Kiddieware THER002 Infrared Thermometer Forehead And Ear User Manual

June 16, 2024
Kiddieware

Infrared
The rmometer
Forehead & Ear

User Manual

THANK YOU!
For choosing our product. We appreciate your trust in our brand KIDDIEWARE”, and we will do our best to meet your expectations.
As parents of two little children under 4 years old, we have created “KIODIEWARE
with ONE goal in mind, to provide products that will help us, as parents to enjoy and make it the easiest possible to take care of our little Bundles with Love.
Customer satisfaction is our top priority. IF you have any questions or concerns please do not hesitate to contact us at:
Email: Info@kiddieware.com Or SMS to: 1929-249-0722 We won’t stop until your issue is resolved and you are 100% satisfied.
Best Regards: Emma, Founder of Kiddieware

|
---|---

19292490722 Hi, I need help.

| info@kiddieware.com

Introduction:

Thank you for purchasing this Forehead & Ear Infrared Thermometer.
Please read the Operating Manual carefully before using the thermometer, and put it in a safe and secure place for reference.

Foreword:

The infrared thermometer can be used to read the body temperature by measuring the ear or forehead temperature, which is suitable for adults and children (ear test mode only for the child above 3 months).

Package Contents

No. Name Quantity
1 Infrared Thermometer 1
2 Pouch 1
3 Operating Manual 1
4 Quick Start Guide 1
5 AAA Battery 2

Model: THER002
Issuing Date : 08/19/2021

WARNINGS AND PRECAUTIONS

  1. Keep out of reach of children under 12 years.

  2. Never immerse the thermometer into water or other liquids (not waterproof). For cleaning and disinfecting, please follow the instructions in the “Care and cleaning” section.

  3. Never use the thermometer for purposes other than those it has been intended for. Please follow the general safety precautions when using on children.

  4. Keep the thermometer away from direct exposure to the sun and keep it in a dust- free, dry area, well-ventilated place at a temperature between 5ºC ( 41 ºF ) – 40ºC ( 104ºF ) .

  5. Do not use the thermometer in high humidity environments. (>95% RH) Do not use the thermometer if there are signs of damage on the measuring sensor or on the instrument itself. If damaged, do not attempt to repair the instrument! Please contact the dealer.

  6. This thermometer consists of high-quality precision parts. Do not drop the instrument. Protect it from severe impact and shock. Do not twist the instrument or the measuring sensor.

  7. Please consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, shivering, stiff neck, pain when urinating, etc., even in the absence of fever.

  8. Even in the absence of fever, those who exhibit a normal temperature may still need to receive medical attention. People who are on antibiotics, analge sics, or antipyretics should not be assessed solely on temperature readings to determine the severity of their illness.

  9. Temperature elevation may signal a serious illness, especially in adults who are old, frail, have a weakened immune system, or neonates and infants. Please seek professional advice immediately when there is a temperature elevation and if you are taking temperature for whom are:
    • Over 60 years of age (Fever may be blunted or even absent in elderly patients)
    • Having diabetes mellitus or a weakened immune system (e.g., HIV positive, cancer, chemotherapy, chronic steroid treatment, splenectomy)
    • Bedridden (e.g., nursing home patient, stroke, chronic illness)
    • A transplant patient (e.g., liver, heart, lung, kidney)

  10. This thermometer is not intended for preterm babies or small-for-gestational age babies. This thermomter is not intended to interpret hypothermic temperatures. Do not allow children to take their temperatures unattended.

  11. Use of this thermometer is not intended as a substitute for consultation with your physician or pediatrician.

  12. Clean the thermometer probe after each use.

  13. Do not use the thermometer on newborns or for continuous temperature  monitoring purposes.

  14. Do not take a measurement while or immediately after nursing a baby.

  15. Patients should not drink, eat, or be physically active before/while taking the measurement.

Product Description

  1. Overview
    Infrared Thermometer measures the body temperature based on the infrared energy emitted from the eardrum or the forehead. Users can quickly get measurement results after positioning properly the temperature probe in the ear canal or forehead. Normal body temperature is a range. The following tables shows that this normal range also varies by site. Therefore, readings from different site should not be directly compared. Tell your doctor what type of thermometer you used to take your temperature and on what part of the body. Also bear this in mind if you are diagnosing yourself.Measuring part| Normal temperature range
    ---|---
    Forehead temperature|  36.1°C – 37.5°C (97°F -99.5°F)
    Ear temperature|  35.8°C – 38°C (96.4°F – 100.4°F)
    Oral temperature| 35.5°C – 37.5°C (95.9°F – 99.5°F)
    Rectal temperature| 36.6°C – 38°C (97.9°F -100.4°F)
    Axillary temperature| 34.7°C – 37.3°C (94.5°F – 99.1°F)

  2. Structure
    The device consists of enclosure, button, a temperature sensor, Infrared temperature-measuring element, microcomputer controlled circuit, LCD, backlight and a buzzer.

  3. Operating principle
    In the nature, for all objects whose temperature is higher than the absolute zero (-273.15℃), for the sake of molecule’ s thermal motion, radiate electromagnetic wave to the surrounding ambient including the infrared wave without a break, the relationship between the density of radiation energy with the object’ s tempera- ture conform to the radiation law. The infrared thermometer’ s working principle is based on the fourth-power law: infer objects’ radiation temperature by measuring objects’ radiation infrared energy. Thermopile sensor can convert the infrared energy into thermoelectricity, and output as a detected signal after signal processing.

The infrared temperature sensor detects infrared energy emitted by the eardrum. A built-in lens focuses the collected energy, which is then converted into a temperature reading by the thermopiles and measurement circuits.
Kiddieware THER002 Infrared Thermometer Forehead And Ear -
Probe

  1. Indications for use
    The infrared thermometers take human body temperature via the eardrum or forehead. The forehead mode is indicated for people of all ages and the eardrum mode is indicated for people above three months old. It applies to both professional use and home use.

  2. Contraindications
    Do not use the thermometer if the ear is infected with otitis or suppuration.

Features

  • One button design realizes the measurement of forehead, ear
  • AMS™ technology (Patented): automatic mode switch between forehead & ear mode
  • Magnetic probe cover makes more convenient to use
  • With super large screen display current and previous readings
  • Multi-functional, can measure ear, forehead
  • 40 sets of memories, switching between mute and un-mute mode
  • Audio and visual fever warning
  • Switching between ºC and ºF
  • Auto shut-down and power-saving
  • LCD four color backlight temperature indication

Product Structure

  1. LCD display screen
  2.  Measure Button
  3.  Probe cover (take it off when measuring ear temperature)
  4. Probe
  5. Battery cover

Display description

  1. Forehead mode
  2. Ear mode
  3. Adjust mode
  4. Fahrenheit / Celsius degrees
  5. Previous temperature value
  6. Low battery indication
  7.  Mute /Un-mute icon
  8. Current temperature value

How to use your thermometer

  1.   In order to avoid the inaccuracy:
  1. Please make sure that the device will be used in the room only, and there is no strongly conversation ofwind.
  2. Please make sure that there is no intense emotion and movement before measuring.
  3. If the device is transferred from one condition to another, which has different ambient temperature, it is suggested to deposit for more than 30 minutes.
  4. If the tester is transferred from one condition to another, which has different ambient temperature, it is suggested to have a rest for more than 10 minutes.
  5. Do not hold the device for a long time, as it is highly sensitive to heat.
    The device has undergone clinical test, it is safe and accurate when using in accordance with operation manual.
  1. Take your forehead temperature
    1) When using the thermometer for the first time, please load the batteries.
  1. Press and release the Measure Button in one second to power on.
  2. Then point the temperature probe at the center of the forehead, with a distance of 0-3 cm(0-1.18 inches).
  3. Press and release the Measure Button in 1 second.
    The beep is heard, you can now read the value.

NOTE: The forehead measurement is an indicative reading. The measured forehead temperature can fluctuate up to 1 ºF/0.5 ºC from your actual body temperature. Please be aware of the factors that influence the accuracy as described in the section “Temperature taking tips” and “WARNINGS AND PRECAUTIONS” .
If the eyebrow area is covered with hair, sweat or dirt, please clean the area beforehand to improve the reading accuracy.
Always check if the lens is clean.
Always make sure the user and the thermometer will have been in the same room for at least 30 minutes prior to the measurement.

  1. Take your ear temperature
    1) Press the Measure Button to power on.
  1. Take off the probe cover.
  2. Then fit the probe snuggly into the ear canal.
    Press and release the Measure Button in 1 second, the beep is heard, you can now read the value.
    Kiddieware THER002 Infrared Thermometer Forehead And Ear -
Thermocouple1
    Please make sure that the ear is clean, with no earwax or obstructions.
    The right ear reading may differ from the reading taken at the left ear. Therefore, always take the temperature in the same ear.
    Kiddieware THER002 Infrared Thermometer Forehead And Ear -
Thermocouple2
    Note:
    Children under 1 year: Pull the ear straight back.
    Children aged 1 year to adult: Pull the ear up and
    Do not force the thermometer into the ear canal.
    Otherwise, the ear canal may get injured.
    When taking the temperature on an adult, gently pull the ear up and back to make sure the ear canal is straight, so that the temperature probe can receive an infrared ray from the eardrum.
    Be careful when taking temperature on a child, whose ear canal is small.
  1. After a measurement
    Once the reading has been completed, remove the thermometer away from the forehead/ear and observe temperature.
    After each measurement, you can enter the recall mode and query earlier temperature readings.
    Do not hold the thermometer for a long time, because it is sensitive to the ambient temperature.
    After each measurement, clean the temperature probe with a soft cloth, and put the thermometer in a dry and well-ventilated place.
    You should wait at least 10 seconds between each measurement.
    It is dangerous to make a self-diagnosis or self-treatment based on the obtained measurement results. For such purposes, please consult a doctor.

  2. Read your temperature
    T indicates a temperature reading.
    1) In forehead or ear mode.
    If 32ºC ≦ T ≦ 37.5ºC (89.6ºF ≦ T ≦ 99.5ºF), the green light will be displayed, with one long beep.
    If 37.6ºC ≦ T ≦ 38.0ºC (99.7° F≦ T≦100.4°F), the orange light will be displayed with 6 short beeps, which is a warning that you may have a low fever.
    If 38.1ºC ≦ T ≦ 42.9ºC (100.6° F≦ T≦109.2°F),the red light will be displayed with 6 short beeps,which is a warning that you may have a high fever.
    2) In adjust mode.
    If 0ºC ≦ T≦ 100ºC (32.0ºF≦ T ≦ 199.0ºF), the white light will be displayed with one long beep.

  3. Switching between mute and un-mute
    When the thermometer is turned on, keep pressing the Measure Button for 5 seconds, to switch from un-mute to mute.
    Kiddieware THER002 Infrared Thermometer Forehead And Ear - toggle
switch

  4. Checking 40 sets of memory data
    When the thermometer is turned on, keep pressing the Measure Button for 2 seconds and release once you see “MEM” on the screen, press this button again to check the 40 sets of memories one by one. If no value, it will display “—”

  5. °C / ° F conversion
    Open the battery cover, use the toggle switch to change the ºC/ºF.

  6. Automatically turn off
    The unit will shut down automatically after 13 seconds of no use.
    Caution
    All memory records will be lost when uninstall or reinstall the battery.

  7. Replace the battery.
    Put two AAA batteries correctly into the compartment.
    Remove the batteries if the thermometer will not be used for more than two months.

Temperature taking tips

  1.  It is important to know each individual’ s normal temperature when they are well. This is the only way to accurately diagnose a fever. Record readings twice a day (early morning and late afternoon). Take the average of the two temperatures to calculate normal
    oral equivalent temperature. Always take the temperature in the same location, since the temperature readings may vary from different locations on the forehead.

  2. Achild’ s normal temperature can be as high as 99.9°F ( 37.7°C ) or as low as 97.0°F ( 36.1°C ). Please note that this unit reads 0.5°C (0.9°F) lower than a rectal digital thermometer.

  3. External factors may influence ear temperatures, including when an individual has:
    • been lying on one ear or the other
    • had their ears covered
    • been exposed to very hot or very cold temperatures
    • been recently swimming or bathing
    In these cases, remove the individual from the situation and wait 20 minutes prior to taking a temperature.
    Use the untreated ear if prescription ear drops or other ear medications have been placed in the ear canal.

  4. Holding the thermometer for too long in the hand before taking a measurement can cause the device to warm up. This means the measurement could be incorrect.

  5.  Patients and the thermometer should stay in steady-state room condition for at least 30 minutes.

  6. Before placing the thermometer sensor onto the forehead, remove dirt, hair, or sweat from the forehead area. Wait 10 minutes after cleaning before taking measurement.

  7. Use an alcohol swab to carefully clean the sensor and wait for 5 minutes before taking a measure- ment on another patient. Wiping the forehead with a warm or cool cloth may impact your reading. It is advised to wait 10 minutes before taking a reading.

  8.  In the following situations it is recommended that 3-5 measurements in the same location be taken and the highest one taken as the reading:
    •  Newborn infants in the first 100 days.
    •  Children under three years of age with a compromised immune system and for whom the presence or absence of fever is critical.
    •  When the user is learning how to use the thermometer for the first time until he/she has familiarized himself/herself with the instrument and obtains consistent readings.

Care and cleaning

Use an alcohol swab or cotton swab moistened with 70% alcohol to clean the thermometer casing and the measuring probe. After the alcohol has completely dried out, you can take a new measurement.
Ensure that no liquid enters the interior of the thermometer. Never use abrasive cleaning agents, thinners or benzene for cleaning and never immerse the instrument in water or other cleaning liquids. Take care not to scratch the surface of the LCD screen.

Error and Troubleshooting

Symptom Possible Cause Description & Solution

Failed to power on

| The battery level is too low.| Replace with a new battery
Polarities of the batteries are reversed.| Ensure the batteries are in the right position
The thermometer is damaged| Contact dealer
The reading is too low| The lens of the probe is dirty.| Clean the lens with a cotton swab.
The distance of the item and target is too far| Keep in  contact  with  skin, or put the probe into the Ear Canal.
You have just come from a cold environment| Stay in a warmer room for at least 30 minutes before taking a reading
The reading is too high| You have just come from a hot environment.| Stay in an adequately  cool  room for at least 30 minutes  before taking a reading
| The ambient temperature is not in range.| One long beep, and red backlit for 3 seconds. Take a measurement under an ambient temperature between 0°C (32.0°F) and 40°C (104°F).
| Memory error or calibra- tion is not finished. Item will be turned off autom- atically after 3 seconds.| One long beep, and red backlit for 3 seconds. Contact dealer.
Symptom| Possible Cause| Description & Solution
---|---|---
| In ear or forehead mode, T>42.9°C(109.2°F)
In adjust mode, T>100°C ( 199°F)| One long beep, the screen will be displayed in red.
| In ear or forehead mode, T<32°C(89.6ºF)
In adjust mode, T<0°C (32°F)| One long beep, the screen will be displayed in red.
| The power voltage is between 2.4V-2.7V| The battery icon will flicker, it means the battery is low, but you still can use the thermometer.
| The power voltage is lower than 2.4V| The battery icon will flicker, the item will be turned off automatically after 3seconds. Please replace with a new battery

Technical Specifications:

Product name Forehead & Ear Infrared Thermometer
Applicable regulations and laws ASTM E 1965-98

ISO80601-2-56

Display

| Segment LCD, Four color LED backlight (white, green, orange, red)
Temperature units| °C / °F, switchable
Power supply| DC 3V, AAAX2

Measurement range

| Measurement: 32.0°C–42.9°C ( 89.6ºF–109.2°F)
Direct : 0°C–100°C (32°F–199°F)
Accuracy (Laboratory)| Measurement mode| ±0.2°C /±0.4 ° F
Direct mode| ±1.0°C / 2.0°F
Display resolution| 0.1ºC / °F
---|---
Automatic shutdown| 13s±1s
Memory| 40 groups of measured temperature.
Operational conditions| Temperature:5°C-40°C(41°F-104°F) Humidity: 15-95%RH, non-condensing Atmospheric pressure:70-106kPa

Storage condition

| Ambient Temperature: -20°C-55°C(-4°F-131°F) Relative Humidity: 0-95% RH, non-condensing Atmospheric pressure: 50kPa to 106kPa
Battery| 2*AAA, can be used for more than 3000 times
Weight & Dimension| 73g (without battery), 163.5x40x41mm

Symbols: **

**

Symbol Description
Type BF applied part.
**** Information about a manufacturer.
**** Please read the instructions carefully.
**** Waste electrical materials should be sent to a dedicated collection

point for recycling.

SN

| Serial number

LOT

| Batch number
**| IMPORTANT** Inaccurate reading or thermometer damage may occur if the thermometer is not correctly used.

**** IP22

| 2 Protected against solid foreign objects of 12,5 mm Ø and greater
2 If keep the thermometer in 15 degree angle, it still can prevent the water drop.
| CE marking
****| Authorized Representative In The European Community


| **** keep away from sunlight
---|---


| **** Fragile, handle with care


| **** Keep dry


| **** This way up

Appendix: EMC information-Guidance and manufacturer’ s declarations

CAUTION:

  • The Infrared Thermometer needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided for in the ACCOMPANYING DOCUMENTS.
  • Portable and mobile RF communications equipment can affect Infrared Thermometer
  • The Infrared Thermometer should not be used adjacent to or stacked with other equipment. Guidance and manufacturer´s declaration – electromagnetic emission –for all EQUIPMENT AND SYSTEMS

Electtromagnetic Emissions

Guidance and manufacturer’s statement – Electromagnetic emission

The Infrared Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the Infrared Thermometer should assure that it is used in such an environment.
Emission  test| Compliance
RF emissions CISPR 11| Group 1
RF emissions CISPR 11| Class B
---|---
Harmonic emissions I EC 61000-3-2| Not applicable
Voltage fluctuations/ flicker emissions IEC 61000-3-3| Not applicable

Electtromagnetic Immunity

Guidance and manufacturer’s declaration – Electromagnetic Immunity

The Infrared Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the Infrared Thermometer should assure that it is used in such an environment.
Immunity Test| IEC 60601-1-2
Test level| Compliance level
Electrostatic discharge (ESD)
IEC 61000-4-2| ±8 kV contact
±2 kV, ±4 kV, ±8 kV, ± 15 kV air| ±8 kV contact
±2 kV, ±4 kV, ±8 kV, ±15 kV air
Electrical fast transient/burst
IEC 61000-4-4| Not applicable| Not applicable
Surge
IEC 61000-4-5| Not applicable| Not applicable
Voltage dips, short
interruptions and voltage
variations on power
supply input lines
IEC 61000-4-11| Not applicable| Not applicable
Power frequency magnetic field
IEC 61000-4-8| 30 A/m
50Hz/60Hz| 30 A/m
50Hz/60Hz
Conducted RF
IEC61000-4-6| Not applicable| Not applicable
Radiated RF
IEC61000-4-3| 10 V/m
80 MHz – 2,7 GHz
800/0AM at 1 kHz| 10 V/m
80 MHz – 2,7 GHz
80 0/0AM at 1 kHz
NOTE UT is the a.c. mians voltage prior to application of the test level.

Electro magnetic Immunity

Guidance and manufacturer’s declaration – Electromagnetic Immunity

The Infrared Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the Infrared Thermometer should assure that it is used in such an environment.
Radiated RI
IEC61000-4.3
(Test
specifications
for ENCLOSURE
PORT IMMUNITY
to RI wireless
communications
equipment)| Test
Frequency
(MHz)| Band
(MHz)| Service| Modulation| Maximum Power (W)| Distance
(1))| IEC 60601-1-2
Test Level
(V/m)| Compliance level
(Wm)
---|---|---|---|---|---|---|---|---
385| 380-390| 400| Pulse
ulse
modulation
18 Hz| 2.| 0.3| 27| 27
400| 430-470| GMRS 460
FRS 460| F
M ± 5 kHz deviationl kHz
sine| 2| 0.3| 28| 28
10| 704 – 787| LTE Band
13,17| Pulse
modulation
217 Hz| 0.2| 0.3| 9| 9
745
780
810| 800 – 080| GSM
800/900,
TETRA 800,
iDEN 820,
COMA 850,
LTE Band 5| Pulse
modulation
18 Hz| 2| 0.3| 28| 28
870
930
810| 1700-1990
GSM 1800;| CDMA 1900;GSM 1900;
DECT;
LTE Band
1, 3,4, 25;
UMTS| Pulse
modulation
217 Hz| 2| 0.3| 28| 28
870
930
2450| 2400-2570| Bluetooth,
WLAN,
802.11
b/g/n,
RFID 2450,| Pulse
modulation
217 Hz| 2| 0.3| 28| 28
| :450| 2400-2570| Bluetooth,
WLAN,
802.11
b/g/n,
RFID 2450,| Pulse
modulation
217 Hz| 2| 0.3| 28| 28
| | LTE Band 7| | | | |
810| 5100-5800| WLAN
802.11a/n| Pulse
modulation
217 Hz| 0.2| 0.3| 9| 9
870
930

Warranty and After-Sale Service

The device is under warranty for 12 months from the date of purchase.
The batteries, the packaging, and any damage caused by improper use are not covered by the warranty.
Excluding the following user-caused failures:

  1. Failure resulting from unauthorized disassembly and modification.
  2. Failure resulting from an unexpected dropping during application or transportation.
  3. Failure resulting from not following the instructions in theoperating manual.

Brand: Kiddieware
Add: Brooklyn, NY 11211
Email: info@kiddieware.com
Tel: 1929-249-0722

Shenzhen AOJ Medical Technology Co., Ltd.
Add: Room 301&4F, Block A, Building A, Jingfa Intelligent
Manufacturing Park, Xiaweiyuan, Gushu Community,
Xixiang Street, Bao’an District, 518126 Shenzhen, CHINA
Email: info@aojmedical.com
Website: www.aojmedical.com
Tel: 86-755-2778 6026
Made in China
Share Info GmbH
Address: Heerdter Lohweg 83, 40549 Düsseldorf, GERMANY
Tel: 0049 179 5666 508
E-mail: EU-Rep@share-info.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals