ROVSUN 110LBS 24H Commercial Ice Maker Machine User Guide

June 16, 2024
ROVSUN

ROVSUN-LOGOROVSUN 110LBS 24H Commercial Ice Maker Machine

Common malfunction analysis

Specifications

Error Code Symptom Possible Cause Solution
E1
  • The ice full indicator is on, and the proximity switch didn’t react
  • Normal to make ice
  • No water in the tank
  • Water in the tank

|

  • The evaporator connector didn’t assemble well
  • The proximity switch is not sensitive
  • The connector didn’t return to its original position
  • Stop every 4 cycles, and the process of ice drop continued for 5 min
  • The water tank is not plugged
  • Use tap water as a water source

|

  • Re-install the connector
  • Replace the switch
  • Take away the ice to make the connector return to its original position
  • The proximity switch is not sensitive, replace it
  • Put the plug back
  • Check the water supply

E2|

  • No water in the tank
  • Water in the tank
  • Water flow and water get cool

|

  • Use tap water as a water source
  • Thin ice on the evaporator
  • Very solid ice on the evaporator
  • Some water sprayed onto the ice storage tank
  • The water leak from the back of the water tank
  • The main board didn’t supply electricity to the compressor
  • The compressor didn’t work
  • The compressor is very hot
  • Compressor work but the connected copper pipe didn’t get cool

|

  • The pump is badly clogged up, replace or clean it
  • Reduce the making time through “-“
  • Adjust the spray pipe
  • The tank needs to be adjusted
  • Replace by a new main board
  • Check the starter, and replace it with a new one if needed
  • Replace
  • The compressor leak

E3| The fan is not work|

  • The condenser prob is not sensitive
  • The fan is jammed
  • Fan is broken

|

  • Unplug the prob or replace it with a new one
  • Adjust the fan
  • Replace

E4| Ice full| The connector didn’t return to its original position| Take away the ice to make the connector return to its original position

FAQ

  • What should I do if the ice full indicator is on but the proximity switch doesn’t react?
  • Check if the evaporator connector is assembled well and if the proximity switch is sensitive. You might need to re-install the connector or replace the switch.
  • How can I troubleshoot when there’s no water in the ice machine tank?
  • Ensure that the water tank is plugged correctly and check the water supply. If the pump is clogged, it may need cleaning or replacement.
  • What steps should be taken if the ice machine is making thin ice?
  • Adjust the making time through “-” to reduce it, and check if the spray pipe needs adjusting.
  • What can be done if the compressor is not cooling despite working?
  • This could indicate a compressor leak. It’s necessary to check for leaks and possibly replace the compressor.
  • If the fan in the ice machine is not working, what could be the issue?
  • The problem could be due to a non-sensitive condenser probe, a jammed fan, or a broken fan. Depending on the cause, you may need to unplug or replace the probe and adjust or replace the fan.

Common malfunction analysis




El

| ****

Ice fu ll indica to r i s o , n a n d proximity switch didn’t react

| The evaporator connector didn’t

assemble well

| ****

Re-install the connector

---|---|---|---
The proximity switch is not sensitive| Replace the switch
The connector didn’t return to its original position| Take away the ice to make the connector return to its original position








E2

| ****

Normal to make ice

| Stop every 4 cycles, and the process of ice drop continues for 5 min| ****

Prox mi ty switch is

not sensitive, replace it



No water in the tank

| The water tank is not plugged| Put the plug back
Use tap water as a water source| Check the water supply


Use tap water as a water source

| The water pressure is too high, water float

can’t work. Adjust the water pressure or replace it with a new one.


Water in the tank

| ****

No water or low flow

| The pump is badly clogged up, replace or clean
The spray pipe is clogged up, clean it










E2

| ****



Water flow and water get cool

| Thin ice on the evaporator| Increase the making time through “+”
very solid ice on the evaporator| Reduce the making time through”-“
Some water sprayed on an ice storage tank| ****

Adjust the spray pipe

The water leak from the back of the water tank| ****

The tank needs to be adjusted.




Water flows down but the water is not cool

| The main board doesn’t supply

electricity to comp resistor

| ****

Replace by a new main bo ard


Compressordidn’t work

| Check the starter, and replace a new one if needed
The compressor is very hot| Replace
Compressor work but the

connected copper pipe didn’t get cool

| ****

The compressor leak



E3

| ****

The fan is not work

| The condenser prob is not

sensitive

| Unplug the prob or replace a new

one

The fan is jammed| Adjust the fan
Fan is broken| Replace with a new fan


E4

| ****

Ice full

| The connector didn’t return to its original position| Take away the ice to make the connector return to its original position

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals