BLINKCAST Flexion 6 Led Single Colour Lighthead Instruction Manual
- June 16, 2024
- BLINKCAST
Table of Contents
BLINKCAST Flexion 6 Led Single Colour Lighthead Instruction Manual
Wiring
-
To Chassis Ground: ……………………………………. BLACK
-
To+VDC for Warning Mode1 (fuse @ 1A):………….. RED
Default Flash Pattern – FP#2 Single [2Hz] -
To+VDC for Warning Mode 2 (fuse @ 1A):……… WHITE
Default Flash Pattern – FP#1 Double [2Hz] -
To+VDC for Warning Mode 3 :……………..RED+WHITE Default Flash Pattern – FP#18 Steady Scene
-
For Synchronization and Flash Pattern:……..YELLOW Connect YELLOW wire of all lightheads together for synchronization. (All lightheads should be set to the same Flash Pattern)
Operation
Flash Pattern (Single Colour)
1| Double| [2Hz]
2| Single| [2Hz]
3| Triple| [2Hz]
4| Quad| [2Hz]
5| Random
6| Steady EF*
7| Single| [SAE][CA13]
8| Double| [SAE]
9| Triple| [SAE]
10| Quad| [SAE]
11| Quint| [SAE]
12| Mega
13| Giga
14| Ultra| [SAE]
15| Single-Quad
16| Singe H/L
17| Single-Triple-Quint
18| Steady Scene
19| Cruise
20| Sweep Single TA
21| OFF
For Flash Pattern Selection:
Each Warning Mode may select and save one Flash Pattern. While activating a
Warning Mode, momentarily apply YELLOW wire to +VDC:
- Once to the next pattern.
- Quick three times to FP#1 (refer to Flash Pattern Chart)
Shortcut Setting for Steady EF (External flasher):
This shortcut allows quick changing of trigger wires setting to each colour
with Steady EF pattern all at one time. Momentarily apply YELLOW wire to +VDC
for 3~4 seconds (visual feedback: ON→OFF→ ON) while activating any warning
mode. Colour mode and Flash Pattern of each warning mode will be set to.
Warning Mode 1 = Colour 1, FP#6 Steady EF
Warning Mode 2 = Same Color mode, FP#21 OFF
Warning Mode 3 = Same Color mode, FP#21 OFF
Setting Mode
The following settings will require user to enter SETTING MODE to operate; to enter:
- Power off the unit completely and power up by applying +VDC to RED (or WHITE or RED+WHITE) and YELLOW wires simultaneously.
- Remove YELLOW wire from +VDC to enter SETTING MODE. Lightheaded will then flash in low-power while in SETTING MODE.
- To save and exit the setting, simply disconnect the power after operation.
For Simultaneous or Alternating Synchronization:
To change Group, while in setting mode, momentarily apply YELLOW wire to +VDC
for 3~4 seconds. the lighthead will display short flashes.
Set by BlinkCast
Programmer only
- Single flash = Group 1
- Three flash = Group 2
- Four flash = Group 3
- Five flash = Group 4
- Double flash = Group 5
- Six flash = Group 6
- Seven flash = Group 7
- Eight flash = Group 8
NOTE:
- Lightheads of the same Group will flash together.
- Lightheads of the Group 1 & Group 5 will flash alternately.
Reset to Factory Default Settings:
While in setting mode, apply YELLOW wire to +VDC for more than 5 seconds. The
lightheaded will display fast short flashes to signify restoring successfully.
BlinkCast Ready
This product can be configured ideally by using Blink Cast Programmer with desired Flash Pattern, Group (Phase), and Color Mode to save your installation time! Contact your sales representatives or see your User Manual of Blink Cast Programmer for detailed information.
Installation
Curved Surface / Flat Surface
-
[Curved Surface] Use curvature template to check surface countability: make sure surface curvature is over 120 degree.
Both points can touch: mountable
▼One or no point can touch: uncountable -
Mark and drill a wire passage hole on the mounting surface. Make sure no vehicle parts could be damaged by the drilling process. (Thoroughly deburr hole and use grommet for wire passage hole if needed)
-
Clean and dry the mounting surface with alcohol prep pad provided. (or 50:50 mix of isopropyl alcohol and water)
-
Remove the tape liner from the tape and apply the lighthead to the surface and press it firmly for 30 seconds. Full adhesion and bonding will be achieved after 72 hours at room temperature.
-
[Flat Surface] For best secure installation, it is recommended to always mount lightheads with screws. [Curved Surface] Due to lighthead tension, it is required to always mount lightheads with screws on curved surface.
-
Once secured, apply screw covers onto the lighthead for best aesthetic. (use silicon glue to better scure the screw cover.
Prohibition
No Pulling
No Warping
No Bending Inwards
No bending over 120°
Mounting Dimensions
Curvature Template template
Read User Manual Online (PDF format)