BLUETTI 17.0303.0486-02 Portable Power Station User Manual
- June 15, 2024
- Bluetti
Table of Contents
BLUETTI 17.0303.0486-02 Portable Power Station
Thank You!
Thank you for making BLUETTI a part of your family.
From the very beginning, BLUETTI has tried to stay true to a sustainable
future through green energy storage solutions for both indoor and outdoor use
while delivering an exceptional eco-friendly experience for our homes and our
world. That’s why BLUETTI has a presence in 70+ countries and is trusted by
millions of customers across the globe.
Before You Begin
The information contained herein is subject to change without notice. For the latest version of this user manual, please visit https://www.bluettipower.eu/pages/manuals
- The user manual contains instructions and notes on the operation and use of this unit.
- BLUETTI recommends that you use genuine accessories from BLUETTI.
- BLUETTI shall not be responsible for any damage or expense that might result from the use of parts other than genuine parts from BLUETTI.
Safety Instructions
General Safety
BLUETTI products are developed to be safe and reliable. Please read this guide
for important safety information about your device. The guide is intended to
help you be more comfortable and productive while using this device. Failure
to follow these guidelines for proper setup, use, and care for your device may
cause damage to this unit and injury to yourself or others.
SAVE THESE INSTRUCTIONS
- Always operate or store the unit within the specified temperature range.
- DO NOT expose the unit to fire, liquids, sweat, dirt, or other contaminants, as that may cause an explosion or other safety risks.
- DO NOT place the unit on an unstable or tilted surface.
- Make sure the place where you are using the unit is well-ventilated and spacious.
- Keep away from children and pets.
- DO NOT ignore those warning signs on components or products made by manufacturers.
- DO NOT dismantle, cut, crush, puncture, or otherwise damage the unit in any way.
- DO NOT insert foreign objects into the fan, vents, ports, or other openings.
- NEVER use a damaged battery or component. Improper use or misuse of damaged batteries may cause damage to your device or injury to yourself as a result of battery fluid leakage, fire, overheating, or explosion.
- Use approved batteries and accessories ONLY. Improper use or use of unapproved or incompatible batteries or components may result in a risk of fire, explosion, or other hazards, and may invalidate any approval or warranty.
- Turn off the unit IMMEDIATELY in case of malfunction.
- Use a dry powder fire extinguisher in case of fire.
- DO NOT attempt to modify, or replace the internal battery or any other component of the unit by anyone other than qualified personnel. If necessary, take it to an authorized service center as incorrect reassembly may result in a risk of fire or electric shock.
Maintenance
- When not using the unit for extended periods of time, power off the unit and disconnect the AC charging cable from the outlet.
- Charge the unit to 50-70% SOC every 6 months for long-term storage.
- Clean the unit with a dry cloth gently and carefully.
Handling and Storage
- Use mechanical assistance as needed(e.g. trolleys and adjustable height workbenches).
- DO NOT stack anything on top of the unit either in storage or in use.
- Recommended storage temperature: -73-704° F/-25-40°C.
What’s In The Box
Standard Packaging
- Below accessories are not included in standard packaging and can be purchased separately at https://www.bluettipower.eu/
- AC Charging Cable: 59in/750cm.
- DC Input Cable: 59in/750cm. Aviation-MC4.
- Car Charging Cable: 79.7in/50cm.Cigarette Lighter Port-MC4.
- 30A RV Cable: Aviation-XT60, 37.5in/80cm; XT60-SPC45, 79.7in/50cm.
- Lead-acid Battery Charging Cable: 79.7in/50cm. Clamp-MC4.
- D300S PVVoltage Step Down Module : 65in/765cm(output cable). Cigarette Lighter-F to DC5521 Cable(24V}: 28.3in/72cm.
- 32A Aviation Plug: Used to obtain S000W AC output.Please refer to ACS00 32AAviation Plug Guide for details.
Note : All measurements are for reference only. Package details are subject to change without prior notice.
Product Overview
Diagram
- 24V Cigarette Lighter Port
- 72V/30A RV Port
- LCD Screen
- USB-C PD3.0
- 78W USB-A Port
- USB-A Port
- Sx73AAC Output (UK) 3x70A+2x7SAAC Output (AUS)
- 32A AC Output
- Wireless Charging Pad
- Power Button
- Battery Expansion Port
- AC Input
- DCl/D C2 Input
- Communication Port
Specifications
AC500
General
AC Output
DC Output
AC Input
DC Input
Note : If there’s only one B300S, the combo gets a maximum of 4500W output. When connecting B300S with the TS00 adapter or ACS00 to the grid, B300S is able to self-heat and get charged even at -4° F/-20°C.
Operation
Powering On/Off
- Startup and shutdown : Press and hold the power button on ACS00 or B300S to turn the combo on or off.
- AC/DC Output: Tap the ‘AC ON/OFF’ or ‘DC ON/OFF’ to enable or disable.
Note : Turn on the DC power to enable wireless charging. When connected to the grid or PV, the combo turns on automatically. The combo turns off automatically upon 4 hours:
- a : No input and output
- b : AC and DC output off
LCD Screen Homepage
This section displays the charge/discharge status and navigates to detailed product information.
- PV Input
- Battery Capacity
- Date/Time
- DC Load
- DCON/OFF
- ACON/OFF
- Grid Input
- AC Load
Settings
This section provides general setting configurations, including language,
AC/DC output and input, ECO mode machine type, system date/time, etc.
Note : Check all the settings before first use. AC frequency and voltage can only be adjusted after AC output is turned off. Voltage and frequency reference: EU/UK: 230V/50Hz AU: 240V/50Hz
Data
This section provides all basic information including product, inverter and
charger, battery, and alarm history.
Note :
- ‘Input & Output’ indicates the input and output status of this unit;
- ‘Battery Information’ indicates the connection status of the battery pack(s);
- ‘Alarm History’ records all alarms generated which can be manually deleted.
When on this mode, the AC output will automatically turn off after a 4-hour low(30W) or no load to save power.
Charging
AC Charging
-
Consider the specifications of the utility, AC outlet, and charging cable before setting the Max. Grid Input Current.
Note : The Max. Grid Input Current is set at l0A by default and only works when ACS00 connects to the grid. Email to BLUETTI Customer Service for password. -
Plug the ACS00 into the wall outlet via the AC charging cable.
Generator Charging
Connect ACS00 to the generator via the charging cable*.
- Sold separately.
Note : BLUETTI recommends an inverter generator that delivers at least S000W pure sine wave AC power.
Voltage and frequency limit:
- EU / UK : l95.5-253VAC/47-53
- Hz AU : 204-264VAC/47-53Hz
PV Charging
AC500 supports dual PV input with the DC input cable. Connect the solar panels
(in series or parallel) to AC500 and CHECK the PV connection on the LCD
screen.
Note:
Please make sure your solar panels at each input comply with:
- OCV : 12-150V
- Vmp :12-150V
- Power : 1500W Max.
E. g. Connect three BLUETTI PV350 solar panels in series to DCl or DC2.
- BLUETTI PV350: Voc=46.5V
- Vmp=37.5V
- Current=9.2A Max.
- Total: Voc=46.Sx3=739.5V
- Vmp=37.Sx3=772.5V
- Current=9.2A Max.
OCV :
Open circuit voltage, also for Voe. The maximum voltage that the solar panel
can produce with no load on it.
Vmp : Voltage at maximum power. The voltage is available when the panel is operating at its peak performance output. The roof panel can also charge the ACS00. If the panel’s OCV falls in 750-SS0V, please use the D300S to lower the voltage. Find details in the D300S PV Voltage Step-Down Module User Manual.
Car Charging
Connect the ACS00 to the vehicle plug-in cigarette lighter port via the DC
input cable and car charging cable.
Note : Set the ‘Others’ as DC7/DC2 input source to enable car charging. The Max. input current is 8.2A.
Lead-acid Battery Charging
Connect the ACS00 with the lead-acid battery via the DC input cable and lead-
acid battery charging cable.8
Note : Set the ‘Others’ as a DC7/DC2 input source to enable lead-acid battery charging. Clamp the positive connector(red) to the positive battery terminal and the negative(black) to the other. The Max. input current is 8.2A.
The lead-acid charging cable is for charging ACS00 ONLY.
Dual Charging
- Set the ‘PV’ as DC7/DC2 input source to enable AC/Generator+ PV Charging.
- Set the ‘Others’ as DC7/DC2 input source to enable AC/Generator+ Adapter/
- Car/Lead-acid Battery Charging.
- Turn on the ‘PV Parallel Enable’ to enable excessive PV charging(> 7500W, <150V).
Discharging
- 6744Wh* x DoD x 11-;- (load power)= charging time (estimated)
-
- Take the AC500+2*B300S combo as an example.
Note:
- DoD refers to the Depth of Discharge, and ri is the local inverter efficiency.
- DoD=95%, r,=90%.
- DoD may vary depending on the ambient operating temperature and discharge rate.
- Load power and charging time are measured in watts and hours.
Capacity Expansion
ACS00 supports up to 6 expansion batteries for a total of 8,432Wh capacity.
Connect ACS00 to B300S via the PlS0D battery expansion cable, or B300 via the
PlS0D to P090D cable. For more details, please refer to the B300S or B300 User
Manual.
Note : If there’s only one B300S connected, the combo delivers a maximum output of 4500W. To get 5000W output, please connect at least one expansion battery to each expansion port.
UPS
Plug the ACS00 + B300S combo into a standard wall outlet or tie them to the
grid. When the grid fails, the combo steps in and provides power for connected
devices.
Grid-tied UPS:
- The grid-tied UPS should be built by a qualified electrician. Please contact BLUETTI Customer Service for details.
ACS00 has 4 UPS modes-Standard, Time Control, PV Priority, and Customized UPS, and BLUETTl’s UPS mode guide is as follows:
- The standard UPS mode is good for regions with unstable grid power supply.
- The Time Control UPS mode will save your electricity bills by setting the charging and discharging time.
- The PV Priority UPS mode is better for regions with plenty of sunlight all year.
- The Customized UPS mode allows you to design your power supply system.
Please refer to BLUETTI Support on YouTube for detailed instructions.
BLUETTI APP
Download the app from the App Store or Google Play and follow the BLUETTI APP
INSTRUCTIONS to better control and monitor the ACS00 + B300S combo.
Power Lifting Mode
This mode can be enabled in the BLUETTI App. When in this mode, the combo can
power high drain pure resistive loads4\s6000W), while the rated output power
remains 5000W.
Note : Make sure the combo disconnects the grid and the B300S doesn’t overload. The ACS00 detects the resistance of devices and adjusts the output voltage automatically. The mode fails when the ACS00 drops below 70% of its rated voltage.
Includes heaters, irons, or any other devices consisting of heating elements only.
Technical Support
Should you require any further assistance, please do not hesitate to contact
BLUETTI Customer Service.
For more information, please visit:
YOUTUBE:
@ BLUETTI Support
@ BLUETTI Official
TWITTER :
@bluettUnc
FACEBOOK :
@ BLUETTI EU CLUB
@ Bluetti Europe
@bluetti.inc
INSTAGRAM :
@ bluetti_europe
@ bluetti_us
MAIL : service@bluetti.com
EU REP Address : Lindwurmstr.114, 80337 Mllnchen Germany Mail : logi@bluetti.de
UK REP Address : Unit 2, Northgate, Bolsover Business Park, Woodhouse Lane Chesterfield England S44 68D Mail : poweroak.eu@bluetti.com
Frequently Asked Questions
Can I use third-party solar panels to charge this product?
Yes, you can. As long as the specs of solar panels on DCl or DC2 input fall in
below range:
- OCV & Vmp: 72-lS0V
- Input Power : 7500W Max.
- With the same power connector (MC4)
Why can’t the unit be charged when the solar panels are connected?
Please follow the below steps:
- Press the ‘PV’ on the LCD screen to check whether the solar panels are connected successfully.
- Check the connection of solar panels and the PV input cable. If the symptom persists, please contact BLUETTI Customer Service.
How long will it take to switch the UPS?
20ms.
How to upgrade the firmware?
Connect the unit with the BLUETTI App, then you can over-the-air OTA.
Read User Manual Online (PDF format)