Schneider Electric RM17TG00 Harmony 3 Phase Control Relay Instruction Manual

June 16, 2024
Schneider Electric

Schneider Electric RM17TG00 Harmony 3 Phase Control Relay

Schneider Electric RM17TG00 Harmony 3 Phase Control
Relay

Introduction

This product must be installed, connected and used in compliance with prevailing standards and/or installation regulations.
As standards, specifications and designs develop from time to time, always ask for confirmation of the information given in this publication.

Product Feature

Product Feature Product Feature Product Feature Product Feature

  1. Relay output status (yellow) LED R/R1/R2
  2. 35mm rail clip-in spring
  3. Power supply status (green) LED. Un/Dial pointer
  4. Voltage range selection switch (RM22TR – with ON/OFF Delay selector)
  5. Time delay adjustment potentiometer. Tt/Tt1/Tt2
  6. Overvoltage threshold adjustment potentiometer. >U
  7. Undervoltage threshold adjustment potentiometer. <U
  8. Overvoltage & Undervoltage threshold adjustment potentiometer. ΔU
  9. Asymmetry threshold adjustment potentiometer. Asy/Asym
  10. Fault detection status (yellow) LED. Def
  11. Diagnostic button

For product comparison, refer to Harmony Control Relays Catalog or datasheet for more information.

Dimension

Dimension

Safety Information

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH

  • Disconnect all power before servicing equipment.
  • Confirm that the product power supply voltage and its tolerances are compatible with those of the network.

Failure to follow these instructions will result in death or serious injury.

WARNING

UNINTENDED EQUIPMENT OPERATION OR INADEQUATE OVERCURRENT PROTECTION

  • Do not use in safety critical system.
  • Do not disassemble, repair or modify the product.
  • Install the product in the operating environment conditions described in this document.
  • Install properly rated fuses as recommended in this document.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.

Mounting & Installation

Mounting & Installation

Recommended Distance

Mounting & Installation
Mounting & Installation

Connection Example

Connection Example Connection Example

  1. A fuse. UL…Class CC ; IEC…gG
    Connection Example

  2. Warning: Do not connect 3 phase control relay to monitor output of Variable Speed Drive (VSD).
    Connection Example

  3. Light indicator

Setting Example

Setting Example

R/R1/R2 Closed

R/R1/R2 Open

L1/L2/L3 is referring to line-line voltage except for RM35UB3N30

Example 1: To set 3 phase voltage monitoring at 220VAC L-L +/-12 %, Asymmetry monitoring 5 %, Fault delay = 5 s using RM17TE00

1| 2| 3| 4|
---|---|---|---|---
|

220V * 12% = 26.4V >U: 220V + 26.4 = 246.4V

|

Asy: 220V * 5% = 11V

| | Hysteresis (H): >U/

H = 2% V: 220V * 2% = 4.4V

Setting Example Setting Example

Example 2: To set 3 phase voltage monitoring at 415VAC L-L, >U at 18 %, <U at 16 %, On delay = 5 s using RM22TR33

1| 2| 3| 4|
---|---|---|---|---
|

415V * 18% = 74.7V

U: 415V + 74.7 = 489.7V

|

415V * 16% = 66.4V
<U: 415V – 66.4 = 348.6V

| | **Hysteresis (H):

U/<U*H = 2% V:
415V
2% = 8.3V

Setting Example Setting Example

Example 3: To set 3 phase voltage monitoring at 220VAC L-N,>U at 18 %, U Fault delay = 12 s, <U Fault delay = 9 s using RM35UB3N30

1| 2| 3| 4|
---|---|---|---|---
|

220V * 18% = 39.6V

U: 220V + 39.6 = 259.6V

|

220V * 16% = 35.2V
<U: 220V – 35.2V = 184.8V

| | **Hysteresis (H):

U/<U*H = 2%
V: 220V
2% = 4.4V

Setting ExampleSetting Example

Setting Change & Reset
If the voltage range selection switch position is changed while the device is operating, all the LEDs will blink, but the product continues to operate with the voltage selection preceding the change of position. The product has to be powered off and on again for the new selection to take effect. All LED’s return to their normal state if the switch is returned to the original position.

Function Diagram

R/R1/R2 Closed / R/R1/R2 Fermé / R/R1/R2 Geschlossen /

R/R1/R2 Open / R/R1/R2 Ouvert / R/R1/R2 Geöffnet /

Phase Loss & Phase Sequence

Phase Loss & Phase Sequence

Table 1

RM35UB3N30
RM35UB330
RM35TF30 150V
RM22TA33 30%Us/250V* (2)
RM22TA31 30%Us/150V* (2)
RM22TU23 250V
RM22TU21 150V
RM22TR33 250V
RM22TR31 150V
RM22TG20 100V
RM17UB310
RM17TE00 150V
RM17TA00 150V
RM17TU00 150V
RM17TT00 30%Us/150V* (2)
RM17TG20 100V
RM17TG00 100V

Phase Loss Threshold /

  1. Refer to Table 1 for phase loss threshold
  2. Phase loss threshold will follow whichever of higher value
  3. Refer to Table 2 for Response time (Tr). Time Delay (Tt) does not apply to phase loss or phase sequence.
    Voir le tableau 2 pour le temps de réponse (Tr). La temporisation (Tt) ne s’applique pas à la perte de phase ni

Undervoltage

Undervoltage

Overvoltage & Undervoltage

Overvoltage & Undervoltage

Overvoltage & Undervoltage

Overvoltage & Undervoltage

Asymmetry

Asymmetry

Table 2

| RM17TG00| RM17TG20| RM17TT00| RM17TU00| RM17TA00| RM17TE00| RM17UB310| RM22TG20| RM22TR31| RM22TR33| RM22TU21| RM22TU23| RM22TA31| RM22TA33| RM35TF30| RM35UB330| RM35UB3N30
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Response Time (Tr)| <300ms
ON/OFF Delay (Tt/Tt1/Tt2)| | | | 0.1…10s| 0.1…10s| 0.1…10s| 0.3…30s| | 0.1…30s| 0.1…30s| | | 0.1…30s| 0.1…30s| 0.1…10s| 0.3…30s| 0.3…30s
Hysteresis (H)| 2% V

Refer to Table 2 for Response time (Tr). Time Delay (Tt) does not apply to phase loss or phase sequence.
Response Time (Tr) not shown together with Time Delay (Tt).

LED Indication

  • Off
  • On
  • Slow Blink
  • Fast Blink

Phase Loss & Phase sequence

  1. Only RM22TG20 has 2 relay outputs / 2 sorties relais pour RM22TG20 uniquement
    Phase Loss & Phase Sequence
    Except RM22TG20
    Phase Loss & Phase Sequence

Undervoltage ( <U) 

Phase Loss & Phase Sequence
Phase Loss & Phase Sequence

Overvoltage & Undervoltage (>U & <U)

Phase Loss & Phase Sequence
Phase Loss & Phase Sequence

Overvoltage & Undervoltage (>U & <U)

Phase Loss & Phase Sequence

Absence of Neutral/Phase (N?/N)

Phase Loss & Phase Sequence

Asymmetry

Phase Loss & Phase Sequence
Phase Loss & Phase Sequence

Time delay in progress

Diagnostic

For RM22 only (Except RM22TG20)

Power Supply| Input monitoring condition| Diagnostic Button| Output Relays Status
---|---|---|---
| | |
| |
| |
| | |

Time delay in progress