REN WATER HO 5.1 UV Water Purification System User Manual

June 16, 2024
REN WATER

HO 5.1
UV WATER PURIFICATION SYSTEM

  • 5 to 40 GPM
  • Colour screen controller
  • Lightlock™ technology for protected lamp replacement sales

REN WATER HO 5 1 UV Water Purification System-

Product Features

  • Free floating (no cable twist), keyed-in-place, 254nm Teflon® based UV sensor measures continuously, displaying UV intensity as a % – std. Optional on all LCD colour screen models
  • Colour screen controller with Lightlock™ for protected lamp replacement, includes QR codes, full diagnostics & warnings
  •  Expandability port for future upgrades and options
  • Axial flow, 316L stainless steel polished reactors, designed & manufactured to ASME pressure vessel standards
  • Simple lamp changes
  •  Reliable, industry proven, proprietary low pressure, high-output, coated UV lamps with ceramic bases for durability and long life
  • Constant current electronic controller in a splash proof case
  • Full customization available as an option — language, home screen, phone number, QR codes, etc.

If you are looking for UV water treatment for your home, REN WATER has the solution in the HO series of residential UV systems.
REN WATER-HO provides UV water treatment for your home with the inclusion of a true 254nm Teflon® based UV sensor that continuously monitors the performance of the UV system, displaying the output via a colour screen (optional on 5.1 systems). In addition to UV output, diagnostics, system status, warnings and QR codes can also be displayed. With the integral expandability port, the addition of a 4-20mA output or a solenoid valve is a simple plug-and-play option.

Sample Screens

REN WATER HO 5 1 UV Water Purification System- Sample
Screens

Point-of-Use (POU)
RW-ULX41/46, for flow rates of 19 Ipm (5 gpm)
Point-of-Entry (POE)
RW-ULX43/47, for flow rates of 38 [pm (10 gpm)
RW-ULX42/48, for flow rates of 57 Ipm (15 gpm)
RW-ULX44/49, for flow rates of 95 Ipm (25 gpm)
RW-ULX45/50, for flow rates of 151 Ipm (40 gpm)

Assembly

Unpack the system and ensure all the components are included with the system. Your system is shipped with the following components:
BLACKCOMSB (Standard output lamp systems)

REN WATER HO 5 1 UV Water Purification System-
Assembly

Installation

Stepl: The reactor can be installed either horizontally or vertically using the clamps provided. Vertical installation is the preferred method with the inlet at the bottom (lamp connection at the top) as it allows any air that may be in the lines to be easily purged from the system.
Step2: The use of a by-pass assembly is recommended as it will allow you to isolate the UV reactor. This will allow for easier access in case maintenance is required (See Figure 4).
Step3 : Fasten chamber clamps to wall with screws provided. The screws must anchor securely into solid wood, concrete, or steel structure for adequate strength. Do not attempt to secure screws into drywall (Figure 3a). Install Chamber into clamps (Figure 3b).
Step4: For water supplies where the maximum flow rate is unknown, a flow restrictor is recommended so that the rated flow of your particular BLACKCOMB system is not exceeded. The flow restrictor should be installed on the inlet port of the reactor.
Step5: Itis recommended to have a licensed plumber connect the UV reactor to the water supply and may be a requirement depending on where you are located.

REN WATER HO 5 1 UV Water Purification System-
Assembly2

Step 11: Always hold UV lamps by their ceramic ends, not by the lamp quartz. Remove the lamp from its packaging. Again, the use of cotton gloves is recommended. Remove the lamp key from the lamp’s connector and set it aside for the next step. Be careful to not touch the key’s exposed contacts. Insert the UV lamp into the reactor, being careful not to drop it.

REN WATER HO 5 1 UV Water Purification System- lamp

Step 12: Install the lamp key into the controller (BLACKCOMBS, BLACKCOMBS systems only). The key always comes packaged with the lamp and sits on the connector. With the key removed from the lamp, orient it so the label is upright and facing you. The key will plug into the lamp key port on the right side of the controller (Figure 10).
Step 13: Plug the LUMI-Loc™ lamp connector into the lamp. Note the keying for proper alignment (see Figure 9a, 9b). Insert the lamp connector into the gland nut and turn the connector approximately % turn to lock the connector to the gland nut as in Figure 11.

REN WATER HO 5 1 UV Water Purification System-
connector

Step 14: Tighten the captive ground screw to the ground lug on the UV reactor to ensure proper grounding.

Step 15: Your system is now ready to be plugged into the appropriate GFCl protected outlet.
Refer to the following section before any water is allowed to flow through the system.

System Sizing

All LUMINOR UV systems are rated for a specific flow rate in water that meets the quality param PLEASE NOTE that increasing the flow above this rating or disinfecting efficacy of the system.
If you need to determine your maximum flow rate, you can fill a 1 gallon bucket with water and time how long it takes to fill up. It is always better to oversize your system then to undersize. For

Location

For Point of Entry (POE) systems, choose a location where the main cold water line is accessible.
The system must be installed after other water treatment equipment (softener or filters), but the faucet. LUMINOR recommends that a 5 micron filter be installed before final polishing step before the water is disinfected

REN WATER HO 5 1 UV Water Purification System-
location

To facilitate lamp removal, ensure there is enough space at the lamp connector end to safely remove the UV lamp and/or quartz sleeve (See Figure 2). The controller will require a ground fault circuit interrupter (GFCI or GFI) outlet and should be mounted beside or above the reactor.
PLEASE NOTE: All LUMINOR UV disinfection’ systems are intended for indoor use only as they should not be exposed to the elements.

System Troubleshooting

Hard Alarms: The following give a constant audible alarm. If present, the solenoid valve is closed, and the 4-20, remote alarm and wifi modules transmit the alarm.

System Display Problem Resolution
The system has detected a problem with the
lamp. Reset lamp protection circuit -unplug unit for 10 seconds. Replace the

lamp with the part as indicated on the silver label on the reactor or on the Maintenance parts screen.
| Although the lamp is powered and visibly
illuminated, due to the lamp’s age its UV output
is no longer sufficient for proper disinfection**.| Replace the lamp with the part as indicated on the  silver label on the reactor or on the Maintenance parts screen.
| Low UV Intensity.| Remove and clean the quartz sleeve and sensor. Check water quality meets requirements on page 5 and add filtration as required. Replace lamp.
| Wrong lamp or sensor installed.| Replace component with proper model as indicated.
| The UV sensor is no longer communicating
with the system.| Ensure all modules are connected properly to the system and to each other.
Modules can be tested indi­vidually by plugging in one at a time and cycling power to the system.
Replace any module that is not detected when plugged directly into the controller.
| A bad connection has been detected in the IEP
port.
| Missing or incorrect lamp key.| Ensure the lamp key (packed with the lamp, on the connector) is installed. Unplug and reinstall the key. Ensure the key part number matches Lamp on Mainte­nance Parts screen.

Soft Alarms: The following remaining errors give a 15 second audible chirp only

System Display Problem Resolution

|

The module indicated is no longer communicating to with the system.

| Ensure all modules are connected properly to the system and to each other.
Modules can be tested individually by plugging in one at a time and cycling power to the system.
Replace any module that is not detected when plugged directly into the controller.
| Refer to flow meter manual for detailed troubleshooting

Warning: After any hard alarm, the home or facility should be disinfected”. Follow the steps under the “System Preparation” heading.
Boil Water Advisory: If any failure occurs on a BLACKCOMB UV system, the water must not be used for human consumption until the system is returned to normal operational mode. If the water is used for human consumption during this period, the water must be boiled (minimum 20 minutes at a full boil) prior to consumption.

Temperature Management Devices
Your LUMINOR BLACKCOMB system is designed to run continuously to ensure optimal disinfection™. However, during periods when no water is drawn through the system, the energy from the disinfection”” process can cause the temperature of the water inside the chamber to rise. In extreme situations elevated water temperature or the fluctuation in temperature can lower the output of the UV lamp. In these cases, or if the elevated water temperature is a nuisance, LUMINOR recommends one of the following forms of temperature management devices.

Cooling Fan
Designed for use on the BLACKCOMB-HO systems, the “LUMI-cool™” fan runs continuously to cool the water by forced convection. The long-ife fan is powered independently using a compact modular power adapter that operates from 100-240V/50-60Hz. £10%. The cooling fan must only be supplied at SELV. Order PN 130014.

Temperature Relief Valve (TRV)
On reaching a higher temperature, the TRV is designed to drain a small amount of water to allow fresh, cooler water to enter the system. The TRV works without power and comes complete with 10’ of drain line. Order PN 130031 for 1/2” ports, PN 130032 for 3/4” ports, PN 130033 for 1” ports and PN 130034 for 1 1/2” ports.

Expansion Modules
BLACKCOMBS and BLACKCOMBF controllers incorporate an “Infinite Expandability Port” (IEP) which allows for expansion to the UV sensor and all other modules. Each module (including the sensor) comes with both a male and female connection. Connect any device to the controller and all subsequent devices are then connected into the female end of last device added in a “daisy chain” configuration. The UV sensor must only be supplied at SELV.

The following optional expansion modules are available for use on BLACKCOMBS and BLACK-COMB® UV controllers. Contact your authorized distributor for purchasing information.
REMOTE ALARM CONNECTION MODULE: Allows for a connection to a remote device such as a buzzer, light, alarm system, PLC, etc., via a pair of contacts. In normal operation the OK and COM contacts will be connected, and in a fault condition (Low UV, Lamp fail, Power Fail), the Fault and COM contacts will be connected. Maximum contact rating is 30V / 1A (use 16-22 AWG). The remote alarm module must only be supplied at SELV. Order PN MOD-RAM.

Typical POE Installation

REN WATER HO 5 1 UV Water Purification System- remote1

HO- Equipment Specifications

Model Flow Rate(30mEcni) @95% UVT)| RW-ULX41 RW-ULX46

5 GPM

| RW-ULX43
RW-ULX4710 GPM| RW-ULX42
RW-ULX4815 GPM| RW-ULX44
RW-ULX4925 GPM| | RW-ULX45
RW-ULX5040 GPM
---|---|---|---|---|---|---
18.91 1pm| 37.91pm| 57Ipm| 951pm| | 151 1pm
1.1 rd/hr| 2.3 of/hr| 3.4 nt/hr| 5.73/hr| | 9.3 nt/hr
Flow Rate (16mEad) @ 95% UVT)| 8 GPM| 19 GPM| 27 GPM| 47 GPM| | 78 GPM
30.3 Ipm| 71.9Ipm| 102.2 Ipm| 178 Ipm| | 295 Ipm
1.8 rrf/hr| 4.3 nt/hr| 6.1 m’/hr| 10.7 ni/hr| | 17.7 ni/hr
Flow Rate (40mEcni) @ 95% UVT)| 3 GPM| 7 GPM| 11 GPM| 19 GPM| | 31 GPM
11.4Ipm| 26.5 1pm| 41 Ipm| 72Ipm| | 117 1pm
0.7 rd/hr| 1.6 rd/hr| 2.5 rd/hr| 4.3 of/hr| | 7.0 of/hr
Port Size| 1/2″MNPT| 3/4″MNPT| 1″MNPT| 1″MNPT| | 1 1/2″MNPT
Electrical| 100-240V/50-60Hz. ±10%. 1.5A Max.|
Plug Type| American: NEMA 5-15P|
Lamp Watts| 18| 34| 45| 67| | 101
Power (Watts)| 20 (19 @ 230V)| 38 (36 @ 230V)| 57 (48 @ 230V’,| 73 (72 @ 230V)| | 115 (108 @230V)
Replacement Lamp| RW-ULX153| RW-ULX156| RW-ULX159| RW-ULX162| | RW-ULX165
Replacement Sleeve| RW-ULX244| RW-ULX246| RW-ULX247| RW-ULX249| | RW-ULX252
Chamber Material| 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated
Reactor Dimensions| 3.5 x 11.7″
(8.9 x 29.8cm)| 3.5 x 16.5″
(8.9 x 41.8cm)| 3.5 x 20.0″
(8.9 x 50.8cm)| 3.5 x 26.9″
(8.9 x 68.3cm)| 3.5 x 40.7″
(8.9 x 103.4cm
Controller Dimensions| 8.6 x 4.2 x 4″ (21.7 x 10.8 x 10.2 cm)|
Operating Pressure| 0.7-10.3 bar (10-150 psi)|
Operating Water Temp| 36-104° F (2-40° C)
UV Monitor| OPTIONAL on all LCD colour screen models. NOT available on LED models.
Solenoid Output| YES (optional solenoid module sold separately)|
Dry Contacts| YES (remote alarm module sold separately)|
4-20mA Output| YES (4-20mA module sold separately)|
Lamp Change Reminder| YES (both audible and visual (full colour graphic))|
Lamp Out Indicator| YES (both audible and visual (full colour graphic))|
Shipping Weight| 9.9 lbs (4.4 kg)| 11.5 lbs (5.2 kg| 12.9 lbs (5.6 kg’| 15.5 lbs (7.0 kg| 21.1 lbs (9.6 kg.

Guaranteed OEM Lamp Replacement with Lightlock™ technology
Protect your replacement lamp revenue stream with REN WATER’s truly proprietary UV lamps with Lightlock™ technology. Maintain your lamp sales, and more importantly your lamp margin, all while protecting the integrity of the product and its performance.

Optional Equipment Modules

UV Concierge
Available for WEB, i0S, and Android platforms providing live, dynamic feedback on all features and functions of your UV system.

SHERPA Series Water Quality Monitor
Allows for remote monitoring of all major and minor alarms that take place on the UV system. Three LED’s visually display system functionality from up to 150″ (46m) away.

Custom Dealer Programmer
Customize your UV controller with your own company name, logo, website, QR code and contact information. Capture the lucrative replacement lamp market by creating a direct link back to your own website!
REN WATER HO 5 1 UV Water Purification System- icon13 UV Sensor Module
Allows the UV intensity to be measured and displayed via the controller. The sensor plugs directly into the controller and is mounted in the sensor port located on all reactors. (see chart for part numbers)

Solenoid Module
Used to power a remote normally closed solenoid valve (not included). Solenoid will close on lamp failure or when low UV conditions are detected by the sensor. Available in 110V. (MOD-SOL1) or 230V. (MOD-SOL2)

TRV (temperature management relief valve)
TRV allows for a small amount of water to be physically released (dumped) from the UV unit to allow for cooling of the water. Used in applications of extended “no flow” conditions, or when the temperature of the treated water is of a critical nature.

4-20mA Module
Used for signal transfer to a remote device such as a data logger or computer. Order MOD-420.

Remote Alarm (Dry Contact) Module
Used for signal transfer to a remote alarm or dry contacts. Order MOD-RAM.

Manufacturer’’s Warranty
REACTORS—Ten (10) year Limited Warranty
ELECTRONICS—Three (3) year Limited Warranty
UV LAMPS—One (1) year Limited Warranty
QUARTZ SLEEVES—One (1) year Limited Warranty

Contact Ren Water
for complete warranty
document, including
conditions and exclusions. EPA Establishment

088776:CAN-001

REN WATER LLC
836 Bill France Blvd
Daytona Beach, Florida
32117
1-800-240-5574
www.renwater.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals