Specifications

  • Product Name: Plastic Lever Pump
  • Recommended Use: Water-based media, Detergents, Soaps, Antifreeze, Windshield washer, Hydraulic oils, Lubricants, Herbicides & Pesticides, Adblue, Urea, DEF etc.
  • Do Not Use With : Any media not compatible with materials used in the pump construction
  • Wetted Components : Polyacetal, Polypropylene, Polyethylene, PVC & Viton
  • Flow Rate : Up to 1 pint (500ml) per stroke
  • Operating Temperature: Suitable for use with oil, antifreeze, water, windshield fluid, pesticides & herbicides, DEF/ADBLUE, urea

Product Usage Instructions

Assembly of Suction Pipes

To assemble the suction pipes, follow these steps:

  1. Thread Suction Pipe B into Suction Pipe A.
  2. Thread Suction Pipe A+B into Suction Thread Hole.
  3. Adjust the length of Suction Pipe C to fit it with the height of the Drum Can and fix pipes B+C with Joint Nut.

Installation

To install the pump, follow these steps:

  1. Pump comes with a two-piece Suction tube. Use the telescopic suction tube (B+C) for smaller drums (15-50 litre) and assemble the other suction tube (A) with the telescopic suction tube (B+C) for 205 litre drums.
  2. Screw the Suction tube to the 3/4 female threaded opening at the pump inlet.
  3. Insert the complete pump assembly (Pump & Suction Tube together) into the drum from the 2 threaded openings on the drum.
  4. Tighten the 2 Bung Threads on the pump onto the threaded opening on the drum.
  5. Use the Built-in Lock Nut to position the pump outlet on the drum.
  6. Connect the Corrugated discharge hose using the Hose Clip onto the Pump Outlet.

Operating Instructions

To operate the pump, follow these steps:

  1. 1. Loosen the Anti Siphon Vent Cap on the Pump outlet if you wish to manually operate the pump. If Siphon action is desired, tighten the cap fully.
  2. Start operating the pump handle, making sure that the corrugated discharge tube has its end in the receiving container.

NOTE: Be careful not to spill the liquid on the ground when pumping it into the receiving container.

FAQ

Q: Can this pump be used with fuel?

A: No, this pump should never be used for fuel transfer.

Q: Can this pump be used with solvents or thinners?

A: No, this pump must not be used with thinners, solvents, or any media not compatible with materials used in the pump construction.

Q: What is the recommended use for this pump?

A: The recommended use for this pump includes water-based media, detergents, soaps, antifreeze, windshield washer, hydraulic oils, lubricants, herbicides & pesticides, DEF/ADBLUE, urea.

Q: What are the wetted components of this pump?

A: The wetted components of this pump are Polyacetal, Polypropylene, Polyethylene, PVC & Viton.

Q: What is the flow rate of this pump?

A: The flow rate of this pump is up to 1 pint (500ml) per stroke.

Q: What is the operating temperature range for this pump?

A: This pump is suitable for use with oil, antifreeze, water, windshield fluid, pesticides & herbicides, DEF/ADBLUE, urea.

Plastic Lever Pump

Lever action barrel pump, designed for use with high viscosity oils, agricultural chemicals etc. Pump design makes it extremely convenient & comfortable to pump thick oils without excessive fatigue Choice of materials used in the pump construction, make it versatile for use with water based media, as well as select chemicals Built-in 2″ bung adaptor allows the pump to be fixed on drums with 2″ opening Pump position can be adjusted using the lock nut incorporated in the pump body Pump outlet is fitted with an air vent cap which when loosened breaks the siphon action Supplied complete with suction tube for use with 50-205 litres (15-55 gallons) drums & 2m × 3/4″ flexible corrugated discharge hose Also available with Tri-sure adaptor – making the pump suitable for use on plastic drums with buttress threads

WETTED COMPONENTS

Polyacetal, Polypropylene, Polyethylene, PVC & Viton

RECOMMENDED USE

Water-based media, Detergents, Soaps, Antifreeze, Windshield washer, Hydraulic oils, Lubricants, Herbicides & Pesticides, Adblue, Urea, DEF etc. Pump should only be used with Non-flammable liquids

DO NOT USE WITH

Any media not compatible with materials used in the pump construction These pumps must never be used for fuel transfer or with thinners, solvents etc.

GROZ-44185-Plastic-Lever-Pump-FIG-1

FEATURES

GROZ-44185-Plastic-Lever-Pump-FIG-2

FLUIDS

HOW TO ASSEMBLE SUCTION PIPES (REFER TO FIG. 1)

  1. Thread Suction Pipe B into Suction Pipe A. (1)
  2. Thread Suction Pipe A+B into Suction Thread Hole. (2)
  3. Adjust the length of Suction Pipe C to fit it with the height of the Drum Can and fix pipes B+C with Joint Nut. (3)
  4. Length of Assembled Suction Pipes
    • Suction Pipes(A+B+C) :
    • 690 – 980 mm
    • Suction Pipes(B+C) :
    • 350 – 640 mm

INSTALLATION (REFER TO FIG. 2)

  1. Pump comes with a two piece Suction tube. One tube is Telescopic (B+C) in nature & should be used when using the pump on smaller 15-50 litre (5-16 gal.) drums. When using the pump with 205 litre (55 gal.) drums assemble the other suction tube (A) with the telescopic suction tube (B+C) & extend it fully.
    NOTE: Tighten the connections gently so as not to shear the threads.

  2. Now screw the Suction tube to the 3/4″ female threaded opening at the pump inlet. (1)

  3. Insert the complete pump assembly (Pump & Suction Tube together) into the drum from the 2″ threaded opening on the drum. (2)

  4. Tighten the 2″ Bung Threads on the pump onto the threaded opening on the drum. (3)

  5. Pump has a Built-in Lock Nut which can be turned & used to position the pump outlet on the drum. (4)

  6. Connect the Corrugated discharge hose using the Hose Clip onto the Pump Outlet. (5)

OPERATING INSTRUCTIONS (REFER TO FIG. 3)

  1.  Loosen the Anti Siphon Vent Cap on the Pump outlet if you wish to manually operate the pump. If Siphon action is desired, tighten the cap fully. (1)

  2. Start operating the pump handle, making sure that the corrugated discharge tube has it’s end in the receiving container. (2)
    NOTE: Be careful not to spill the liquid on the ground when pumping the liquid into the receiving container.

  3. Within a few strokes, pump will start dispensing media.
    NOTE: Operate the handle smoothly to prevent the pump head from getting damaged.

  4. If the Anti-siphon vent cap is in the fully closed position, pump will keep dispensing even without operating the pump handle until the media level in the supply container becomes equal to the media level in the receiving container. Siphon action can at any time be stopped by opening the anti siphon vent cap.

PRIMING
Close the anti-siphon vent cap and move the handle up and down rapidly until the fluid starts pouring out of the dischargetube.
NOTE: For best results, pump should be used for pumping only one type of media.

PARTS LIST

REF NO. PARTS DESCRIPTION QTY.
1 Barrel 1
2-1 Top Cover ‘A’ 1
2-2 Top Cover ‘B’ 1
3 Handle 1
4 Cap 1
5 Spout 1
6 Piston 1
7 Piston Clacker 1
8 Lock Nut 1
9 Spout Connector 1
10 Crank 1
11 Air Vent Cap 1
12 Guide Bush 1
13 Pivot Pin 1
14 Crank Plate 1
15 Shaft 1
16 Inlet Valve 1
17 PT Screw 10
18 Barrel Seal 1
19 Shaft Seal 1
20 Pipe ‘A’ 2
21 Connector 1
22 Pipe Ring 1
23 Pipe ‘B’ 1
24 Ring 1
25 Pipe Seal 1
26 Joint Nut 1
27 PP Disc 1
28 Nut (M12) 1
29 Hose Clip 1
30 Discharge Hose 1
31 Pipe C 1

EXPLODED VIEWGROZ-44185-Plastic-Lever-Pump-FIG-7

TROUBLESHOOTING

PROBLEM CAUSE SOLUTION
Pump not dispensing media The pump needs to be primed Refer to “Priming”

section
Less discharge| Pump is drawing in air| 1.   Check whether the anti siphon vent cap is tighten on the spout

2.    Tighten the suction tubes onto the barrel inside threads