Thermex M 513210068214062023 Integro 51 II Basic Stainless With Motor Instruction Manual
- June 16, 2024
- thermex
Table of Contents
513210068214062023 Integro
51 II Basic Stainless With Motor
Instruction Manual
M 513210068214062023 Integra 51 II Basic Stainless With Motor
Instructions
INTEGRO 51 II BASIChttps://www.thermex.dk
WARNINGS
- the range hood is designed and manufactured according to DS/ EN 60335-1.
- this range hood is only for use in private house holdings, if used for other purposes the warranty will be repealed.
- Installation must be performed by a skilled electrician in accordance with the specifications given by Thermax Scandinavia A/S (Thermax) and legislation in force.
- Thermax disclaims all responsibility in regards to damages caused by wrong installation, mounting or use.
BEFORE Mounting/commissioning
- Inspect the range hood for transport damages, flaws and defects immediately after the receipt.
- transport damages must be filed to the haulage contractor and Thermax immediately after the receipt.
- Flaws and defects must be filed to Thermax within 8 days the receipt, and not later than mounting/commissioning.
Mounting
-
the range hood is intended for working at 230 Volt ±10%~ 50 HZ in referring to EN 50160.
-
connect the hood with the attached plug. Note: the hood Must have earth if the plug has an earth connection.
-
For models with external motor applies that Knot to use common zero by installing the hood and engine, as this will affect the control.
-
It Must be ensured that the motor can be used with the selected range hood when using an external motor from another supplier.
Otherwise the warranty no longer apply. -
Do not plug in the range hood until the mounting is complete.
-
the air must not be discharged from the hood into a pipe used for extraction from devices using gas or other fuels. Such devices must have a separate vent.
-
the national legislation on air emissions must be observed.
-
Always use the original dimension of the vent. By reducing the dimension of the vent, the performance will be reduced and the sound level will be increased.
-
the vent to the open air, must be as short as possible in order to get the greatest possible capacity of the range hood.
-
the number of bends on the vent ought to be minimized, to gain the greatest possible capacity of the range hood.
-
Thermax recommends to always use sound and condensation insulated vent hose at the carrying through in unheated spaces.
-
Thermax recommends that there is used for a muffler to minimize the noise level when using flexible hose.
-
Using the flexible hose must always ensure that this is fully extended to minimize air resistance and thereby achieve maximum absorbency.
-
Different materials takes different raw plugs and screws. Use raw plugs and screws indented for the material the range hood is to be mounted in.
-
If the instructions for the installation of screws and fittings are not followed, it may result in electrical shock. • the minimum distance to gas stoves from the burner’s edge to the underside of the hood Must be minimum 65 cm in accordance with EN 60335-2-31.
-
Thermax recommends that the space between the lower edge of the range hood and cooker is between 50 cm and 70 cm, valid for all cabinet range hoods, islands and wall mounted range hoods.
-
Always control the stated minimum distance between cooker and range hood in the manual for the cooker. If the manual for the cooker states a greater distance than what Thermax recommends the manual for the cooker Must be followed.
-
Thermax recommends that the space between cooker and range hood does not exceed 3 meters for range hoods integrated in the ceiling
INSTALLATION
RECIRCKULATION FILTER
Installation OF Recycling Filters
2 pcs must be used. Recirculation filters are mounted on the hoods motor. the
filters are mounted on the side of the engine, as illustrated on the sketch.
Replacement OF Recycling Filters
the recycling filters must be replaced at least twice a year. For frequent
cooking, the recirculation filters should be replaced more often.
ELECTRICAL INSTALLATION
OPERATION AND CONTROLS
control PANEL
Adjusting the Light
MAINTENANCE AND CLEANING
- Always disconnect power before cleaning.
- the hood must be cleaned regularly to ensure optimal operation and long service life.
- Grease and dust debris are collected in the filter and may risk igniting with insufficient cleaning.
- the hood should be cleaned inside and out frequently to avoid grease stains on walls or other surfaces.
DAILY cleaning
- For cupboard-integrated, free-hanging and wall-mounted hoods, Thermax recommends that the grease filter be wiped with a damp cloth after each cooking session. It requires very little effort every day to keep your cooker hood clean and effective.
- Steel surfaces are cleaned with a damp cloth with detergent and treated with 3M Polish.
- Lacquered surfaces should be cleaned with a damp cloth with detergent/washing-up liquid. Never use abrasives.
cleaning the GREASE Filters
Grease filters should be cleaned as needed. Thermax recommends as a minimum
that the filter is cleaned at the following intervals, depending on the fat
used for frying:
- Frying margarine – filter cleaned every 3 weeks
- Liquid margarine – filter cleaned every 2 weeks
- Oil – filter cleaned once per week
- Deep fat frying – filter cleaned 2-3 times per week
The grease filters are cleaned in the following way:
- Open the glass door
- Remove the grease filter behind the glass plate and the filter in the base by pulling on the filter-locking mechanism to loosen the filter from the hood.
- Place the filters in warm soapy water and clean if necessary with a soft brush.
- Rinse with warm water.
- Leave the filters to dry on a dishcloth or similar.
- Repeat the process if necessary.
- Re-attach the filters..
The filters can also be washed in the dishwasher, although please note that
machine washing can result in discoloration of the filters. Discoloration of
the filters does not affect performance.
Replacing the Recirculation Filters
If recirculation filters are used, these cannot be washed, but must be
replaced when needed. Thermax recommends that the recirculation filters are
replaced at least 2-4 times per year.
SERVICE
Before reporting service on your thermex range hood, it is important that you
read the installation and/or user instructions carefully. It ensures that
thermex can provide you the best possible assistance.
Service department at thermex can be contacted in preparation to:
- technical support for installation and installation of your range hood.
- clarification of functionalities in your hood.
- Service Request during the warranty on your hood .
Before a service request during the warranty always try to disconnect the
power to the hood for about 5 min. then plug the power back on to see if the
problem is corrected.
If the problem is not corrected, disconnect the power supply to the hood for
one hour. If the hood is still not functioning properly, and the
troubleshooting charts are reviewed, contact the service department.
Note: For inquiries within the warranty, you will be asked for proof of
your purchase in the form of a sales receipt. therefore, always store your
sales receipt
Before the request for service within the warranty, it is important to have all the necessary information ready:
- Error Description
- Model
- the type and serial number of the hood (on the chassis plate)
- Information of purchase
ENVIRONMENTAL CONSIDERATIONS
Packaging
the packaging must be disposed of in accordance with local regulations on
waste management.
Scrapping OF the Product
The symbol on the product or accompanying documentation indicates that this
product may not be disposed of as household waste but must be delivered to the
nearest collection center for the recycling of electrical and electronic
equipment.
THERMEX Scandinavia AS
tel. +47 22 21 90 20
www.thermex.no
service@thermex.no
THERMEX Scandinavia AB
Importation 12 A •
442 46 Hissings Back • Sverige
tel. +46 031 340 82 00
www.thermex.se
info@thermex.se
THERMEX Scandinavia A/S
Purelan +358 942 454 000
www.thermex.fi
info@thermex.fi
References
- Emhætte service | Bestil service til din emhætte hos Thermex »
- Thermex - Diseñamos y desarrollamos campanas extractoras
- Huolto
- Service
- Thermex - Vi designar och utvecklar köksfläktar
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>