U-LINE UMCR014-D01A Ice Makers Refrigeration Appliances User Guide

June 16, 2024
U-Line

UMCR014-D01A Ice Makers Refrigeration Appliances

Product Information

Specifications

  • Model: UMCR014-SD01A
  • Designed, engineered, and assembled in WI, USA
  • Contains R600a (Isobutane) refrigerant
  • California Proposition 65 warning: This product contains
    chemicals known to the state of California to cause cancer and
    birth defects or other reproductive harm.

Safety and Warning

Please read all instructions before installing, operating, or
servicing the appliance. Use this appliance for its intended
purpose only and follow these general precautions with those listed
throughout this guide:

Safety Alert Definitions

Throughout this guide are safety items labeled with a Danger,
Warning, or Caution based on the risk type:

  • DANGER: Danger means that failure to follow
    this safety statement will result in severe personal injury or
    death.

  • WARNING: Warning means that failure to follow
    this safety statement could result in serious personal injury or
    death.

  • CAUTION: Caution means that failure to follow
    this safety statement may result in minor or moderate personal
    injury, property, or equipment damage.

DANGER:

  • This unit contains R600a (Isobutane) which is a flammable
    hydrocarbon. It is safe for regular use.

  • Do not use sharp objects to expedite defrosting.

  • Do not service without consulting the R600a specifications
    section included in the User Guide.

  • Do not damage the refrigerant circuit.

WARNING:

  • Service must be done by factory authorized service
    personnel.

  • Any parts shall be replaced with like components.

  • Failure to comply could increase the risk of possible ignition
    due to incorrect parts or improper service.

CALIFORNIA PROPOSITION 65: This product
contains chemicals known to the state of California to cause cancer
and birth defects or other reproductive harm. www.P65warnings.CA.gov

Installation

Before installing the product, ensure that you meet the
following requirements:

Environmental Requirements

  • Place the product in a well-ventilated area with sufficient
    clearance around it.

  • Avoid exposing the product to extreme temperatures or direct
    sunlight.

  • Keep the product away from sources of heat, such as radiators
    or ovens.

Electrical Cutout & Product Dimensions

  • Ensure that you have a suitable electrical cutout for the
    product.

  • Refer to the product dimensions in the User Guide to determine
    the required space for installation.

Water Hookup

If your product requires a water hookup, follow these steps:

  1. Locate the water hookup connection on the product.
  2. Connect a water supply line to the hookup connection.
  3. Tighten the connection securely.

General Installation

Follow these steps to install the product:

  1. Choose a suitable location for the product.

  2. Ensure that the product is level by adjusting the leveling
    feet.

  3. Securely attach the product to the surrounding area or cabinet
    to prevent movement.

Grille Installation

If your product includes a grille, follow these steps to install
it:

  1. Align the grille with the designated slots on the product.
  2. Slide the grille into place until it locks securely.

Door Swing

If you need to change the door swing direction, follow these
steps:

  1. Refer to the User Guide for specific instructions on changing
    the door swing direction.

  2. Follow the provided steps carefully to avoid damaging the
    product.

Door Adjust

If the door alignment needs adjustment, follow these steps:

  1. Refer to the User Guide for specific instructions on adjusting
    the door alignment.

  2. Follow the provided steps carefully to ensure proper door
    sealing and operation.

Maintenance

Door Latch Cleaning

To clean the door latch, follow these steps:

  1. Disconnect the product from the power source.

  2. Use a mild detergent and a soft cloth to clean the door
    latch.

  3. Rinse with clean water and dry thoroughly.

Cleaning Condenser

To clean the condenser, follow these steps:

  1. Disconnect the product from the power source.

  2. Remove any dust or debris from the condenser using a soft brush
    or vacuum cleaner.

  3. Ensure that the condenser fins are clean and free from
    obstruction.

Extended Non-Use

If the product will not be used for an extended period, follow
these steps:

  1. Disconnect the product from the power source.
  2. Remove all items from the product.
  3. Clean the interior and exterior of the product.
  4. Leave the door slightly ajar to allow for air circulation and
    prevent odors.

Operating Instructions

First Use

Before using the product for the first time, follow these
steps:

  1. Ensure that the product is properly installed and connected to
    a power source.

  2. Clean the interior of the product with a mild detergent and
    water.

  3. Rinse with clean water and dry thoroughly.

Ice

To make ice using the product, follow these steps:

  1. Ensure that the water hookup is connected and the water supply
    is turned on.

  2. Select the desired ice size or mode on the product’s control
    panel.

  3. Wait for the ice to be produced and collected in the ice
    bin.

Airflow and Product Loading

To ensure proper airflow and maximize product loading, follow
these guidelines:

  • Do not block the airflow vents inside the product.

  • Allow sufficient space between items to ensure proper air
    circulation.

  • Do not overload the product beyond its recommended
    capacity.

Troubleshooting

If you encounter any issues with the product, refer to the
Troubleshooting section in the User Guide for possible
solutions.

FAQ

Q: Where can I find additional information on my
product?

A: User Guides, Spec Sheets, CAD Drawings, and Product Warranty
information are available digitally on u-line.com.

Q: What should I do if I suspect property damage or
personal injury related to the product?

A: In the unlikely event of property damage or personal injury,
please follow these steps:

  1. Contact U-Line Customer Care immediately at
    +1.414.354.0300.

  2. Do not attempt service or repairs without prior written
    approval from U-Line. Claims will not be eligible if the unit has
    been altered or repaired in the field without approval.

Q: How can I contact U-Line for general
inquiries?

A: You can contact U-Line Corporation at the following address
and contact details:
U-Line Corporation
8900 N. 55th Street
Milwaukee, Wisconsin 53223
USA
Monday – Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
Email: sales@u-line.com
Website: u-line.com

Q: How can I get service and parts
assistance?

A: For service and parts assistance, contact U-Line at the
following details:
Monday – Friday 8:00 am to 4:30 pm CST
Service Email: onlineservice@u-line.com
Parts Email: onlineparts@u-line.com

USER GUIDE & SERVICE MANUAL
Model: UMCR014-SD01A

USER GUIDE & SERVICE MANUAL

Click on any section below to jump directly there

Table of Contents
Intro
Safety Safety and Warning Disposal And Recycling
Installation Environmental Requirements Electrical Cutout & Product Dimensions Water Hookup General Installation Grille Installation Door Swing Door Adjust

Warranty Claims Parts Ordering Replacement Parts R600a Specifications System Diagnosis Guide Compressor Specifications Troubleshooting Extended Defrost Replace Ice Maker Warranty

Maintenance Door Latch Cleaning Cleaning Condenser Extended Non-Use

Operating Instructions First Use Ice Airflow and Product Loading

Service Troubleshooting Wire Diagram Product Liability

USER GUIDE
WELCOME TO U-LINE Congratulations on your U-Line purchase! Your product comes from a company with decades of premium modular ice making, refrigeration, and wine preservation experience. U-Line creates products focused on functionality, style, and inspired innovations — paying close attention to even the smallest details. Applications include residential, outdoor, ADA height compliant, marine, and commercial. Product categories include Beverage Centers, Wine Refrigerators, Ice Machines, Refrigerators, Freezers, and Dispensers. Our advanced refrigeration systems, large and flexible capacities, and clean integrated look are what makes our products Built-In to Stand Out®. Since 2014, U-Line has been part of the Middleby family of brands. Products are designed, engineered, and assembled in Milwaukee, Wisconsin, USA, and select products are available worldwide.
U-Line — RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE.®
PRODUCT INFORMATION Looking for additional information on your product? User Guides, Spec Sheets, CAD Drawings, and Product Warranty information are available digitally on u-line.com.
PROPERTY DAMAGE / INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following steps: 1. U-Line Customer Care must be contacted immediately at +1.414.354.0300. 2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.

GENERAL INQUIRIES U-Line Corporation 8900 N. 55th Street Milwaukee, Wisconsin 53223 USA Monday – Friday 8:00 am to 4:30 pm CST T: +1.414.354.0300 Email: sales@u-line.com u-line.com
CONNECT WITH US

SERVICE & PARTS ASSISTANCE Monday – Friday 8:00 am to 4:30 pm CST T: +1.414.354.0300 Service Email: onlineservice@u-line.com Parts Email: onlineparts@u-line.com
Designed, engineered and assembled in WI, USA

Introduction

3

USER GUIDE
Safety and Warning
NOTICE Please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a Danger, Warning, or Caution based on the risk type:
! DANGER
Danger means that failure to follow this safety statement will result in severe personal injury or death.
! WARNING
Warning means that failure to follow this safety statement could result in serious personal injury or death.
! CAUTION
Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property, or equipment damage.

! DANGER
This unit contains R600a (Isobutane) which is a flammable hydrocarbon. It is safe for regular use. Do not use sharp objects to expedite defrosting. Do not service without consulting the “R600a specifications” section included in the User Guide. Do not damage the refrigerant circuit.
! WARNING
Service must be done by factory authorized service personnel. Any parts shall be replaced with like components. Failure to comply could increase the risk of possible ignition due to incorrect parts or improper service.
CALIFORNIA PROPOSITION 65 This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. www.P65warnings.CA.gov
! CAUTION
This equipment is to be installed with adequate backflow protection to comply with applicable federal, state and local codes.

Safety and Warning

4

USER GUIDE
Disposal and Recycling ! DANGER
RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside.
If the unit is being removed from service for disposal, check and obey all federal, state, and local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely:
1. Remove all consumable contents from the unit.
2. Unplug the electrical cord from its socket.
3. Remove the door(s)/drawer(s).

Disposal and Recycling

5

USER GUIDE
Environmental Requirements
This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements.
This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models.
For best performance, keep the unit out of direct sunlight and away from heat generating equipment.
In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal. The condensation will evaporate when the humidity drops.
! CAUTION
Damages caused by ambient temperatures of 40°F (4°C) or below are not covered by the warranty.

Environmental Requirements

6

USER GUIDE
Electrical
! WARNING
SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.
Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
Altering, cutting or removing power cord, removing power plug, or direct wiring can cause serious injury, fire, loss of property and/or life, and will void the warranty.
Never use an extension cord to connect power to the unit.
Always keep your working area dry.
NOTICE Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three-prong), polarized receptacle that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. A GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because it could be prone to nuisance tripping. However, be sure to consult your local codes.
See CUTOUT & PRODUCT DIMENSIONS for recommended receptacle location.

Electrical

7

USER GUIDE
Cutout & Product Dimensions
PREPARE SITE Your U-Line product has been designed for either freestanding or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed, and clearance is required for an electrical connection in the rear.
! CAUTION
Unit can NOT be installed behind a closed cabinet door.

FRONT

14 / ” (370 mm
4 /” (119 mm
Flange
/”
(19 mm

25 / ” (640 mm

8 /” (222 mm

CUTOUT DIMENSIONS
Filler Panel (Not Provided by U-Line) ­ Needed to Attach Mounting Flange on Unit

Cutout Height 25-1/8″ (638 mm)

3/4″ (19 mm) Minimum
Flange Mounting Area
Preferred location for water line and electrical outlet is in adjacent cabinet.

18-1/2″ (470 mm) Minimum

7″ (178 mm)
4″ (102 mm)

3/4″ (19 mm)
Minimum Flange
Mounting Area

14-11/16″ (373 mm)
Cutout Width

PRODUCT DIMENSIONS

REAR

3/4″ Toe Kick
(19 mm)
Minimum Flange
Mounting Area

TOP SIDE

14 / ” (367 mm

/” (19mm

Flange
12 / ” (391 mm

17 / ” (449 mm

17″ (433 mm

14 / ” (365 mm

1 /” (32 mm

2 /” (73 mm
Water Line

Power Cord 4″

3 /”

(102 mm

(95 mm

Cutout & Product Dimensions

8

2 /” (60 mm

USER GUIDE

Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4″ (6.35 mm) compression fitting. U-Line recommends using accessory water hook up kit ­ part # ULAWATERHOOKUP. The kit includes a 10′ (3 m) braided flexible water supply line and a brass hose fitting.
! CAUTION
Plumbing installation must observe all state and local codes. All water and drain connections MUST BE made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm.
Water Supply Connection When connecting the water supply, please note the following: · Before installing the unit and connecting to the cold
water supply, review the local plumbing codes. · The water pressure should be between a minimum of
20 and a maximum of 120 psi (138 and 827 kPa). · The water line MUST have a shut-off valve in the
supply line. · The water line should be looped into 2 coils. This
will allow the unit to be removed for cleaning and servicing. Make certain that the tubing is not pinched or damaged during installation.
! WARNING
Connect to potable water supply only.
! CAUTION
Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home.
Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber gasket. The gasket provides an adequate seal ­ other materials could cause blockage of the valve.
Water Hookup

Failure to follow recommendations and instructions may result in damage and/or harm, flooding or void the product warranty. Use new hose set. Do not reuse old hose set.
! CAUTION
Turn off water supply and disconnect electrical supply to unit prior to installation. Use caution when handling back panel. The edges could be sharp. Turn off water supply and disconnect electrical supply to product prior to attempting installation. 1. Remove the back panel.
2. Locate water valve inlet and connect to valve.

3. Break away filler feature in bushing with flat screwdriver.

4. Thread water line through back panel hole (with bushing).

Note: Orientation of hole

and location of water line clamp may be different depending on model.

Remove with flat screwdriver

5. Turn on water supply and check for leaks.
6. Reinstall back panel.
7. Loosen screw on clamp, thread water line through water line clamp, tighten screw.
9

Water line Clamp

USER GUIDE
General Installation
LEVELING INFORMATION NOTICE Because these units do not have leveling legs, it is extremely important that they sit on a level surface. If they are not level, the ice mold will not fill evenly. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown.
INSTALLATION 1. Plug in the power/electrical cord. 2. Gently push the unit into position. Be careful not to
entangle the cord or water line. 3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. 4. Remove interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.

General Installation

10

USER GUIDE
Grille Installation
REMOVING AND INSTALLING GRILLE
! WARNING
Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed.
! WARNING
DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged. Removing the grille 1. Disconnect power to the unit. 2. Open unit door. 3. Remove the center screw. 4. Remove grille by sliding grille up and pulling it toward
you.
3

Installing the grille 1. Open unit door. 2. Align grille with front of unit slide front tab on grille
behind front of base. 3. Install center screw. 4. Reconnect power to the unit.

Grille Installation

11

USER GUIDE
Door Swing
Wall 2-1/8″ Min.
(54 mm)
90° Door Swing
Stainless Steel, Black and White
This unit requires zero clearance for the door to open 90o when installed adjacent to cabinets. If installing the unit next to a wall, the door handle requires 2-1/8″ (54mm) clearance.

Door Swing

12

USER GUIDE

Door Adjustments
DOOR ALIGNMENT AND ADJUSTMENT

Align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool properly, or excessive frost may form in the interior.
NOTICE

Properly aligned, the door’s gasket should be firmly in contact with the cabinet all the way around the door (no gaps). Carefully examine the door’s gasket to ensure that it is firmly in contact with the cabinet. Also make sure the door gasket is not pinched on the hinge side of the door.
To align and adjust the door:

1. Loosen (do not remove) top and bottom hinge screws using a Torx T-25 screwdriver on the top and a 1/4″ socket on the bottom.

2. Align door squarely with cabinet.
3. Make sure gasket is firmly in contact with cabinet all the way around the door (no gaps).

4. Tighten bottom hinge screws.

5. Tighten top hinge screws. REVERSING THE DOOR Location of the unit may make it desirable to mount the door on the opposite side of the cabinet.

The hinge hardware will be removed and reinstalled on the opposite side of the cabinet. Remove door latch assembly

Remove door latch assembly and reinstall on opposite side of door (see DOOR LATCH). TO REVERSE THE DOOR Remove top hinge and door:

1. Hold door to keep it

from falling.

Hinge screws

2. Remove top hinge from cabinet using a Torx T-25 screwdriver to remove three screws.

Door Adjustments

3. Remove door by tilting forward and lifting door off bottom hinge. Retain shoulder washers; they will be reused.
4. Remove three screws from hinge holes on the opposite side.
5. Install three screws into holes where the hinge was removed.
Move bottom hinge:
1. Remove bottom hinge from cabinet using a 1/4″ socket.
Note: If unit is equipped with a plastic grille, remove the top center screw and the bottom screw on the hinge first. Remove grille and other hinge screw, and proceed to Step 2.

Center Screw

Remove two hinge screws

2. Remove corresponding screws on opposite side of cabinet.
3. Install bottom hinge on opposite side. Prepare door: 1. Take out the two screws holding the stainless handle.
Remove handle and reinstall the screws into the holes.
2. On the opposite side of the door, remove the two handle screws and use them to install handle.

13

USER GUIDE

3. Remove plastic plug on top of door and save for reinstallation on opposite side.
4. Relocate plastic bushings on top and bottom of door to opposite side. Clean out bushing hole in door bottom with a screwdriver if necessary.
Hinge

Plastic Hole Plug

Plastic Hole Plug

Screw
Right Side Door Swing
Right Side Invert Hinge Screw

Invert Hinge

Left Side Door Swing

Install top hinge: 1. Remove pivot screw from top hinge, invert screw and
reinstall pivot screw in top hinge.
2. Lift the door onto the bottom hinge.
3. Align edge of the hinge with the outer edge of the unit.
4. Tighten three screws.
5. Insert plastic plug in opposite end of door.

Install grille if applicable.

Align and adjust the door:
Align and adjust the door (see DOOR ALIGNMENT AND ADJUSTMENT)

Door Adjustments

14

USER GUIDE
Door Latch
The door latch assembly included with your unit can be installed to prevent the door from opening when the vehicle is in motion. To install, perform the following: 1. Remove the two outer most screws from the non-
hinge side. 2. Place spacer (2) over mounting holes. Place latch (1)
on top of spacer (2). Note: Spacer (2) only required if included with unit. 3. Re-install the screws, but do not tighten all the way. 4. Verify door latch engagement and adjust as necessary. 5. Tighten screws.
1 2
Door latch can be used to prop door open approximately 1/2″ (13 mm) when unit is not in use.

Door Latch

15

USER GUIDE
First Use
Initial startup requires no adjustments.
NOTICE U-Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line. To turn the unit on or off:
Press the rocker switch located inside the door on the front panel, or behind the grille.

OFF ON

First Use

16

USER GUIDE

Ice
ICE MAKER OPERATION When the ice bucket is full, the ice making mechanism will shut off. However, the refrigeration system will continue to cool and maintain the ice supply.
NOTICE Do not place cans or bottles in the ice compartment because they will freeze.
OFF
ON
To turn off ice production: Raise the bin arm into an upright and locked position. The unit will preserve temperature for ice storage.

! CAUTION
NEVER use an ice pick, knife or other sharp instrument to separate cubes. Shake the ice bucket instead.
During periods of limited use or high ambient temperatures, it is common for cubes to fuse together. Gently shake the bucket to break apart cubes. If not using the ice maker regularly, empty the ice bucket periodically to ensure fresh cubes.
It is normal for cubes to appear cloudy. The cause is air trapped in the water because of fast freezing. It is not caused by the health, taste or chemical make up of the water. It is the same air that is in every glass of water you drink.
Remove the ice bucket for emptying and cleaning. To remove the ice bucket, raise the bin arm and remove the bucket from the ice compartment. Use the ice bucket for ice storage only.

NOTICE If not intending to use the ice maker, turn the water supply valve off. It is also important to raise the bin arm of the ice maker (see above). Failure to raise the bin arm may result in damage to the water valve.
Certain sounds are normal during the unit’s operation. You may hear the compressor or fan motor, the water valve, or ice dropping into the ice bucket.

Ice

17

USER GUIDE
ICE MAKER ADJUSTMENT Ice Cube Thickness Adjustment Interval – As Required On ice maker equipped models, adjust the cube size by changing water amount injected into the ice maker assembly as follows:
1

3. Turn the adjusting screw toward the minus (-) sign (clockwise) for smaller cubes or toward the plus (+) sign (counterclockwise) for larger cubes.
4. Install the ice maker assembly cover.
ADJUSTING ICE HARVEST 1. Remove the front grille (see GRILLE INSTALLATION). 2. Using a flat tip screwdriver, turn the adjusting screw
(3) a small increment clockwise for a COLDER setting (slower ice production) or counterclockwise for a WARMER setting (faster ice production).

2
1. Remove the ice maker assembly cover (1). 2. Find the adjusting screw on the ice maker assembly
control box (2). The adjusting screw is just below the minus (-) and plus (+) signs on the control box.
! CAUTION
Too large of an adjustment to the screw can cause the water to overflow the ice maker and can cause property damage.

1

2

C

OLDER 3

Warmer Colder
3. Reinstall the front grille (two screws).

Ice

18

USER GUIDE
Airflow and Product Loading
NOTICE The unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit will not perform as expected. Do not install the unit behind a door.
Depending on the model, your grille may not match exactly with the below illustrations.

Airflow and Product Loading

19

USER GUIDE
Cleaning
EXTERIOR CLEANING Vinyl Clad (Black or White) Models Clean surfaces with a mild detergent and warm water solution. Do not use solvent-based or abrasive cleaners. Use a soft sponge and rinse with clean water. Wipe with a soft, clean towel to prevent water spotting.
Clean any glass surfaces with a non-chlorine glass cleaner.
Stainless Models Stainless door panels, handles and frames can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach.
Keep your stainless unit looking new by cleaning with a good quality all-in- one stainless steel cleaner and polish monthly. For best results use Claire® Stainless Steel Polish and Cleaner. Comparable products are acceptable. Frequent cleaning will remove surface contamination that could lead to rust. Some installations may require cleaning weekly.
Do not clean with steel wool pads.
Do not use stainless steel cleaners or polishes on any glass surfaces.
Clean any glass surfaces with a non-chlorine glass cleaner.
Do not use cleaners not specifically intended for stainless steel on stainless surfaces (this includes glass, tile and counter cleaners).

If any surface discoloring or rusting appears, clean it quickly with Bon-Ami® or Barkeepers Friend Cleanser® and a nonabrasive cloth. Always clean with the grain. Always finish with Claire® Stainless Steel Polish and Cleaner or comparable product to prevent further problems.
Using abrasive pads such as ScotchBriteTM will cause the graining in the stainless to become blurred.
Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible.
Integrated Models To clean integrated panels, use household cleaner per the cabinet manufacturer’s recommendations.
INTERIOR CLEANING Disconnect power to the unit.
Clean the interior and all removed components using a mild nonabrasive detergent and warm water solution applied with a soft sponge or non-abrasive cloth.
Rinse the interior using a soft sponge and clean water.
Do not use any solvent-based or abrasive cleaners. These types of cleaners may transfer taste to the interior products and damage or discolor the interior.

Cleaning

20

USER GUIDE

DEFROSTING Manual Defrost Models This unit is a manual defrost model and will require occasional defrosting. When there is build-up of 1/4″ (6 mm) or more of frost, manually defrost the unit.
! CAUTION
DO NOT use an ice pick or other sharp instrument to help speed up defrosting. These instruments can puncture the inner lining or damage the cooling unit. DO NOT use any type of heater to defrost. Using a heater to speed up defrosting can cause personal injury and damage to the inner lining.
To defrost: 1. Disconnect power to the unit.
2. Remove ice bucket and discard ice.
3. Place towel or other absorbent material on bottom of ice bin.
4. Fill the ice bucket half full with warm, not hot water. This will help the unit defrost faster.
5. Place the ice bucket back into the unit on top of the towel or other absorbent material.
6. Prop the door in an open position (2 in. [50 mm] minimum).
7. After about 1 hour remove the ice bin and discard water.
8. Allow the frost to melt naturally.
9. After the frost melts completely clean the interior and all removed components. (See INTERIOR CLEANING).

NOTICE DO NOT clean ice bucket using a dishwasher. The bucket is not dishwasher safe and will be damaged.
10.When the interior is dry, reconnect power and turn unit on.
NOTE: To safeguard against contaminates in ice, discard first three batches of ice after defrosting.

Cleaning

21

USER GUIDE
Cleaning Condenser
INTERVAL – EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary.
! WARNING
Disconnect electric power to the unit before cleaning the condenser. NOTICE DO NOT use any type of cleaner on the condenser unit. Condenser may be cleaned using a vacuum, soft brush, or compressed air.
1. Remove the grille. See GRILLE INSTALLATION). 2. Clean the condenser coil using a soft brush or vacuum
cleaner. 3. Install the grille.
CONDENSER

Cleaning Condenser

22

USER GUIDE
Extended Non-Use
VACATION/HOLIDAY, PROLONGED SHUTDOWN The following steps are recommended for periods of extended non-use:
1. Remove all consumable content from the unit.
2. Disconnect the power cord from its outlet/socket and leave it disconnected until the unit is returned to service.
3. Turn off the water supply.
4. If ice is on the evaporator, allow ice to thaw naturally.
5. Clean and dry the interior of the cabinet. Ensure all water has been removed from the unit.
6. Disconnect the water and drain line (if applicable) making sure all water is removed from the lines.
7. The door must remain open to prevent formation of mold and mildew. Open door a minimum of 2″ (50 mm) to provide the necessary ventilation.
WINTERIZATION If the unit will be exposed to temperatures of 40°F (5° C) or less, the steps above must be followed. In addition, drain pumps in clear ice machines must be drained according to the following procedure:
1. Remove the drain pump from the ice machine.
2. Drain the water in the pump’s reservoir by turning the pump upside down and allowing the water to drain through the pump’s inlet and vent tube fittings.
3. After water is drained, reinstall the drain pump and reattach all connections.

For questions regarding winterization, please call U-Line at 414.354.0300.
! CAUTION
Damage caused by freezing temperatures is not covered by the warranty.
Do not put anti-freeze in your unit.

Extended Non-Use

23

USER GUIDE

Troubleshooting
BEFORE CALLING FOR SERVICE If you think your U-Line product is malfunctioning, read the CONTROL OPERATION section to clearly understand the function of the control. If the problem persists, read the NORMAL OPERATING SOUNDS and TROUBLESHOOTING GUIDE sections below to help you quickly identify common problems and possible causes and remedies. Most often, this will resolve the problem without the need to call for service.
If your product needs service, please go to www.u-line.com/servicers/ and navigate to the Find a Servicer page to locate a U-Line Authorized servicer. Please make sure to register it at www.U-Line.com/u-lineregistration. If you have any issues following this process you can contact the U-Line Corporation by phone at +1.414.354.0300; please make sure you have your product Model and Serial Numbers handy; They can can be found on the Serial number plate located within the interior of your product, most often placed on the ceiling.
NORMAL OPERATING SOUNDS
All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components. Despite this technology, your model may make sounds that are unfamiliar.
Normal operating sounds may be more noticeable because of the unit’s environment. Hard surfaces such as cabinets, wood, vinyl or tiled floors and paneled walls have a tendency to reflect normal appliance operating noises.
Listed below are common refrigeration components with a brief description of the normal operating sounds they make. NOTE: Your product may not contain all the components listed.
· Compressor: The compressor makes a hum or pulsing sound that may be heard when it operates.
Troubleshooting

· Evaporator: Refrigerant flowing through an evaporator may sound like boiling liquid.
· Condenser Fan: Air moving through a condenser may be heard.
· Running Water: As your unit continues to produce ice you will hear water flowing into the collection chambers and running through the evaporator.

TROUBLESHOOTING GUIDE
! DANGER
ELECTROCUTION HAZARD. Never attempt to repair or perform maintenance on the unit before disconnecting the main electrical power.

Troubleshooting – What to check when problems occur:

Problem Unit Does Not Operate.
Light Remains on When Door is Closed Unit Develops Condensation on External Surfaces. Poor Ice Quality. No Ice Production.
Not Enough Ice.
Water in Ice Bin.

Possible Cause and Remedy
No electrical supply. Plug unit in or check circuit breaker.
Turn off light switch if equipped. Check reed switch.
The unit may be exposed to excessive humidity. Moisture will dissipate as humidity levels decrease.
Ice maker system may be dirty. Clean the ice maker.
Ensure water is being supplied to the unit. Verify the bin arm on the ice making device is not locked in the up position. If it is, gently push the bin arm down. See Ice Maker Production in the ICE section of this manual.
Ensure the condenser coil is clean and free of any dirt or lint build-up. Check ICE section of this manual for more information. Ensure unit is not located in excessive ambient temperatures or in direct sunlight. Ensure the door is closing and sealing properly. Ensure nothing is blocking the front grille, found at the bottom of the unit. Ensure the condenser coil is clean and free of any dirt or lint build-up.

24

USER GUIDE
Wire Diagram

Wire Diagram 1

42312_C WIRING DIAGRAM

SEE COMPRESSOR DIAGRAMS

MANUAL CONTROL ICEMAKER & COMBO

EMU ONLY

OVERLOAD
BLACK (BROWN) NEUTRAL WHITE (DARK BLUE)
RELAY

BLACK OR BLUE
CAP

BLACK (BROWN) BI1215 ONLY
OR ALL OTHER MODELS
LIGHT BLUE

ROCKER SWITCH

COND FAN

CONTROL

BLUE
(LIGHT BLUE)

YELLOW

4

RED 1
WHITE (DARK BLUE) 5
BROWN (ORANGE) 3

BLACK(BROWN) 2

BROWN

6

(ORANGE)

WATER VALVE

14 36

GROUND:

EMBRACO

GREEN or

GREEN W/ YELLOW COMPRESSOR

ICEMAKER RED

4 YELLOW

1 RED

5 WHITE 3 BROWN 2 BLACK
6 BROWN W/YELLOW

OROARNGBLEUENO

C
SWHOLD

YELLOW

NC

NO NC
BIN SW
C

BROWN

NC NO

WATER

CAM

SW

C

3 RPM MOTOR

MOLD HEATER

BLACK

LIMIT

SW

BROWN

220-240 VOLT PLUG

BLACK (BROWN) WHITE (DARK BLUE) WHITE
(DARK BLUE)

25

GROUND:

BLACK

GREEN or GREEN W/ YELLOW (BROWN)

BLACK-NEUTRAL (RIBBED)
BLACK-HOT (SMOOTH)

115 VOLT PLUG

WHITE (DARK BLUE)
POWER CORD ASSEMBLY

USER GUIDE
Product Liability
Field service technicians are authorized to make an initial assessment in the event of reported damages. If there are any questions about the process involved, the technician should call U-Line for further explanation.
While inspecting for defects or installation issues, photos should be taken to document any damages or issues found.
During the assessment, if the service technician is able to find the source of the damage and it can be resolved by replacement of a part, the servicer is authorized to replace the part in question. The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
If the service technician determines the damage is the result of installation issues (water connection/drain, etc.), the consumer would be notified and the issues shall be resolved at the direction of the consumer.
If damage is evident and the service technician is unable to find the source, U-Line must be contacted at +1.414.354.0300 for further direction.
8900 N. 55th Street · Milwaukee, WI 53223 T: +1.414.354.0300 · F: +1.414.354.5696
Website: www.u-line.com
Right product. Right place. Right temperature Since 1962.

Product Liability

26

USER GUIDE

Warranty Claims
The following information defines the parameters for filing a warranty claim:
· Valid serial number needed · Valid model number needed · Claims must be submitted online at
www.ULineService.com
· 60 day submittal deadline from date of completed service
· Only one repair or unit per warranty claim · Part order numbers will be required when submitting
for warranty labor

Units must be registered prior to warranty submittal. Customers may register at www.ULine.com. A proof of purchase is required. We also accept the following information to update warranty:
· New construction occupancy documents
· Closing paperwork
· Final billing – Remodel
Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.

22 14862 05 0527

Year Factory Month Factory

use Only

use Only

Warranty Claims

27

USER GUIDE

Parts

1

23

12

10 16
15

13
4 5
3

14

7 8 22

Item

UMCR014-SD01A
Description

1 BACK PANEL

2 COMPRESSOR EM2C46CLC,115V,R600

3 CONDENSER ASSEMBLY

4 CONDENSER FAN BLADE

5 CONDENSER FAN ASSEMBLY

6 CONTROL ASSEMBLY, MCR014 *

7 DOOR ASSEMBLY, UMCR014, SS

8 DOOR GASKET, 14″

9 DRIER

10 FACEPLATE 115V

11 FEET (4)

12 FLANGE ASSEMBLY, SS, FD

13 GRILLE W/SCREWS

14 HINGES W/SCREWS

15 ICE BUCKET

16 ICEMAKER, 115V, R600, MANUAL

17 PACKAGING *

18 POWER CORD, EXTERNAL *

19 WIRE HARNESS, MAIN *

20 WIRE ASSEMBLY, CONTROL *

21 ROCKER SWITCH

21

22 TRAVEL HANDLE W/SCREWS

23 TRAVEL LATCH ASSEMBLY

24 WATER LINE ASSEMBLY

25 WATER VALVE ASSEMBLY

  • NOT PICTURED 2

9

U-Line P/N 80-54632-00 80-55658-11 80-54601-00 80-54379-00 80-54378-00 80-55673-01 80-55673-00 80-55673-02 80-54055-00 80-54523-00 80-54529-00 80-54661-00 80-54657-00 80-54574-00 80-54611-00 80-55669-00 80-54612-00 80-55519-00 80-55638-12 80-55638-11 80-55603-00 80-54607-00 80-54572-00 80-54613-00 80-54356-00

24 25 11

Parts

28

USER GUIDE
Ordering Replacement Parts
Parts may be ordered online at www.U-Line.com
See our contact information below:
www.U-LineService.com (with service login) Phone Number: +1.414.354.0300
NOTICE Use only genuine U-Line replacement parts. The use of non-U-Line parts can reduce speed of ice production, cause water to overflow from ice maker mold, damage the unit, and void the warranty.
Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
If U-Line requires the return of original parts, we will inform you when the parts order is taken. This requirement will be noted on your packing list. A prepaid shipping label will be emailed to you. Please enclose a copy of the parts packing list and be sure the model and serial numbers are legible on the paperwork. Tag the part with the reported defect.
Customers and non-authorized servicers may order nonwarranty parts at www.u-line.com. Authorized servicers with a servicer login may order non- warranty parts at www.u-lineservice.com.

Ordering Replacement Parts

29

USER GUIDE

R-600A Specifications
For R-600a refrigerant service tips and more videos, go to: www.u-line.com/videos.
! WARNING
Flammability warnings for a pure-iso-butane refrigerant.

Gloves and Eye Protection must be used.
R-600a is considered non-toxic, but is flammable when mixed with air. Keep a dry powder type fire extinguisher in the work area.

Technician must observe all federal, state and local laws regarding refrigerants.
R-600A Specifications

R-600a is heavier than air, do not allow any leakage/migration to low areas such as basements and stairs.
Never use a torch on a fully charged refrigeration system.
Never substitute U-Line OEM replacement parts or methods of construction.
R-600a must be stored and transported in approved containers.
30

USER GUIDE

! WARNING
Only skilled and well trained service technicians permitted to service R-600a equipped products.
All tools and equipment must be approved for use with R-600a refrigerant.
Local, state and federal laws, standards must be observed along with proper certification and licensing.
Ventilation is required during servicing.
No conversions to R-600a from any other refrigerants. OEM R-600a equipped unit only.
Service area must be free of ignition sources.
No smoking is allowed in the service area.
All replacement electrical components must be OEM and installed properly (sealed and covered).
If the evaporator is cold prior to service, it must be thawed prior to service.
When using a vacuum pump, start pump before opening refrigeration system.
Vacuum pump and recovery equipment should be at least 10 feet from the work area.
It is recommended that a simple LPG gas detector is on site during service.
Ensure that all R-600a is removed from the system prior to brazing any part of the sealed system.
Only a clean, dry leak free system should be charged with R-600a.
R-600A Specifications

R-600A SPECIFICATIONS/LABELING R-600a equipped products are labeled (both the unit and the compressor). R-600a is colorless and odorless. R-600a is considered non-toxic, but is flammable when mixed with air. Do not remove or alter any R-600a labeling on the product. Use only a refrigerant grade R-600a from a properly labeled container. RECOVERING/RECLAIMING R-600A (R-600a has been exempted from recovery/reclaiming requirements by the US EPA) Recovery/Reclaiming equipment must be approved for use with R-600a. Ensure the evaporator is at room temperature prior to recovery/reclaiming R-600a. Use a common piercing pliers or piercing valve to remove R-600a from the compressor process tube. (Note: Piercing devices must not be left on the system and must be replaced with a Schrader type valve.)
31

USER GUIDE

Evacuate/reclaim via the piecing pliers to ensure the system is empty of R-600a before any system work is performed.
The recovery cylinder must be evacuated (no air inside) prior to accepting R-600a. The recovery cylinder must not be filled more than 45% safe fill level and refrigerants must not be mixed. The recovery cylinder must be clearly marked with R600a and Flammable Warning labels. Ensure proper ventilation during recovery/reclaiming of R600a. Start vacuum pump/recovery pump prior to piercing the compressor process tube. Follow recovery/reclaim OEM instructions for the specific equipment used. SYSTEM REPAIR Ensure no residual R-600a refrigerant is left within the system prior to repair (simple venting is not sufficient). Evacuate and charge with dry nitrogen for leak checks. Repair leaks or replace system parts as required.

When re-brazing, the system must be purged with dry nitrogen and at least one access point open to the atmosphere. When re-brazing, proper ventilation is required along with constant monitoring for the presence of R600a refrigerant. The filter dryer must be replaced any time the sealed system is serviced. No system should be open to the atmosphere for longer than 15 minutes to avoid moisture migration into the system components. LEAK DETECTION After removal of the R-600a, the unit can be charged with dry nitrogen or helium. Electronic leak detection or soap solution can be used to check for nitrogen/helium leaks.
Never use a halide torch or lighted match to check the system for leaks at any time. The high side of the refrigeration system (compressor discharge to outlet of drier) must be leak tested with the compressor running.

R-600A Specifications

32

USER GUIDE

The low side of the refrigeration system (evaporator, compressor and suction line) must be leak tested with the compressor off (equalized pressure).
RECHARGING No air is ever to be allowed inside the refrigeration system (R-600a refrigerant or dry nitrogen only).
Never use a torch on a fully charged refrigeration system.
Install a Schrader Type access port on the compressor process stub.

Proper ventilation during service is required.
Never apply a torch to a charged R-600a refrigeration system.
Use OEM replacement service parts and do not alter the construction of the unit.

Evacuate the system to 100 microns prior to charging.
Weigh in the R-600a charge using a refrigerant scale. (run compressor an extra two minutes to clear the charging hoses).
Seal the Schrader Type access port, a proper cap and seal must be used to close the system.

SUMMARY Safely handling R-600a requires proper procedures and training.
R-600a approved service tools must be used.
R-600a labeling must not be removed or altered.

R-600A Specifications

33

USER GUIDE

System Diagnosis Guide
REGRIGERATION SYSTEM DIAGNOSIS GUIDE

System Condition
Normal

Suction Pressure
Normal

Overcharge Higher than normal
Undercharge Lower than normal

Suction Line
Slightly below room temperature
Very cold may frost heavily
Warmnear room temperature

Partial Restriction

Somewhat

Warm-

lower than

near room

normal vacuum temperature

Complete Restriction
No Gas

In deep vacuum
0 PSIG to 25″

Room temperature (cool)
Room temperature (cool)

Compressor Condenser Discharge

Very hot

Very hot

Capillary Tube
Warm

Evaporator Wattage

Cold

Normal

Slightly warm Hot to warm Cool to hot

Cold

Higher than normal

Hot
Very hot
Room temperature (cool) Cool to hot

Warm

Warm

Top passes warm Lower passes cool (near room temperature) due to liquid

Room temperature (cool) or colder

Room

Room

temperature temperature

(cool)

(cool)

Room

Room

temperature temperature

(cool)

(cool)

Extremely cold near inlet – Outlet below room temperature
Extremely cold near inlet – Outlet below room temperature backing up
No refrigeration
No refrigeration

Lower than normal
Lower than normal
Lower than normal Lower than normal

CONDENSER DRYER

COMPRESSOR

CAPILLARY TUBE

System Diagnosis Guide

34

EVAPORATOR

USER GUIDE

Compressor Specifications
! DANGER
Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when servicing this unit.
Disconnect the power source.
Do not stand in standing water when working around electrical appliances.
Make sure the surfaces you touch are not hot or frozen.

REFRIGERANT VOLTAGE FREQUENCY START WINDING RUN WINDING LRA FLA STARTING DEVICE OVERLOAD

EM2C46CLC-115V R600a 115V ­ 127V 50Hz 5.20 +/- 8% Q at 25 °C (77°F) 7.19 +/- 8% Q at 25 °C (77°F) 8.0A 2.50A PTC 8EA5B1 302KFBYY-53

*All resistance readings are + 10%

REFRIGERANT VOLTAGE FREQUENCY START WINDING RUN WINDING LRA FLA STARTING DEVICE OVERLOAD

EMC46CLT-220V R600a 220-240V 50Hz 20.20 +/- 8% Q at 25 °C (77°F) 30.80 +/- 8% Q at 25 °C (77°F) TSD2-220VT 197JDBYY-73

*All resistance readings are + 10%

Compressor Specifications

35

USER GUIDE

Troubleshooting – Extended
SPECIFIC ERRORS & ISSUES

! CAUTION
Never attempt to repair or perform maintenance on the unit until the main electrical power has been disconnected from the unit.

TROUBLESHOOTING GUIDE

Concern Will not eject ice (water frozen).
Will not fill with water.
Will not stop making ice. Water will not stop filling.
Ejector blades will not stop turning.
Low ice production.
Not freezing (compressor and fan motors operating). Not freezing (compressor not operating – fans operating).

Potential Causes Control setting too cold. Control inoperable (1-2 contacts open) Bin switch inoperable. Limit switch defective (open). Ice maker assembly motor stalled. Broken wire in ice maker circuit. Water soaked cabinet insulation. Dirty condenser. Water supply valve closed. Water switch inoperable (open). Solenoid valve inoperable. Fill tube outlet frozen. Broken wire in water fill circuit. Bin switch inoperable (closed). Bin arm binding. Water switch inoperable (closed). Solenoid valve inoperable. Stalled ice maker motor. Temperature control inoperable. Ice maker is in continuous harvest cycle (contacts 1-2 closed). Control inoperable (1-2 contacts will not open). Hold switch inoperable. Broken wiring. Short in mold heater. Control set too cold. Fan motor stalled. Ice cubes too large. Dirty condenser. Bypass valve stuck open (Frost Free units only). Little or no frost pattern on evaporator. Bypass valve stuck open (Frost Free units only).
Relay inoperable. Overload inoperable (open). Compressor inoperable.

Suggested Remedy Adjust control warmer (counterclockwise). Replace control. Replace bin switch. Replace limit switch. Replace motor. Repair or replace wiring. Replace foamed cabinet assembly. Clean condenser. Open water supply valve. Replace water switch. Replace solenoid valve. Defrost fill tube. Repair or replace wiring. Replace bin switch. Lubricate bin arm pivot points or loosen bin arm lever screw. Replace water switch. Replace solenoid valve. Replace motor. Replace temperature control.
Replace control. Replace hold switch. Repair or replace wiring. Replace heater. Adjust control warmer (counterclockwise). Replace fan motor. Lower water fill adjustment. Clean condenser. Replace bypass valve (Frost Free units only). Check for sealed system leak or restriction. Replace bypass valve (Frost Free units only).
Replace relay. Replace overload. Replace compressor.

Troubleshooting Extended

36

USER GUIDE

Concern
Not freezing (compressor and fans not operating).

Potential Causes Power cord not plugged in. On/Off switch in off position. On/Off switch inoperable (open). Hold switch inoperable (open). Control inoperable (2-3 contacts open). Broken wire in freeze circuit. Ejector blades not in freeze position (12:00)

Compressor overheating.
Compressor will not stop operating.
Water leak (under unit).
Water leak (inside unit).
Excessive frost buildup.
Noisy.
Ice buildup in drain trough or drainage problem.
Unit will not defrost (Frost Free units only). Fresh food temperature too cold.

Condenser air flow restricted. Condenser fan blade obstructed. Condenser fan motor stalled. Compressor inoperable. Control set too cold. Control inoperable (2-3 contacts will not open). Control sensing bulb not sensing mold temperature. Evaporator fan stalled (Frost Free units only). Water supply line leaking at solenoid valve inlet. Water line leaking at solenoid valve outlet. Water line leaking at fill tube. Defrost drain line not in drain pan. Crack in water line. Ice maker assembly fill cup obstructed. Fill ice cup and fill tube out of alignment. Water level too high. Defrost drain plugged (Frost Free units only). Door gasket not sealing properly. Door out of alignment. Water soaked cabinet insulation. Light stays on when door is closed. Copper refrigeration tube touching cabinet. Fan blade touching shroud. Fan blade obstruction (wiring, foam insulation, packaging material). Obstructed drain cup or tube. Drain trough heater failed (Frost Free units only). Kinked drain tube. Drain trough spout and drain cup not aligned. Bypass coil inoperable. Defrost timer inoperable. Bypass valve inoperable. Temperature control set too cold. Bin/Freezer door not closing. Ice bucket not fully inserted.

Suggested Remedy Plug in power cord. Turn switch to on position. Replace On/Off switch. Replace hold switch. Replace control. Repair or replace wiring. Manually advance ejector blades to the 12:00 position (test ice maker and limit switch). Remove restriction (clean condenser and grille). Remove blade restriction. Replace fan motor. Replace compressor. Adjust control warmer (counterclockwise). Replace control. Fully insert bulb into ice maker tube. Rout bulb away from compressor discharge tube. Remove obstruction or replace motor. Tighten fitting or replace fitting gasket and/or fitting. Replace water line and fitting. Tighten clamp or replace fill tube assembly. Position drain line in drain pan. Replace water line. Remove obstruction. Align fill tube and fill cup. Adjust water level. Ice in drain trough (Frost Free units only) (see below). Adjust door hinges or replace door gasket. Adjust door hinges. Replace foamed cabinet assembly. Repair or adjust light bracket. Carefully adjust tubing. Adjust fan mounting or shroud. Remove obstruction.
Clear obstruction. Replace drain trough heater (Frost Free units only). Align drain trough and drain cup. Reroute drain tube. Replace bypass valve. Replace defrost timer. Replace bypass valve. Adjust control to warmer setting (counterclockwise). Adjust or replace door. Check for ice behind bucket and push ice bucket in place.

Troubleshooting Extended

37

USER GUIDE

ICE MAKER DIAGNOSIS FLOW CHART

Sealed System Leak Electrical Failure Compressor Failure Fan Motor Failure Defrost System Failure

DOES THE UNIT REFRIGERATE?

NO

INTERMITTENT

YES

Low Voltage Voltage Drop Wiring

DOES THE UNIT HARVEST ICE IF THE EJECTOR BLADES ARE MOVED BY HAND OR WITH A
WRENCH ?

YES

NO

Temperature Control Failure Water Adjustment Bin Switch Failure
WHERE DO THE EJECTOR BLADES
STOP?
EVERYWHERE

AT 3:00

AT 12:00

Ice Motor Failure Hold Switch Failure Limit Switch Failure Binding Cam/Ejector

IS THERE VOLTAGE AT THE SOLENOID VALVE TERMINALS
DURING HARVEST?

Mold Heater Failure

NO

YES

Water Switch Failure

Solenoid Valve Failure
UL183-11

Troubleshooting Extended

38

USER GUIDE

ICE MAKER OPERATING CYCLES Freeze Cycle
· Temperature control terminals 2 and 3 are closed. · Power to the condenser. · Power to the condenser fan.

ON OFF SWITCH

black

FAN

MOTOR

black
LIMIT SWITCH

COMP. START RELAY

OVER LOAD

black

black

orange

black

black black
brown

black blue
WATER C FILL NC
SWITCH

ICE MAKER MOTOR

orange

MOLD HEATER

black

Figure 1. Freeze Cycle

ground

WATER

white

VALVE

HOLD C SWITCH

NC

NO

yellow

2

TEMP.

red NO

C

3 CONTROL 1

BIN SWITCH

orange

UL183-4

Troubleshooting Extended

39

USER GUIDE

Harvest-1 Cycle · Temperature control terminals 2 and 3 are open – 2 and 1
close.

· No power to the compressor or condenser fan.

· If bin arm is down, power goes through bin arm switch to the ice maker motor. If bin arm is up, the ice maker will not harvest.

ON OFF SWITCH

black

FAN

black

MOTOR

black ground

black LIMIT SWITCH
black

COMP. START RELAY

OVER LOAD

black orange black

brown

black blue
WATER C FILL NC
SWITCH

ICE MAKER MOTOR
MOLD HEATER

orange black

WATER

VALVE

white

HOLD

C

SWITCH

NC

NO

yellow

2

3

TEMP.

red

CONTROL 1

NO

C

BIN

SWITCH

orange

UL183-5

Figure 2. Harvest-1 Cycle (Hold Switch in Normal Position)

Troubleshooting Extended

40

USER GUIDE

HARVEST-2 CYCLE
· Ice maker ejector blades reach approximately 2:00 position and cam depresses the hold switch. Power goes through the hold switch to the ice maker motor and mold heater.

· Ejector blades stall on ice and ice maker motor pulsates until mold heater warms and ice releases.

ON OFF SWITCH

black

FAN

black

MOTOR

black ground

black LIMIT SWITCH
black

COMP. START RELAY

OVER LOAD

black orange black

brown

black blue
WATER C FILL NC
SWITCH

ICE MAKER MOTOR
MOLD HEATER

orange black

WATER

VALVE

white

HOLD C SWITCH

NC

NO

yellow

2

TEMP.

red NO

C

3 CONTROL 1

BIN SWITCH

orange

Figure 3. Harvest-2 Cycle (Hold Switch in Switched Position)

UL183-6

Troubleshooting Extended

41

USER GUIDE

WATER FILL CYCLE · Ice maker ejector blades reach approximately 10:00
position and cam depresses the water fill switch.

· Power to the water valve. Ice maker mold fills.

ON OFF SWITCH

black

FAN

black

MOTOR

black
LIMIT SWITCH

COMP. START RELAY

OVER LOAD

black blue
WATER C FILL NC
SWITCH

black brown

black

black

orange

black

ICE MAKER MOTOR
MOLD HEATER

orange black

Figure 4. Water Fill Cycle
EJECT CYCLE · Ejector blades push ice into bucket and stop at 12:00
position.

· Temperature control terminals 2 and 3 have closed during harvest cycle.

· Next freeze cycle begins with power to the compressor and condenser fan.

ground

WATER

VALVE

white

HOLD C SWITCH

NC

NO

yellow

2

TEMP.

red NO

C

3 CONTROL 1

BIN

SWITCH

orange

UL183-7

Troubleshooting Extended

42

USER GUIDE

TEMPERATURE CONTROL SPECIFICATIONS
Double Throw Ice Maker Thermostat Numbers 4548, AR-19-12, 2636, 2690, 2691, 2717, 2783, 2782-S, 2763-S, 2780, 80-26005-02
These temperature controls are double throw, single pole controls. The sensing tube is inserted into the ice maker mold and senses mold temperature. After ice is sensed in the mold, the 2-3 contacts open (stopping the compressor) and the 2-1 contacts are closed (starting the ice maker motor). The 2-3 contacts close (2-1 contacts open) before the end of the ice harvest cycle.The hold switch prevents power going back to the compressor. This prepares the control for the next cycle.

YELLOW WIRE CONNECTION

1 2
3
ICE MAKER CONTROL

.
RED WIRE CONNECTION BLUE/BLACK WIRE
CONNECTION 183-8

2 FREEZE POSITION

1

1

2

3

3

ICE HARVEST POSITION

CYCLE
FREEZE HARVEST

OPEN CIRCUIT
2 – 1 2 – 3

CLOSED CIRCUIT
2 – 3 2 – 1

Figure 5. Temperature Controls – Manual Defrost Ice Makers

183-9

Troubleshooting Extended

43

USER GUIDE
LIMIT SWITCH SPECIFICATIONS · Normally closed Bi-metal switch · Open temperature: 104°F · Close temperature: 83°F The function of this switch is to open in the event of an overheating condition. This bi-metal thermostat is normally closed and does not initiate the ice harvest cycle. The ice harvest cycle is initiated by a double throw, single pole temperature located remotely from the ice maker assembly.
3.00
28.12

Figure 6. Limit Switch

183-10

Troubleshooting Extended

44

USER GUIDE

REPLACING ICE MAKER ASSEMBLY (CO29F ONLY) 1. Unplug the unit from the main power source.
2. Disconnect ice maker wire harness at plug (1).
3. Remove control capillary tube from sensing tube on ice maker assembly (2).
4. Remove water inlet tube.
5. Remove front cover (3).
6. Advance the ejector blade to the 3 o’clock position by turning the 5/16″ hex head on the small brass gear counterclockwise (4).
7. Remove three screws from wall of freezer housing (5).

8. Remove ice maker assembly. 9. Place new ice maker assembly into position and secure
with three screws (5). 10.Reconnect wire harness at plug. 11.Insert control capillary tube into ice maker sensing
tube. 12.Insert water inlet tube. 13.Apply Permagum® to all exit holes. 14.Install back panel. 15.Plug in unit and test.

Troubleshooting Extended

Figure 7. Ice Maker Assembly
45

USER GUIDE

REPLACING ICE MAKER ASSEMBLY (ALL MODELS EXCEPT CO29F) 1. Remove back panel.
2. Disconnect all wires at bell connectors (5 wires-Models BI95, BI98 or SP18; or Plug-Models).
3. Remove capillary tube from sensing tube on ice maker assembly (2).
4. Remove water inlet tube.
5. Remove front cover (3)
6. Advance ejector blades to the 3:00 position by turning the 5/16″ hex head on the small brass gear counterclockwise (4).
7. Remove two screws from the side wall of evaporator (5).
8. Remove screws from the bottom of the evaporator plate.
9. Remove ice maker assembly from evaporator shelf.
10. Clean alumilastic from evaporator shelf.
11. Apply 1/4″ layer of fresh alumilastic to heater side of new ice maker.
12. Replace parts in reverse order of removal.
13. Reconnect all wires.
14. Insert capillary tube into ice maker sensing tube.
15. Insert water inlet tube.
16. Apply permagum to all exit holes. Mount back panel.

17.Mount the back panel.
18.Plug in unit and test.
220 Volt Conversion List All models listed in this manual are equipped to run on 110/115 volt. This document is a conversion list for the applicable 220 volt parts for the following models:
· SP18
· BI95
· BI98
· SS1095

110V P/N 5263-S 80-39015-00 402

220V P/N 5195 628109 619

402-29/1175

620

2552A 5402-S 150 5414 5413

2555A 5404-S 650 5418 5417

Description
Fan Motor
I.M. motor (ice makers)
Ice maker assembly Models SP18, BI95, BI98 and model SS1095
Ice maker assembly Models SP18, BI95, BI98 and model SS1095
Water valve
Compressor (ice makers)
Faceplate assembly
Relay
Overload

Troubleshooting Extended

46

USER GUIDE
Defrost
This unit requires manual defrost, periodically.
Inspect the interior walls for frost build up every 3 – 4 weeks. Defrost your unit when 1/4″ of frost builds up on the interior walls. Frost will build up faster in humid environments and when the door is opened frequently.
To defrost, remove ice bucket, turn off unit, leave door open, and allow frost/ice to melt naturally. Do not use tools to chip or scrape the frost as it may damage your unit. Use a towel to absorb melting frost/ice. Before turning the unit back on, make sure all the frost is gone and the unit is dry.

Defrost

47

USER GUIDE

u-line.com

Replace Ice Maker
The new ice maker assembly you have received will have a plug-in connection. In some instances you may need to cut plug off from cable and hard-wire the connections.
REMOVE ICE MAKER 1. Unplug the unit.
2. Disconnect ice maker wire harness at plug.
3. Disconnect thermistor plug.
4. Remove water inlet tube.
5. Remove front cover.
6. Advance ejector blade to the 3 o’clock position by turning the 5/16″ hex head on the small brass gear counterclockwise.
7. Remove three screws from wall of freezer housing.
8. Remove ice maker assembly.

INSTALL ICE MAKER 1. If ice maker sits on evaporator (as shown) be sure to
apply the included Alumilastic paste.
Apply here
2. Reconnect plug. 3. Reconnect thermistor plug. 4. Insert water inlet tube. 5. Apply Permagum® to all exit holes on back of unit. 6. Install back panel. 7. Plug in unit and test.

Replace Ice Maker

48

U-Line Corporation (U-Line) Limited Warranty
One Year Limited Warranty
For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during normal business hours.
Two Year Limited Warranty (5 Class Product)
For two years from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during normal business hours.
Available Second & Third Year Limited Warranty
In addition to the standard one and two year warranties outlined above, U-Line offers a one year extension of the warranties from the date of purchase, free of charge. To take advantage of this extension, you must register your product with U-Line within 60 days from the date of purchase at u-line.com and provide proof of purchase. Nugget Ice Machine proof of purchase must include the purchase of an in-line water filter and filter head to qualify for this additional limited warranty.
Five Year Sealed System Limited Warranty
For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during normal business hours.
Terms
These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and maintained in accordance with your product’s User Guide.
The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or under any warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal rights, and you may also have other rights which vary from state to state.
Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of merchantability or any warranty fit for a particular purpose is limited to the duration of these warranties, and only extends to five years in duration for the parts described in the section related to the five year limited warranty above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
· The warranties only apply to the original purchaser and are non- transferable. · The second, third, and five year warranties cover products installed and used for normal residential or designated marine use only. · The warranties apply to units operated outside only if designed for outdoor use by model and serial number. · U-Line Commercial products are covered by the one year and 5 year limited warranties and are not eligible for the second and
third year limited warranties. · Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties. · The start of U-Line’s obligation is limited to four years after the shipment date from U-Line. · In-home instruction on how to use your product is not covered by these warranties. · Food, beverage, and medicine loss are not covered by these warranties. · If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip
charge or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense. · Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only
and no coverage is provided for cosmetic defects. · Signal issues related to Wi-Fi connectivity are not covered by these warranties.
For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line: 8900 N. 55th Street, Milwaukee, WI 53223 · u-line.com · onlineservice@u-line.com · +1.414.354.0300
Copyright U-Line Corporation. All Rights Reserved. | Publication Number 30379 | 11/2022 Rev. P
49

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals