tibber RJ12 Pulse P1 Pulse Meter User Manual
- June 5, 2024
- tibber
Table of Contents
tibber RJ12 Pulse P1 Pulse Meter
Let’s get started!
-
Download Tibber
Search for Tibber on
the Apple App Store/
Google Play Store or scan the QR code to download the app. -
Create your Tibber account
An energy subscription is optional. -
Pair the Pulse
Go to Power-ups in the app and add Pulse.
You need to contact your grid company to enable the data from your meter.
Intended use
The Pulse is intended to be used to read data from your electricity meter and transfers it to the Tibber app. Depending on your smart meter, the refresh rate varies between 1 to 10 seconds. The product is intended for domestic use.
Retaining instructions Read and understand this manual and its safety
instructions before using this product. Failure to do so can result in severe
injury or death. Follow all the instructions to avoid fire, explosions,
electric shocks or other hazards that may damage property. The product shall
only be used by persons who have fully read and understand this user manual’s
content. Ensure that every user of the product has read these instructions
prior to use and follows them. Keep all safety information and instructions
for future reference and pass them on to subsequent product users. The
manufacturer
is not liable for cases of material damage or personal injury caused by
incorrect handling or non-compliance with the safety instructions. In such
cases, the warranty will be voided.
Obtaining documentation and information
The latest version of the documentation is available in multiple languages at
https://pulse.tibber.com/rj12_manual
Comments on the document can be submitted to our support team in the Tibber
app or sent via email to hello@tibber.com. Your
comments are much appreciated!
2. Description of the product
Technical details
The Pulse is designed to work with energy meters that support the P1 style
RJ12 port that follows the DSMR 4.0 standard or a more up to date version of
it (Dutch Smart Meter Requirements Version 4.0 which also includes IEC
62056-61 and IEC 62056-21 data exchange). If your smart meter supports a
version of the DSMR standard developed prior to 4.0 the Pulse will require
external power through USB (power supply and cable are not included in the
product).
Note that the “Swedish recommendation for customer
interface in smart meters” (Branschrekommendation för lokalt kundgränssnitt
för elmätare) is based on DSMR 5.0 but does not specify that the meter may
provide power to external devices from the P1 port. Most meters in Sweden will
provide power to the Pulse despite it not being required. An exception is the
Kamstrup Omnipower devices as they do not supply power.
The Pulse is meant to be connected to the Tibber app (available on Google Play
and Apple App Store). There is an API available for advanced users at
https://developer.tibber.com/ for further data collection.
The Pulse may only be used with the cable included in the delivery. Using a
different cable can cause damage to the product, smart meter or even personal
injury.
Parameter | Unit |
---|---|
Device name | Pulse |
Type/Model | RJ12 / Lando edition |
Technical life span | At least 5 years |
Energy consumption | 500mW during pairing |
175mW during normal operation
Frequency band| 2401 MHz to 2483 MHz
Maximum power transmitted| 20dBm
Weight| 40.5g
Dimensions| 33mm x 80.5mm x 24.5mm
Physical interface| RJ12/USB
Supported protocols| DSMR 4.0, DSMR 5.0, 62056-61, IEC
62056-21
Cable length| 1m
Cable connectors| RJ12
Cable wiring| Normally wired: 1-1, 2-2, 3-3, 4-4,
5-5, 6-6
Physical protection (IP rating)| IP20 (not waterproof)
Temperatur range| -20°C to 50°C
Product compliance
Hereby, Tibber AS declares that the radio equipment type Pulse RJ12-version
complies with the directive 2014/53/EU. The complete version of the EU
declaration of conformity is available at the following internet address:
https://pulse.tibber.com/rj12_conformity
Installation and setup
Follow the instructions on the first page of this manual. You will be guided through the setup process in the Tibber app. Connecting the Pulse to the smart meter and pairing it with your Wi-Fi® network.
4. Troubleshooting
4.1 Explanation of common visual signals
Signal Meaning
Normal operation|
White / White with blinking| Pulse is booting up
Green| Pulse is ready to be paired
Green blinking| A phone has been connected to the Pulse (only during pairing)
Blue blinking| Pulse is trying to connect to the Wi-Fi® and our server
Weak blue| Pulse is connected to our server
Weak blue / short blue blinking| Blue blinking indicates data transfer to our
server
Yellow blinking| Firmware is being updated, do not disconnect from the power
source.
Error states|
Continuous red| Connection to Wi-Fi® network failed. Usually, the light will
alternate between this state and blue blinking when trying to connect to the
Wi-Fi®
Red blinking| Pulse connected to the Wi-Fi®, but not able to reach the server
Table 2: Common visual signals
Problem-solving from LEDs
Signal Meaning
Continuous red light| It is possible that the Wi-Fi® signal is not strong
enough. Try to improve the signal by moving the pulse to another spot.
Red blinking| Try to reset the device by holding the reset button for at least
5 seconds. Then pair the device again following the instructions in the app.
Table 3: Problem-solving from signals
If you encounter other light combinations or have any problems with our
product, please contact us, preferably in the app or via email to
hello@tibber.com If you are having any problems
during pairing; first try again then if it still fails please contact us
through our support channels or see our troubleshooting guide at
https://pulse.tibber.com/rj12_troubleshoot
Safety instructions
WARNING: When accessing the fuse or meter cabinet, make sure you first inspect the meter and its surroundings to ensure there are no hazards in the form of loose cables, exposed copper or other objects that shall cause an electrical shock. If you encounter any of these threats, abort our product’s installation immediately and contact an electrician. Before use, inspect the device for any physical damage. If there is any physical damage to the device, stop the installation process immediately and contact support.
CAUTION: Use only the included cable to avoid damage to the device and/or the smart meter. If the cable is damaged, contact us in order to receive a new one. Avoid placing the device in a very hot or humid environment. Failure to do so can reduce the lifetime of the device. Do not place the device outside in rain or snow. The device is NOT waterproof. Using the device outside of the specified temperature range (-20°C to 50°C) may cause it to malfunction. If the device is opened, it shall be damaged. If it is dropped, it shall be damaged. Any other type of shock can also damage it. Store the device in a dry environment.
Disposal
6.1 Disposal of electronic components
This symbol on the product, the accessories or packaging indicates that this device may not be treated as unsorted municipal waste, but may be collected separately! If you live within the EU or another European country that operates separate collection systems for electrical waste and electronic equipment, ensure the device’s appropriate disposal at a collection recycling location. By properly disposing of the device properly, you help avoid possible environmental and public health hazards that shall otherwise be caused by improper treatment of waste equipment. The recycling of materials contributes to the conservation of natural resources.
6.2 Disposal of packaging waste
The packaging is made of environmentally friendly materials, which may be
disposed of at your local recycling facilities. By properly disposing of the
packaging and packaging waste, you help avoid possible environmental and
public health hazards.
Tibber AS, Hafstadvegen 23, 6800 Førde, Norway
hello@tibber.com | Copyright © 2021 by Tibber
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>