FONDA TECHNOLOGY FONDA-LCU71LW Lora Zhaga Lamp Controller User Manual
- June 16, 2024
- FONDA TECHNOLOGY
Table of Contents
TECHNOLOGY FONDA-LCU71LW Lora Zhaga Lamp Controller
User Manual
FONDA-LCU71LW Lora Zhaga Lamp Controller
Application
Featurese
| LORA transmission, support LORAWAN
---|---
With standard ZHAGA(book 18) 4-PIN interface, plug and play
Remotely turn ON/OFF
Photocell auto control
DALI 2.0 protocol, work with D4i and Philips SR series driver
Remotely read electrical parameters
Application scenario: only applicable to road lighting
| Auto-reporting electrical parameters and total energy, remote resetting
---|---
Lamp failure detection and automatic notification for alarms
Lightning protection
IP Grade: IP66
Optional module: Tilt
Optional module: GPS
Basic Information
**** Input | Voltage Range | 12-24VDC |
---|---|---|
Current | 0.02A | |
Transient power | ≦2W | |
Static Power | <1W |
DALI Information
Mode | DALI 2.0 / D4i |
---|---|
Bus voltage | 23V DC |
Input current | 60mA |
Working Environment
Temperature | -40~+60℃ |
---|---|
Humidity | <95% |
IP Grade | IP66 |
Size | Diameter 84mm, Height 48mm |
Weight | 0.1KG |
Data Reading
Voltage Detection | Yes |
---|---|
Current Detection | Yes |
Data Accuracy | ≤3% |
Active Power Calc | Yes |
Power Factor Calc | Yes |
Energy Record | Yes |
Communication
Transmission | LORA |
---|---|
Model | FONDA-LCU71LW |
Frequency | AS923 |
Receiver Sensitivity | -135±1dBm(@SF=12) |
Transmit power | 19.5dBm |
Speed | ADR (SF9 to SF12) |
Communication mode | CLASS-C |
Protocol specification | LORAWAN1.0.2 |
Functions
Failure Report | Automatically report, query to report |
---|---|
Failure Type | Lamp failure, power failure, over voltage, over current, under |
voltage
Task Mode| Photocell auto control, threshold configurable,Support local
scheduled task
Energy Record| Record total energy consumed and reset
Wiring Information
Pin Number | Function |
---|---|
1 | +24V power supply |
2 | Negative pole for DALI or DALI based protocol and shared ground return for |
24V supply
3| Positive pole for DALI or DALI based protocol
4| General digital I/O (greater than 7V DC) for LSI sensor
Bottom view Receptacle
Assembly (Gasket, Nut and Washer not shown for clarity)
Manufacture Company Name: ZHEJIANG FONDA TECHNOLOGY CO.,LTD
Address: 9TH FLOOR SHUYU BUILDING, NO.98 WENYI WEST ROAD, XIHU DISTRICT,
HANGZHOU, ZHEJIANG, CHINA Commercial Record (Trade License):
913301065802789569
This model of our company’s FCC certified products: FONDA-LCU71LW, make the
following statement:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
FCC Warning:
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:-Reorient or relocate
the receiving antenna.-Increase the separation between the equipment and
receiver.-Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.-Consult the dealer or an experienced
radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment.
FONDA TECHNOLOGY
www.fondalighting.com
*Subject to change without notice
Documents / Resources
|
FONDA TECHNOLOGY FONDA-LCU71LW Lora Zhaga Lamp
Controller
[pdf] User Manual
FONDA-LCU71LW Lora Zhaga Lamp Controller, FONDA-LCU71LW, Lora Zhaga Lamp
Controller, Lamp Controller, Controller
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>