REN WATER HO 5.1 UV Water Purification System User Manual
- June 16, 2024
- REN WATER
Table of Contents
HO 5.1
UV WATER PURIFICATION SYSTEM
- 5 to 40 GPM
- Colour screen controller
- Lightlock™ technology for protected lamp replacement sales
Product Features
- Free floating (no cable twist), keyed-in-place, 254nm Teflon® based UV sensor measures continuously, displaying UV intensity as a % – std. Optional on all LCD colour screen models
- Colour screen controller with Lightlock™ for protected lamp replacement, includes QR codes, full diagnostics & warnings
- Expandability port for future upgrades and options
- Axial flow, 316L stainless steel polished reactors, designed & manufactured to ASME pressure vessel standards
- Simple lamp changes
- Reliable, industry proven, proprietary low pressure, high-output, coated UV lamps with ceramic bases for durability and long life
- Constant current electronic controller in a splash proof case
- Full customization available as an option — language, home screen, phone number, QR codes, etc.
If you are looking for UV water treatment for your home, REN WATER has the
solution in the HO series of residential UV systems.
REN WATER-HO provides UV water treatment for your home with the inclusion of a
true 254nm Teflon® based UV sensor that continuously monitors the performance
of the UV system, displaying the output via a colour screen (optional on 5.1
systems). In addition to UV output, diagnostics, system status, warnings and
QR codes can also be displayed. With the integral expandability port, the
addition of a 4-20mA output or a solenoid valve is a simple plug-and-play
option.
Sample Screens
Point-of-Use (POU)
RW-ULX41/46, for flow rates of 19 Ipm (5 gpm)
Point-of-Entry (POE)
RW-ULX43/47, for flow rates of 38 [pm (10 gpm)
RW-ULX42/48, for flow rates of 57 Ipm (15 gpm)
RW-ULX44/49, for flow rates of 95 Ipm (25 gpm)
RW-ULX45/50, for flow rates of 151 Ipm (40 gpm)
Assembly
Unpack the system and ensure all the components are included with the system.
Your system is shipped with the following components:
BLACKCOMSB (Standard output lamp systems)
Installation
Stepl: The reactor can be installed either horizontally or vertically
using the clamps provided. Vertical installation is the preferred method with
the inlet at the bottom (lamp connection at the top) as it allows any air that
may be in the lines to be easily purged from the system.
Step2: The use of a by-pass assembly is recommended as it will allow you
to isolate the UV reactor. This will allow for easier access in case
maintenance is required (See Figure 4).
Step3 : Fasten chamber clamps to wall with screws provided. The screws
must anchor securely into solid wood, concrete, or steel structure for
adequate strength. Do not attempt to secure screws into drywall (Figure 3a).
Install Chamber into clamps (Figure 3b).
Step4: For water supplies where the maximum flow rate is unknown, a flow
restrictor is recommended so that the rated flow of your particular BLACKCOMB
system is not exceeded. The flow restrictor should be installed on the inlet
port of the reactor.
Step5: Itis recommended to have a licensed plumber connect the UV reactor
to the water supply and may be a requirement depending on where you are
located.
Step 11: Always hold UV lamps by their ceramic ends, not by the lamp quartz. Remove the lamp from its packaging. Again, the use of cotton gloves is recommended. Remove the lamp key from the lamp’s connector and set it aside for the next step. Be careful to not touch the key’s exposed contacts. Insert the UV lamp into the reactor, being careful not to drop it.
Step 12: Install the lamp key into the controller (BLACKCOMBS,
BLACKCOMBS systems only). The key always comes packaged with the lamp and
sits on the connector. With the key removed from the lamp, orient it so the
label is upright and facing you. The key will plug into the lamp key port on
the right side of the controller (Figure 10).
Step 13: Plug the LUMI-Loc™ lamp connector into the lamp. Note the keying
for proper alignment (see Figure 9a, 9b). Insert the lamp connector into the
gland nut and turn the connector approximately % turn to lock the connector to
the gland nut as in Figure 11.
Step 14: Tighten the captive ground screw to the ground lug on the UV reactor to ensure proper grounding.
Step 15: Your system is now ready to be plugged into the appropriate GFCl
protected outlet.
Refer to the following section before any water is allowed to flow through the
system.
System Sizing
All LUMINOR UV systems are rated for a specific flow rate in water that meets
the quality param PLEASE NOTE that increasing the flow above this rating or
disinfecting efficacy of the system.
If you need to determine your maximum flow rate, you can fill a 1 gallon
bucket with water and time how long it takes to fill up. It is always better
to oversize your system then to undersize. For
Location
For Point of Entry (POE) systems, choose a location where the main cold water
line is accessible.
The system must be installed after other water treatment equipment (softener
or filters), but the faucet. LUMINOR recommends that a 5 micron filter be
installed before final polishing step before the water is disinfected
To facilitate lamp removal, ensure there is enough space at the lamp connector
end to safely remove the UV lamp and/or quartz sleeve (See Figure 2). The
controller will require a ground fault circuit interrupter (GFCI or GFI)
outlet and should be mounted beside or above the reactor.
PLEASE NOTE: All LUMINOR UV disinfection’ systems are intended for indoor
use only as they should not be exposed to the elements.
System Troubleshooting
Hard Alarms: The following give a constant audible alarm. If present, the solenoid valve is closed, and the 4-20, remote alarm and wifi modules transmit the alarm.
System Display | Problem | Resolution |
---|---|---|
The system has detected a problem with the | ||
lamp. | Reset lamp protection circuit -unplug unit for 10 seconds. Replace the |
lamp with the part as indicated on the silver label on the reactor or on the
Maintenance parts screen.
| Although the lamp is powered and visibly
illuminated, due to the lamp’s age its UV output
is no longer sufficient for proper disinfection**.| Replace the lamp with the
part as indicated on the silver label on the reactor or on the Maintenance
parts screen.
| Low UV Intensity.| Remove and clean the quartz sleeve and sensor. Check
water quality meets requirements on page 5 and add filtration as required.
Replace lamp.
| Wrong lamp or sensor installed.| Replace component with proper model as
indicated.
| The UV sensor is no longer communicating
with the system.| Ensure all modules are connected properly to the system and
to each other.
Modules can be tested individually by plugging in one at a time and cycling
power to the system.
Replace any module that is not detected when plugged directly into the
controller.
| A bad connection has been detected in the IEP
port.
| Missing or incorrect lamp key.| Ensure the lamp key (packed with the lamp,
on the connector) is installed. Unplug and reinstall the key. Ensure the key
part number matches Lamp on Maintenance Parts screen.
Soft Alarms: The following remaining errors give a 15 second audible chirp only
System Display | Problem | Resolution |
---|
|
The module indicated is no longer communicating to with the system.
| Ensure all modules are connected properly to the system and to each other.
Modules can be tested individually by plugging in one at a time and cycling
power to the system.
Replace any module that is not detected when plugged directly into the
controller.
| Refer to flow meter manual for detailed troubleshooting
Warning: After any hard alarm, the home or facility should be
disinfected”. Follow the steps under the “System Preparation” heading.
Boil Water Advisory: If any failure occurs on a BLACKCOMB UV system, the
water must not be used for human consumption until the system is returned to
normal operational mode. If the water is used for human consumption during
this period, the water must be boiled (minimum 20 minutes at a full boil)
prior to consumption.
Temperature Management Devices
Your LUMINOR BLACKCOMB system is designed to run continuously to ensure
optimal disinfection™. However, during periods when no water is drawn through
the system, the energy from the disinfection”” process can cause the
temperature of the water inside the chamber to rise. In extreme situations
elevated water temperature or the fluctuation in temperature can lower the
output of the UV lamp. In these cases, or if the elevated water temperature is
a nuisance, LUMINOR recommends one of the following forms of temperature
management devices.
Cooling Fan
Designed for use on the BLACKCOMB-HO systems, the “LUMI-cool™” fan runs
continuously to cool the water by forced convection. The long-ife fan is
powered independently using a compact modular power adapter that operates from
100-240V/50-60Hz. £10%. The cooling fan must only be supplied at SELV. Order
PN 130014.
Temperature Relief Valve (TRV)
On reaching a higher temperature, the TRV is designed to drain a small amount
of water to allow fresh, cooler water to enter the system. The TRV works
without power and comes complete with 10’ of drain line. Order PN 130031 for
1/2” ports, PN 130032 for 3/4” ports, PN 130033 for 1” ports and PN 130034 for
1 1/2” ports.
Expansion Modules
BLACKCOMBS and BLACKCOMBF controllers incorporate an “Infinite Expandability
Port” (IEP) which allows for expansion to the UV sensor and all other modules.
Each module (including the sensor) comes with both a male and female
connection. Connect any device to the controller and all subsequent devices
are then connected into the female end of last device added in a “daisy chain”
configuration. The UV sensor must only be supplied at SELV.
The following optional expansion modules are available for use on BLACKCOMBS
and BLACK-COMB® UV controllers. Contact your authorized distributor for
purchasing information.
REMOTE ALARM CONNECTION MODULE: Allows for a connection to a remote
device such as a buzzer, light, alarm system, PLC, etc., via a pair of
contacts. In normal operation the OK and COM contacts will be connected, and
in a fault condition (Low UV, Lamp fail, Power Fail), the Fault and COM
contacts will be connected. Maximum contact rating is 30V / 1A (use 16-22
AWG). The remote alarm module must only be supplied at SELV. Order PN MOD-RAM.
Typical POE Installation
HO- Equipment Specifications
Model Flow Rate(30mEcni) @95% UVT)| RW-ULX41 RW-ULX46
5 GPM
| RW-ULX43
RW-ULX4710 GPM| RW-ULX42
RW-ULX4815 GPM| RW-ULX44
RW-ULX4925 GPM| | RW-ULX45
RW-ULX5040 GPM
---|---|---|---|---|---|---
18.91 1pm| 37.91pm| 57Ipm| 951pm| | 151 1pm
1.1 rd/hr| 2.3 of/hr| 3.4 nt/hr| 5.73/hr| | 9.3 nt/hr
Flow Rate (16mEad) @ 95% UVT)| 8 GPM| 19 GPM| 27 GPM| 47 GPM| | 78 GPM
30.3 Ipm| 71.9Ipm| 102.2 Ipm| 178 Ipm| | 295 Ipm
1.8 rrf/hr| 4.3 nt/hr| 6.1 m’/hr| 10.7 ni/hr| | 17.7 ni/hr
Flow Rate (40mEcni) @ 95% UVT)| 3 GPM| 7 GPM| 11 GPM| 19 GPM| | 31 GPM
11.4Ipm| 26.5 1pm| 41 Ipm| 72Ipm| | 117 1pm
0.7 rd/hr| 1.6 rd/hr| 2.5 rd/hr| 4.3 of/hr| | 7.0 of/hr
Port Size| 1/2″MNPT| 3/4″MNPT| 1″MNPT| 1″MNPT| | 1 1/2″MNPT
Electrical| 100-240V/50-60Hz. ±10%. 1.5A Max.|
Plug Type| American: NEMA 5-15P|
Lamp Watts| 18| 34| 45| 67| | 101
Power (Watts)| 20 (19 @ 230V)| 38 (36 @ 230V)| 57 (48 @ 230V’,| 73 (72 @
230V)| | 115 (108 @230V)
Replacement Lamp| RW-ULX153| RW-ULX156| RW-ULX159| RW-ULX162| | RW-ULX165
Replacement Sleeve| RW-ULX244| RW-ULX246| RW-ULX247| RW-ULX249| | RW-ULX252
Chamber Material| 316L Stainless Steel, A249 Pressure Rated Tubing, Polished &
Passivated
Reactor Dimensions| 3.5 x 11.7″
(8.9 x 29.8cm)| 3.5 x 16.5″
(8.9 x 41.8cm)| 3.5 x 20.0″
(8.9 x 50.8cm)| 3.5 x 26.9″
(8.9 x 68.3cm)| 3.5 x 40.7″
(8.9 x 103.4cm
Controller Dimensions| 8.6 x 4.2 x 4″ (21.7 x 10.8 x 10.2 cm)|
Operating Pressure| 0.7-10.3 bar
(10-150 psi)|
Operating Water Temp| 36-104° F (2-40° C)
UV Monitor| OPTIONAL on all LCD colour screen models. NOT available on LED
models.
Solenoid Output| YES (optional solenoid module sold separately)|
Dry Contacts| YES (remote alarm module sold separately)|
4-20mA Output| YES (4-20mA module sold separately)|
Lamp Change Reminder| YES (both audible and visual (full colour graphic))|
Lamp Out Indicator| YES (both audible and visual (full colour graphic))|
Shipping Weight| 9.9 lbs (4.4 kg)| 11.5 lbs (5.2 kg| 12.9 lbs (5.6 kg’| 15.5
lbs (7.0 kg| 21.1 lbs (9.6 kg.
Guaranteed OEM Lamp Replacement with Lightlock™ technology
Protect your replacement lamp revenue stream with REN WATER’s truly
proprietary UV lamps with Lightlock™ technology. Maintain your lamp sales, and
more importantly your lamp margin, all while protecting the integrity of the
product and its performance.
Optional Equipment Modules
UV Concierge
Available for WEB, i0S, and Android platforms providing live, dynamic feedback
on all features and functions of your UV system.
SHERPA Series Water Quality Monitor
Allows for remote monitoring of all major and minor alarms that take place on
the UV system. Three LED’s visually display system functionality from up to
150″ (46m) away.
Custom Dealer Programmer
Customize your UV controller with your own company name, logo, website, QR
code and contact information. Capture the lucrative replacement lamp market by
creating a direct link back to your own website!
UV Sensor Module
Allows the UV intensity to be measured and displayed via the controller.
The sensor plugs directly into the controller and is mounted in the sensor
port located on all reactors. (see chart for part numbers)
Solenoid Module
Used to power a remote normally closed solenoid valve (not included).
Solenoid will close on lamp failure or when low UV conditions are detected by
the sensor. Available in 110V. (MOD-SOL1) or 230V. (MOD-SOL2)
TRV (temperature management relief valve)
TRV allows for a small amount of water to be physically released (dumped) from
the UV unit to allow for cooling of the water. Used in applications of
extended “no flow” conditions, or when the temperature of the treated water is
of a critical nature.
4-20mA Module
Used for signal transfer to a remote device such as a data logger or
computer. Order MOD-420.
Remote Alarm (Dry Contact) Module
Used for signal transfer to a remote alarm or dry contacts. Order MOD-RAM.
Manufacturer’’s Warranty
REACTORS—Ten (10) year Limited Warranty
ELECTRONICS—Three (3) year Limited Warranty
UV LAMPS—One (1) year Limited Warranty
QUARTZ SLEEVES—One (1) year Limited Warranty
Contact Ren Water
for complete warranty
document, including
conditions and exclusions. EPA Establishment
088776:CAN-001
REN WATER LLC
836 Bill France Blvd
Daytona Beach, Florida
32117
1-800-240-5574
www.renwater.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>