BrainU Sleepade Monitoring System Sleeping Care System User Manual

June 16, 2024
BrainU

SLEEPade MANUAL

USER MANUAL
V.1.0.0, 2022-04-28

Precautions for Use

  • General Precautions
    – This product cannot be used for any other purpose (i.e. it cannot be used for purposes other than sleep evaluation).
    – Before using the product, check the precautions and how to use it.
    – Do not allow conductive foreign substances (e.g. liquid, dust or metal powder) to contact the electrodes and charging terminals of the main body.
    – Unauthorized disassembly or reassembly is prohibited.
    – SLEEPade’s battery replacement is only available at designated companies.
    – Use only the power supply provided by the manufacturer.
    – Do not use on wounds.
    – Do not attach to the body part other than the forehead.
    – If rash or other abnormal symptoms occurs at the site, stop using it immediately.
    – SLEEPade patch (sold separately) is disposable. Do not use again.
    – Keep out of reach of children.
    – When a cyber security threat is detected, disconnect the Bluetooth and power off the device.
    Then, contact us at local distributor to take appropriate actions.

  • Precautions before Use
    – Check if the battery of SLEEPade body is sufficient.
    – Make sure you have the latest version of the SLEEPade App.

  • Precautions during Use
    – Be careful not to let the SLEEPade fall off your forehead before going to bed.
    – If you feel any discomfort or pain while using SLEEPade, remove it immediately.

  • Storage
    – Wipe the product with a soft cloth when contaminated.
    – Store in the SLEEPade charging casing (remove the charging cable when not in use for a long time).
    – If repair is required, contact the designated companies or service center for repair.

  • Disposal
    – SLEEPade patch (sold separately) is disposable. Do not use again.
    – Disposable SLEEPade patches should be discarded in the standard plastic bags.

How to Download the App

Installation
Search for [SLEEPade] on Google Play or App Store and download it.

Caution
Download via Wi-Fi.
Data charges may occur in LTE or 5G networks.

Activate the App
Run the downloaded [SLEEPade] to measure your sleep.

Please allow the following to use the application normally.

Bluetooth / LBS
Used to search for the SLEEPade device.

Microphone
Used to measure ambient decibels during sleep.

Please enable the followings to use additional features.

Wi-Fi/Data
To provide real-time weather information and recommendations.

Items

Iltems Qty Remarks
SLEEPade Body 1EA
SLEEPade Patch Sold separately
Charging (Storage) Casing 1EA
USB-C Type Charging Cable 1EA Length:

1 m
User Manual| 1EA| –
Iltems| Warranty Period
---|---
SLEEPade Body| 1 year
Other accessories other than the items above are not applicable.
Charging (Storage) Casing

  • The warranty service of the SLEEPade body includes a 1-year battery service.
    Paid battery service provided by BrainU is available when the warranty period has elapsed, and the cost may vary depending on the situation.
  • Even within the warranty period, we may charge service fees for damage caused by unauthorized disassembly or submersjon.

Operations

Align the charging terminal of the SLEEPade main body with the port of the charging casing, insert into the port.
Connect the USB-C type charging cable to charge the SLEEPade main body.

You can turn ON/OFF the power by pressing the button on the top of the SLEEPade body.
You can check the battery status of the device by the LED blinking.

Charging (Storage) Casing

SLEEPade Body

  1. Tumed ON

  2. Blinks once every 3 seconds after Bluetooth connection

How to Use

Preparation

  1. Remove the protective film.

  2. Apply the patch.
    Type-1
    (Patch with Hydrogel)| Type-2
    (Patch without Hydrogel)
    ---|---
    Attach the patch from the end with the hydrogel facing upward and attach it to the main device as shown in the figure below.
    Remove the clear protective film so that you can attach it to your forehead.| Attach the patch from the end with the transparent protective film facing upward,  and attach it to the device as shown in the figure below.
    Remove the clear protective film so that you can attach it to your forehead..
    |

  3. Attach the SLEEPade.
    Wipe off sweat and dust from the attachment area, attach the wdevice to the center of the upper part of the forehead, and press firmly.

Connection

  1. Connect SLEEPade.
    When you run the installed application, the device is automatically connected. If it is not connected, press the Search button to connect.
    For the connected device, the LED blinks slowly.

  2. Respond to the SLEEPade questionnaires.
    You can answer 6-point scale questionnaires if you want to (you can skip it).
    If you press the “Sleep Start” button in the Monitoring, it will switch to the Measurement.

Measurement

  1. Connect the SLEEPade.
    Caution
    (1) Do not forcibly close the SLEEPade app once sleep measurement starts.
    (2) You can switch between apps. However, it is recommended to use it right before sleep for accurate sleep measurement.
    Press the button to start measuring sleep.

  2. Start measuring with SLEEPade.
    You can turn sleep ASMR on and off by pressing the button.

Deactivation

  1. Deactivate SLEEPade measurement.
    Press the button to end sleep measurement.

  2. Remove the SLEEPade
    After peeling off the SLEEPade attached to the forehead, cleanly remove the patch attached to the SLEEPade body.

  3. SLEEPade storage/maintenance
    Store (or charge) the SLEEPade body in the charging/storage casing.

  • Please refer to page 5 of this manual for how to charge SLEEPade.
  • Please refer to page 2 of this manual for storage/maintenance of SLEEPade.

Your Sleep Results

Latest Report

On the Latest Report, you can check the last measured sleep data.

  1. Latest Report
    The latest report is displayed on the sleep report screen.

  2. Cumulative Report
    The cumulative report is displayed on the sleep report screen.

  3. Select the Report Date
    You can check the sleep data of the selected date.

  4. Latest Score (caution: it is not a medical device function.)
    Comprehensive sleep data is analyzed to calculate a sleep score.

  5. Sleep Time
    Total Sleep Time: Sleep time.
    Unmeasured Time: While the patch was off during sleep measurement.
    Time Taken to Fall Asleep: Time taken from attaching the sensor to sleep.

  6. Sleep Stage
    Sleep stages will be shown in percentage and duration.

  7. Other Scores
    Displays waking, tossing and snoring levels during sleep.

  8. Sleep Stage Graph
    Visualizes your sleep stages over time.

Your Sleep Results

Cumulative Report

On the Cumulative Report, you can check the average of all the measured sleep data.

  1. Select Date
    You can easily check your sleep data by week, month, year, and last month.

  2. Select Period
    You can check your sleep data by selecting a specific period.

  3. Sleep Score (caution: it is not a medical device function.)
    You can compare the average score for the selected period with the overall average score.

  4. Recommendations
    It analyzes the average sleep data and the sleep data of the selected period to provide recommendations to help you sleep.

  5. Sleep Stage Graph
    Displays the percentage of sleep stages by date.

  6. Sleep Monitoring Report
    You can easily check and delete your sleep data.

Environmental Precautions

Environmental Precautions

  • Do not use near fire or flammable substances.
  • Do not use in damp or wet places.
  • Do not use in dusty places.
  • Do not use in places where there is a risk of product overheating.
  • Do not use in environments where malfunctions may occur due to strong external shocks and other electronic devices.

For Storing & Using SLEEPade

Temperature 15~457T
RH 30~95%
Atmospheric Pressure 1060 hPa ~ 700 hPa

SLEEPade has not been tested for water resistance. Do not use in the kitchen or bathroom.

  • We may charge service fees for damage caused by submersion.

Alarms in SLEEPade App

Type of Alarms Details Causes and Actions Required
Warning Poor communication When there is too much noise in the signal.

– Press and hold the SLEEPade device once and wait for a while.
Notice| Device disconnected; rediscover| Bluetooth is disconnected.
– Search the device again in the App
– Check that the SLEEPade device is turned on and wait for a while.
Warning| The sensor has fallen off.| The sensor has been removed.
– Presls and hold the SLEEPade device once until the warning popup disappears.
– If the device completely falls off, replace the patch with a new one and attach it to the forehead again.
Warning| The sensor has fallen off.
Warning| The sensor has fallen off

Safety Symbols

Symbols No Descriptions
IEC 60417-5031 Direct current
ISO 7000-0434A Caution

1SO 3864-1 should bee strictly observed.
Refer to ISO 7010-WO001
(Table D.2 Safety Marking 2).
| ISO 7000-1641| Operating Instructions
| IEC 60417-5333| BF type mounting
| ISO 7000-1051| Do not reuse.
| 1SO 7010-M002| Follow the operating instructions.
(Note) In case of ME equipment, follow the instruction manual
| IEC 60417-5009| Stand-by
| IEC 60529| N,=0: No protection
1: Protection against objects with a diameter of >50 mm
2: Protection against objects with a diameter of > 12.5 mm
3: Protection against objects with a diameter of >2.5 mm
4: Protection against objects with a diameter of > 1.0 mm
5. Dust protected
6: Dust-tight
N,= 0: No protection
1: Dripping water
2: Dripping water when tilted at 15°
3: Spraying water
4: Splashing of water
5: Water jets
6: Powerful water jets
7: Immersion
8: Immersion repeatedly
Note) X can be used when no data available to specify a protection rating (e.g.  “XX” when omitting both numbers).

Specification

SLEEPade Body

Wejght 18g
Sjze 72.0 (W) x 22.0 (D) x 19.0 (H)t
Bluetooth FrequeMcy
VersjoM BLE S.0
RaMge Ç 10 m
Battery 3.7 V 7S mAh x 2EA
OperatjMg Tjme 30 hours (full charge)
ChaMMel EEG 1 chaMMel

SLEEPade Charger

Wejght 4Sg
Sjze 10S.0 (W) x S0.0 (D) x 26.0 (H)z
RatjMg SV S00mA

SLEEPade Patch

Type−1 (ujth Hydrogel) 71.4 (W) x 18 (D) x 1.S (H)
Type−2 (ujthout Hydrogel) 71.4 (W) x 18 (D) x 1.S (H)

Operational Description
Wireless Communication
Operation Frequency: 2402 ~ 2480 MHz
Modulation Type: GFSK
Antenna Type : Multilayer Chip Antenna
Antenna Gain(Peak) : 2.3 dBi

Manufacturer Information
Address: 3F, 7, Yatap-ro 105beongil, Bundang-gu, Sengnam-si, Gyeonggi-do,
Republic of Korea (13506)
E-mail: support@brainu.co.kr
Homepage: www.brainu-cai.com

Certifications
FCCID : 2BBOF – SLEEPADE

FCC Statement

FCC Part 15.19 Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

FCC Part 15.105 Statement (Class B)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may  cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to  try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Part 15.21 Statement
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device must not be co-located or operating in conjunction with any other antenna or transmitter.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals