LifeHood GBS-2109-B Bathroom Scale for Body Weight User Manual
- June 16, 2024
- LifeHood
Table of Contents
- Symbol meaning
- Your scale and its environment
- Efficient use of your scale
- General instructions
- Device components
- List
- LED Display
- Insert the batteries
- Install App and pair-up
- Select measurement unit
- Daily measurement
- Data transmission
- Error prompt
- When measuring
- When data transmitting
- Specifications
- FCC regulations
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**LifeHood GBS-2109-B Bathroom Scale for Body Weight User Manual
**
Symbol meaning
The warning signs and symbols are essential to ensure your correct and safe use of this product and protect you and others from injury. Please kindly find the meanings of the warning signs and symbols, which you may encounter in the label and user manual, as follows:
| Symbol for “THE OPERATION GUIDE MUST BE READ”| | Symbol for “MANUFACTURER”
---|---|---|---
| The Bluetooth Combination Mark| | Symbol for ‘RECYCLE’
| Symbol for “SERIAL NUMBER”| | Symbol for ‘ENVIRONMENT PROTECTION – Waste
electrical products should not be disposed of with household waste. Please
recycle where facilities exist. Check with your local authority or retailer
for recycling advice”.1
| Symbol for “DIRECT CURRENT”
Your scale and its environment
To ensure your safety as well as the service life of your scale, please avoid using the scale under the following circumstances:
- Slippery floor such as tile floor
- Jumping onto the platform immediately after bath or with wet feet
- Near a cell phone or microwave oven.
Avoid storage in the following locations :
- Where there is water
- Where the device may be exposed to extreme temperatures, humidity, moisture, direct sunlight, dust, or salt air
- Where there is risk of shock or drop
- Where you store chemicals or full of corrosive gases
- Where in reach of the infants or children
Efficient use of your scale
To ensure the accuracy of measurement, please follow below instructions when you start measurement.
- Place the scale on a flat, hard surface. Soft surface such as carpet will affect the performance of the scale.
- Start measurement at least two hours after Getting up or Dinning.
- Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and dinning.
- Always start measurement in the same time slot and on the same scale located on the same flat, hard surface.
- Any information provided by this scale is in no way meant to treat, cure or prevent any disease or illness from happening. If in doubt, contact your physician.
- It is intended for use in the domestic setting only.
General instructions
Life Hood Weight Scale GBS-2109-B applies SENSE ON technology. It’s not necessary to turn on or turn off the scale, just stand on the scale for measurement. It is delicate and trendyonvenience for using.
Device components
List
- Weight Scale GBS-2109-B
- Three AAA-size Batteries (1.5V per each)
- User Mauna
LED Display
| Pound| | Bluetooth Connection Indication
---|---|---|---
| Kilogram| |
Insert the batteries
-
Open the battery door in the back of the scale.
-
Remove insulating strip from beneath the battery (if fitted) or insert batteries (3 x 1.5V AAA) observing the polarity signs (+ and -) inside the battery compartment.
-
The all digits will be shown on the LED.
-
Close the battery door and wait until the digits “0.00kg” are shown on the LED.
-
The scale will turn off about 15s if there is no operation after the batteries are installed.
CAUTION
- When the symbol “Lo appears, the device will soon shut down. Then you shall replace with a new set of batteries. Please replace all three batteries at the same time. Do NOT mix the old batteries with the new one.
- Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage. Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries.
- If you do not intend to use this unit for a prolonged period of time, it is advisable to remove the batteries before storing.
- Do not mix alkaline, standard(carbon-zinc), or rechargeable(Ni-Cd, Ni-MH, etc.) batteries.
- Use the scale three times a day, and the lifetime of battery is about one year.
Install App and pair-up
With the advanced Bluetooth 5.0 technology applied, the mobile or portable
equipment’s, which are equipped with Bluetooth function in line with BLE
Technical Specifications as well as BLP Protocol established by global
organization Bluetooth SIG, are capable to receive your personal health data.
Just simply install the Hopi Health APP and pair up your scale with your
mobile or portable equipment’s. Then you may enjoy the comprehensive health
solution provided by life hood
Note : It is only available for the device which supports Bluetooth 5.0
technology
Hopi Health App
-
Download and open the「Hapi Health」App. Connect with the scale. the scale will be shown
on Homepage of the App. Weighing data transfer to the app via Bluetooth. symbol will be
shown on the LED. -
Download and open the App. Create an account (optional) or click “Try now” to use as a
guest. Turn on the scale and make sure the screen is on. -
Press “Add Device” on the App, and the scale will pop out, press “Go to add”. Wait till the
connection is accomplished, then press “Next”. Press “Done” and the scale will be shown on
Homepage of the App.
If SUCCEED, symbol “ ” will be shown on the LED
If FAIL, symbol “ ” will not be shown on the LED.
Select measurement unit
With batteries correctly installed, press “UNIT” button in the back of the
scale to selecasurement unit. The default measurement unit is “kg”. You may
press “UNIT” button to choose between kilogram and pound.
Daily measurement
-
With original SENSE ON patent technology, the scale will automatically switch on as you step on the platform barefooted.
-
Stand still and keep full contact with the scale, the weight data on the LED will blink
twice, then the weight is locked. -
When your scale is successfully connected to your smartphone and the Bluetooth is ON,
it will process data transmission automatically.
(Please refer to Data Transmission for more details.)
Data transmission
-
With GBS-2109-B successfully pair-up with your smartphone, the measurement data will be transmitted to your mobile via Bluetooth. 68.05.
-
ONLY when the measuring results are attached to a specific User ID will it be transmitted to your mobile after measurement.
CAUTION
-
Interference may occur in the vicinity of equipment marked with the following symbol . And
the Analyzer may interfere vicinity electrical equipment. -
To enable the data transmission function, this product should be paired to a Bluetooth 4.0 end.
How to mitigate possible interference?
-
The range between the Analyzer and the Bluetooth end should be reasonably close, from 1
meter to 10 meters. Please ensure no obstacles between the Analyzer and the Bluetooth end
so as to obtain quality connection. -
To avoid interference, other electronic devices (particularly those with Bluetooth transmission / Transmitter) should be kept at least 1 meter away from the Analyzer.
Error prompt
Error | Description | Solution |
---|---|---|
Overload. | Stop using this scale for measurement. | |
Low Battery. | Replace all three batteries in the same time. Please purchase |
the authorized batteries for replacement.
When measuring
Problem | Root Cause | Solution |
---|---|---|
No display onLED when thedevice powers on. | Batteries not yet | |
installed.Batteries ) | Install the batteries.(Please refer to Insert the | |
Worn batteries. | Replace all three batteries at the same time. Please purchase |
the authorized batteries for replacement.
The device powers off automatically.| Low battery.| Replace all three
batteries at the same time. Please purchase the authorized batteries for
replacement.
When data transmitting
Problem | Root Cause | Solution |
---|---|---|
Data transmission failed. | Bluetooth is OFF. | Turn ON the Bluetooth via |
Setting
App is OFF.| Press the icon to turn ON your app.
Out of range of Bluetooth transmission| Place your smartphone closer to the
scale.
Specifications
Product Name | Glass Body Scale |
---|---|
Dimension | Scale: Approx. 280x280x23.5mm |
Net Weight | Approximately 1.22kg ( Excluding the dry cells) |
Display | Digital LED |
Measurement Unit | Kilogram / Pound |
Measurement Range | 5kg to180kg t 11lb to 396.81b |
Division | 5-100kg: 0.05kg/0.2Ib; 100.1-180kg: 0.1kg/0.2Ib; |
Accuracy | Temperature requirement: 25±5 C50kg: ±0.2kg; 100kg: ±0.3kg; 150kg: |
±0.4kg; 180kg: ±0.5kg
Working Environment| Temperature: 5 C to 40 C Relative Humidity: s90%
RHAtmospheric pressure: 86kPa to 106kPa
Storage Environment| Temperature: -20 C to 60 C Relative Humidity: s90%
RHAtmospheric pressure: 50kPa to 106kPa
Power Source| 4.5V (Three AAA-size Batteries)
Auto-ON| SENSE ON technology
Auto-OFF| About 15 seconds while showing 0.00;About 15 seconds after the
weight data is locked
Accessories|
- Three AAA-size Batteries
- User Manual
Mode of Operation| Continuous Operation
Frequency Range| 2402MHz-2480MHz
RF Max Power| Dom
About the Accuracy of This Product
- This product passes strict inspection before delivery and therefore its accuracy is guaranteed by the manufacturer. Please refer to the above table for the descriptions on accuracy.
- This product is specially designed for body scale as well as weight measurement. It should NOT be used by anyone during the process of transaction for verification of goods weight.
FCC regulations
FCC User Guide Information
Radio Frequency Interface Requirements – FCC
Note : This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-
Reorient or relocate the receiving antenna;
-
Increase the separation between the equipment and receiver;
-
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected; -
Consult the dealer or an experienced radio / TV technician for help.
Radio Transmitters (Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC RF Exposure Guidelines
Safety Information
Reducing RF Exposure – Use Properly
Only operate the device in accordance with the instructions supplied. This
device complies with FCC radiation exposure limits set forth for noncontrolled
environment.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>