Product Information

The In-Wall Enclosure for Recessed AV Component Storage and Media Distribution is a versatile product designed to securely store and distribute audiovisual components within the wall. It is available in two sizes: 9-inch and 17-inch.

Specifications

  • Size: 9-inch and 17-inch

Dimensions

  • 9-inch: 9 in. x 14.3 in. x 3.9 in.
  • 17-inch: 17 in. x 14.3 in. x 3.9 in.
  • Includes: Cover, Trim, Bracket, Screws

In-Wall Enclosure for Recessed AV Component Storage and Media Distribution

No: 1507320 Rev. A

INSTALLATION INSTRUCTIONS

Please read these instructions completely before you begin.

IMPORTANT SAFETY INSTRUCTIONS

  1. Do not use this product near water; such as a bath tub, wash bowl, kitchen sink, laundry tub, swimming pool, or in a wet basement.
  2. Never push objects of any kind into this product through openings, as they may touch dangerous voltages. Never touch uninsulated telephone wires or terminals, unless the telephone line has been disconnected at the network interface.
  3. Never install communications wiring, or components, during a lightning storm.
  4. Equipment shall be installed in accordance with ANSI/NFPA 70, National Electrical Code (NEC), NFPA 72, CAN-ULC-S540, Canadian Electrical Code, and/or other applicable sections of ANSI/IEEE C2 & National Electrical Safety Code (NESC). Equipment intended for installation in information technology equipment (computer) rooms should be installed in accordance with NFPA 75, Standard for the Fire Protection of Information Technology Equipment.
  5. Power supplied to components must be provided by UL Listed Class 2 power limited power supply.
  6. All power limited and non-power limited wiring must be separated by a minimum of ¼” spacing.
  7. Installation shall be completed by a professional electrical contractor or low voltage technician.
  8. Maximum load carrying capacity of 30 lb.

CONSIGNES
Lisez et comprenez toutes ces consignes.

Catalog Number

Country of Origin:

  • ENP0905-NA-V1
  • ENP0900-NA ENP0920-NA 9IN IN-WALL ENCLOSURE WITH COVER,
  • TRIM AND BRACKET 9IN IN-WALL ENCLOSURE WITH COVER AND TRIM
  • ENP1705-NA-V1 9IN COVER AND TRIM – REPLACEMENT
  • ENP1700-NA 17 IN-WALL ENCLOSURE WITH SPLIT COVER, TRIM & BRACKET 17IN IN-WALL ENCLOSURE WITH SPLIT COVER AND TRIM
  • ENP1720-NA 17IN COVER AND TRIM – REPLACEMENT

Dimensions

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-01

Product Contents

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-02

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-03

Recommended Tools

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-04

Enclosure Physical Installation

Locate enclosure indoors in a low humidity, climate-controlled (0°C / 32°F – 49°C / 120°F) area within close proximity to a power source. Remove cable knockouts as needed. When required, 2” rubber grommets (AC1034) are available to seal and protect openings. If mounting behind a TV, ensure the box is positioned to be concealed from view by the display.

NEW CONSTRUCTION Installation

Surface Mount
Mount to a plywood backboard using the pre-drilled mounting holes on the rear of the enclosure. The use of a level is recommended for the correct installation of the enclosure.

Flush Mount
The Enclosure is designed to fit between a minimum 2×4 studded wall at 16”on- center (OC). If wall studs are greater than 16” on-center (OC) refer to Retrofit Installation. Position Enclosure between wall studs at appropriate depth (refer to drywall depth guide on enclosure ) and utilize four (4) drywall screws to secure to wall studs.

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-06

Trim Ring Installation
After drywall is installed, use the included six (6) screws to affix the Trim Ring to the corresponding holes located in the enclosure frame.

CAUTION
DO NOT overtighten the screws. legrand-ENP0905NAV1-9-In.-0Media-
Enclosure-7

RETROFIT Installation

Wall Prep
After the desired height is identified, use a stud finder to locate the vertical stud locations. Press the front of the Enclosure on the wall surface and trace the outline. Use a drywall saw to cut the box outline.

Trim Ring Installation
Use the included four (4) screws to affix the Trim Ring to the corresponding holes located in the enclosure frame.

CAUTION : DO NOT overtighten the screws. legrand-ENP0905NAV1-9-In
.-0Media-Enclosure-9

Enclosure Installation

Insert the enclosure into the wall opening and utilize a Philips head screwdriver to engage the four (4) drywall clips in all corners. If near wall studs, you can also utilize drywall screws to secure box from the inside. Once installed in the wall – install the two (2) side screws to secure sides of the trim to the enclosure.

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-10

Power Installation

Running Power to the Installation
Remove desired outlet knockout. Install a single-gang metal outlet box. Connect 15 amp, 120 volt power receptacle to power cable with approved wiring method to local codes.

NOTE : Legrand offers both non-surge-protected (P/N F7526) and surge- protected (364569-02-V1) outlet kits. Only install standard size wall plates as oversized plates will not fit.

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-11legrand-ENP0905NAV1-9-In.-0Media-Enclosure-12

Equipment Mounting Inside Enclosure

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-1

5IN Elevated Mounting Bracket (AC1050)

Included with ENPXX05-NA-V1 versions. The removable component mounting bracket allows organization of devices before or after installation. If desired the bracket includes four (4) plunger / grommets to secure directly to back wall of enclosure – Vertical or Horizontal.

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-13

Built-in Lacing Tabs
The back wall has assorted lacing tabs for securing large equipment directly to the enclosure. The lacing tabs have a protective cover that can be removed by utilizing a screwdriver and pushing the protective cover into the opening to provide an unobstructed guide for hook and loop strapping.

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-14

Cover Installation

legrand-ENP0905NAV1-9-In.-0Media-Enclosure-15

Install the Cover
To attach the cover, position cables exiting the enclosure towards the pass- through opening and slide the bottom tabs into the receiving channels of the trim ring. Push the sides of the cover into the locking side channels for a flush finish. The 17” model has two covers for easy access to contents, even when the enclosure is partially obstructed.