Digital Control Panel For
Electric Height Adjustable Desk
User Guide
SD40 Digital Control Panel For Electric Height Adjustable Desk
Lifting Function:
Press” “button, the desk will rise and stop automatically when it rises to the
highest point.
Press” “button, the desk will descend and stop automatically when it descends
to the lowest point.
Release the button and the desktop stops the current action.
Preset Memory Height Function:
Long press the digit “[ 1 l button for 3 seconds, and “S-1″ is displayed,
indicating that the current height is saved to the [Il” button successfully.
The same operation to digit (1)” button.
Recall Memory Height Function:
Short press the digit ” 1 ” button to recall ts corresponding height and
automatically run the desktop to this height. The same operation to digit “( 2
)” button.
Desktop Reset:
When “ERl” is displayed or the desktop is at the lower limit position,
press and hold the “ “button for more than 3 seconds until “RST” s displayed
and release the button. At this time, the system has entered the reset
preparation state. Press and hold the “ “button again, the desktop begins to
descend to the bottom of the machine and rebound to a certain height. After
reset, the owest height is displayed, and then release the “ ” button.
Child Safety Lock:
Press and hold the buttons for more than 5 seconds to set the child safety
lock. After the setting s successful, “LOC’ will be displayed. At this time,
all key operations are invalid, but the child lock can still be cancelled by
pressing and holding the” button for more than 5 seconds.
Anti-Collision Detection:
An advanced feature that helps you stop your desk from moving and reverse
ts movement slightly when the desk touches something.
Overheat Protection:
“hot” is displayed. If the desktop continuously rises and descends too
frequently, desk motor will overheat. n order to avoid damage to the desk
motor, desk’s height adjustment will be disable for around 18 minutes.
Motor Abnormal Protection:
When “ER1” is displayed, please power off first, check and ensure that the
connection between the motor and the controller is reliable, then power on
again and start reset procedure.