PHILIPS WL346W Air Breathe Healthy Instruction Manual

June 16, 2024
Philips

PHILIPS WL346W Air Breathe Healthy Instruction Manual
PHILIPS WL346W Air Breathe Healthy

UV-C disinfection upper air wall mounted
As part of the Philips UV-C disinfection upper-air device series, the Philips UV-C disinfection upper-air wall-mounted device is designed to be installed on walls for the disinfection of air in a wide range of applications. Optimised for low ceiling heights, the UV-C rays are distributed at device level and above. The beam of UV-C rays is controlled by specific reflectors and the louvre design. This allows for the disinfection of the air in a space, while ensuring that day-to-day business activities can continue underneath the area where the device is active.

Benefits

  • Our Philips UV-C disinfection upper-air wall-mount luminaires inactivated 99.99% of SARS-COV-2, the virus responsible for the COVID-19 disease, in the air of a room within 10 minutes. At 20 minutes, the virus was below detectable levels. [1]
  • Swift disinfection effect, with 83.6% reduction of SARS-CoV-2, the virus that causes the COVID-19 disease, achieved in a room within 2 minutes. [1]
  • Allows quiet disinfection of air while business activity continues beneath the level of the device
  • Uses Philips UV-C lamps and drivers
  • Environmentally friendly – no ozone emissions during or after use

Features

  • Philips T5 TUV 25 W lamp included
  • Shortwave UV radiation peak at 253.7 nm (UV-C)
  • The louvres and reflector control the distribution of UV-C at the device level and above, where people are not usually present
  • Wall-mounted installation
  • Complies with IEC 62471 standard for photobiological safety

Application

  • Office
  • Retail
  • Food outlets
  • Hospitality
  • Schools
  • Banking
  • Washrooms

Warnings and Safety

  • DANGER: Risk Group 3 UV product. Like any disinfection system, UV-C lamps and devices must be installed and used in the correct way. Direct exposure to UV-C can be dangerous and result in a sunburn-like reaction to the skin and serious damage to the cornea. As UV-C is invisible to the eye, the UV-C upper air device must be installed together with adequate safeguards to ensure that the UV-C upper air device can be operated in a safe way. The UV-C upper air device are only to be used as components in a system that consists of adequate safety safeguards such as, but not limited to, those indicated in the mounting instructions and/or user manuals. Direct exposure to UV-C is dangerous. Philips UV-C luminaires systems must only be sold through qualified partners and installed by professionals according to our stringent safety and legal requirements. Our UV-C products are not meant to be used in applications or activities which may cause and/or lead to death, personal injury and/or damage to the environment.
  • [1] According to results obtained from a laboratory test conducted by Innovative Bioanalysis, a CAP, CLIA, AABB Certified Safety Reference Laboratory, in a room with sufficient air circulation. For more information, please refer to the test report available in the & quota ; related tools & quota; part of this webpage

Versions

UV-C disinfection upper air Wall mounted version high output

UV-C disinfection upper air Wall mounted version

Dimensional drawing

Dimensional drawing

Product details

Access to lamp and product maintenance
Product details
Wall mounting plate and indicator light
Product details

General Information

CE mark Yes
ENEC mark
Flammability mark
Gear HF-S
Glow-wire test Temperature 650 °C, duration 30 s
Number of gear units Unit
Product family code WL345W
EU Rosh compliant Yes
Warranty period 1 years

Light Technical

Number of light sources 1
Optic type Lamellae louvre

Operating and Electrical

Cable

Connection| Push-in connector 3-pole
Inrush current| 18 A
Inrush time| 0.35 ms
Input Voltage| 230 V
Number of products on MCB of 16 A type B| 28
Power Factor (Fraction)| 0.98

Temperature

Ambient temperature range: +10 to +40 °C

Controls and Dimming

Dimmable: No

Mechanical and Housing

Housing Color White and black
Housing material Aluminum
Optic material Aluminum
Reflector material Aluminum
Overall height 140 mm

Approval and Application

Protection class IEC Safety class I
Mech. impact protection code IK02
Ingress protection code IP20

Initial Performance (IEC Compliant)

Power consumption tolerance: +/-10%

Application Conditions

Suitable for random switching: No

UV

Order Code Full Product Name| UV-C irradiance defined at 0.2 m| UV-C irradiance defined at 2 m| UV-C radiation
---|---|---|---
66504700 WL346W 1xTUV T5 25W HFS| 8,060 mW/m²| 972 mW/m²| 0.53 W
90445900 WL345W 1xTUV T5 25W HFS| 4,266 mW/m²| 356 mW/m²| 0.375 W

© 2023 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The
information presented in this document is not intended as any commercial o…er and does not form part of any
quotation or contract, unless otherwise agreed by Signify. All trademarks are owned by Signify Holding or their
respective owners.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals