FuturaSun FU 390 MV Plus Duetto Solar Panel Installation Guide
- June 13, 2024
- FuturaSun
Table of Contents
FuturaSun FU 390 MV Plus Duetto Solar Panel
Product Usage Instructions
- Installation
- Ensure the installation area receives adequate sunlight throughout the day.
- Mount the solar panel securely using the appropriate mounting hardware.
- Connect the cables to the junction boxes following the provided guidelines.
- Maintenance
- Regularly clean the glass surface of the solar panel to maintain optimal efficiency.
- Check for any damage to the frame or cells and replace them if necessary.
FAQs
- Q: What is the maximum power output of the solar panel?
- A: The maximum power output is 390 W.
- Q: What is the maximum system voltage supported by the solar panel?
- A: The maximum system voltage is 1500 V.
- Q: What are the certifications of the product?
- A: The product is certified with ISO 9001, ISO 14001, and ISO 45001, and ongoing certifications include IEC EN 61730, IEC EN 61215, and Class 1 UNI9177.
KEY BENEFITS AND FEATURES
- Power 390 Watt
- Green coloured glass and frame for special architectural requirements (similar to RAL 6000)*
- Ideal for “invisible” greenfield installations and fences
- 108 M10 n-type bifacial half-cut cells
- Coloured glass for a consistent appearance over time
- 1722 x 1134 x 30 mm
Guarantee
Performance guarantee
- 30-years performance warranty with max power decrease from 2nd year 0.4%/year
- 99% at the end of first year
- 92% at the end of 20th year
- 87% at the end of 30th year
Product guarantees
- 15-year product warranty
- Third-party product liability insurance
- All FuturaSun’s modules are designed and guaranteed by the Italian headquarters
Mechanical Specifications
Dimensions | 1722 x 1134 x 30 mm |
---|---|
Weight | 25.4 kg |
Glass | Front – 2.0 mm solar glass with ARC |
Back – 2.0 mm Solar glass
Cells| 108 monocrystalline bifacial half-cut MBB n-type cells 182 x 91 mm
Frame| Varnished anodized aluminium frame with mounting and drainage holes
Junction boxes| Certified according to IEC 62790, IP 68 approved, 3 bypass
diodes
Cables| Solar cable, length 1100 mm or customized assembled with 4mm²
compatible connectors
Backglass| Green
Maximum reverse current (Ir)| 25 A
Maximum system voltage| 1500 V
Mechanical load (snow)| Design load: 3600 Pa, (5400 Pa including safety factor
1.5)
Mechanical load (wind)| Design load: 1600 Pa, (2400 Pa including safety factor
1.5)
Electrical data| FU 390 MV|
---|---|---
TEST CONDITIONS| STC| BSTC
Module power (Pmax)| W| 390| 432.15
Open circuit voltage (Voc)| V| 38.12| 38.95
Short circuit current (Isc)| A| 12.46| 13.73
Maximum power voltage (Vmpp)| V| 32.15| 32.78
Maximum power current (Impp)| A| 12.19| 13.18
Module efficiency| %| 19.97| 22.13
Sorting tolerance| W| 0/+5
Electrical data – NOCT| | FU 390 MV
---|---|---
Module power (Pmax)| W| 294
Open circuit voltage (Voc)| V| 36.24
Short circuit current (Isc)| A| 10.06
Maximum power voltage (Vmpp)| V| 29.93
Maximum power current (Impp)| A| 9.84
Temperature ratings
Temperature coefficient Isc | %/°C | 0.05 |
---|---|---|
Temperature coefficient Voc | %/°C | -0.28 |
Temperature coefficient Pmax | %/°C | -0.29 |
NOCT** | °C | 45 |
Operating temperature | °C | from -40 to +85 |
Certifications
Factory | ISO 9001 – 14001 – 45001 |
---|---|
Product | Ongoing: IEC EN 61730, IEC EN 61215, |
Class 1 UNI9177
Packaging
Quantity / Pallet | 36 pcs |
---|---|
Container 40’ HC | 936 pcs / 26 pallets |
The information included in this module datasheet is subject to change without notice and is provided for informational purposes only. No contractual rights are established or should be inferred because user relies on the information contained in this module datasheet. Please refer to the appropriate module user guide and module product specification document for more detailed technical information regarding module performance, installation and use.
- Standard Test Conditions STC: 1000 W/m2 – AM 1.5 – 25 °C – tolerance: Pmax (±3%). Voc (±4%). Isc (±5%)
- Bifacial Standard Test Conditions (BSTC) Front side irradiation 1000 Wp/sqm Back side reflection irradiation 135 Wp/sqm Ambient temperature 25 °C
- Nominal Operating Cell Temperature NOCT: 800 W/m2 – T=45 °C – AM 1.5 EN_02
- Maximum power 390 W
- Technology inside n-type
CONTACT
- Riva del Pasubio 14, 35013 Cittadella, PD, Italy
- +39 049 5979802
- info@futurasun.it
- futurasun.com.