this jack, which is 8 mV (rms) at 1 k impedance.
EXT SP Jack Connections
An external loudspeaker may be connected to the rear panel’s EXT SP jack. The
external loudspeaker should have an impedance between 4 and 16. Do not connect
earphones to this jack, as the output level is high enough to yield the
potential for hearing damage.
12
VR-5000 OPERATING MANUAL
Installation
+8V Jack Connections
The +8V jack may be used for powering of small accessories. The output
current, however, is limited to 100 mA or less, so check the current
requirements for your accessory before connecting it to this jack.
Exercise particular care with any cables connected to this jack. If the far
end of the cable should become shorted to ground (perhaps by accidental
contact with a metal surface), the internal fuse for this jack will “blow”
instantly.
IF OUT Jack Connections
A portion of the 10.7 MHz Intermediate Frequency (IF) stage signal is
available via this jack. This may be used for observing signal
characteristics, or a separate receiver may be connected here to monitor FM
broadcast sub-carrier signals, etc.
VR-5000 OPERATING MANUAL
13
Basic Operation
INTRODUCTION
The VR-5000 utilizes a “VFO” (Variable Frequency Oscillator) tuning system for
frequency selection. Two VFOs are provided, termed the “MAIN” and “SUB” VFOs
in this manual. The VFOs utilize tuning “steps” which vary between operating
modes, and which may be set by the owner according to your location and
operating preferences. Fundamentally, however, a VFO may simply be thought of
as a tuning dial for the receiver.
Details regarding setup and operation of the VR-5000 are found in the pages to
follow.
TURNING THE POWER ON/OFF
Press and hold the orange PWR switch for one second to turn the radio on and
off. The one-second delay minimizes the chance that the radio will
accidentally be turned on or off by bumping the PWR switch.
ADJUSTING THE VOLUME AND SQUELCH
1. Rotate the MAIN VOL knob to adjust the audio volume of the MAIN VFO.
Rotate the SUB VOL knob to adjust the audio volume of the SUB VFO. Clockwise
rotation of these VOL knobs increases the volume level. Both VOL knobs can be
rotated to adjust the relative balance of receiver audio between the two VFOs
during dual reception.
2. The VR-5000 squelch system allows you to mute the receiver’s audio output
when no signals are being received. To set the squelch, turn the SQL knob
fully counter- clockwise, then turn it clockwise just past the point where the
background noise is silenced. Do not rotate the SQL knob much beyond this
threshold point; if you do, the receiver will not respond to weak signals.
3. Rotate the TONE knob to adjust the receiver’s audio characteristics.
Clockwise rotation of the TONE knob emphasizes the high-frequency component.
The TONE knob affects both the MAIN and SUB VFO audio.
FREQUENCY NAVIGATION
Tuning DIAL
Rotating the DIAL knob allows tuning in the pre-programmed steps established
for the current receiving band. Clockwise rotation of the DIAL knob causes the
VR-5000 to be tuned toward a higher frequency, while counter-clockwise
rotation will lower the receiving frequency.
If you press the [F] key momentarily, then rotate the DIAL knob, frequency
steps of 1 MHz will be selected. This feature is extremely useful for making
rapid frequency excursions over the wide tuning range of the VR-5000.
14
VR-5000 OPERATING MANUAL
Basic Operation
UP(S)/DOWN(T) Tuning
Pressing the [T(W)/S(X)] keys allows tuning in the pre-programmed steps
established for the current receiving band. Pressing the [S(X)] key causes the
VR-5000 to be tuned toward a higher frequency, while pressing the [T(W)] key
will lower the receiving frequency.
If you press the [F] key momentarily, then press the [T(W)/S(X)] keys,
frequency steps of 10 MHz will be selected. The larger 10 MHz hops are
extremely useful for making rapid frequency excursions over the wide tuning
range of the VR-5000.
Direct Keypad Frequency Entry
The desired receiving frequency may be entered directly from the keypad.
The receiving mode (FM, SSB, AM, etc.) will automatically be set once the new frequency is entered via the keypad, based on the operating frequency you have chosen.
To enter a frequency from the keypad:
1. Enter the “MHz” portion of the frequency on which you wish to receive. 2.
Enter the decimal point after the “MHz” portion by pressing the [· (BEEP)]
key. 3. Enter five more digits to complete the frequency. 4. If there are
“zeros” at the end of the frequency, you may press the [ENT(SET)] key
after the final non-zero digit.
Examples: To enter 146.16250 MHz, press [1] ¯ [4] ¯ [6] ¯ [·] ¯ [1] ¯ [6] ¯ [2] ¯ [5] ¯ [0]
To enter 950 kHz,
press [·] ¯ [9] ¯ [5] ¯ [0] ¯ [0] ¯ [0]
To enter 445.40000 MHz, press [4] ¯ [4] ¯ [5] ¯ [·] ¯ [4] ¯ [ENT]
MODE SELECTION
The VR-5000 automatically selects a default receiving mode according to the
frequency band on which you are receiving. However, many bands (especially HF
Short-wave) may use a variety of transmission modes in a particular frequency
segment.
If you want a change the receiving mode, press the [MODE(ADRS)] key. The
receiving modes available are:
AUTO LSB USB CW WFM FM-N WAM AM AM-N
VR-5000 OPERATING MANUAL
15
Basic Operation
CHANNEL STEP SELECTION
Operation of the VR-5000 initially is set up in the “AUTO” mode (mentioned in
the previous section), whereby the reception mode (such as AM or FM) is
automatically set according to the frequency in use; at the same time, the
channel steps typically used in that frequency segment are also programmed
automatically.
However, some frequency segments involve several different services which may
use different channel steps. So you may wish to modify the channel steps; to
do this, you must first exit the “AUTO” mode, then select the desired steps.
The procedure is:
1. Note the operating mode in which you are operating via the “AUTO” mode
(for example, FM-N).
2. Press the [MODE(ADRS)] key as many times as required to shift to the
operating mode which had been selected by the “AUTO” mode.
3. Press the [STEP(PLAY)] key as many times as required to shift to the
desired channel step selection (for example, 5 kHz).
DUAL RECEIVE
The VR-5000 provides two VFOs (MAIN VFO and SUB VFO), which operate in a Dual
Receive configuration (simultaneous reception using both VFOs). The SUB VFO
frequency must be set within ±20 MHz of the MAIN VFO frequency (for example,
if the MAIN VFO is set to 1280.000 MHz, the SUB VFO can be set to 1260.000 ~
1300.000 MHz). Also, the SUB VFO may be set only AM or FM-N modes.
The MAIN VFO is the upper displayed frequency, while the SUB VFO is the lower
displayed frequency. The relative size of the frequency displays indicates
which VFO you currently are tuning on (the larger display size indicates the
“active” VFO). Independent Volume controls are provided for each VFO; just
turn the Volume down if you do not wish to listen to communications on a
particular channel.
MAIN VFO
SUB VFO
16
VR-5000 OPERATING MANUAL
Basic Operation
Here are some of the features available during Dual Receive operation:
U Press the [M/S(SUB SET)] key momentarily to toggle the operating VFO between
the MAIN VFO and SUB VFO.
U When tuning on the MAIN VFO, the SUB VFO frequency will track the MAIN VFO
(VFO Tracking feature). To disable the VFO Tracking feature, press the
[M/S(SUB SET)] key after the [F] key is pressed. Repeat the same procedure to
re-enable the VFO Tracking feature again.
U To disable the SUB VFO, and erase its contents, press the [CLR(PRI CLR)] key
after the [F] key is pressed. Pressing the [M/S(SUB SET)] key will re-activate
the SUB VFO. When the SUB VFO re-appears, it will have been reset to the MAIN
VFO’s frequency.
U Press the [COPY(REC)] key to copy the SUB VFO’s frequency data to the MAIN
VFO.
SETTING THE CLOCK
1. Press the [F] key momentarily, then press the [ENT] key. 2. Rotate the
DIAL knob to set the cursor to the “MISC” menu, then press the [ENT] key. 3.
Rotate the DIAL knob to set the cursor to the “CLOCK” menu option, then press
the
[ENT] key. 4. Enter the present time via the keypad.
Example 1: Set to 9:38, Press [0] ¯ [9] ¯ [3] ¯ [8].
Example 2: Set to 13:20, Press [1] ¯ [3] ¯ [2] ¯ [0].
5. Rotate the DIAL knob to set the cursor to the “END” menu option, then
press the [ENT(SET)] key.
6. Confirm that the cursor is on the “WRITE” menu option, then press the
[ENT] key. 7. Press the [F] key momentarily, then press the press the [4(SPL)]
key. 8. Rotate the DIAL knob to set the cursor to the “UTC set” menu option,
then press the
[ENT(SET)] key. The World Clock and its accompanying World Atlas will appear.
9. Rotate the DIAL knob to select the desired area. 10. Press the [F] key
momentarily, then press the press the [9(TIMER)] key. 11. Press the [CLR(PRI
CLR)] key then press the [ENT(SET)] key. 12. Setup of the clock is now
complete.
VR-5000 OPERATING MANUAL
17
Basic Operation
RECEIVING SHORT-WAVE BROADCAST STATIONS
A special bank of prominent Short-wave Broadcast stations has been pre-
programmed at the factory, for quick tuning. Each station selection will have
been programmed with four of its most-often used frequencies, representing
both night-time frequencies (generally below 10 MHz) and day-time frequencies
(generally above 10 MHz).
Of course, you are not “required” to listen just to these stations; many other
stations will be found in the frequencies adjacent to those stored in the
special Short-wave Broadcast Memory Bank. However, the pre-programmed stations
will provide a “quick start” to your Short-wave listening enjoyment!
To utilize the pre-programmed Short-wave Broadcast Memory Bank: 1. Press the
[F] key momentarily, then press the [6(S.CALL)] key to recall the special
Short-Wave Broadcast Station Memory Bank. 2. Press the [T(W)/S(X)] keys to
select the desired Broadcast Station. 3. Rotate the DIAL knob to select the
Broadcast Station’s frequency from among the pre-
programmed choices. At different times of the day, different frequencies will
be optimum for each station. 4. To exit from the special Short-wave Broadcast
Station Memory Bank, press the [CLR(PRI CLR)] key.
18
VR-5000 OPERATING MANUAL
Basic Operation
You can change the frequencies of stations in the above frequency list, if
desired.
Here is the procedure:
1. Tune the radio to the new frequency of the Broadcast Station on the list.
2. Press the [F] key momentarily, then press the [4(SPL)] key. 3. Rotate the
DIAL knob to set the cursor to the “STATION FREQ. WRITE” menu, then
press the [ENT(SET)] key. 4. Press the [T(W)/S(X)] keys to select the
Broadcast Station whose frequency is to be
changed. 5. Rotate the DIAL knob to select the frequency (on that station’s
list) to be changed, then
press the [ENT] key. 6. Confirm that the cursor is on the “WRITE” menu, then
press the [ENT] key to update
the list reflect the new frequency.
Bank 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
Display VOA R-CANADA R-PORTUG SPAIN BBC R-FRANCE BELGIUM R-NEDERL R-LUXEMB D-WELLE SWISS-R R-NORWAY ITARY R-DENMAR R-SWEDEN R-FINLAN ISRAEL RUSSIA INDIA CHINA-R R-KOREA R-JAPAN R-AUSTRA
Short-wave Broadcast Station List
Station’s Name Voice Of America Radio Canada International Radio Portugal Radio Exterior de España British Broadcasting Corporation Radio France International Radio Vlaanderen International Radio Nederland Radio Luxembourg Deutsche Welle Swiss Radio International Radio Norway International Italian Radio International (RAI) Radio Denmark Radio Sweden Radio Finland Israel Broadcasting Authority Voice of Russia All India Radio (AIR) China Radio International (CRI) Radio Korea Radio Japan Radio Australia
Frequency (MHz) 6.030/6.160/9.760/11.930 5.995/7.235/9.735/11.705 9.780/11.960/15.555/21.655 7.270/9.520/11.920/15.585 6.195/9.410/12.095/15.310 6.045/9.790/11.670/15.525 5.985/9.925/11.780/13.740 5.955/6.020/9.895/11.655 6.090 3.955/6.075/9.545/9.735 3.985/6.165/9.885/15.220 7.485/9.590/9.985/13.800 6.060/7.175/9.515/17.710 9.590/9.985/13.800/15.735 6.065/9.490/13.625/17.505 6.120/9.630/9.795/11.755 9.435/11.585/15.615/17.545 5.920/5.940/7.205/12.030 6.045/9.595/11.620/15.020 5.250/7.190/9.855/11.685 5.795/7.275/9.570/13.670 6.155/7.200/9.750/11.850 5.995/9.580/9.660/12.080
VR-5000 OPERATING MANUAL
19
Memory Operation
The VR-5000 provides a wide variety of memory system resources. These include:
U 2000 main memory channels, which may be separated into as many as 100 memory
groups. U 50 sets of band-edge memories (also known as “Programmable Memory
Scan” channels). U Five PS (Pre Set) memory channels, providing one-touch
storage and recall of prime
receiving frequencies.
MAIN MEMORY SYSTEM
Memory Storage
1. Select the desired frequency, while receiving on the MAIN VFO. Be sure to
set up any special features (described later), if you wish to store them.
2. Press the [F] key momentarily, then press the [V/M(MW)] key to enable the
memory storage process.
3. To designate the channel for storage into a particular memory group,
proceed to the next step; otherwise press the [COPY(REC)] key twice to save
the entry and exit to the VFO mode. If you are not designating the channel
into a memory group, storage of this frequency is now complete.
4. If designating the channel for storage into a memory group, confirm that
the cursor is on the “Channel” menu, then press the [ENT] key.
5. Press the [T(W)/S(X)] keys to select the desired memory group to be
stored, then press the [ENT] key. Pressing the [T(W)] key once will select an
all-new memory group, if this is what you want to do.
6. Rotate the DIAL knob one click to the right to set the cursor to the
“Channel” menu, then press the [COPY] key.
7. Confirm that the cursor has switched to the “WRITE” menu selection, then
press the [ENT] key to save the entry and exit to the VFO mode.
Memory Recall
1. While operating in the VFO mode, press the [V/M(MW)] key to switch to the “memory”
mode. 2. Press the [S(X)/T(W)] keys to select the desired memory group, or press the desired
memory group number from the keypad (include any leading zeroes: press [0] ¯ [2]
for memory group 2).
3. Now rotate the DIAL knob to select the desired memory channel within the selected
memory group.
4. To return to the VFO mode, press the [V/ M(MW)] key again.
Memory Bank “00” Memory Channel “01”
20
VR-5000 OPERATING MANUAL
Memory Operation
You can also configure the VR-5000 for recall of all memory channels (ignoring
the memory groups). To do this:
(1) Press the [F] key momentarily, then press the [ENT(SET)] key. (2) Rotate
the DIAL knob to set the cursor to the “MR” menu, then press the [ENT] key.
(3) Confirm that the cursor is on the “MR BANK”
menu selection, then press the [· (BEEP)] key to change its setting to “All
Mem.” (4) Rotate the DIAL knob to set the cursor to the “END” menu selection,
then press the [ENT] key. (5) Confirm that the cursor is on the “WRITE” menu,
then press the [ENT] key to save the entry and exit. You can now select any of
the programmed memory channels by just rotating the DIAL knob.
If you set the “MR BANK” menu selection to the “In BANK” option in step (3),
the receiver will return to memory selection within memory groups, using the
[T(W)/S(X)] keys for memory group selection and the DIAL knob for memory
channel selection.
VR-5000 OPERATING MANUAL
21
Memory Operation
ENHANCED MEMORY CHANNEL OPERATION
Memory Offset Tuning
Once you have recalled a particular memory channel, you may easily tune off
that channel, as through you were in the “VFO” mode. 1. With the VR-5000 in
the memory mode, select the desired memory channel. 2. Press the [BS(BS
SET)MT] key momentarily. 3. Rotate the DIAL knob or press the [T(W)/S(X)]
keys, as desired, to tune to a new
frequency. 4. If you wish to return to the original memory frequency, press
the [V/M(MW)] key
momentarily. 5. Press the [COPY(REC)] key to return to the VFO on the new
frequency set during
Memory Tuning.
Naming Memories
You may wish to append an alpha-numeric “Tag” (label) to a memory or memories,
to aid in recollection of the channel frequency’s identity (such as a Short-
wave Broadcast station’s name, etc.).
1. Recall the memory channel on which you wish to append a label. 2. Press
the [F] key momentarily, then press the [V/M(MW)] key. 3. Rotate the DIAL knob
to set the cursor to the “CH TAG” menu, then press the
[ENT(SET)] key to enable programming of the name tag into the memory. 4. Press
the keypad to select the first digit of the desired label, according to the
key entry
rule described below. When you have made your selection, rotate the DIAL knob
clockwise one click to move to the next character. 5. Repeat the previous step
to program the remaining letters, numbers, or symbols of the desired label. A
total of 74 characters may be used in the creation of label. 6. When you have
completed the label, press the [ENT(SET)] key. 7. Rotate the DIAL knob to set
the cursor to the “END” menu selection, then press the [ENT(SET)] key. 8.
Confirm that the cursor is on the “WRITE” menu option, then press the [ENT]
key. 9. The naming of the memory is now complete.
22
VR-5000 OPERATING MANUAL
Memory Operation
Alpha-Numeric Keypad Sequence
U Press the [1(ATT)] key repeatedly to toggle between the two available
characters: “1” ¯ “Space” ¯ “1” ……
U Press the [2(LOCK)] key repeatedly to toggle among the seven available
characters: “2” ¯ “A” ¯ “B” ¯ “C” ¯ “a” ¯ “b” ¯ “c” ¯ “2” ¯ “A” ……
U Press the [3(S.SCH)] key repeatedly to toggle among the seven available
characters: “3” ¯ “D” ¯ “E” ¯ “F” ¯ “d” ¯ “e” ¯ ” f ” ¯ “3” ¯ “D” ……
U Press the [4(SPL)] key repeatedly to toggle among the seven available
characters: “4” ¯ “G” ¯ “H” ¯ ” I ” ¯ “g” ¯ “h” ¯ ” i ” ¯ “4” ¯ “G” ……
U Press the [5(PRI)] key repeatedly to toggle among the seven available
characters: “5” ¯ “J” ¯ “K” ¯ “L” ¯ ” j ” ¯ “k” ¯ “l” ¯ “5” ¯ “K” ……
U Press the [6(S.CALL)] key repeatedly to toggle among the seven available
characters: “6” ¯ “M” ¯ “N” ¯ “O” ¯ “m” ¯ “n” ¯ “o” ¯ “6” ¯ “M” ……
U Press the [7(VCS)] key repeatedly to toggle among the seven available
characters: “7” ¯ “P” ¯ “Q” ¯ “R” ¯ “p” ¯ “q” ¯ “r” ¯ “7” ¯ “P” ……
U Press the [8(RF TUNE)] key repeatedly to toggle among the seven available
characters: “8” ¯ “S” ¯ “T” ¯ “U” ¯ “s” ¯ “t” ¯ “u” ¯ “8” ¯ “S” ……
U Press the [9(TIMER)] key repeatedly to toggle among the seven available
characters: “9” ¯ “V” ¯ “W” ¯ “X” ¯ “v” ¯ “w” ¯ “x” ¯ “9” ¯ “V” ……
U Press the [0(NB)] key repeatedly to toggle among the five available
characters: “0” ¯ “Y” ¯ “Z” ¯ “y” ¯ “z” ¯ “0” ¯ “Y” ……
U Press the [DSP] key repeatedly to toggle among the 11 available symbols: ” !
” ¯ ” ” ” ¯ “$” ¯ “%” ¯ “&” ¯ ” ‘ ” ¯ ¯ ” ( ” ¯ ” ) ” ¯ “*” ¯ “+” ¯ ” : ” ¯ ”
! “…
U Press the [BS] key to delete the character before the cursor. U Press the
[T(W)] key to move the cursor to the left. U Press the [S(X)] key to move the
cursor to the right. U Press the [CLR(PRI CLR)] key to cancel the creation of
the label. U Press the [CLR(PRI CLR)] key, after the [F] key is pressed, to
cancel the all charac-
ters.
VR-5000 OPERATING MANUAL
23
Memory Operation
Naming Memory Groups
1. Press the [V/M(MW)] key, if needed, to enter the memory mode. 2. Recall
the memory group to which you wish to append a label, then press the [BANK]
key. 3. Confirm that the cursor is on the “BANK TAG”
menu, then press the [ENT(SET)] key. 4. Program the alpha-numeric “label”
which you
wish to recall using the DIAL knob and keypad, as described previously. 5.
When you have completed the creation of the label, press the [ENT(SET)] key.
6. Rotate the DIAL knob to set the cursor to the “END” menu selection, then
press the [ENT(SET)] key. 7. Confirm that the cursor is on the “WRITE” menu
option, then press the [ENT(SET)] key. 8. The memory group naming process is
now complete.
Protecting Memories (Inhibits the Editing of Memorized
Channels)
You may wish to “Protect” a certain Memory Channel’s data, to prevent
accidental data change. With Protection activated, you will not be able to
edit or replace that channel’s data.
To Protect a channel’s data:
1. Recall the Memory Channel to be protected. 2. Press the [F] key
momentarily, then press the [V/M(MW)] key. 3. Rotate the DIAL knob to set the
cursor to the “END” menu selection, then press the
[ENT(SET)] key. 4. Rotate the DIAL knob to set the cursor to the
“PROTECT” menu, then press the [ · (BEEP)] key to change its setting to
“PROTECT.” 5. Rotate the DIAL knob to set the cursor to the “WRITE” menu
option, then press the [ENT(SET)] key to protect the channel’s data.
If you set the “PROTECT” menu to “FREE” in step 4, the memory protection
feature will be disabled.
24
VR-5000 OPERATING MANUAL
Memory Operation
Masking Memories
You may wish to “Mask” a certain Memory Channel’s data, when you no longer
have a reason to recall that channel.
To Mask a channel’s data:
1. Recall the Memory Channel to be masked. 2. Press the [F] key momentarily,
then press the [V/M(MW)] key. 3. Rotate the DIAL knob to set the cursor to the
“Channel” menu, then press the
[ENT(SET)] key. 4. Press the [F] key momentarily, then press the [CLR(PRI
CLR)] key. 5. Confirm that the cursor is on the “DELETE”
menu selection, then press the [ENT(SET)] key. 6. Press the [CLR(PRI CLR)]
key. 7. Confirm that the cursor is on the “CANCEL” menu option, then press the
[ENT(SET)] key to mask the channel’s data.
To unmask a channel’s data:
1. Press the [F] key momentarily, then press the [V/M(MW)] key. 2. Rotate the
DIAL knob to set the cursor to “Channel” menu, then press the [ENT(SET)] key.
3. Select the masked memory using the [T(W)/S(X)] keys and DIAL knob. The
masked
memory appears with a “Q” icon in the lower left corner of the LCD. 4. Press
the [F] key momentarily, then press the [CLR(PRI CLR)] key. 5. Rotate the DIAL
knob to set the cursor to the
“OLD READ” menu selection, then press the [ENT(SET)] key. 6. Rotate the DIAL
knob to set the cursor to the “END” menu, then press the [ENT(SET)] key. 7.
Confirm that the cursor is on the “WRITE” menu option, then press the
[ENT(SET)] key to unmask the channel.
VR-5000 OPERATING MANUAL
25
Memory Operation
Alpha-Numeric Memory Recall
You can use the VR-5000’s powerful microprocessor system to search for Memory
Channels according to their alpha-numeric label. In the example below, we
shall set up the VR5000 to find all channels programmed with “POLICE” as an
alpha-numeric label (e.g. POLICE 1, POLICE 2, etc.).
1. Press the [V/M(MW)] key, if needed, to enter the memory mode. 2. Press the
[WIDTH(BS STEP)] key to enable setup of Alpha-Numeric Memory Re-
call. 3. Program the alpha-numeric “label” which you wish to recall, using the
DIAL knob and
keypad, as described previously. In this case, program “POLICE” as the label.
Note: do not press [ENT(SET)] after completing entry of the desired “label” in
this
instance. 4. Press the [M/S(SUB SET)SORT] key, which will recall the first
memory channel
beginning with “POLICE.” The channel found will appear at the bottom left-hand
portion of the display. 5. Press the [M/S(SUB SET)SORT] key; you will observe
that only channels beginning with “POLICE” are appearing on the display. 6.
When you find the desired memory channel, press the [ENT(SET)] key to recall
that channel.
Important Note: You can recall Memory Channels alpha-numerically using just
one or two letters of a label within above steps. In the above example, if you
programmed “PO” instead of “POLICE,” you could then recall channels such as
“PONTIAC,” “PORTER,” “PORTLAND,” and “POLAND” in addition to “POLICE.” But if
you set “POR,” only “PORTER” and PORTLAND” would be recalled.
PROGRAMMABLE MEMORY RECALL
The VR-5000 can be set up to monitor the activity on as many as 50 memory
channels simultaneously. For example, repeater system owners may wish to
observe channel loading on the various repeaters in the system, and the
VR-5000 can assist in this effort. A graphical representation of channel
occupancy will be created, called the “PMR Board.”
When you install the memory channels you wish to observe into the PMR Board,
the VR-5000 will monitor the activity on these channels simultaneously via a
rapid search function.
Then an “indicator” will appear on the board, as described below, letting you
know that activity was noted on that channel.
26
VR-5000 OPERATING MANUAL
Memory Operation
To install a Memory Channel into the PMR Board: 1. Recall the memory channel
which you wish to be monitoring for activity. 2. Press the [F] key
momentarily, then press the [3(S.SCH)] key. 3. The next-available PMR Board
channel slot will be displayed, with an arrow alongside
it. Press the [· (BEEP)] key to store the current channel. 4. Rotate the DIAL
knob to set the cursor to the “END” menu selection, then press the
[ENT(SET)] key. 5. Confirm that the cursor is on the “WRITE” menu selection,
then press the [ENT(SET)] key to install the memory channel into the PMR
Board. 6. Repeat steps 1 ~ 5 to install any other desired memory channels (up
to 50 channels)
into the PMR Board.
To monitor the PMR Board: Before commencing operation in this mode, be sure
that the SQL control is set up so as to quiet the background noise.
1. Press the [F] key momentarily, then press the [4(SPL)] key. 2. Rotate the
DIAL knob to set the cursor to the “PMR Board” menu selection, then press
the [ENT(SET)] key. 3. The PMR Board will now be displayed as a matrix of
channel squares. The “White”
squares indicate vacant channels, and Black squares indicate occupied
channels. 4. Press the [CLR(PRI CLR)] key, followed by the [ENT(SET)] key, to
return to the
Memory mode.
To delete a memory channel from the PMR Board: 1. Recall the Memory Channel
mode. 2. Press the [F] key momentarily, then press the [3(S.SCH)] key. 3.
Rotate the DIAL knob to set the cursor to the memory channel which you wish to
delete
from the PMR Board, then press the [· (BEEP)] key. 4. Rotate the DIAL knob to
select the cursor to the “END” menu, then press the [ENT(SET)] key. 5. Confirm
that the cursor is on the “WRITE” menu, then press the [ENT(SET)] key to
delete the memory channel from the PMR Board and return to the Memory mode.
VR-5000 OPERATING MANUAL
27
Memory Operation
MEMORY CHANNEL SORT
The VR-5000 can also sort the memory channels according to “Alpha-Numeric Name
Tag,” “Frequency,” “Receive mode,” or “Channel Number.” When this is done, the
memory channel numbers will be re-arranged to reflect the new lineup of the
memorized channels.
Sorting by Alpha-Numeric Name Tag: 1. Recall the Memory mode. 2. Press the
[M/S(SUB SET)] key, then rotate the DIAL knob to set the cursor to the
“TAG NAME” menu. 3. Press the [· (BEEP)] key to set the sorting mode to “A ->
Z” or “Z -> A.”
A -> Z: Arranges the memory channels from A to Z (first letter of name). Z ->
A: Arranges the memory channels from Z to A (first letter of name).
4. Press the [ENT(SET)] key to initiate the sort.
Sorting for the Receiving Frequency: 1. Recall the Memory mode. 2. Press the
[M/S(SUB SET)] key, then rotate the DIAL knob to set the cursor to the
“FREQUENCY” menu. 3. Press the [· (BEEP)] key to select the sorting mode to “A
-> Z” or “Z -> A.”
A -> Z: Arranges the memory channels from the lowest frequency to the highest
frequency.
Z -> A: Arranges the memory channels from the highest frequency to the lowest
frequency.
4. Press the [ENT(SET)] key to initiate the sort.
Sorting for the Receiving Mode: In this configuration, the channels are sorted according to the way the receiving modes appear on the display; “A -> Z” corresponds to “Left to Right” on the display, while “Z -> A” corresponds to “Right to Left” on the display.
1. Recall the Memory mode. 2. Press the [M/S(SUB SET)] key, then rotate the
DIAL knob to set the cursor to the “Rx
MODE” menu. 3. Press the [· (BEEP)] key to set the sorting mode to “A -> Z” or
“Z -> A.”
A -> Z: Sorts the memory channels as following order:
AUTO ¯ LSB ¯ USB ¯ CW ¯ AM-N ¯ AM ¯ WAM ¯ FM-N ¯ WFM
Z -> A: Sorts the memory channels as following order: WFM ¯ FM-N ¯ WAM ¯ AM ¯
AM-N ¯ CW ¯ USB ¯ LSB ¯ AUTO
4. Press the [ENT(SET)] key to initiate the sort.
28
VR-5000 OPERATING MANUAL
Memory Operation
Sorting for the Channel Number ( deletes the vacant memories automatically):
- Recall the Memory mode. 2. Press the [M/S(SUB SET)] key, then rotate the
DIAL knob to set the cursor to the
“CHANNEL” menu. 3. Press the [· (BEEP)] key to set the sorting mode to “A -> Z” or “Z -> A.”
A -> Z: Sorts the memory channels in ascending channel number order (any vacant memory channels are deleted automatically).
Z -> A: Sort the memory channels in descending channel number order (any vacant memory channels are deleted automatically).
4. Press the [ENT(SET)] key to initiate the sort.
(Note: The “ascending” or “descending” channel number order in this mode refers to the order in which the channels originally were stored. )
Note: When you initiate Channel Number Sorting, the VR-5000 can not recall Masked memory channels.
PS (PRESET) MEMORY CHANNELS
Five convenient PS memories are provided in the VR-5000, allowing quick recall of toppriority operating frequencies. Use this memory feature for your most- often-used frequencies.
PS Memory Channel Storage
1. In the VFO mode, tune the VR-5000 to the desired frequency.
2. Press and hold the [PS] key for one second. 3. Press the [PS] key momentarily (repeatedly, if
necessary) to select the PS channel into which you wish to store the current frequency data. 4. Press and hold the [PS] key for one second to enable the programming of a name tag to the PS memory. To attach an alpha/numeric name to the PS memory, proceed to the programming of the name tag as described previously; otherwise press the [ENT(SET)] key. 5. Press the [ENT(SET)] key again to finish the PS Memory Channel storage.
PS Memory Channel Recall
1. Press the [PS] key to recall the currently active PS Memory Channel. 2. Press the [PS] key repeatedly to cycle through the PS Memory Channels. 3. Rotate the DIAL knob to exit the PS Memory Channel bank and return to the VFO or
Memory mode.
VR-5000 OPERATING MANUAL
29
Scanning
The VR-5000 allows you to scan just memory channels, the entire operating
band, or a portion of that band. It will halt on signals encountered, so you
can listen to the station(s) on that frequency, if you like.
Scanning operation is basically the same in each of the above modes. There are
customized settings for each scanning mode, however, that you need to set up
according to your operating preferences. Before you begin, take a moment to
select the way in which you would like the scanner to (A) stop scanning when
it halts on a signal and (B) resume scanning after it halts on a signal.
Setting the Scan-Stop Technique
During Memory Channel Scanning, three options for the Scan-Stop mode are
available:
NORMAL: In this mode, the scanner will stop on a signal it encounters
(default). S-METER: In this mode, the scanner will stop on a signal exceeding
a prescribed S-meter
level (at which the squelch opens). VOICE: In this mode, the scanner will stop
on a signal which contains a voice signal.
Here is the procedure for setting up the Scan-Stop mode:
S-METER Scanning 1. Press the [F] key momentarily, then press the [V/M(MW)]
key. 2. Rotate the DIAL knob to set the cursor to the “Channel” menu option,
then press the
[ENT(SET)] key. 3. Using the [T(W)/S(X)] keys or the keypad, select the memory
bank on which you
wish to perform S-METER scanning, then press the [BANK] key. Each bank must be
set separately. 4. Rotate the DIAL knob to set the cursor to the “S-LvlScan”
menu option, then press the [ · (BEEP)] key to enable setup of S-METER level
scanning. 5. Press the [ENT(SET)] key, then rotate the DIAL knob to set the
desired scan-stop (squelch opening) threshold to the desired signal strength
“65” ~ “255,” then press the [ENT(SET)] key. The 65 ~ 255 scale is arbitrary,
and you may need to experiment to find the level which is optimum for your
operating needs. 6. Rotate the DIAL knob to set the cursor to the “END” menu
option, then press the [ENT(SET)] key. 7. Confirm that the cursor is on the
“WRITE” menu option, then press the [ENT(SET)] key to save the new setting and
exit to normal operation.
30
VR-5000 OPERATING MANUAL
Scanning
VOICE Scanning 1. Press the [F] key momentarily, then press the [V/M(MW)] key.
2. Rotate the DIAL knob to set the cursor to the “Channel” menu option, then
press the
[ENT(SET)] key. 3. Using the [T(W)/S(X)] keys or the keypad, select the memory
bank on which you
wish to perform VOICE scanning, then press the [BANK] key. 4. Rotate the DIAL
knob to set the cursor to the
“VCS” menu option, then press the [· (BEEP)] key to enable VOICE scanning. 5.
Rotate the DIAL knob to set the cursor to the “END” menu option, then press
the [ENT(SET)] key. 6. Confirm that the cursor is on the “WRITE” menu option,
then press the [ENT(SET)] key to save the new setting and exit to normal
operation.
Setting the Scan-Resume Technique
Three options for the Scan-Resume technique are available. These options may
be set independently for Memory Scan, VFO Scan, and PMS (Band-Segment) Scan
operation.
DELAY: In this mode, the scanner will halt on a signal it encounters, and will
hold until the signal disappears. After the squelch closes when the received
station quits transmitting, scanning resumes automatically. The scanning-
restart delay time (default interval: 2 seconds) is set by the “M-P.DELAY”
menu selection.
PAUSE: In this mode, the scanner will halt on a signal it encounters. After a
programmed time interval (set by the “M-PAUSE” menu selection), the scanner
will resume, whether or not the signal has disappeared.
HOLD: In this mode, the scanner will halt on a signal it encounters. It will
not restart automatically; you must manually re-initiate scanning if you wish
to resume. However, the “M-HOLD” menu selection provides a “restart” window
within which, if the incoming signal disappears, the scanner will resume; this
allows scanning to proceed if the squelch is opened by a brief incoming signal
burst.
Here is the procedure for setting up the Scan-Resume mode for Memory scanning:
- Press the [V/M(MW)] key, if necessary, to enter the “MR” (Memory Recall)
mode. 2. Use the [T(W)/S(X)] keys to select the desired memory bank. 3. Press
the [BANK] key, then rotate the dial to select the “ScanStop” menu option. 4.
Press the [ · (BEEP)] key, repeatedly if necessary, to select “DELAY,”
“PAUSE,” or
“HOLD,” as desired. 5. Rotate the DIAL knob to select “END,” then press the [ENT(SET)] key. 6. The display should now indicate “WRITE;” press the [ENT(SET)] key again to save
the new setting and exit to normal operation .
VR-5000 OPERATING MANUAL
31
Scanning
Here is the procedure for setting up the Scan-Resume mode for VFO scanning: 1.
Press the [F] key momentarily, then press the [ENT(SET)] key. 2. Confirm that
the cursor is on the “VFO” menu option, then press the [ENT(SET)] key. 3. If
you are setting the Scan-Resume mode for the MAIN VFO, rotate the dial to put
the
cursor on the “MainScan” menu option. 4. Press the [· (BEEP)] key to select
the desired Scan-Resume mode: “DELAY,” “PAUSE,”
or “HOLD.” 5. Rotate the DIAL knob to set the cursor to the “END” menu option,
then press the
[ENT(SET)] key. 6. Confirm that the cursor is on the “WRITE” menu option, then
press the [ENT(SET)] key to save a new setting and exit.
Here is the procedure for setting up the Scan-Resume mode for PMS scanning: 1.
Press the [PMS(PMS SET)] key to enter the “PMS” mode (described below). 2.
Press the [SCAN(M-S SCAN)] key to halt PMS scanning, if engaged. 3. Press the
[F] key momentarily, then press the [PMS(PMS SET)] key. 4. Rotate the DIAL
knob to select the “MISC” menu option, then press [ENT(SET)]. 5. Rotate the
DIAL knob to select the “ScanStop” menu option. 6. Press the [ · (BEEP)] key,
repeatedly if necessary, to select “DELAY,” “PAUSE,” or
“HOLD,” as desired. 7. Rotate the DIAL knob to select “END,” then press
[ENT(SET)]. 8. The display should now indicate “WRITE;” press the [ENT(SET)]
key again to save
the new setting and exit to normal operation.
MEMORY SCANNING
1. Press the [V/M(MW)] key, if needed, to enter the “MR” (Memory Recall)
mode. 2. Press the [T(W)/S(X)] keys to select the memory bank on which you
wish to do
memory channel scanning. 3. Press the [SCAN(M-S SCAN)] key to initiate memory
channel scanning in an upward
direction (in the current memory bank). 4. If the scanner encounters a signal
strong enough to open the squelch, the scanner will
halt and pause on that channel. Scanning will resume according to the protocol
you selected in the previous discussion. 5. To reverse the direction of the
scan (i.e. toward a lower memory channel, instead of a higher memory channel),
turn the DIAL knob one click in the counter-clock direction (or press the
[T(W)] key momentarily) while the VR-5000 is scanning. To revert to scanning
toward a higher memory channel once more, rotate the DIAL knob one click
clockwise (or press the [S(X)] key momentarily). 6. Press the [SCAN(M-S SCAN)]
key to disable memory channel scanning.
32
VR-5000 OPERATING MANUAL
Scanning
If you wish to have the memory channel scanner sweep all memories (in all
memory banks): (1) Press the [F] key momentarily, then press the [ENT(SET)]
key. (2) Rotate the DIAL knob to set the cursor to the “MR” menu option, then
press the
[ENT(SET)] key. (3) Confirm that the cursor is on the “MR BANK”
menu option, then press the [· (BEEP)] key to change its setting to “All Mem.”
(4) Rotate the DIAL knob to set the cursor to the “END” menu option, then
press the [ENT] key. (5) Confirm that the cursor is on the “WRITE” menu
option, then press the [ENT] key to save the entry and exit. (6) Press the
[SCAN(M-S SCAN)] key to initiate memory channel scanning in an upward
direction on the all memories (in all memory banks).
If you set the “MR BANK” menu option to “In BANK” in step (3), it will return
the memory channel scanner to sweeping within the current memory bank only.
Memory Channel Skip
As mentioned previously, some continuous-carrier stations like a Broadcast
station will seriously impede scanner operation if you are using the “PAUSE”
Scan-resume mode, as the incoming signal will not pause long enough for the
receiver to resume scanning. Such channels may be “skipped” during scanning,
if you like.
1. Recall the Memory Channel to be skipped during scanning. 2. Press the
[CLR(PRI CLR)] key. The “SKIP” icon will appear in place of the “SEL”
icon (just to the left of the channel number on the display). 3. To cancel the
memory channel skip programming for a particular channel, repeat the
above steps so that the “SEL” icon appears in place of the “SKIP” icon.
VFO SCANNING
1. Press the [V/M(MW)] key to recall the VFO mode, if needed. 2. Press the
[SCAN(M-S SCAN)] key to initiate scanning in an upward direction.
3. If the scanner encounters a signal strong enough to open the squelch, the
scanner will halt and pause on that frequency. Scanning will resume according
to the protocol you selected in the previous discussion.
4. To reverse the direction of the scan (i.e. toward a lower frequency,
instead of a higher frequency), turn the DIAL knob one click in the counter-
clock direction or press the [T(W)] key momentarily (while the VR-5000 is
scanning). To revert to scanning toward a higher frequency once more, rotate
the DIAL knob one click clockwise (or press the [S(X)] key momentarily).
5. Press the [V/M(MW)] key to disable the scanner.
VR-5000 OPERATING MANUAL
33
Scanning
PROGRAMMABLE (BAND LIMIT) MEMORY SCAN (PMS)
This feature a more refined and useful form of VFO scanning, allows you to
establish subband limits for scanning. This allows you to monitor only a
portion of the wide frequency range of the VR-5000, instead of sweeping the
entire spectrum from 100 kHz to 2.6 GHz.
Programmable Memory Scan utilizes a pair of special memories to establish the
upper and lower scanning limits. Here is the procedure for setting up limited
band scanning:
Programming
1. Press the [F] key momentarily, then press the [PMS(PMS SET)] key to enable
the storage of the frequency pair into a PMS memory.
2. The cursor will be pointing at the “PMS CH” menu option; press the
[ENT(SET)] key. 3. If you want to program the frequency pair into the
currently-selected PMS register
(shown on the right edge of the display), proceed to the next step; if you
wish to choose a different PMS register, press [ENT(SET)], then use the
[T(W)/S(X)] keys to select a different memory register number. Then press
[ENT(SET)] to move on to the next step. 4. Rotate the DIAL knob to set the
cursor to the “PMS TAG” menu option. 5. Press the [ENT(SET)] key to enable the
programming of the name tag to the PMS memory. To attach an alpha/numeric name
tag to the PMS memory, program the alphanumeric “label” using the DIAL knob
and keypad, as described previously; if you don’t want to label this frequency
pair register, press the [ENT(SET)] key again. 6. When you have complete the
creation of the label, press the [ENT(SET)] key. 7. Now it’s time to set up
the band limits. Rotate the DIAL knob to set the cursor to the “START F” menu
option, then press the [ENT(SET)] key. 8. Set the VFO frequency to the Lower
sub-band limit, then press the [ENT(SET)] key. 9. Confirm that the cursor is
on the “END F” menu, then press the [ENT] key. 10. Select the VFO frequency to
the Upper sub-band limit, then press the [ENT(SET)] key. 11. Rotate the DIAL
knob to set the cursor to the “END” menu option, then press the [ENT(SET)]
key. 12. Confirm that the cursor is on the “WRITE” menu option, press the
[ENT(SET)] key. 13. The PMS memory programming process is now completed.
Note: 50 PMS memories are available. You therefore can set upper and lower
operation limits on a number of bands, if you like.
Operation (Current PMS Register)
1. Press the [PMS(PMS SET)] key to initiate PMS scanning in an upward
direction. 2. If the scanner encounters a signal strong enough to open the
squelch, the scanner will
halt and pause on that frequency. Scanning will resume according to the
protocol you selected in the previous discussion.
34
VR-5000 OPERATING MANUAL
Scanning
3. To change to a different PMS frequency pair, press the numerical keys on
the keypad
corresponding to the PMS register you wish to use. For example, if you are on
PMS register “00” and wish to use PMS register “03,” press [0] ¯ [3] while PMS
scanning
is engaged. Scanning will begin on the new register without further action.
4. To reverse the direction of the scan (i.e. toward a lower frequency,
instead of a higher frequency), turn the DIAL knob one click in the counter-
clock direction or press the [T(W)] key momentarily while the VR-5000 is
scanning. To revert to scanning toward a higher frequency once more, rotate
the DIAL knob one click clockwise or press the [S(X)] key momentarily.
5. Press the [V/M(MW)] key to disable the PMS scanner, and return to VFO
mode.
Adjusting the PMS Scanner (Including PMS Register Change)
1. Press the [F] key momentarily, then press the [PMS(PMS SET)] key. 2. To
change the PMS register on which you wish to scan, first confirm that the
cursor is
pointing to “PMS CH,” then press the [ENT(SET)] key. 3. Rotate the DIAL knob
to select the new PMS register; now press the [ENT(SET)] key. 4. If you only
wish to change the PMS register, skip to step 7. 5. Rotate the DIAL knob to
set the cursor to the “MISC” menu option, then press the
[ENT(SET)] key. 6. Rotate the DIAL knob to set the cursor to the desired menu
from the following list;
remember that these settings will only be applied during PMS operation.
ScanStop: Selects the Scan Resume mode among “HOLD,” “DELAY,” and “PAUSE,”
as described previously. Press the [· (BEEP)] key to change selections.
(1) In the “HOLD” mode, when a signal is received the scanner will hold for
2 second, then the scanner will stop.
(2) In the “DELAY” mode, when a signal is received the scanner will hold
until the signal disappears, then the scanner will resume after 2 seconds.
(3) In the “PAUSE” mode, when a signal is received the scanner will hold
for 2 second, then scanner will resume after 2 seconds.
S-LvlScan: The scanner will halt and pause on the frequency when there is a signal
strong enough to stops on.
VCS:
Enables/disables the VCS (Voice Channel Scan) feature via pressing the [·
(BEEP)] key. When enable the VCS feature is enabled, the scanner will
only halt and pause on the frequency that is having the voice signal.
ATT:
Enable/disable the RF signal Attenuator via pressing the [· (BEEP)] key.
DSP: Turns the Digital Signal Processing system On or Off.
7. When you have made your selection(s), rotate the DIAL knob to select the “END”
menu option, then press the [ENT(SET)] key.
8. Confirm that the cursor is now pointing to the “WRITE” menu option, and press the
[ENT(SET)] key.
VR-5000 OPERATING MANUAL
35
Scanning
M-S SCAN
This feature allows you to sub-band limits scanning between the MAIN VFO
frequency and SUB VFO frequency.
1. Press the [V/M(MW)] key to recall the VFO mode, if necessary. 2. Press the
[F] key momentarily, then press the [SCAN(M-S SCAN)] key to initiate
scanning in an upward direction between the MAIN VFO frequency and SUB VFO
frequency. 3. If the scanner encounters a signal strong enough to open the
squelch, the scanner will halt and pause on that frequency. 4. To reverse the
direction of the scan (i.e. toward a lower frequency, instead of a higher
frequency), turn the DIAL knob one click in the counter-clock direction or
press the [T(W)] key momentarily while the VR-5000 is scanning. To revert to
scanning toward a higher frequency once more, rotate the DIAL knob one click
clockwise or press the [S(X)] key momentarily. 5. Press the [SCAN(M-S SCAN)]
key to disable the M-S Scan, and return to the VFO mode.
Setting the dwell timers for the Scanner You can customized the dwell timers
for the Scanner. 1. Press the [F] key momentarily, then press the [ENT(SET)]
key. 2. Rotate the DIAL knob to select the cursor to the “SCAN TM” menu, then
press the
[ENT(SET)] key. 3. Rotate the DIAL knob to select the desired timer (menu) to
be you wish changing.
M-DELAY: Determine the scan resume duration when signal is disappeared.
M-PAUSE: Determine the scanning pause time on activity before resuming.
M-P.DELAY: Determine the scan resume duration when the signal is disappeared
while
the M-PAUSE timer is activated. M-HOLD: Determine the scanning pause time when
signal is received. If the scan-
ner stops until this time, the scanner turns to off. M-H.DELAY: Determine the
scan resume duration when the signal is disappeared while
the M-HOLD timer is activated. 4. Rotate the DIAL knob to change the value for
the timer, then press the [ENT(SET)] key. 5. Rotate the DIAL knob to select
the cursor to the “END” menu, then press the [ENT(SET)] key. 6. Confirm that
the cursor is on the “WRITE” menu, then press the [ENT(SET)] key to
save the new setting and exit to the normal operation.
36
VR-5000 OPERATING MANUAL
Band Scope Operation
The Band Scope allows viewing of operating activity on channels above or below
the current operating channel in the VFO mode.
The display will indicate the relative signal strengths of signals on channels
immediately adjacent to the current operating frequency. A convenient “Channel
marker” can be used to zero in on one of the stations displayed; when you turn
off the Band Scope, the VR-5000 will be set to the frequency set by the
Channel Marker.
Sweep Range
Channel Marker
Sweep Step
To activate the Band Scope
1. Set the radio to the VFO mode by pressing the [V/M(MW)] key, if necessary.
2. Press the [BS(BS SET)] key momentarily to activate the Band Scope. 3. When
the Band Scope is activated, press the [M/S(SUB SET)] key; you cannow move
the Channel Marker. This allows the Channel Marker to be moved anywhere within
the programmed sweep range. When the Channel Marker is set to a frequency that
may be of interest, press the [COPY(REC)] key; the frequency will change to
that set by the Channel Marker. 4. When the Band Scope is activated, you can
change the Sweep steps, which may be adjusted using the front panel keys. To
do this, press the [F] key momentarily, then press the [WIDTH(BS STEP)] key to
select the sweep step from the following selections:
MODE
Steps
LSB/USB/CW 1.0 kHz (fixed)
AM-N/AM WAM FM-N
1.0/5.0/9.0/10.0/20.0/25.0/50.0 kHz 1.0/5.0/9.0/10.0/20.0/25.0/50.0/100.0 kHz 5.0/6.25/10.0/12.5/20.0/25.0/50.0/100 kHz
WFM
10.0/50.0/100/500 kHz
5. The Sweep range is can be changed, as well. To do this, press the [WIDTH(BS STEP)] key to select the sweep step as follows:
MODE
Sweep range
LSB/USB/CW AM-N/AM WAM/FM-N WFM
100/300/500 kHz 0.1/0.2/0.3/0.5/1.0/2.0/2.5/5.0/10.0 MHz 0.5/1.0/2.0/2.5/5.0/10.0 MHz 1.0/2.0/5.0/10.0 MHz
VR-5000 OPERATING MANUAL
37
Smart Search Operation
The Smart Search feature allows you to load frequencies automatically
according to where activity is encountered by your radio. Smart Search will
sweep the band of frequencies within the current “PMS” frequency pair
(described previously), making a note of where activity is encountered and
automatically loading those frequencies into a special Smart Search memory
bank. The sweep will not pause on any of these busy channels, however; the
frequency will automatically be stored without interrupting the scan.
To determine the Memory Bank for the Smart Search feature: 1. Press the [F]
key momentarily, then press the [ENT(SET)] key. 2. Rotate the DIAL knob to set
the cursor to the “PMS” menu option, then press the
[ENT(SET)] key. 3. Confirm that the cursor is on the “S.SCH Bank” menu option,
then press the [ENT(SET)] key. 4. Rotate the DIAL knob to select the Memory
Bank which you wish to use the Memory
Bank for the Smart Search, then press the [ENT(SET)] key. 5. Press the [ ·
(BEEP)] key to select the between “STOP” or “FIFO.” If you select “STOP,”
Smart Search will sweep the selected Memory Bank once, and then stop the scan
(whether or not all the Smart Search memories are filled). If you select
“FIFO,” Smart Search will repeatedly sweep until all Smart Search memories are
full. 6. Rotate the DIAL knob to set the cursor to the “END” menu option, then
press the [ENT(SET)] key. 7. Confirm that the cursor is on the “WRITE” menu
option, then press the [ENT(SET)] key.
To initiate the Smart Search sweep: 1. Recall the PMS memory channel which
memorized band limit for the Smart Search. 2. Press the [F] key momentarily,
then press the [3(S.SCH)] key to initiate the Smart
Search. 3. When Smart Search is engaged, press the [SCAN(M-S SCAN)] key
momentarily to
stop the Smart Search. 4. Press the [V/M(MW)] key momentarily to disable the
Smart Search operation and re-
turn to the normal operation.
To recall the Smart Search Memories: 1. Recall the Memory mode. 2. Using the
[T(W)/S(X)] key or keypad, select the Memory Bank for the Smart Search. 3.
Rotate the DIAL knob to select Smart Search Memory.
38
VR-5000 OPERATING MANUAL
Priority Operation
The priority feature, which is somewhat similar to Dual Watch, allow you to monitor a memory channel while checking a “Priority Memory” channel every five seconds for activity. If the Priority Memory channel becomes active with a signal strong enough to open the Squelch, the radio will halt on that frequency and will hold there in accordance with the setting of the “RESUME” mode described previously.
To setup the Priority Monitoring feature:
1. If you are operating on just one Memory Bank, select the Memory Bank
within which
the desired “Priority Channel” is to be found. 2. Press the [F] key
momentarily, then press the [V/M(MW)] key. 3. Rotate the DIAL knob to set the
cursor to the “Channel” menu, then press the
[ENT(SET)] key. 4. Rotate the DIAL knob to select the channel you wish to
designate as the “Priority”
channel. The channel frequency will appear at the botto of the left side of
the display. 5. Press the [F] key momentarily, then press the [5(PRI)] key. A
“PRIX” icon will appear
to the left of the memory channel number on the LCD. Now press the [ENT(SET)]
key. 6. Rotate the DIAL knob to set the cursor to the “END” menu option, then
press the
[ENT(SET)] key. 7. Confirm that the cursor is on the “WRITE” menu option, then
press the [ENT(SET)] key.
To initiate Priority Channel operation: Press the [F] key momentarily, then
press the [5(PRI)] key to initiate Priority Channel operation. Every five
seconds, the Priority Channel will be checked for activity; if activity is
found on the Priority Channel, the VR-5000 will automatically switch to that
channel. If no activity is encountered on the Priority Channel, you can
operate on other memory channels (and even scan, if desired), and the VR-5000
will continue to poll the Priority Channel, looking for activity.
To disable Priority Channel operation, again press the [F] key momentarily,
then press the [5(PRI)] key .
The polling time for the Priority Channel may be changed, if you like. To do
this: 1. Press the [F] key momentarily, then press the [ENT(SET)] key. 2.
Rotate the DIAL knob to set the cursor to the “MISC” menu option, then press
the
[ENT(SET)] key. 3. Rotate the DIAL knob to set the cursor to the “PRI WATCH”
menu option, then press
the [ENT(SET)] key. 4. Rotate the DIAL knob to select the polling time; the
available selections are “1 sec,”
“2 sec,” “5 sec,” and “10 sec.” When you have made your selection, press the
[ENT(SET)] key. 5. Rotate the DIAL knob to set the cursor to the “END” menu
option, then press the [ENT(SET)] key. 6. Confirm that the cursor is on the
“WRITE” menu option, then press the [ENT(SET)] key.
VR-5000 OPERATING MANUAL
39
World Clock
The VR-5000 provides a World Clock with time references to 66 different areas
of the world, for quick time zone recognition.
1. Press the [F] key momentarily, then press the [4(SPL)] key. 2. Confirm
that the cursor is on the “WORLD TIME” menu, then press the [ENT(SET)] key.
The World Clock and its accompanying World Atlas will appear. 3. Rotate the
DIAL knob to select the desired area. 4. Press the [F] key momentarily, then
press the [9(TIMER)] key. 5. Press the [· (BEEP)] key if you need to advance
the clock one hour to account for
“Summer Time.” Press the [· (BEEP)] key again to restore Standard Time. 6. To
disable the World Clock, press the [CLR(PRI CLR)] key then press the
[ENT(SET)] key.
Display HONOLULU TAHITI ANCHORAG VANCOUVR SAN FRAN LOS ANGL CALGARY DENVER MEX CITY DALLAS CHICAGO MIAMI TORONTO PANAMA LIMA MONTREAL NEW YORK SANTIAGO CARACAS B. AIRES SAO PAUL CANARY I
Area Name Honolulu Tahiti Anchorage Vancouver
San Francisco Los Angels Calgary Denver Mexico Dallas Chicago Miami Tronto
Panama Lima Montreal New York Santiago Caracas
Buenos Aires Sao Paulo
Canary Islands
Registered Area Name
Display DAKAR LONDON MADRID BARCELON PARIS BRUSSELS AMSTERDM ZURICH ROME BERLIN VIENNA STOCKHLM ATHENS HELSINKI CAIRO JERUSALM NAIROBI MOSCOW JEDDAH RIYADH TEHRAN DUBAI
Area Name Dakar London Madrid
Barcelona Paris
Brussels Amsterdam
Zurich Rome Berlin Vienna Stockholm Athens Helsinki Cairo Jerusalem Nairobi
Moscow Jeddah Riyadh Teheran Dubai
Display KABUL KARACHI MALDIVES NEW DELH CALCUTTA KATMANDU DHAKA YANGON BANGKOK JAKARTA SINGAPOR HONGKONG PERTH BEIJING TAIPEI SEOUL TOKYO ADELAIDE SYDNEY NOUMEA WELLNGTN FIJI
Area Name Kabul Karachi
Maldives New Delhi Calcutta kathmandu
Dhaka Yangon Bangkok Jakarta Singapore Hongkong Perth Beijing Taipei Seoul
Tokyo Adelaide Sydney Noumea Wellington
Fiji
40
VR-5000 OPERATING MANUAL
World Clock
You can change the area name to be desired name (i.e. “LOS ANGL” change to
“Cerritos”). To do this:
1. Recall the area which you wish change the area name, as descried
previously. 2. Press the [ENT(SET)] key to enable the programming of the area
name. 3. Program the area name (max 8 characters) using the DIAL knob and
keypad, as de-
scried previously then press the [ENT(SET)] key. In this case “Cerritos.” 4.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT(SET)] key.
VR-5000 OPERATING MANUAL
41
Timer Operation
ON/OFF TIMER
The Program timer can be utilized to set the VR-5000 to user-programmed
frequencies automatically at preset times. This is particularly convenient if
you want to be sure not to miss programs of particular interest.
Programming:
1. Set the Main VFO to the desired receiving frequency (the frequency to
which you want the VR-5000 to switch automatically).
2. Press the [F] key momentarily, then press the [9(TIMER)] key. 3. Rotate
the DIAL knob to set the cursor to the “TM PROG.” Menu option, then press the
[ENT(SET)] key. 4. Press [ENT(SET)] key again to enable the programming of the
Program Timer’s clock
settings. 5. Rotate the DIAL knob to adjust the time you want the radio to
switch to the programmed
frequency, then press the [ENT(SET)] key. 6. Rotate the DIAL knob to adjust
the time you want the radio to revert to the original
frequency, then press the [ENT(SET)] key. 7. If you wish to attach an
alpha/numeric name to the On/Off timer, program the alpha-
numeric “label” using the DIAL knob and keypad, as described previously;
otherwise press the [COPY(REC)] key. 8. Rotate the DIAL knob to set the cursor
to the “WRITE” menu, then press the [ENT(SET)] key. 9. Confirm that the cursor
is on the “WRITE” menu option, then press the [ENT(SET)] key.
Operation: 1. Press the [F] key momentarily, then press the [9(TIMER)] key. 2.
Rotate the DIAL knob to set the cursor to the “TM PROG.” Menu, then press the
[ ·
(BEEP)] key to select “ON,” which enables the On/Off timer. 3. Rotate the DIAL
knob to set the cursor to the “END” Menu option, then press the
[ENT(SET)] key.
To disable the On/Off timer, set the “TM PROG.” Menu option to “OFF” in step 2
by pressing the [· (BEEP)] key .
When the On/OFF Timer is activated, the ” frequency display in the LCD.
” icon will appear above the MAIN
Deletion of Program Timer Settings: 1. Press the [F] key momentarily, then
press the [9(TIMER)] key. 2. Rotate the DIAL knob to set the cursor to the “TM
PROG.” Menu, then press the
[ENT(SET)] key.
3. Rotate the DIAL knob to set the cursor to the program to want to delete.
4. Press the [· (BEEP)] key, then press the [COPY(REC)] key.
42
VR-5000 OPERATING MANUAL
Timer Operation
5. Confirm that the cursor is on the “WRITE” menu option, then press the
[ENT(SET)] key.
Notes: · The program timer requires that both times be on the same day.
Therefore, it is not
possible to program a “Start Time” of 23:30 and an “End Time” of 00:30.
· It is possible to set up to 48 program times. However, the times for the
programs must not overlap (the radio cannot switch away during a timer
operation to a second program).
SLEEP TIMER
The Sleep Timer can be automatically turn off the radio. This is convenient if
you want to doze off listening to the radio.
1. Press the [F] key momentarily then press the [9(TIMER)] key. 2. Rotate the
DIAL knob to select the cursor to the “SLEEP” Menu, then press the
[ENT(SET)] key to enable the programming of the Sleep Timer. 3. Rotate the
DIAL knob to select the desired sleep time among “30 min,” “60 min,” “90
min,” “120 min,” and “OFF,” then press the [ENT(SET)] key. 4. Rotate the DIAL
knob to select the cursor to the “END” menu, then press the [ENT(SET)] key. 5.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT(SET)] key.
When activate the Sleep Timer, appear the “SLEEP” icon above the MAIN
frequency display in the LCD.
ALARM TIMER
The Alarm Timer can be automatically turn on the radio. This is convenient if
you wake up to your favorite station (or beep sound) every morning.
1. Press the [F] key momentarily then press the [9(TIMER)] key. 2. Rotate the
DIAL knob to select the cursor to the “ALARM” Menu, then press the
[ENT(SET)] key to enable the programming of the Alarm Timer. 3. Press the key
to select the Alarm sound between the “RADIO” or “BEEP,” then press the
[ENT(SET)] key. 4. Enter the time you want the radio turn on using the keypad,
as descried previously, then
press the [ENT(SET)] key. 5. Rotate the DIAL knob to select the cursor to the
“END” menu, then press the [ENT(SET)] key. 6. Confirm that the cursor is on
the “WRITE” menu, then press the [ENT(SET)] key.
When activate the Alarm Timer, appear the ” play in the LCD.
” icon above the MAIN frequency dis-
VR-5000 OPERATING MANUAL
43
DSP Operation
Digital Signal Processing is a highly-effective fitering technology which can
dramatically improve reception. The optional DSP Unit (DSP-1) brings to the
VR-5000 the following four features:
U DSP NOTCH Filter U DSP Bandpass Filter U DSP CW Peaking Filter U DSP Noise
Reducer U CW-PITCH
DSP NOTCH FILTER
Unwanted beat notes within the receiver’s IF filter passband can be
effectively removed by utilization of the DSP NOTCH Filter.
To activate the DSP NOTCH Filter: 1. Press the [F] key momentarily, then press
the [DSP] key. 2. Rotate the DIAL knob to set the cursor to the “NOTCH” menu
option, then press the [·
(BEEP)] key to change its setting to “ON.” 3. Rotate the DIAL knob to set the
cursor to the “END” menu option, then press the
[ENT(SET)] key. 4. Confirm that the cursor is on the “UPDATE” menu option,
then press the [ENT(SET)] key to exit the setup process. 5. Press the [DSP]
key to activate the DSP system.
To disable the DSP NOTCH Filter, set the “NOTCH” menu item to “OFF” in step 2.
DSP BANDPASS FILTER
In the SSB, AM, and FM modes, the DSP Bandpass Filter may be used to enhance
the receiver’s selectivity. Interference from adjacent-frequency stations,
high-pitched noise, and low-frequency “rumble” components are among the types
of problems which may be minimized using the DSP Bandpass Filter.
LOW-CUT
N orm a l
HI GH-CUT
Peak
44
VR-5000 OPERATING MANUAL
DSP Operation
The bandwidth of the DSP Bandpass Filter is critical to its successful
utilization, and it may be modified per the procedure below.
1. Press the [F] key momentarily, then press the [DSP] key. 2. Rotate the
DIAL knob to set the cursor to the “LOW-CUT” menu option, then press the
[ · (BEEP)] key; this enables adjustment of the cutoff frequencies of the DSP
Bandpass Filter. 3. Press the [ENT(SET)] key, then rotate the DIAL knob to
adjust the low-frequency cutoff of the DSP Bandpass Filter as desired (100 ~
1600 Hz). A setting of 300 or 400 Hz is a good starting point for most voice
work. Press the [ENT(SET)] key when you have made your selection. 4. Confirm
that the cursor is set to the “HIGH-CUT” menu option, then press the
[ENT(SET)] key. 5. Rotate the DIAL knob to adjust the low frequency-cutoff as
desired (1500 ~ 3000 Hz). A setting of 2100 ~ 2700 Hz is a good starting
point. Press the [ENT(SET)] key when you have made your selection. 6. Rotate
the DIAL knob to set the cursor to the “END” menu option, then press the
[ENT(SET)] key. 7. Confirm that the cursor is on the “UPDATE” menu option,
then press the [ENT(SET)] key to exit the setup process. 8. Press the [DSP]
key to activate the DSP system.
To disable the DSP Bandpass Filter, set the “LOW-CUT” menu item to “OFF” in
step 2.
DSP CW PEAKING FILTER
In the CW mode, you can activate a narrow-bandwidth peaking filter, which may
be ideal for use under very crowded conditions.
To activate the DSP CW Peaking Filter as follow:
1. Be sure that the radio is set to the CW mode; the CW Peaking Filter will
not function in
the USB or LSB mode. 2. Press the [F] key momentarily, then press the [DSP]
key. 3. Confirm that the cursor is on the “CW-BW” menu option, then press the
[· (BEEP)] key. 4. Press the [ENT(SET)] key, then rotate the DIAL knob to
select the desired bandwidth.
The available values are 25 Hz, 100 Hz, 200 Hz, and 400 Hz. 5. Press the
[ENT(SET)] key, then rotate the DIAL knob to select the “END” menu op-
tion, then press the [ENT(SET)] key. 6. Confirm that the cursor is on the
“UPDATE” menu, then press the [ENT(SET)] key to
exit the setup procedure. 7. Press the [DSP] key to activate the DSP system.
To disable the DSP CW Peaking Filter, set the “CW-BW” menu option to “OFF” in step 4.
VR-5000 OPERATING MANUAL
45
DSP Operation
DSP NOISE REDUCTION
The DSP Noise Reduction feature can be effective against a wide variety of
noise types; it is not limited to the “impulse” type (such as ignition noise).
To activate the DSP Noise Reduction system: 1. It is helpful to set up the
receiver on a frequency with a station present, so you can hear
the effects of any changes you make. Press the [DSP] key to engage the DSP. 2.
Press the [F] key momentarily, then press the [DSP] key. 3. Rotate the DIAL
knob to set the cursor to the “NR” menu option, then press the [ ·
(BEEP)] key. 4. Press the [ENT(SET)] key, then rotate the DIAL knob to find
the point where best
signal-to-noise ratio is obtained under the current noise conditions. 5. Press
the [ENT(SET)] key, then rotate the DIAL knob to set the cursor to the “END”
menu option, then press the [ENT(SET)] key. 6. Confirm that the cursor is on
the “UPDATE” menu option, then press the [ENT(SET)] key to exit the setup
process.
To disable the DSP Noise Reduction feature, set the “NR” menu option to “OFF”
in step 3.
CW-PITCH
In the CW mode, you can change the CW Pitch as desired. This feature adjusts
the center frequency of the DSP CW Peaking Filter, to match the CW tone you
prefer to listen to.
To change the CW Pitch: 1. Press the [F] key momentarily, then press the [DSP]
key. 2. Rotate the DIAL knob to set the cursor to the “CW-PITCH” menu option,
then press the
[· (BEEP)] key. 3. Press the [ENT(SET)] key, then rotate the DIAL knob to
choose the desired CW Pitch.
The available values are 400 Hz ~ 1100 Hz (in 50 Hz steps). 4. Press the
[ENT(SET)] key, then rotate the DIAL knob to set the cursor to the “END”
menu option, then press the [ENT(SET)] key. 5. Confirm that the cursor is on
the “UPDATE” menu option, then press the [ENT(SET)] key to exit the setup
process.
Note: If you set the “CW-PITCH” menu item to “OFF” in step 2, it will
automatically disable the CW Bandpass Filter. This is a “short-cut” to speed
your progress through the Menu system.
46
VR-5000 OPERATING MANUAL
Miscellaneous Features
ATT (RF ATTENUATOR)
For situations where extremely high signal levels are present, the receiver’s
input ATTenuator may be activated, to reduce the sensitivity and total gain of
the receiver system.
1. To activate the Attenuator, press the [F] key momentarily, then press the
[1(ATT)] key. The “ATT” icon will appear on the display. You should also hear
a decrease in the incoming signal strength (and background noise) with the
Attenuator engaged.
2. To switch the Attenuator off, press the [F] key momentarily, then press
the [1(ATT)] key; the “ATT” icon will disappear from the display.
NB (NOISE BLANKER)
For reduction of impulse noise, such as that produced by automotive ignition
systems, the noise blanker feature may prove helpful. The Noise Blanker is
available in the SSB, CW, AM and FM-N modes.
1. To activate the Noise Blanker, press the [F] key momentarily, then press
the [0(NB)] key. The “NB” icon will appear on the display. You should observe
a reduction in the ignition noise.
2. To switch the Noise Blanker off, press the [F] key momentarily, then press
the [0(NB)] key; the “NB” icon will disappear from the display.
RF TUNE
This feature allows you to shift the RF passband to maximize the receiver’s
sensitivity and reduce interference from out-of-band stations.
1. Press the [F] key momentarily, then press the [8(RF TUNE)] key to activate
the RF TUNE feature.
2. Rotate the DIAL knob to the position where the desired signal strength is
maximized, or where the interference is eliminated, the press the [ENT(SET)]
key
3. To disable the RF TUNE feature, again press the [F] key momentarily, then
press the [8(RF TUNE)] key.
KEYPAD BEEPER
If the keypad’s beeper creates an inconvenience (particularly when operating
late at night!), it may easily be disabled.
1. To disable the keypad beeper, press the [F] key momentarily, then press
the [· (BEEP)] key.
2. If you wish to re-enable the keypad beeper, press the [F] key momentarily,
then press the [· (BEEP)] key.
VR-5000 OPERATING MANUAL
47
Miscellaneous Features
LOCKING FRONT PANEL CONTROLS
In order to prevent accidental frequency change, the VR-5000’s front panel
Controls may be locked out.
1. To lock out the Front Panel Controls, press the [F] key momentarily, then
press the [2(LOCK)] key. The “KEY” icon will appear on the display.
2. To cancel locking, press the [F] key momentarily, then press the [2(LOCK)]
key; the “KEY” icon will disappear from the display.
You can change the lockout combinations. This feature allows you to customize
the controls that will be locked out.
1. Press the [F] key momentarily, then press the [ENT(SET)] key. 2. Rotate
the DIAL knob to set the cursor to the “MISC” menu option, then press the
[ENT(SET)] key. 3. Rotate the DIAL knob to set the cursor to the “KEY LOCK”
menu option, then press the
[ENT(SET)] key. 4. Press the [· (BEEP)] key to select the desired lockout
combination: “Key&Dial,” “Key,”
or “Dial.” 5. To attach a “Password” to the Locking feature, enter a four-
digit password (0000 ~
9999) via the keypad, and then press the [ENT(SET)] key, otherwise just press
the [ENT(SET)] key. 6. Confirm that the cursor is on the “WRITE” menu option,
then press the [ENT(SET)] key to save the new setting and exit to normal
operation.
To cancel the “Password:” 1. Press the [F] key momentarily, then press the
[ENT(SET)] key. 2. Rotate the DIAL knob to set the cursor to the “MISC” menu
option, then press the
[ENT(SET)] key. 3. Rotate the DIAL knob to set the cursor to the “KEY LOCK”
menu option, then press the
[ENT(SET)] key. 4. Enter the four digit password which you programmed via the
keypad, then press the
[ENT(SET)] key. 5. Press the following key sequence:
[ENT(SET)] ¯ [F] ¯ [CLR(PRI CLR)] ¯ [ENT(SET)] 6. Confirm that the cursor is
on the “WRITE” menu option, then press the [ENT(SET)] key to cancel the
“Password” and exit to normal operation.
48
VR-5000 OPERATING MANUAL
Miscellaneous Features
DISPLAY CONTRAST
The display contrast may be adjusted, as well.
1. Press the [F] key momentarily, then press the [ENT(SET)] key. 2. Rotate
the DIAL knob to set the cursor to the “MISC” menu option, then press the
[ENT(SET)] key. 3. Rotate the DIAL knob to select the cursor to the “LCD CONT”
menu, then press the
[ENT(SET)] key. 4. Rotate the DIAL knob to adjust the contrast level “0 (low
contrast) ~ 15 (high con-
trast)” to a comfortable setting. 5. Rotate the DIAL knob to set the cursor to
the “END” menu option, then press the
[ENT(SET)] key. 6. Confirm that the cursor is on the “WRITE” menu option,
press the [ENT] key to save
the new setting and exit to normal operation.
DISPLAY DIMMER
The LCD’s illumination level may be adjusted by the front panel keys.
1. Press the [V(DIM)] key momentarily to enable adjustment of the LCD
illumination level.
2. Rotate the DIAL knob to adjust the illumination level “0 (dim) ~ 7
(bright).” As you make the adjustment, you will be able to see the effects of
your changes.
3. When you have completed the adjustment, press the [ENT(SET)] key to save
the new setting and exit to normal operation.
SELECTING THE [F] KEY “HANG·ETIME
By default, when you press the [F] key momentarily, the “[F] icon (indicating
“Alternate” function mode) will remain active for 5 seconds. The default
5-second “Alternate” command time can be changed to a shorter or longer
duration, if desired.
1. Press the [F] key momentarily, then press the [ENT(SET)] key. 2. Rotate
the DIAL knob to set the cursor to the “MISC” menu option, then press the
[ENT(SET)] key. 3. Rotate the DIAL knob to set the cursor to the “FUNC TM”
menu option, then press the
[ENT(SET)] key. 4. Rotate the DIAL knob to select the desired duration time
(1/2/3/5/10 seconds, and
“Toggle”). 5. Rotate the DIAL knob to set the cursor to the “END” menu option,
then press the
[ENT(SET)] key. 6. Confirm that the cursor is on the “WRITE” menu option, then
press the [ENT(SET)] key to save the new setting and exit to normal operation.
VR-5000 OPERATING MANUAL
49
Miscellaneous Features
VOICE SYNTHESIZER OPERATION
The optional Voice Synthesizer Unit (FVS-1) enables an audible announcement of
the current (Main Band) operating frequency.
1. Press the [F] key momentarily, then press the [V(DIM)] key to activate the
Voice Synthesizer Unit. The [V(DIM)] key is the switch directly below the
bottom right-hand corner of the display.
2. When you press the [V(DIM)] key again (or change the Main Band frequency),
the Voice Synthesizer will announce the current (Main Band) operating
frequency.
3. To disable the Voice Synthesizer frequency announcements, press the [F]
key momentarily, then press the [V(DIM)] key.
4. The audio monitoring level is controlled by the “SUB VOL” control, so
advance the setting of this knob if you do not hear the frequency
announcements when the [V(DIM)] key is pressed.
DIGITAL VOICE RECORDER
The optional Digital Voice Recorder Unit (DVS-4) enables the recording of
received signals for playback later in the loudspeaker or headphones. Under
difficult conditions, this may allow you to identify weak stations by
repeatedly listening to the audio stream. You may also wish to record
“snippets” for later transfer to a tape recorder as a record of stations
heard.
Recording
1. Press the [F] key momentarily, then press the [MODE(ADRS)] key. 2. Select
the recording memory channel (“DVR ch1” or “DVR ch2”) by pressing the
[MODE(ADRS)] key. 3. Press the [F] key momentarily, then press the [COPY(REC)]
key to start the recorder. 4. When you hear something you want to play back,
press the [F] key momentarily, then
press the [COPY(REC)] key again. This will stop the recording process,
preserving the last 8 seconds of incoming audio.
Notes: · It is possible to record for a maximum of 16 seconds in the primary
recording channel,
“DVR ch1.” If the recording time on this channel is 8 seconds or less, it is
then possible to record for a maximum of 8 seconds in the secondary recording
channel, “DVR ch2.” · If you record for more than 8 seconds in channel “DVR
ch1,” the contents of recording channel “DVR ch2” will be erased. · If you
manually choose record in channel “DVR ch2,” the last 8 seconds of the
contents of channel “DVR ch1” will disappear.
Monitor
1. Press the [F] key momentarily, then press the [MODE(ADRS)] key.
50
VR-5000 OPERATING MANUAL
Miscellaneous Features
2. Select the monitoring memory channel (“DVR ch1” or “DVR ch2”) by pressing
the [MODE(ADRS)] key.
3. Press the [F] key momentarily, then press the [STEP(PLAY)] key to start
the monitor.
Notes: · If you select the “DVR ch1” channel for playback, it will play back
audio for 16 seconds
(irrespective of the actual recording time). · If you select the “DVR ch2”
channel for playback, it will play back audio for 8 seconds
(irrespective of the actual recording time).
FIELD STRENGTH METER
The VR-5000 can provide display of the relative receiving signal strength on
the LCD, compared to some user-defined “baseline” field strength.
1. Press the [F] key momentarily, then press the [4(SPL)] key. 2. Rotate the
DIAL knob to set the cursor to the “BASE FIELD STRENGTH” menu option,
then press the [ENT(SET)] key. 3. You will now observe the display of the cur-
rent signal strength (“CURRENT” row) and its peak level (“REFERENCE” row). The
first time this is done, these levels will be the same (although the “CURRENT”
level will appear to have a very slightly lower value, due to the “damping” in
the metering). 4. If you are resetting the reference level, press the [0(NB)]
key to equalize the peak level to the current signal strength. 5. To cancel
the Field Strength Meter displays the [ENT(SET)] key momentarily; this will
save the peak level and let you exit to the menu mode. 6. Confirm that the
cursor is on the “CANCEL” menu selection, then press the [ENT(SET)] key to
exit to normal operation.
If you want to display the current signal level (for example, on a different channel), compared to the reference level, use the following process:
1. Press the [F] key momentarily, then press the [4(SPL)] key. 2. Rotate the
DIAL knob to set the cursor to the “CURRENT FIELD STR.” menu option,
then press the [ENT(SET)] key. 3. The current signal strength (“CURRENT” row)
and the memorized peak level (“REF-
ERENCE” row) will be displayed. 4. To cancel the Field Strength Meter display,
press the [ENT(SET)] key momentarily, to
save the peak level and exit to menu mode. 5. Confirm that the cursor is on
the “CANCEL” menu, then press the [ENT(SET)] key to
exit to the normal operation.
VR-5000 OPERATING MANUAL
51
Miscellaneous Features
AUDIO WAVE METER
The VR-5000 can be set up to display the relative received audio wave-form on
the LCD.
1. Press the [F] key momentarily, then press the [4(SPL)] key. 2. Rotate the
DIAL knob to set the cursor to the “AUDIO WAVE” menu option, then press
the [ENT(SET)] key. 3. Display the current signal audio wave-form. 4. Press
the [T(W)/S(X)] keys to select the sam-
pling rate between 50 ms ~ 200 ms (in 10 ms increments). 5. To cancel the
Audio Wave Meter display, press the [ENT(SET)] key momentarily. 6. Confirm
that the cursor is on the “CANCEL” menu option, then press the [ENT(SET)] key
to exit to normal operation.
RADIO CONTROL (R/C) CHANNEL MONITORING
The VR-5000 can be configured for monitoring activity on all typical Radio
Control channels simultaneously. A graphical representation of channel
occupancy will be created, called the “PMR Board.” The VR-5000 will monitor
the activity on these channels simultaneously via a rapid search function.
An “indicator” or indicators will appear on the board, as described below,
letting you know that activity was noted on that channel.
Before commencing operation in this mode, be sure that the SQL control is set
up so as to quiet the background noise.
1. Press the [F] key momentarily, then press the [4(SPL)] key. 2. Rotate the
DIAL knob to set the cursor to the R/C channel set appropriate for your local
area, then press the [ENT(SET)] key. 3. Rotate the DIAL knob to set the cursor
to the R/C band (for your geographical area)
which you wish to monitor, then press the [ENT(SET)] key. 4. The activity on
the R/C Board will now be displayed as a matrix of channel squares.
The “White” squares indicate vacant channels, and Black squares indicate
occupied channels. 5. Press the [CLR(PRI CLR)] key, followed by the [ENT(SET)]
key, to return to normal operation.
52
VR-5000 OPERATING MANUAL
Cloning
The VR-5000 includes a convenient “Clone” feature, which allows the memory and
configuration data from one receiver to be transferred to another VR-5000.
Here is the procedure for Cloning one radio’s data to another:
1. Set both radio’s baud rate to the same rate, such as “”57,600 bps,” per
the following steps: (1) Press the [F] key momentarily, then press the
[ENT(SET)] key. (2) Rotate the DIAL knob to set the cursor to the “CAT RATE”
menu option, then press the [ENT(SET)] key. (3) Rotate the DIAL knob to set
the cursor to the desired rate (4800/9600/57600 bps), then press the
[ENT(SET)] key. (4) Confirm that the cursor is on the “END” menu option, then
press the [ENT(SET)] key. (5) Confirm that the cursor is on the “WRITE” menu
option, then press the [ENT(SET)] key.
2. Turn both radios off. 3. Connect the a (D-SUB 9-pin) RS-232C cross cable
(not supplied) between the CAT
jacks on the rear panels of the two radios. 4. Turn the Destination radio on
(“CLONE SLAVE” will appear on the LCD), then turn the
Source radio on (“CLONE MASTER” will appear on the LCD). 5. Press the
[COPY(REC)] key on the Source radio; “WRITE” will appear on the Source
radio, and the data transfer will commence. 6. If the data transfer is
successful, “COMPLETE” will appear on both radios. Turn both
radios off and disconnect the RS-232C cross cable. You can then turn the
radios back on, and begin normal operation.
DC 13.5V
MUTE
ANT B
B
A
ANT
ANT A
EXT SP REC
+8V
IF OUT
CAT
DC 13.5V
MUTE
ANT B
B
A
ANT
ANT A
EXT SP REC
+8V
IF OUT
CAT
RS-232C Cross Cable
VR-5000 OPERATING MANUAL
53
CAT Operation
The CAT (Computer Aided Transceiver) System in the VR-5000 provides control of
MAIN VFO frequency and Receiving mode using an external personal computer.
This allows multiple control operations to be fully automated as single mouse
clicks or keystroke operations on the computer keyboard.
The VR-5000 has a built-in level converter, allowing direct connection from
the rearpanel CAT jack to the serial port of your computer without the need of
any external boxes. You will need a serial cable for connection to the RS-232C
(serial or COM port) connector on your computer. Purchase a standard serial
cable (not the so-called “null modem” type), ensuring it has the correct
gender and number of pins (some serial COM port connectors use a 9-pin rather
than 25-pin configuration). If your computer uses a custom connector, you may
have to construct the cable. In this case, refer to the technical
documentation supplied with your computer for correct data connection.
VERTEX STANDARD does not produce CAT System operating software due to the wide
variety of personal computers and operating systems in use today. However, the
information provided in this chapter explains the serial data structure and
opcodes used by the CAT system. This information, along with the short
programming examples, is intended to help you start writing programs on your
own. As you become more familiar with CAT operation, you can customize
programs later on for your operating needs and discover the true operating
potential of this system.
VR-5000
DC 13.5V
MUTE
ANT B
B
A
ANT
ANT A
EXT SP REC
+8V
IF OUT
CAT
Personal Computer
RS-232C Cross Cable
54
VR-5000 OPERATING MANUAL
CAT Operation
CAT Data Protocol
Serial data is passed via the CAT jack on the rear panel of the radio at 4800,
9600, or 57600 bits/sec. All commands sent from the computer to the receiver
consist of five-byte blocks, with up to 200 ms between each byte. The last
byte sent in each block is the instruction opcode, while the first four bytes
of each block are arguments: either parameters for that instruction, or dummy
values (required to pad the block out to five bytes):
Each byte sent consists of one start bit, 8 data bits, no parity bit and two stop bits: CAT Data Byte Format
Start Bit 0 1 2 3 4 5 6 7 Stop Bit Stop Bit CAT 5-Byte Command Structure
Parameter 1 (LCD) Parameter 2 Parameter 3 Parameter 4 Command Data
There are three instruction opcodes for the VR-5000, listed in the table
below. Most of these duplicate menu programming settings or options, or else
emulate front panel button functions. Notice that several instructions require
no specific parameters. However, every Command Block sent to the radio must
always consist of five bytes.
The CAT control program you are writing must construct the 5-byte block, by
selecting the appropriate instruction opcode, organizing the parameters, if
any, and providing unused (dummy) argument bytes for padding the block to its
required 5-byte length (the dummy bytes can contain any value). The resulting
five bytes are then sent, opcode last, from the computer to the VR-5000 CPU
via the serial port and CAT jack on the radio rear panel.
Opcode Command Data
Command Tittel
Parameters
Opcode
Comments
CAT ON/OFF Set Frequency
Receiving Mode
Receiver Status
ÚÚÚÚ F1 F2 F3 F4
M1 M2 Ú Ú
ÚÚÚÚ
P1 P1= 00: ON, P1 = 80: OFF P1 P1= 01: MAIN VFO
P1= 31: SUB VFO P1 P1= 07: MAIN VFO
P1= 37: SUB VFO E7 S-Meter, Squelch, etc.
Note 1: Note 2:
F1 ~ F4 = Frequency Digits (HEX), Example: 439.70 MHz = 02, 9E, ED, D0
F1, F2, F3, F4 Receiving Mode/Channel Step Parameter Codes
M1 00 LSB 44 WAM 01 USB 48 WFM 02 CW 84 AM-N 04 AM 88 FM-N
M2 21 20 Hz 43 5 kHz 05 100 kHz 34 25 kHz 02 100 Hz 53 6.25 kHz 45 500 kHz 44 50 kHz 42 500 Hz 63 9 kHz 14 12.5 kHz 03 1 kHz 04 10 kHz 24 20 kHz
Note 3: Receiver Status
76543210
S-Meter Data Squelch Data
0 = Squelch OFF 1 = Squelch ON
Note 1
Note 2 Note 3
VR-5000 OPERATING MANUAL
55
Reset
MICROPROCESSOR RESETTING
1. Turn the Radio OFF. 2. Press and hold the [CLR(PRI CLR)] key while turing
the Radio ON. 3. Press the [ENT(SET)] key to reset the all setting to their
factory defaults (press the
[CLR(PRI CLR)] key to cancel the Reset procedure).
56
VR-5000 OPERATING MANUAL
Installation of the Optional Accessories
DIGITAL SIGNAL PROCESSING UNIT (DSP-1)
1. Remove the four screws affixing the bottom cover, then remove the bottom
cover (see Figure 1).
2. Locate the empty 11-pin jack, and connect the DSP-1 here (see Figure 2).
3. Mount the DSP-1 to the main chassis using the supplied four screws. 4.
Replace the bottom cover and its four screws.
DIGITAL VOICE MEMORY UNIT (DVS-4)
1. Remove the four screws affixing the bottom cover, then remove the bottom
cover (see Figure 1).
2. Locate the empty 8-pin jack, and connect the DVS-4 here (see Figure 2). 3.
Replace the bottom cover and its four screws.
VOICE SYNTHESIZER UNIT (FVS-1A)
1. Remove the four screws affixing the bottom cover, then remove the bottom
cover (see Figure 1).
2. Locate the empty 10-pin jack, and connect the FVS-1A here (see Figure 2).
3. Set JApanese/ENglish switch on the FVS-1A to the EN. 4. Replace the bottom
cover and its four screw.
°
°
Figure 1
° °
DVS-4 Mounting Position FVS-1A Mounting Position
DSP-1 Mounting Position
Figure 2
VR-5000 OPERATING MANUAL
57
“AUTO” Mode Preset Operating Parameters
Frequency Range (MHz)
MODE
STEP (kHz)
0.10000 ~ 0.52000 AM 1 0.52000 ~ 1.71000 AM 10 1.71000 ~ 3.50000 AM 5 3.50000 ~ 4.00000 LSB 0.1 4.00000 ~ 7.00000 AM 5 7.00000 ~ 7.30000 LSB 0.1 7.30000 ~ 10.10000 AM 5 10.10000 ~ 10.15000 CW 0.1 10.15000 ~ 14.00000 AM 5 14.00000 ~ 14.35000 USB 0.1 14.35000 ~ 18.00000 AM 5 18.00000 ~ 18.20000 USB 0.1 18.20000 ~ 21.00000 AM 5 21.00000 ~ 21.45000 USB 0.1 21.45000 ~ 24.80000 AM 5 24.80000 ~ 25.00000 USB 0.1 25.00000 ~ 28.00000 AM 5 28.00000 ~ 29.70000 USB 0.1 29.70000 ~ 50.00000 FM-N 5 50.00000 ~ 50.10000 CW 0.1 50.10000 ~ 50.50000 USB 0.1 50.50000 ~ 54.00000 FM-N 5 54.00000 ~ 108.00000 WFM 50 108.00000 ~ 142.00000 AM 25
Frequency Range (MHz)
MODE
STEP (kHz)
142.00000 ~ 144.00000 FM-N 12.5 144.00000 ~ 144.10000 CW 0.1 144.10000 ~ 144.30000 USB 0.1 144.30000 ~ 148.00000 FM-N 5 148.00000 ~ 156.00000 FN-N 12.5 156.00000 ~ 157.45000 FM-N 25 157.45000 ~ 160.60000 FM-N 12.5 160.60000 ~ 160.97500 FM-N 25 160.97500 ~ 161.50000 FM-N 12.5 161.50000 ~ 162.90000 FM-N 25 162.90000 ~ 174.00000 FM-N 12.5 174.00000 ~ 216.00000 WFM 50 216.00000 ~ 225.00000 FM-N 5 225.00000 ~ 262.00000 AM 100 262.00000 ~ 270.00000 FM-N 12.5 270.00000 ~ 271.00000 AM 100 271.00000 ~ 275.00000 FM-N 12.5 275.00000 ~ 336.00000 AM 100 336.00000 ~ 420.00000 FM-N 12.5 420.00000 ~ 450.00000 FM-N 25 450.00000 ~ 470.00000 FM-N 12.5 470.00000 ~ 770.00000 WFM 50 770.00000 ~ 1300.00000 FM-N 25 1300.00000 ~ 2599.99998 FM-N 12.5
58
VR-5000 OPERATING MANUAL
Specifications
Frequency Range: 0.1 ~ 2599.99998 MHz (Cellular Blocked)
Receiving Mode:
CW/LSB/USB/AM/AM-N/WAM/FM-N/WFM
Antenna Impedance: 50 unbalanced, 450 unbalanced
Channel Step:
Main Band
LSB/USB/CW : 20 Hz/100 Hz/500 Hz/1 kHz/5 kHz
AM-N/AM/WAM : 1/5/9/10/20/25/50/100/500 kHz
FM-N :
5/6.25/10/12.5/20/25/50/100/500 kHz
WFM :
10/50/100/500 kHz
Sub Band
AM :
1/5/9/10/20/25/50/100/500 kHz
FM-N :
5/6.25/10/12.5/20/25/50/100/500 kHz
Memory Channel: Regular Memories: 2000 Channels
PS “Preset” Memories: 5 Channel
Operating Temp.: 10 °C ~ + 50 °C
Sensitivity:
0.2 ~ 0.49998 MHz
SSB/CW
4.8 V (10 dB S/N)
AM
10.8 V (10 dB S/N)
0.5 ~ 1.79998 MHz
SSB/CW
1.0 V (10 dB S/N)
AM
4.0 V (10 dB S/N)
1.8 ~ 3.99998 MHz
SSB/CW
0.6 V (10 dB S/N)
AM
2.5 V (10 dB S/N)
4.0 ~ 29.99998 MHz
SSB/CW
0.3 V (10 dB S/N)
AM
1.1 V (10 dB S/N)
28.0 ~ 29.99998 MHz
FM-N
0.35 V (12 dB SINAD)
30.0 ~ 1999.99998 MHz
SSB/CW
0.3 V (10 dB S/N)
AM
1.2 V (10 dB S/N)
FM-N
0.45 V (12 dB SINAD)
WFM
1.5 V (12 dB SINAD)
2000.0 ~ 2599.99998 MHz
SSB/CW
0.5 V (10 dB S/N)
AM
1.8 V (10 dB S/N)
FM-N
0.8 V (12 dB SINAD)
Conducted Sprious Emission:
Less than 54 dBm
Supply Voltage:
DC 13.5V ±15 %
Current Consumption: 0.7 A (@ audio output 1W)
Audio Output:
At least 1 W @ 8
Audio Output Impedance:8
Case Size:
180 x 70 x 203 mm (W x H x D) w/o knob
Weight:
Approx. 1.9 kg
Specifications are subject to change without notice.
VR-5000 OPERATING MANUAL
59
Note
60
VR-5000 OPERATING MANUAL
“This scanner receiver is not a digital scanner and it is incapable of being converted or modified to a digital scanner receiver by the user.”
This equipment has been tested and found to comply with the limits for a Class
A Digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the User will be required to correct the
interference at his own expense.
1. Changes or modifications to this device not expressly approved by VERTEX
STANDARD could void the user’s authorization to operate this device.
2. This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions; (1) this device may not cause harmful
interference, and (2) this device must accept any interference including
interference that may cause undesired operation.
3. The scanning receiver in this equipment is incapable of tuning, or readily
being altered, by the User to operate within the frequency bands allocated to
the Domestic public Cellular Telecommunications Service in Part 22.
This device complies with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause interference; and (2) this device must accept any interference, including interference that may cause undesirable operation of this device.
41
Copyright 2009 VERTEX STANDARD CO., LTD. All rights reserved.
Printed in Japan
0901K-JY
No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD.
E13611002
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>