GROZ 45521 12V Electric Fuel and Oil Pump Instruction Manual
- June 14, 2024
- GROZ
Table of Contents
INSTRUCTION MANUAL
S2620, REV B
Electric Oil & Fuel Pump
Vertical mount fuel and oil pump for light use in Industrial, Automotive,
Heating and Marine applications.
Equipped with a centrifugal electric motor with double insulation making it
safe for use with water and emulsions
Manufactured from chemically inert materials
Built in 2″ Bung adaptor to fit on most of the drum sizes
RECOMMENDED USE
Diesel, Kerosene, Water, Emulsions, Mineral & Synthetic Oils, Heating Oils,
Antifreeze etc.
WETTED COMPONENTS
POM, Polypropylene, Stainless Steel, Nitrile Rubber, Viton & PTFE
FLUIDS
DIESEL | KEROSENE | WATER | ANTIFREEZE | OIL |
---|---|---|---|---|
SPECIFICATIONS
DESCRIPTION| EOP/DC/12| EOP/DC/24| EOP/AC/110|
EOP/AC/230
---|---|---|---|---
SUPPLY VOLTAGE| 12V DC| 24V DC| 110V AC| 230V AC
MAX. FLOW RATE| Upto 9.25 GPM
(35 LPM)| Upto 9.25 GPM
(35 LPM)| Upto 10.5 GPM
(40 LPM)| Upto 10.5 GPM
(40 LPM)
ELECTRIC MOTOR| 0.43 HP Centrifugal Motor| 0.43 HP Centrifugal Motor| 0.43 HP
Centrifugal Motor| 0.43 HP Centrifugal Motor
AMP DRAW FROM THE BATTERY| 9.2 Amp| 5.6 Amp| 2.9 Amp| 1 Amp
ABORBED POWER| 110 W| 135 W| 320 W| 224 W
INSULATION CATEGORY| III| III| II| II
DISCHARGE HEAD| 1 meter| 1 meter| 1 meter| 1 meter
DELIVERY HOSE| 3/4” ID x 2.5 m long| 3/4” ID x 2.5 m long| 3/4” ID x 2.5 m
long| 3/4” ID x 2.5 m long
TANK ADAPTOR| 2” & M64x4| 2” & M64x4| 2” & M64x4| 2″ & M64x4
INLET| Telescopic suction tube extends from 31-1/2″ (800 mm) to 43-45/64″
(1110 mm)
OUTLET| 3/4” Hose Barb| 3/4” Hose Barb| 3/4” Hose Barb| 3/4” Hose Barb
DISPENSING NOZZLE| Manual Polypropylene Nozzle with 3/4” Hose Barb| Manual
Polypropylene Nozzle with 3/4” Hose Barb| Manual Polypropylene Nozzle with
3/4” Hose Barb| Manual Polypropylene Nozzle with 3/4” Hose Barb
BATTERY / POWER CABLE| 3 m long with Battery Clamps| 3 m long with Battery
Clamps| 2 m long with Plug| 2 m long with Plug
WATER / DUST PROTECTION| IPX 4
(protection against splashing water)| IPX4
(protection against splashing water)| IPX4
(protection against splashing water)| IPX4
(protection against splashing water)
NOISE LEVEL| 70 db| 70 db| 70 db| 70 db
WORKING TEMPERATURE RANGE| −10°C to +40°C (14°F to 104°F)| −10°C to +40°C
(14°F to 104°F)| −10°C to +40°C (14°F to 104°F)| −10°C to +40°C (14°F to
104°F)
TOOLS NEEDED
Phillips Screwdriver PH1
INSTALLATION
- Fasten the telescopic suction tube to the moto
- Screw the pump body (1) onto the drum or tank, taking care to place the pump in a vertical position
- Assemble the delivery hose onto the delivery port of the pump bodyand fasten it with a hose clamp
- Assemble the dispensing nozzle (3) onto the opposite end of the delivery hose and fasten in place with a hose clam
- Now connect the pump to the power source
WARNING
The motor and switch are not of an anti-explosive type. Do not use the pump in
areas where there is risk of explosion Do not use the pump for gasoline,
inflammable liquids with PM < 55° C, Food Liquids, Corrosive Chemical Products
and Solvents
Do not smoke or use open flame during refuelling
Avoid spilling diesel, which is harmful to the environment
Never operate the pump when empty
Do not leave the motor running under delivery in closed condition when the
Trigger (6) is not pressed) for more than five minutes
The pump only works in vertical position
The pump must only be used under the surveillance of the operator
Before connecting the pump to the power supply, ensure that the voltage
complies with the limitations indicated
Power that is out of specified limits can damage the electrical components
Max. acceptable variation = ± 5% of the nominal value
COMMISSIONING AND USE
- Priming Procedure: Open the nozzle by pressing the trigger (6). Start the pump by repeatedly activating the lever (5) until the liquid starts flowing from the dispensing nozzle.
- When fluid starts flowing out, start the motor using the switch (7) and proceed to fuelling.
- When finished, release the Trigger and switch off the motor.
WARNING
The operator must repeat “Priming Procedure” under the following situations:
- After an extended stop
- If liquid does not flow
- If the motor is re-started
- After a power failure
EMERGENCY OPERATION
In the case of power failure or when small quantities of liquid need to be transferred, it is possible to operate the pump manually, in the following manner:
- Keep the trigger (6) of the dispensing nozzle pressed
- Activate the lever (5) repeatedly till liquid starts flowing out of the nozzle
DISASSEMBLY AND MAINTENANCE
This pump requires little maintenance, but we recommend the periodic
inspection, and if necessary cleaning of the intake filter, and the state of
efficiency of the hoses and the dispensing nozzle, in order to ensure a long
working life.
If the electric cable is damaged it must be replaced by a technically
qualified person so as to prevent any risk.
Make sure that the place where the pump is installed is not susceptible to
being overflowed.
PART DESCRIPTION
REF. NO. | DESCRIPTION | QTY. |
---|---|---|
1 | Pump Body | 1 |
2 | 2.5 meter × 3/4″ rubber hose (to be cut as required) | 1 |
3 | Dispensing Nozzle [including trigger (8)] | 1 |
4 | Hose Clamps | 2 |
5 | Lever | 1 |
6 | Trigger | 1 |
7 | ON/OFF Switch | 1 |
8 | Telescopic Suction Tube | 1 |
TROUBLESHOOTING
PROBLEM | CAUSE | SOLUTION |
---|---|---|
The motor is not turning | Lack of electric power | Check the electrical |
connections and safety systems.
Contact the Service Department
The pump is not primed| Probable emptying of the intake tube| Prime according
to the described procedure.
GROZ WARRANTY POLICY
GROZ makes all efforts to ensure that its products meet the highest standards
of quality and durability and warrants to the original purchaser its range of
products for a period of 12 months from GROZ Invoice date, against defects in
materials and workmanship. If the GROZ product is part of a set, only the
portion that is defective is subject to this warranty.
This warranty does not apply to damage due directly or indirectly, to misuse,
abuse, wear and tear, negligence or accident, repairs or alterations outside
GROZ plants, or to lack of maintenance. GROZ shall in no event be liable for
death, injuries to persons or property or for incidental, contingent, special
or consequential damages arising from the use of its products. It is upto the
user to determine suitability and safety of the product for their intended
use, and the user assumes all risks and liability herewith.
In no event, shall GROZ’s liability exceed the invoiced cost of the product
In case of identification of defect covered under this warranty, the same must
be notified in writing to GROZ /GROZ designated authorized service location.
Proof of purchase date must accompany the complaint. GROZ reserves the right
to call back the faulty unit, all charges including transportation prepaid.
On verification of the defect, the unit will be repaired or replaced with a
new or reconditioned product or part of equal utility or a full refund given
at GROZ’s discretion. The repaired /replaced units will be returned to the
user freight prepaid, using most economical freight carrier. However if
determined that the defect resulted from causes not within the scope of the
warranty, then the cost of returning the product would be to buyer’s account.
Groz Engineering Tools (P) Ltd.
Groz Net Industries
Village Kherki Daula, National Highway-8,
Gurgaon-122001, Haryana, INDIA
Tel +91.124.282.7734/40, 2827777
Fax 124.2827980, 2827986 +91.
E-Mail info@groz-tools.com
Url www.groz-tools.com
The GROZ name, GROZ logo and the mark are trademarks of Groz Engineering Tools
(P) Ltd., India ****
References
- tools.com | Buy Power Tools and Automotive Parts online
- GROZ TOOLS - Leading Manufacturer of Fluid Handling, Lubrication, Hand Tools in India
- GROZ TOOLS - Leading Manufacturer of Fluid Handling, Lubrication, Hand Tools in India
Read User Manual Online (PDF format)