UK – DECLARATION OF CONFORMITY
Declaration of Conformity
We
SIP (Industrial Products) LtdGelders Hall Road Shepshed Loughborough Leicestershire LE12 9NH England
As the manufacturer within the UK, England, Scotland & Wales, declare that the
EP2M Water Pump – SIP Part. No. 07614
Conforms to the requirements of the following directive(s), as indicated.
Supply of machinery (Safety) Regulations 2008 Electromagnetic Compatibility Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
And the relevant harmonised standard(s), including
- BS EN 60335-1:2012+A11+A13+A1+A14+A2
- BS EN60335-2-41:2003+A1+A2
- BS EN 62233:2008
- BS EN 55014-1:2017
- BS EN 55014-2:1997+A1+A2 BS EN 55014-2:2015
- BS EN 61000-3-2:2014
- BS EN IEC 61000-3-2:2019 BS EN 61000-3-3:2013
- BS EN 61000-3-3:2013+A1
Signed:
Mr P. Ippaso – Director – SIP (Industrial Products) Ltd
Date: 19/08/2021
EU – DECLARATION OF CONFORMITY
Declaration of Conformity
We
SIP (Machinery Europe) Ltd
ASM Chartered Accountants
First Floor Block One
Quayside Business Park
Dundalk
County Louth
Republic of Ireland
As the manufacturer’s authorised representative within the EC declare that th
EP2M Water Pump – SIP Part No. 07614
Conforms to the requirements of the following directive(s), as indicated.
- EN 60335-1:2012+A11+A13+A1+A14+A2
- EN 60335-2-41:2003+A1+A2
- EN 62233:2008
- EN 55014-1:2017
- EN 55014-2:2015
- EN IEC 61000-3-2:2019
- EN 61000-3-3:2013+A1
- EN ISO 12100:2010
Signed:
Mr P. Ippaso – Director – SIP (Industrial Products) Ltd
Date: 19/08/2021.
PARTS LIST
Ref. No. | Description | Sip Part No. | Ref. No. | Description | Sip Part No. |
---|---|---|---|---|---|
1. | Stator | PW11-00501 | 20. | Cold compacting | PW11-00520 |
2. | Cable holder | PW11-00502 | 21. | Washer | PW11-00521 |
3. | End plate | PW11-00503 | 22. | Mains lead | PW11-00522 |
4. | Bolt | PW11-00504 | 23. | Filling plug | PW11-00523 |
5. | Fan | PW11-00505 | 24. | O-ring | PW11-00524 |
6. | Fan cover | PW11-00506 | 25. | Pump casing | PW11-00525 |
7. | Bolt | PW11-00507 | 26. | Cable holder | PW11-00526 |
8. | Dustproof cover | PW11-00508 | 27. | Drain plug | PW11-00527 |
9. | Screw | PW11-00509 | 28. | Washer | PW11-00528 |
10. | Cable holder | PW11-00510 | 29. | Mechanical seal | PW11-00529 |
11. | Terminal board | PW11-00511 | 30. | Bolt | PW11-00530 |
12. | Capacitor | PW11-00512 | 31. | Bolt | PW11-00531 |
13. | Insert spring | PW11-00513 | 32. | O-ring | PW11-00532 |
14. | Screw | PW11-00514 | 33. | Support | PW11-00533 |
15. | Mains lead clip | PW11-00515 | 34. | Bearing | PW11-00534 |
16. | O-ring | PW11-00516 | 35. | Shaft key | PW11-00535 |
17. | Washer | PW11-00517 | 36. | Rotor | PW11-00536 |
18. | Screw | PW11-00518 | 37. | Wave spring | PW11-00537 |
19. | Spring washer | PW11-00519 | N/A. | Male tail piece 1” | 27821 |
SAFETY SYMBOLS USED THROUGHOUT THIS MANUAL
Note: Supplementary information.
Danger / Caution: Indicates risk of personal injury and/or the possibility of damage.
Warning: Risk of electrical injury or damage!
SAFETY INSTRUCTIONS
IMPORTANT: Please read the following instructions carefully, failure to do so could lead to serious personal injury and / or damage to the water pump.
When using your water pump, basic safety precautions should always be followed
to reduce the risk of fire, electric shock, personal injury and / or damage to
the water pump.
Read all of these instructions before operating the water pump and save this
user manual for future reference.
SIP recommends that the water pump should not be modified or used for any
application other than that for which it was designed.
The water pump can be used to drain rain water, domestic waste water and to
remove water from flooded rooms in emergency conditions.
The pump can be used to transfer clean or moderately dirty water (no solids).
This pumps is designed to be used in the following applications:
Draining of cisterns, rainwater reservoirs, wells, ponds, storm drains,
flooded cellars, boats and yachts etc.
It is only for use with water and not chemicals or other substances that could
damage the internal seals etc.
The pump cannot be used for flammable, corrosive, explosive or dangerous
liquids.
It should not be used where aquatic life is present such as in domestic, or
commercial ponds, or similar.
If you are unsure of its relative applications do not hesitate to contact us
and we will be more than happy to advise you.
The water pump is designed to be powered from a 220 – 240V ~ 50Hz supply,
which is reliably connected to the buildings ground (earth) point.
If an extension lead is required to reach the mains supply, ensure the cross-
sectional
EXPLODED DRAWING
INSTALLATION / OPERATING INSTRUCTIONS….cont
MAINTENANCE
The pump is mainly maintenance free, you may need, from time to time to clear the impellor of any unwanted waste / debris (particularly if the pump has been in storage and un-used for a period of time). Always ensure that the mains lead is removed from the power supply before all maintenance operations.
- Remove the pump house retaining screws (see below).
- Remove the main pump housing.
- Rinse with clean water to remove debris, clean the impellor and the pump housing with scouring pad (or similar).
- Follow these instructions, in reverse to re-fit the pump housing.
SAFETY INSTRUCTIONS….cont
area of the wire in the lead is of a sufficient size for the supply of current
over the distance required.
Do not dismantle the water pump – If repairs are required, they should be
performed by a suitably qualified person; Incorrect reassembly may result in a
fire hazard and / or electric shock.
Always disconnect the water pump from the mains supply prior to cleaning or carrying out any maintenance
- KNOW YOUR WATER PUMP : Read and understand the owner’s manual and labels affixed to the water pump. Learn its applications and limitations, as well as the potential hazards specific to it.
- KEEP YOUNG CHILDREN AND UNTRAINED PERSONNEL AWAY FROM THE WORK AREA: All visitors should be kept at a safe distance from the work area.
- STAY ALERT: Always watch what you are doing and use common sense.
- DISCONNECT THE WATER PUMP FROM THE MAINS SUPPLY: When not in use.
- DO NOT ABUSE THE MAINS LEAD: Never pull the mains lead it to remove the plug from the mains socket. Keep the mains lead away from heat, oil and sharp edges. If the mains lead is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid unwanted hazards.
- HAVE YOUR WATER PUMP REPAIRED BY A QUALIFIED PERSON: The water pump is in accordance with the relevant safety requirements. Repairs should only be carried out by qualified persons using original spare parts, otherwise this may result in considerable danger to the user and void the warranty.
- DANGER! Check that the water pump is in sound condition and good working order; Take immediate action to repair or replace damaged parts.
- USE RECOMMENDED PARTS ONLY – Unapproved parts may be dangerous and will invalidate the warranty.
- WARNING! Only operate on a level and stable surface.
- DO NOT move or handle the water pump during operation.
- DO NOT leave the water pump unattended for long periods when in use. Switch the pump off and unplug from the mains supply before leaving the work area.
- Ensure that the pump is correctly turned off and drained fully when not in use; Store in a safe, dry and frost free location out of reach of children.
- ALWAYS locate the water pump in an area of good air flow to ensure that the motor does not overheat during operation.
- DO NOT dismantle or tamper with the water pump as this may be dangerous and will invalidate the warranty.
- Use only the electrical power (voltage, current and frequency) specified on the model plate of the water pump, or in this manual. If in doubt contact the manufacturer.
- DO NOT insert hands or other objects into the inlet or the outlet of the pump whilst it is connected to the mains supply
SAFETY INSTRUCTIONS….cont
- Ensure the pump is installed so that it cannot move or slip during operation.
- Always check the pump regularly, and take it out of service if the water is likely to freeze.
- Never allow the pump to run without water flowing through it.
- The pump should not be used where aquatic life is present such as in domestic, or commercial ponds, or similar.
- Never use the water pump to pump anything other than water, it should not be used to pump flammable, corrosive or other potentially damaging or dangerous liquids.
- Never immerse the pump in water.
- Allow enough room around the pump whilst it is running to ensure that there is enough air flow to cool the motor.
- Ensure that your hands are dry when dealing with mains electricity.
- Always rinse the pump with clean water and fully drain after each use.
- Use only a three-prong, UK grounded mains supply socket.
- Understand the operating environment; Before each use the operator should assess, understand and where possible reduce the specific risks and dangers associated with the operating environment. Bystanders should also be made aware of any risks associated with the operating environment.
- Children under the age of 8 should not operate, or play with the water pump.
- Cleaning and user maintenance should not be carried out by children, unless directly supervised.
- The water pump can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way, and understand the hazards involved.
- Never use flammable or corrosive liquids to clean the water pump.
- If a problem with the water pump is experienced, or if the mains lead or plug become damaged, contact your distributor for repair.
- If the water pump is used in a place of work all rules and laws etc. relating to the use of portable electrical appliances should be followed.
- Every SIP water pump is carefully tested and packed during its assembly, on receiving the pump, check that the pump has not been damaged during transportation; If the pump is damaged, immediately inform your distributor, and, do not put the pump into operation until the damage has been repaired or the item replaced.
- WARNING: Risk of Electric Shock!
CAUTION: The warnings and cautions mentioned in this user manual can not cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be applied
STALLATION / OPERATING INSTRUCTION
Warning: The water pump should be connected to the mains supply via an RCD (residual current device) with an operating current ≤30MA to ensure that the power is cut should any problems occur.
When installing, please ensure your SIP water pump is disconnected from electrical supply to prevent possible injury to people and / or damage due to un-wanted start up
Note: The hose can be fitted directly to the pump if the hose has the correct male 1” BSP thread, alternatively; follow the instructions below to fit the hose by means of a hose adaptor
- Fit the 1” inlet and outlet adaptors to the pump (see below).
- Fit the inlet and outlet hoses over the adaptors and secure with a relevant pipe clip where necessary.
- Sit the end of the suction hose into the area to be cleared and the outlet hose to where the water is to be pumped to.
Note: Solid wall / super tough hose should be used instead of lay flat to ensure the pump will work closer to its capacity.
Prior to use the pump will need to be primed:
- Remove the priming port bung (see page 10 & 12).
- Pour water through the port until it is full.
- The amount of water needed will depend on different factors such as length of hose etc
Note: The pump may need to be primed after every time the pump is stopped (depending on different factors). The use of an NRV (non return valve) on the suction hose will reduce this issue.
GETTING TO KNOW YOUR WATER PUMP
Ref | Description |
---|---|
A | Pump Mounting Holes |
B | Pump Inlet |
C | Priming Port |
D | Pump Outlet |
E | Pump Specifications |
F | Electrical Terminal Box |
G | Fan Cover |
H | Mains Lead |
GUARANTEE
This SIP water pump is covered by a 12 month parts and labour warranty covering failure due to manufacturers defects. This does not cover failure due to misuse or operating the water pump outside the scope of this manual – any claims deemed to be outside the scope of the warranty may be subject to charges Including, but not limited to parts, labour and carriage costs.
This guarantee does not cover consumables such as hose adaptors & fuses etc.
In the unlikely event of warranty claims, contact your distributor as soon as possible.
Note: Proof of purchase will be required before any warranty can be honoured.
ELECTRICAL CONNECTION
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before each use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors for wear or damage.
You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices; A residual current circuit Breaker (RCCB) should be incorporated in the main distribution board. A residual current device (RCD) with an operating current ≤30mA should be used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician.
Connecting to the power supply:
The EP2M surface mounted water pump is supplied with standard 13A UK type plug fitted. Consult the technical specification table (page 9) for the required rating, if in doubt contact a qualified electrician. Before using the water pump, inspect the mains lead and plug to ensure that none are damaged. If any damage is visible have the water pump inspected / repaired by a suitably qualified person.
The wires for the plug are coloured in the following way:
- Yellow / green: Earth
- Blue: Neutral
- Brown: Live
As the colours of the wires may not correspond with the markings in your plug, proceed as follows:
The wire which is coloured brown, must be connected to the terminal, which is
marked L or coloured red (or brown).
The wire which is coloured blue, must be connected to the terminal marked with
N or coloured black (or blue).
The wire which is coloured yellow / green should be connected to the terminal
which is coloured the same or marked with this symbol
Always secure the wires in the plug terminal carefully and tightly. Secure the cable in the cord grip carefully and securely.
ELECTRICAL CONNECTION…cont
Warning: Never connect live or neutral wires to the earth terminal of the plug. Only fit an approved plug with the correct rated fuse. If in doubt consult a qualified electrician.
Note: Always make sure the mains supply is of the correct voltage and the correct fuse, type and rating, is used.
Note: If an extension lead is
necessary in order to reach the mains supply; The
cross section should be checked so that it is of sufficient size so as to
reduce the chances of voltage drops; Always fully unwind the lead during use.
Note: The EP2M surface mounted water pump is supplied with standard 13A UK type plug and mains lead fitted. It is intended for sale and use in this configuration for the UK market only.
Warning: The water pump should be connected to the mains supply via an RCD (residual current device ) with an operating current ≤30mA to ensure that the power is cut should any problems occur.
TECHNICAL SPECIFICATIONS
- Model No.: 07614
- Model Name: EP2M Surface Mounted Water Pump
- Input Voltage: 220 – 240V ~
- Input Frequency: 50 Hz
- Input Power: 550 Watts
- Max. Pumping Head: 40 Metres
- Max. Flow Rate: 40 L/Min
- Max. Water Temperature: 35ºC
- Outlet: 1” bsp
- Mains Lead Length: 0.5 Metres
- Protection: IPX4
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate recycling bin.
Never dispose of electrical equipment or batteries in with your domestic waste. If your supplier offers a disposal facility please use it or alternatively use a recognised re-cycling agent. This will allow the recycling of raw materials and help protect the environment
FOR HELP OR ADVICE ON THIS PRODUCT PLEASE CONTACT YOUR DISTRIBUTOR, OR SIP DIRECTLY ON:
TEL:01509500400
EMAIL: sales@sip-group.com or technical
@sip-group.com
www.sip-group.com