OQIMAX 65756 LED Temperature and Humidity Projection Clook Instructions
- June 16, 2024
- OQIMAX
Table of Contents
OQIMAX 65756 LED Temperature and Humidity Projection Clook
LED temperature and humidity projection clock instruction
Functions
-
LED display time, temperature and humidity.
-
Time function: it displays hour ,minute and it can change in 12/24 hour system.
-
Date function: it displays day, month and year (from 2000 to 2099).
-
Alarm function: you can set daily alarm and snooze.
-
Temperature and humidity function: It can display and change the F/C. The normal measurement range is -10°C-50 ° (14F-122 F) .Humidity range: 20%-99%.
-
Brightness control: you can press SNOOZE key to adjust the screen brightness from high-middle-low-off.
Low light: when 18:00-5:59,the screen is in low light automatically and you can set automatic low light interval. -
The LCD projection function. You can press PROJECT key to turn on/off the projection.
-
The normal working voltage: 5V. With memory function in case of power down.
LED screen display
Key Format
6 keys (5 LED keys+1 project key)
Detailed Operations
Time mode:
-
After connecting the power, the LED screen will full display for 2s then it makes a sound “Bi” to enter the normal time mode and the default is 0:00 in 24 hour system.
-
In the normal time mode, press MODE key to enter the corresponding functions as follows:
Time mode–Date mode–Temperature mode–Night on/off (the default is off) -
In the normal time mode,long press MODE key for 2s to enter time mode, and press UP/DOWN key to set time as follows. Press and hold to quickly increase/decrease.
12/24 hour system– Hour– Minute– Escape -
If you change to the 12 hour system, the sign PM will light.
-
Setting range: HOUR is 1~12 or 0~23, MIN is 00~59.
-
Set hour, the second won’ t change; Set minute, the second will reset.
-
In the setting mode, it will escape the setting mode without any key for 10s later and keep the time you set before.
Date mode:
In the normal time mode, press MODE key to enter the date mode, the date
displays 1st, January, 2022.
-
In the date mode, long press MODE key for 2s to set date, and press UP/DOWN key to set time as follows. Press and hold to quickly increase/decrease.
Year—- Month– Date— Escape -
Setting range: MONTH is 1~12, DAY is 1~31, YEAR is 2000-2099.
-
In the setting mode, it will escape the setting mode without any key, then return to the time mode.
Alarm mode:
-
In any mode, press ALM key to display the alarm mode, alarm time displays 6:00 in 24 hour system.
-
In the alarm mode, press ALM key to turn on/off alarm.
-
In any mode, long press ALM key for 3s to set alarm, and press UP/DOWN key to set time as follows.
Press and hold to quickly increase/decrease.
Hour– Minute– Snooze time–Choose alarm (1-7/1-6/1-5)—-Escape -
The set range is: hour is 1~12 or 0~23, minute is 00~59; the snooze interval is 1-60 minutes and the default is 5 minutes; the default alarm is 1-7 daily alarm.
-
In the setting mode, it will escape the setting mode by press ALM key /without any key for 10s, and then it will return to the time mode.
-
When the alarm reaches the point, it will automatically return to the alarm mode, with a “didididi” alarm sound, from slow to faster, and the alarm sign flashes at the same time, you can press any key to stop the alarm. Or there is no key operation and the alarm stops for 1 minute, but the alarm sign will not disappear.
-
When the alarm rings, press the SNOOZE key to stop ringings and turn on one snooze, the alarm sign will flash; press other keys (except SNOOZE key) can stop ringing but no snooze.
-
During the snooze interval, press other keys to turn off the snooze; pressing the SNOOZE key does not affect the snooze.
-
When the alarm stops ringing, the alarm state is displayed, and it returns to the time state after 10s.
-
In the alarm setting mode,it will stop ringing.
(4) Temperature mode -
After connecting the power, the clock will automatically detect the temperature, press MODE key to enter the the temperature mode. The normal measurement range is -10°C~50°C(14 F~122 F).
-
When the temperature below -10°C,the screen displays -10°C;When the temperature above 50°C, the screen displays 50°C; When it has no resistance, the screen displays -10°C.
-
The clock will detect the temperature every 10s, in the temperature mode press DOWN key to switch °C/’F.
-
Humidity range: 20%-99%
Night mode
- In the normal mode, press SNOOZE key to set brightness, High –middle–Low–Off.
- In the time mode, press MODE key 2 times to enter the night setting mode, press UP or DOWN to turn on (ON)/off (OFF) night mode (the default is off (OFF) night mode).
- When the night mode turns on, during 18:00-5:59 the screen is in low light automatically.
- In the night mode, if the brightness is not adjusted, after exiting it will display the brightness you set before.
- When the night mode is ON, press and hold the MODE key for about 2s to enter the night mode time setting. The setting sequence is: start hour → start minute → end hour → end minute.
Projection function
- The projection adopts LCD display, and only the time is displayed at any time without turning off the screen. Even if the main screen LED goes off, the LCD projection does not need to be turned off. Even if the main LED screen is off, pressing PROJECTION key can also turn on the projection to check the time.
- No matter what mode the LED main screen displays, the projection only displays the time.
- When setting the time mode, the LCD can display synchronously with the main screen LED, but when setting other modes, the LCD screen only stays in the time mode.
- Press LIGHT key at any time to turn on the projection(high or middle light) to check the time.
Protection function when external power failure
- In any state, if the power is suddenly cut off, the system will enable the backup battery to maintain normal timing.
- No functions can be used during the backup battery timing.