MARSHYDRO M01 Intelligent Fan Controller User Manual
- June 16, 2024
- MARSHYDRO
Table of Contents
M01
MARS HYDRO
Intelligent Fan Controller User Manual
M01 Intelligent Fan Controller
AUTO MODE: HIGH TEMP /LOW TEMP /HIGH HUMID /LOW HUMID
HIGH TEMP
In this mode, press the up or down button to set a high temperature trigger.
The fans will activate if the probe’s measured temperature exceeds the
temperature you have set in this mode. The activated fans will slowly increase
in speed until it reaches the speed set in ON Mode. Whenever the measured
temperature falls below your set temperature, the fans will slowly decrease in
speed until the fans stop. You may also hold the up and down button
simultaneously to turn off this trigger, in which the digits under settings
will show OFF for off. Note that this trigger can activate to run as long as
you are in AUTO Mode, even if you are in setting up the other AUTO Mode
triggers.
The setting method of LOW TEMP /HIGH HUMID / LOW HUMID mode is consistent with
that HIGH TEMP.
ALARM SETTING: HIGH TEMP /LOW TEMP /HIGH HUMID /LOW HUMID
HIGH TEMP
In this settings mode, press the up and down button to set a high temperature
alarm.
The alarm will activate if the probe’s measured temperature exceeds the
temperature you have set in this mode. When the alarm triggers, the fan will
start spinning gradually to max speed regardless of your other settings. You
may also hold the up and down button simultaneously to turn off this alarm
setting, in which the digits under settings will show OFF. You will need to be
in AUTO. ON. or TIMER mode for this alarm to be able to activate.
The setting method of LOW TEMP /HIGH HUMID / LOW HUMID mode is consistent with
that HIGH TEMP.
PAY ATTENTION
When you use the controller for first time, plaese tear off the white tape
attached on the mental proble.
CONTROLLER LOCK
To lock the controller to prevent settings to be changed accidently, hold the
LEAF button for three or more seconds. While the display is locked, you will
not be able to switch modes or changes any settings. You will only be able to
put the controller in ECO display by pressing the LEAF button.
Holding the LEAF button for three or more seconds will unlock the controller.
TEMPERATURE ALARM ALERT
This icon will flash when the high or low temperature alarm that you have set
has been triggered.
HUMIDITY ALARM ALERT
This icon will flash when the high or low humidity alarm that you have set has
been triggered.
PROGRAMMING
-
MODE BUTTON
This button cycles through each of the controllers modes: ON,OFF TIMER AUTO (4 triggers), and ALARM (4 settings). -
UP/DOWN BUTTON
The up and down buttons adjusts the settings of the mode that you are in Up button increases and down but -
LEAF BUTTON
This turns the display off while programs run in the background. Hold for two seconds to lock or unlock the display. -
PROBE TEMP/HUMIDITY
Displays the current temperature/humidity that the corded sensor probe is measuring Shows “-“if no probe is plugged in. -
CONTROLLER MODE
This area displays the mode that the controller is currently in. Press the Mode Button to cycle through the modes. -
ALERT ICONS
This area displ ays the alerts and statuses from the controller including alarms and screen lock. -
FAN SPEED
Displays the current speed the fan is running at, or what speed it should be running at if no fans are plugged in. -
SETTING
Displays the value you have set for the current mode. Press the up or down button to change. -
FAHRENHEIT AND CELSIUS CONVERSION
Please set the controller to OFF Mode, then hold the UP BUTTON and DOWN BUTTON simultaneously for 3 seconds to switch displayed units between Fahrenheit (° F) and Celsius (°C). -
TEMPERATURE & HUMIDITY CALIBRATION
To adjust the temperature and humidity that the probe sensor is measuring, follow the steps below:
1)Set the controller to OFF Mode.
2)Hold the LEAF Button ( ) and MODE BUTTON ( ) simultaneously for 5 seconds to start temperature calibration. Perform this operation again to start humidity calibration.
3)When corresponding data flashes on the screen, press UP/DOWN BUTTON to calibrate the temperature/humidity.
4)To save the settings, hold the LEAF Button ( ) and MODE BUTTON ( ) simultaneously for 5 seconds once more. -
DISPLAY BRIGHTNESS
To adjust the brightness of the display, please set the controller to OFF Mode, then press the up or down button to increase or decrease the brightness level. Four brightness settings are available.
MODE SETTING
Press the Mode button to cycle through the controller’s available programming modes and settings: ON/ OFF Mode, TIMER Mode AUTO Mode (4 triggers), ALARM Settings (4 triggers).
TIMER MODE TIMER Mode, press the up or down
button to set a time for the timer. the fans will run at the speed set in ON
Mode until the timer’s clock runs out. in which the fans will stop running.
The clock will begin counting down if no buttons are pressed for 3 seconds.
Leaving the timer mode while the countdown is running will pause the clock
until you return to this mode.
ON/OFF MODE
ON Mode, the fans will run continuously regardless of temperature or
humidity, the speed set in this mode will be the max speed the fans can reach
in AUTO Mode.
OFF Mode, the fans will not run regardless of temperature or humidity.
While in this mode,pressing the up or down button will change the display’s
brightness.
There are four settings for brightness, (Setting: l/2/3/A3),On setting A3, if
the device is left unattended for 30 seconds, the display will automatically
dim its brightness back to setting 1.
Holding up and down button at the same time, will change the Fahrenheit (° F)
to Celsius (°C).