Nordic Comfort SY-06-OC Ice Bath Chiller User Manual

June 16, 2024
Nordic Comfort

Nordic Comfort SY-06-OC Ice Bath Chiller User Manual
Nordic Comfort SY-06-OC Ice Bath Chiller

CAUTION – (Possible injury or property damage)

  • Do not install the chiller in closets, cabinets, or other small places.
  • Never cover the intake or exhaust openings with clothes, towels, or other objects.
  • Use extreme caution when operating near children, the elderly or infirm.
  • Never insert fingers or foreign objects into the ventilation grilles or other parts of the chiller.
  • Do not place heavy objects on the power cord or run it under carpets or rugs.
  • Do not climb, sit, or stand on the chiller, or place objects on top of it.
  • The operators of the chiller must be at least 18 years old.

Note: At present, Tuya can only support 2.4G WiFi signal. Therefore, before connecting the phone to the chiller, please confirm that the WiFi used by your phone is in the 2.4G frequency band. It will not be able to connect to the chiller, If it is in the 5G frequency band.

  • Smart Life

  • Tuya Smart

Product Overview

Product Overview
Product Overview

Accessories(For SY-06-OC/SY-06-HC)

  • Plastic Wrench

  • Filter Elements

  • Water Pipes

  • ( Inner Teeth 3/4” )
    ( Outer Teeth 1/2” )
    Quick Conectors

  • Screwdriver

  • Rubber Seals

  • Warning Label

  • Operation Label

  • User Manual
    Accessories

Product Overview
Product Overview

  • Plastic Wrench

  • Filter Elements

  • Water Pipes

  • ( Inner Teeth 3/4” )
    ( Outer Teeth 1/2” )
    Quick Conectors

  • Screwdriver

  • Rubber Seals

  • Warning Label

  • Operation Label

  • User Manual
    Accessories

SPECIFICATIONS

Product Overview

Model No.| SY-06-HC (cooling+heating)
SY-06-0C (cooling)| SY-08-HC (cooling+heating)
SY-08-OC (cooling)| SY-10-HC (coolIng+heating)
SY-10-0C (cooling)| SY-20-HC (cooling+heating)
SY-20-0C (cooling )
---|---|---|---|---
Power Supply| AC100-127V                    AC220-240V           AC100-127V AC220-240V            AC100-127V AC220.240V            AC100-127V60Hz                             50/60Hz 60Hz                  50/60Hz                  60Hz 50/60Hz              60Hz| AC220-240V
50/60Hz
Input Power| 640W                            610W                  725W 710W            1170W                1150W                1500W 1950W
Compressor Power| 505W                            480W             630W 605W             945W             900W            1260W 1760W
Cooling Capacity| 1520W                        1450W                1790W 1770W               3050W            2900W                3600W 5750W
Heating Function| Optional
Cooling Function| Yes
Refrigerant| R410A
Water Temp.| 3-42•C / 42-3°C
Disinfection| Built-in ozone disinfection device
Circulation Pump| Built-in Self-priming System
Water Filter| Installed External
WIFI Remote Control| APP in Android & IOS system
Transport Wheels| Yes
Carry Handle| Yes
Quick Connectors| Yes
AC Plug| US, UK, EU, AU, SA, TH, IT
Net Weight| 30kgs| 35kgs| 40kgs| I                45kgs
Dimension| 143•W33•H48cm          I| L47•W35•HS3cm| I  L54•W40•H5Scm
Certification| CE
Water Volume&
Cooling Time
(23°C to 5t)
For reference only| 50151.5H            SOL51.9H           SOL50.8H 50Ls1.2H 2001_52.8H    200153.1H             2001.52.5H 200152.0H   1001S3.1H       100153.5H         100LS1.7H       100152.1H 5001.26.5H        5001.26.9H        5001.24.6H 5001.24.1H   2001.25.2H      200L25.6H         200123.9H      200124.2H
Above datas based on testing in closed insulated barrel, 30•C room temperature
Main Features| Excellent design with low noise| Overloading protection
Built-in self-priming circulating Pump| With Anti-freeze System
Water and electricity separating system.| Overheating Protection
Leakage Protection System for Electricity| Max. Cooling Capacity in Specified Spaces
Built-in OZONE disinfection device, and external water filter| Suitable For Indoor and Outdoor Cooling and Heating
WIN Connection Remote Control by 105 & Android System| Excellent value, priced to be as affordable as possible
Easy to Install including hoses with quick connectors| High-definition 5″ TFT touch panel with adjustable brightness
Automatic on/off and Constant Temperature System| The detailed fault prompt function helps you to solve the fault quickly

Touch Panel Introduction

Status Icons
Status Icons
The corresponding icon will only light up when the current function is turned on.

  1. Turn on/off
  2. Press to enter the second screen
  3. Press 3-5s to lock or unlock
  4. Press + or – to set the temp
  5. It will be displayed when there is a failure
  6. Displays the current water flow

Remarks: 10 11 will only light up for chillers with heating function when heating.

Product Overview

Touch Panel Introduction

  1. Adjust the Ozone working time interval: 0 min (close) and max to 5 min
  2. Adjust the screen brightness: min 10%, max 100%
  3. Adjust the screen sleep time: 0 min (close), max 5 min
  4. Adjust the screen lock time: 0 min (close), max 5 min
  5. Click return button to enter the first interface
  6. Long press to enter the WiFi function ( connect Tuya or Smart Life)
  7. Click the help Icon to scan the QR code for technical support 
  8. Temperature unit switching(℃/℉)
  9. Adjust the button sound: ON/OFF
  10. Power-on automatic operation ON/OFF

Product Overview

WiFi Discription

  1. Turn on the chiller.

  2. Click the settings key.

  3. Press WiFi key for 3-5 seconds until the WiFi blinks.

  4. Open the Tuya Smart App on your phone.
    WiFi Discription

  5. Select add device.
    WiFi Discription

  6. Turn on your phone’s WiFi connection and enter password.
    WiFi Discription

  7. Succeeded in adding a link, Enter the App control panel.
    WiFi Discription

Tuya Smart Interface Introductions

  1. Turn on/off(Turn ON/OFF the chiller)
  2. Locking (Touch panel lock/unlock)
  3. Temperature unit switching (℃/℉)
  4. Water Flow
  5. Set Time
  6. Touch screen prompt sound (ON/OFF)
  7. Power-on automatic operation ON/OFF
  8. Water Switch1
  9. Water Switch2
  10. Adjust the Ozone working time interval: 0 min (close) and max to 5 min
  11. Temperature adjustment (3-42°C/37-107°F)
  12. Current Temperature
    Product Overview

Precautions

  1. Do not block the fan outlet of the room. Otherwise, it will reduce the heating and cooling effect and waste power
  2. It is forbidden that the equipment is not clean. Regularly check and clean the equipment and filtering device
  3. It is forbidden to touch the fan during the operation of the equipment to avoid hurting fingers
  4. Pay attention to whether the rated voltage of the product is consistent with the power supply voltage of the home
  5. During the operation of the equipment, it is not allowed to touch the switch with hands, let alone the electrical components

CAUTIONS:

  • Do not turn the chiller upside down.
  • Do not use without filter element installed
  • Make sure there is more 100cm free space around the chiller
  • Working Temperature: 1 C~45 C
  • Storage Temperature: -20 C~55 C
  • Strorage Relative Humidity: 20%~85%
    (Make sure that there is no water in the internal pipeline of the chiller)