Eemax ProSeries XTP Tankless Electric Water Heaters Instruction Manual

June 13, 2024
Eemax

Eemax-logo

Eemax ProSeries XTP Tankless Electric Water Heaters

Product Information

The ProSeries XTPTM is a tankless electric water heater. It is designed for upright installation and can also be installed with zero clearance to combustible surfaces such as plywood. The unit requires proper clearances for service and installation.

Features:

  • Upright installation
  • Zero clearance to combustible surfaces (such as plywood)
  • Requires recommended clearances for service and installation

Contact Information:

Eemax Inc.

Product Usage Instructions

Upright Installation:

  1. Locate the best position to mount the unit.
  2. Check clearances around the unit according to the diagram provided.
  3. Measure from the top, bottom, left, and right sides of the bracket to ensure proper clearances.
  4. Hang the slide lock wall mounting bracket using appropriate anchors for the wall in at least 4 hole locations.

Alternate Installation:

Note: Alternate installation is applicable for ProSeries XTP models only.

  1. Ensure zero clearance to combustible surfaces such as plywood.
  2. Follow the recommended clearances for service and installation.

Contact Information:
If you have any questions or need assistance with the product, please contact Eemax Inc. using the provided contact information.

Description

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(1\)

ProSeries XTP models are approved for zero clearance to combustible surfaces such as plywood.

Above clearances are recommended for service and installation.

  1. Locate the best position to mount the unit. Check clearances around the unit according to the diagram below. Measure from the top, bottom, left & right sides of the bracket to ensure proper clearances.

Hang the slide lock wall mounting bracket utilizing the appropriate anchors for the wall in at least 4 hole locations.

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(2\)

APPLICATIONS SCHEMATICS

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(3\)Eemax-ProSeries-XTP-Tankless-
Electric-Water-Heaters-fig- \(4\)

NOTES:

  1. CHECK LOCAL CODES
  2. WATER HAMMER ARRESTOR MUST BE INSTALLED CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZE
  3. SLOW ACTING VALVES ARE RECOMMENDED
    • TO PREVENT POSSIBLE DAMAGE TO HEATERS DUE TO WATER HAMMER
    • CHECK VALVE MUST BE INSTALLED ON THE OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE FIXTURE TO PREVENT AIR ACCUMULATION
    • RELIEF VALVE NOT REQUIRED ON HEATERS- REFER TO STATE AND LOCAL CODES

SINGLE HEATER/STORAGE TANK/PRIMARY SECONDARY LOOP

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(5\)

PARALLEL PIPING

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(6\)

NOTES
MAIN CIRCULATOR TACO 008 STAINLESS STEEL OR EQUIVALENT.

SINGLE HEATER AS PRE-HEATER

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(7\)

NOTES:

  1. CHECK LOCAL CODES
  2. WATER HAMMER ARRESTOR MUST BE INSTALLED CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZE.
  3. SLOW ACTING VALVES ARE RECOMMENDED TO PREVENT DAMAGE TO HEATERS
  4. AQUA STAT SET TO DESIRED LOOP TEMPERATURE CHECK VALVE M UST BE INSTALLED IN OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE TANK OR FIXTURES

RELIEF VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES.

SERIES APPLICATION

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(8\)

NOTES:

  1. CH ECK LOCAL CODES
  2. WATER HAMMER ARRESTOR MUST BE INSTALLED CHECK ANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZING.
  3. SLOW ACTING VALVES RECOMMENDED TO PREVENT POSSIBLE DAMAGE DUE TO WATER HAMMER RELIEF VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES.

CHECK VALVE MUST BE INSTALLED ON OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE FIXTURES

SERIES APPLICATION WITH RECIRCULATION LOOP

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(9\)

NOTE

  1. CHECK LOCAL CODES
  2. WATER HAMMER ARRESTOR MUST BE INSTALLED ill CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZING
  3. SLOW ACTING VALVES RECOMMENDED TO PREVENT POSSIBLE DAMAGE DUE TO WATER HAMMER
    • CHECK VALVE MUST BE INSTALLED IN OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE FIXTURES
    • RELIEF VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES

SERIES APPLICATION AS BOOSTER WITH RECIRCULATION LOOP

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(10\)

NOTES:

  1. CHECK LOCAL CODES
  2. WATER HAMMER ARRESTOR MUST BE INSTALLED CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZING
  3. SLOW ACTING VALVES RECDMMEND TO PREVENT POSSIBLE DAMAGE DUE TO WATER HAMMER
  4. AQUASTAT SET TO DESIRED SUPPLY TEMPERATURE
    • RELIEF VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES

TOTAL PRESSURE DROP IS EQUAL TO THE TOTAL OF AU PRESSURE DROPS ACROSS ALL WATER HEATERS COMBINED CHECK VALVE MUST BE INSTALLED ON OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE THE TANKS OR OUTLETS

PARALLEL APPLICATION

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(11\)

NOTES:

  1. CHECKLOCALCODES
  2. WATER HAMMER ARRESTOR MUST BE INSTALLED CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZING
  3. SLOW ACTING VALVES RECOMMENDED TO PREVENT POSSIBU DAMAGE DUE TO WATER HAMMER
    • RELIEf VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES
    • CHECK VALVE MUST BE INSTAUEO IN OUT\ET PORT If HEATIA IS TO BE LOCATED ABOVE FlXTURES

PARALLEL APPLICATION WITH RECIRCULATION LOOP

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(12\)

NOTES:

  1. CHECK LOCAL CODES
  2. WATER HAMMER ARRESTOR MUST Bf INSTALLED CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZING
  3. SLOW ACTING VALVES RECOMMENDED TO PREVENT POSSIBLE DAMAGE DUE TO WATER HAMMER
  4. CHECK VALVE ONLY USED IF RECIRCULATION LOOP IS INSTALLED
    • RELIEF VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES
    • CHECK VALVE MUST BE INSTALLED IN OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE FIXTURES
  • USE OF REORCULATION PUMP THROUGH UNIT IS NOT RECOMMENDED
  • TlJRN ON RATE IS 6 GPM
  • MUST OBTAIN 12 GPM TO REACH 180 DEGREES

PARALLEL WITH RECIRCULATION LOOP

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(13\)

NOTES:

  1. CHECK LOCAL CODES
    • CHECK VALVE M UST BE INSTALLED IN OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE FIXTURES

PARALLEL APPLICATION WITH STORAGE TANK

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(14\)

MUST PURGE WATER HEATER FOR A MINIMUM OF 3 MINUTES OPEN AND CLOSE DRAIN VALVE WHILE PURGING TO REMOVE ANY AIR POCKETS.

PARALLEL PIPING/STORAGE TANK/PRIMARY SECONDARY LOOPS

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(15\)

MULTIPLE HEATERS IN PARALLEL WITH PRV VALVES

Eemax-ProSeries-XTP-Tankless-Electric-Water-Heaters-fig-
\(16\)

USA AND CANADA:

Eemax Inc.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Eemax User Manuals

Related Manuals