Eemax ProSeries XTP Tankless Electric Water Heaters Instruction Manual
- June 13, 2024
- Eemax
Table of Contents
- Eemax ProSeries XTP Tankless Electric Water Heaters
- Product Information
- Product Usage Instructions
- Description
- APPLICATIONS SCHEMATICS
- SINGLE HEATER/STORAGE TANK/PRIMARY SECONDARY LOOP
- PARALLEL PIPING
- SINGLE HEATER AS PRE-HEATER
- SERIES APPLICATION
- SERIES APPLICATION WITH RECIRCULATION LOOP
- SERIES APPLICATION AS BOOSTER WITH RECIRCULATION LOOP
- PARALLEL APPLICATION
- PARALLEL APPLICATION WITH RECIRCULATION LOOP
- PARALLEL WITH RECIRCULATION LOOP
- PARALLEL APPLICATION WITH STORAGE TANK
- PARALLEL PIPING/STORAGE TANK/PRIMARY SECONDARY LOOPS
- MULTIPLE HEATERS IN PARALLEL WITH PRV VALVES
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Eemax ProSeries XTP Tankless Electric Water Heaters
Product Information
The ProSeries XTPTM is a tankless electric water heater. It is designed for upright installation and can also be installed with zero clearance to combustible surfaces such as plywood. The unit requires proper clearances for service and installation.
Features:
- Upright installation
- Zero clearance to combustible surfaces (such as plywood)
- Requires recommended clearances for service and installation
Contact Information:
Eemax Inc.
- 400 Captain Neville Drive, Waterbury, CT 06705
- Toll Free: 1-800-543-6163 or 203-267-7890
- Fax: 203-267-7975
- Email: Eemax.Support@eemax.com.
Product Usage Instructions
Upright Installation:
- Locate the best position to mount the unit.
- Check clearances around the unit according to the diagram provided.
- Measure from the top, bottom, left, and right sides of the bracket to ensure proper clearances.
- Hang the slide lock wall mounting bracket using appropriate anchors for the wall in at least 4 hole locations.
Alternate Installation:
Note: Alternate installation is applicable for ProSeries XTP models only.
- Ensure zero clearance to combustible surfaces such as plywood.
- Follow the recommended clearances for service and installation.
Contact Information:
If you have any questions or need assistance with the product, please contact
Eemax Inc. using the provided contact information.
Description
ProSeries XTP models are approved for zero clearance to combustible surfaces such as plywood.
Above clearances are recommended for service and installation.
- Locate the best position to mount the unit. Check clearances around the unit according to the diagram below. Measure from the top, bottom, left & right sides of the bracket to ensure proper clearances.
Hang the slide lock wall mounting bracket utilizing the appropriate anchors for the wall in at least 4 hole locations.
APPLICATIONS SCHEMATICS
NOTES:
- CHECK LOCAL CODES
- WATER HAMMER ARRESTOR MUST BE INSTALLED CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZE
- SLOW ACTING VALVES ARE RECOMMENDED
- TO PREVENT POSSIBLE DAMAGE TO HEATERS DUE TO WATER HAMMER
- CHECK VALVE MUST BE INSTALLED ON THE OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE FIXTURE TO PREVENT AIR ACCUMULATION
- RELIEF VALVE NOT REQUIRED ON HEATERS- REFER TO STATE AND LOCAL CODES
SINGLE HEATER/STORAGE TANK/PRIMARY SECONDARY LOOP
PARALLEL PIPING
NOTES
MAIN CIRCULATOR TACO 008 STAINLESS STEEL OR EQUIVALENT.
SINGLE HEATER AS PRE-HEATER
NOTES:
- CHECK LOCAL CODES
- WATER HAMMER ARRESTOR MUST BE INSTALLED CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZE.
- SLOW ACTING VALVES ARE RECOMMENDED TO PREVENT DAMAGE TO HEATERS
- AQUA STAT SET TO DESIRED LOOP TEMPERATURE CHECK VALVE M UST BE INSTALLED IN OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE TANK OR FIXTURES
RELIEF VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES.
SERIES APPLICATION
NOTES:
- CH ECK LOCAL CODES
- WATER HAMMER ARRESTOR MUST BE INSTALLED CHECK ANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZING.
- SLOW ACTING VALVES RECOMMENDED TO PREVENT POSSIBLE DAMAGE DUE TO WATER HAMMER RELIEF VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES.
CHECK VALVE MUST BE INSTALLED ON OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE FIXTURES
SERIES APPLICATION WITH RECIRCULATION LOOP
NOTE
- CHECK LOCAL CODES
- WATER HAMMER ARRESTOR MUST BE INSTALLED ill CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZING
- SLOW ACTING VALVES RECOMMENDED TO PREVENT POSSIBLE DAMAGE DUE TO WATER HAMMER
- CHECK VALVE MUST BE INSTALLED IN OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE FIXTURES
- RELIEF VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES
SERIES APPLICATION AS BOOSTER WITH RECIRCULATION LOOP
NOTES:
- CHECK LOCAL CODES
- WATER HAMMER ARRESTOR MUST BE INSTALLED CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZING
- SLOW ACTING VALVES RECDMMEND TO PREVENT POSSIBLE DAMAGE DUE TO WATER HAMMER
- AQUASTAT SET TO DESIRED SUPPLY TEMPERATURE
- RELIEF VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES
TOTAL PRESSURE DROP IS EQUAL TO THE TOTAL OF AU PRESSURE DROPS ACROSS ALL WATER HEATERS COMBINED CHECK VALVE MUST BE INSTALLED ON OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE THE TANKS OR OUTLETS
PARALLEL APPLICATION
NOTES:
- CHECKLOCALCODES
- WATER HAMMER ARRESTOR MUST BE INSTALLED CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZING
- SLOW ACTING VALVES RECOMMENDED TO PREVENT POSSIBU DAMAGE DUE TO WATER HAMMER
- RELIEf VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES
- CHECK VALVE MUST BE INSTAUEO IN OUT\ET PORT If HEATIA IS TO BE LOCATED ABOVE FlXTURES
PARALLEL APPLICATION WITH RECIRCULATION LOOP
NOTES:
- CHECK LOCAL CODES
- WATER HAMMER ARRESTOR MUST Bf INSTALLED CHECK MANUFACTURERS INSTALLATION INSTRUCTIONS FOR PROPER LOCATION AND SIZING
- SLOW ACTING VALVES RECOMMENDED TO PREVENT POSSIBLE DAMAGE DUE TO WATER HAMMER
- CHECK VALVE ONLY USED IF RECIRCULATION LOOP IS INSTALLED
- RELIEF VALVE NOT REQUIRED ON HEATERSREFER TO STATE AND LOCAL CODES
- CHECK VALVE MUST BE INSTALLED IN OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE FIXTURES
- USE OF REORCULATION PUMP THROUGH UNIT IS NOT RECOMMENDED
- TlJRN ON RATE IS 6 GPM
- MUST OBTAIN 12 GPM TO REACH 180 DEGREES
PARALLEL WITH RECIRCULATION LOOP
NOTES:
- CHECK LOCAL CODES
- CHECK VALVE M UST BE INSTALLED IN OUTLET PORT IF HEATER IS TO BE LOCATED ABOVE FIXTURES
PARALLEL APPLICATION WITH STORAGE TANK
MUST PURGE WATER HEATER FOR A MINIMUM OF 3 MINUTES OPEN AND CLOSE DRAIN VALVE WHILE PURGING TO REMOVE ANY AIR POCKETS.
PARALLEL PIPING/STORAGE TANK/PRIMARY SECONDARY LOOPS
MULTIPLE HEATERS IN PARALLEL WITH PRV VALVES