BioShieldUV SL18-AC HVAC Transformer Installation
Product Information
Specifications
- Model: BioShield SL18-AC
- Type: HVAC Transformer
- Power: 18W
- Lamp Type: Incandescent UV Lamp
- Installation Method: Direct Wire to Transformer
Safety Precautions
- Make sure to turn off the main power switch before plugging in or performing any maintenance on the device.
- Electrical shock can cause injury or death, so check all disconnect switches.
- Avoid touching the lamp glass without gloves. If touched, clean it with isopropyl alcohol.
- Never expose eyes directly to UV light and wear safety glasses during installation.
- Do not touch a broken lamp or its contents as it contains mercury. If exposed, wash it off with mild soap.
- Read the manual carefully before attempting to install it.
- Improper installation, adjustment, alteration, service, or maintenance may cause fire, electrical shock, and personal injury or property damage.
- If you need help during installation, consult a licensed electrician or contractor.
UV-C Lamp Disposal
For proper disposal of used UV lamps:
- Visit www.earth911.com for your local or state waste management program.
- Contact local hardware, home improvement stores, or retailers selling UV and fluorescent bulbs for recycling options.
- If recycling is not available, seal the bulb in a plastic bag and dispose of it with regular trash collection (if acceptable by local waste management).
Items Included
- 18w Incandescent UV Lamp
- Ballast
- 3/8 Viewport
- Drill Bit
- Magnetic Holder
- Transformer
Installation Guide
Part 1: Magnetic Bracket & Lamp Installation
- Wear gloves when touching the UV Lamp.
- Find a suitable location for installation.
- Attach the UV Lamp to the magnetic bracket.
- Connect the 4 pin UV plug to the UV Lamp.
- Position the metal bracket onto the back or side wall of the air handler.
Part 2: Wiring Installation
Note : This model (BioShield SL18-AC) needs to be connected to a 24V AC
transformer. If you have a different model (SL18-DC), it can be plugged
directly into an outlet.
- Verify that the existing HVAC transformer has enough amperage allowance for the additional 1.1amp draw from the UV light. If not, use a higher amp or separate transformer specifically for the UV light.
- Connect the Ballast to the 24V HVAC Transformer following the provided diagram.
FAQ (Frequently Asked Questions)
-
Q: What should I do if I ordered the wrong model?
A: If you ordered the wrong model, please contact us to arrange an exchange. -
Q: Can I touch the lamp glass without gloves?
A: No, it is recommended to wear gloves when touching the lamp glass. If you accidentally touch it, clean it with isopropyl alcohol. -
Q: Can I recycle the used UV lamp?
A: Yes, many hardware stores, home improvement stores, and retailers accept used bulbs for recycling. You can also check your local waste management program for proper disposal instructions.
DID YOU ORDER THE RIGHT MODEL?
BioShield SL18 Models
- SL18-DC: Direct plugged into a power outlet
If you ordered the wrong model, please contact us to exchange.
**Safety Precautions
**
FOLLOW ALL SAFETY AND BUILDING CODES
Make sure to turn off its main power switch before you plug in or perform any maintenance on the device.
- Electrical shock can cause injury or death.
- There may be more than one disconnect switch —so check them all!
Please do not touch the lamp glass without gloves.
- In case you touched the lamp’s bulb, wipe it clean with isopropyl alcohol.
- If the lamp is not cleaned, the film of hand oils causes a reduction in the light intensity.
Never expose eyes directly to UV light.
- Looking at the UV lamp may cause eye damage.
- Wear safety glasses during installation.
Never touch a broken lamp, and avoid touching its contents. The lamp contains mercury.
- If you get any of the substance on your skin, wash it off with mild soap.
- if the bulb breaks, clean up carefully and dispose of it.
Read the manual carefully before attempting to install it.
- Improper installation, adjustment, alteration, service, or maintenance may cause fire or electrical shock and create the potential for personal injury or property damage.
- Please consult a licensed electrician or contractor if you need help during the installation.
UV-C Lamp Disposal
Visit www.earth911.com for your local or state waste management program and information about where to dispose of the used UV Lamp.
Contact your local hardware, home improvement stores, and other retailers
selling UV and fluorescent bulbs. Many stores allow customers to drop off used
bulbs for recycling.
If you cannot recycle, and it is acceptable with your local waste management
agency, you may seal the bulb in a plastic bulb and put it in the trash for
collection.
Items Included
BEFORE INSTALLATION
- Turn off HVAC system and ensure all electrical connections are off.
- Installation to be done by a certified HVAC technician and must comply with all national and local electrical and mechanical codes.
MAGNETIC BRACKET & LAMP INSTALLATION
Please use gloves when touching the UV Lamp.
- Find a suitable location
- Attach the UV Lamp to the magnetic bracket
- Connect the 4 pin UV plug to the UV Lamp
- Position the metal bracket onto the back or side of wall of air handler.
WIRING INSTALLATION
NOTE : This particular model needs to be connected to a 24V AC transformer. However, BioShieldUV also offers a different model (SL18-DC) that does not require wiring and can be simply plugged into an outlet.
- Verify the existing HVAC transformer has enough amperage allowance for the additional 1.1amp draw from the UV light. If not, you must use a higher amp or separate transformer just for the UV light.
- Connect the Ballast to the 24V HVAC Transformer. See the diagram below.
Diagram
Note : BioShieldUV and its staff cannot provide any technical assistance
with the installation.
Not only is each HVAC transformer different, but the installation must be done
by a licensed professional. BioShieldUV can only provide the hardware, tools,
and generic installation steps/principles.
VIEWPORT INSTALLATION
- Find the desired spot to drill on the exterior ductwork where the viewport won’t be blocked by anything.
- Press the viewport plastic into the hole. Ensure air handler or panels are closed.
- If necessary, use a seal or clear tape to secure the viewport from falling. Turn on UV Lamp.
Replace bulbs every 6 months
- The lamp bulb is rated for about 8,000 hours of use under continuous operation
- The diminish of blue light is normal overtime. UV rays are invisible to the naked eye.
- All for BioShieldUV devices use the LED indicator on the device to confirm if UV bulb is functional or requires replacement.
- For BioSL18-AC (Where no indicator light is available) you can use a voltmeter and test the bulb for a close circuit to verify if the light is still working.
Order your bulb replacement
here:www.bioshielduv.com/bulbs
Lamp part number: SKUBioSL18-UV bulb
Get 15% Off + Lifetime Warranty Join the BioShield Guardian Club!
FIVE Years Extended Warranty
- Scan the QR Code
- Must register the product within 60 days
visit www.bioshielduv.com/warranty
Lifetime Unit Warranty
BioShield Guardian Club EXCLUSIVE!
Plus :
- Sign up is FREE (Zero Cost)
- 15% off on bulbs
- Auto-ship every 6 months
- Free Shipping
Sign Up Now!
- Scan the QR Code
- Must sign up within 30 days of purchase
or visit www.bioshielduv.com/club
CONTACT US
Text or Call
US & Canada
+1 (307) 364 0340
WhatsApp
Message, Photo, Video Only+1 (307) 354 3303
Email
support@bioshielduv.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>