Truma Aventa RV Easy Start Instructions

June 16, 2024
Truma

Truma Aventa RV Easy Start

Product Information

The Truma Aventa RV Easy Start Wiring is a wiring system designed for use with the Truma Aventa RV air conditioning unit. It allows for easy installation and integration of the Easy Start feature, which enhances the performance and efficiency of the air conditioning unit.

Specifications

  • Compressor RD (red) wire
  • Easy Start Black wire
  • Easy Start Orange wire
  • WH (white) Herm (S) wire
  • Compressor run BU (blue) (R) wire
  • Easy Start Brown wire
  • Easy Start White wire

Product Usage Instructions

  1. Step 1: Make a 3-way splice
    Take the compressor RD (red) wire and the Easy Start Black wire. Make a 3-way splice by connecting these two wires together.

  2. Step 2: Install the Easy Start Orange wire
    Locate the run capacitor next to the WH (white) Herm (S) wire. Install the Easy Start Orange wire onto the run capacitor, connecting it to the WH wire.

  3. Step 3: Remove and splice wires
    Remove the compressor run BU (blue) (R) wire from the run capacitor. Splice this wire with the Easy Start Brown wire.

  4. Step 4: Connect the Easy Start White wire
    In the same location where you removed the BU wire in step 3, connect the Easy Start White wire.

FAQ

  • Q: What is the purpose of the Easy Start feature?
    A: The Easy Start feature enhances the performance and efficiency of the Truma Aventa RV air conditioning unit by providing a smooth and controlled start-up.

  • Q: Can I install the Truma Aventa RV Easy Start Wiring myself?
    A: Yes, the installation process is designed to be user-friendly. However, if you are unsure or uncomfortable with electrical work, it is recommended to seek professional assistance.

Truma Aventa RV Easy Start Wiring

  1. Make a 3-way splice with the compressor RD (red) (C) wire & the Easy Start Black wire
  2. Install the Easy Start Orange wire on the run capacitor next to the WH (white) Herm (S) wire
  3. Remove the compressor run BU (blue) (R) wire from the run capacitor & splice with the Easy Start Brown wire
  4. Where you just removed the BU wire in step 3, connect the Easy Start White wire