Keston Combi 2 Twin Flue Combi Boiler
When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specifications that we require. Do not use reconditioned or copied parts that have not been authorised by Keston. For the very latest copy of literature for specification and maintenance practices visit our website keston.co.uk where you can download the relevant information in PDF format.
INTRODUCTION
The Keston Combi2 is a combination boiler providing both central heating and instantaneous domestic hot water. Featuring full-sequence automatic ignition and fan-assisted combustion. Due to the high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point through a plastic waste pipe at the base of the boiler. A condensate ‘plume’ will also be visible at the flue terminal.
Safety
Current Gas Safety (Installation & Use) Regulations or rules in force. It is
the law that this appliance installation and any work carried out on the
appliance is carried out by a Gas Safe Registered engineer and in IE a
Registered Gas Installer (RGII) following the above Regulations. The
instructions in this booklet must be strictly followed, for safe and
economical operation of the boiler. Electricity Supply This appliance must be
earthed. Supply: 230 V ~ 50 Hz. The fusing should be 3 A.
Important Notes
- This appliance MUST NOT be operated without the casing correctly fitted and forming an adequate seal.
- If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes.
- If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a Gas Safe Registered Engineer. In IE a Registered Gas Installer (RGII)
- Under NO circumstances should any of the sealed components on this appliance be used incorrectly or tampered with.
- This appliance can be used by children 8 years and above. Also persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, provided they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
WEEE DIRECTIVE 2012/19/EU Waste Electrical and Electronic Equipment Directive
- At the end of the product life, dispose of the packaging and product in a corresponding recycle centre.
- Do not dispose of the unit with the usual domestic refuse.
- Do not burn the product.
- Remove the batteries.
- Dispose of the batteries according to the local statutory requirements and not with the usual domestic refuse.
All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. Both should be recorded in the Benchmark Commissioning Checklist. You can check your installer by calling Gas Safe Register direct on 0800 4085500. Keston Heating is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
BOILER OPERATION
Legend
- A. Domestic Hot Water Temperature Knob
- B. Central Heating Temperature Knob
- C. Hot Keys
- D. Boiler Status Display
- E. Burner On Indicator
- F. Mode Button
TO START THE BOILER
Start the boiler as follows:
- Ensure that all hot water taps are turned off.
- Switch on electricity to the boiler and check that all external controls, e.g. programmer and room thermostat, are on.
- Press the Mode Button until Ready or On is shown underneath both the Tap and Radiator symbols.
- Turn the Domestic Hot water temperature knob (A) clockwise until a 65°C target temperature is shown. Turn the Central Heating temperature Knob (B) clockwise until an 80°C target temperature is shown.
The boiler will commence ignition sequence, supplying heat to the central heating, if required.
Note. In normal operation the boiler status display (D) will display messages.
Boiler frost protection – boiler will fire if temperature is below 5ºC. During normal operation the burner on symbol (E) will remain illuminated when the burner is lit.If the boiler fails to light after five attempts the following fault messages will be displayed:
To restart the boiler, press Restart. The boiler will repeat the ignition sequence. If the boiler still fails to light consult a Gas Safe Registered Engineer and in IE a Registered Gas Installer (RGII).
OPERATION MODES
Winter Conditions – (Central Heating and Domestic Hot Water required) Press
the Mode Button until either Ready or On is shown under both the Tap and
Radiator symbols [ ]. The boiler will fire and supply heat to the radiators.
The domestic hot water preheat will operate with the preheat button set to
‘Preheat On’.
Summer Conditions – (Domestic Hot Water only required)
Press the Mode button until Ready or On is shown under the Tap symbol [ ] and
Off is shown under the Radiator symbol [ ]. OR Set the central heating demand
on the external controls to OFF. The domestic hot water preheat will operate
with the preheat button set to ‘Hot Water On’.
Boiler Off
Set the mode button (C) to ‘BOILER OFF’. The boiler mains power supply must be
left on to enable frost protection (see Frost Protection).
PREHEAT – DOMESTIC HOT WATER
The domestic hot water heat exchanger within the boiler can be preheated to
provide faster delivery of hot water at the tap. The boiler is factory set
with the preheat turned off to give standard hot water delivery and reduce gas
usage. If required, the preheat can be switched on for faster domestic hot
water delivery. It can be turned to either ‘On’ or ‘Timed’. With preheat
turned On, the boiler will operate periodically to maintain the domestic hot
water heat exchanger in a preheated condition at all times. If ‘Timed’ is
selected then the intelligent preheat function is active which learns the
usage pattern for domestic hot water over 7 days. It then fires the boiler to
maintain the temperature of the domestic hot water heat in the boiler, as
required to meet the predicted hot water draw-off. This improves the speed of
response for DHW whilst minimising the use of gas.
CONTROL OF WATER TEMPERATURE
Domestic Hot Water
The domestic hot water temperature is limited by the boiler controls to a
maximum temperature of 65ºC, adjustable via the domestic hot water temperature
knob (A). At low DHW draw off rates the maximum temperature may exceed 65ºC.
Approximate temperatures for domestic hot water:
Knob Setting Hot Water Temperature (approx.)
- Minimum 40ºC
- Maximum 65ºC
Due to system variations and seasonal temperature fluctuations domestic hot water flow rates/temperature rise will vary, requiring adjustment at the tap : the lower the flow rate the higher the temperature, and vice versa.
Central Heating
The boiler controls the central heating radiator temperature to a maximum of
80oC, adjustable via the central heating temperature knob (B). Approximate
temperatures for central heating:
Knob Setting Central Heating Radiator Temperature (approx.)
- Minimum 30ºC
- Maximum 80ºC
For economy setting [ ] refer to Efficient Heating System Operation.
EFFICIENT HEATING SYSTEM OPERATION
The boiler is a high-efficiency, condensing appliance that will automatically
adjust its output to match the demand for heat. Therefore gas consumption is
reduced as the heat demand is reduced. The boiler condenses water from the
flue gases when operating most efficiently. To operate your boiler efficiently
(using less gas) turn the central heating knob (B) until the leaf symbol is
shown [ ]. In winter periods it may be necessary to turn the knob towards the
‘MAX’ position to meet heating requirements. This will depend on the house and
radiators used. Reducing the room thermostat setting by 1ºC can reduce gas
consumption by up to 10%.
WEATHER COMPENSATION
When the Weather Compensation option is fitted to the system then the central
heating temperature knob (B) becomes
a method of controlling room temperature. Turn the knob clockwise to increase
room temperature and anti-clockwise to decrease room temperature. Once the
desired setting has been achieved, leave the knob in this position and the
system will automatically achieve the desired room temperature for all outside
weather conditions.
BOILER FROST PROTECTION
The boiler is fitted with frost protection that operates in all modes,
provided the power supply to the boiler is always turned on. If the water in
the boiler falls below 5ºC, the frost protection will activate and run the
boiler to avoid freezing. The process does not guarantee that all other parts
of the system will be protected. If a system frost thermostat has been
installed, the boiler must be set in winter mode, [ ], for the system frost
protection to run. If no system frost protection is provided and frost is
likely d ring a short absence from home it is recommended to leave the system
heating controls or built-in programmer (if fitted) switched on and running at
a reduced temperature setting. For longer periods, the entire system should be
drained.
BOILER RESTART
To restart the boiler, when directed in the listed fault messages press the
“Restart” button. The boiler will repeat its ignition sequence. If the boiler
still fails to start consult a Gas Safe Registered Engineer and in IE a
Registered Gas Installer
(RGII).
MAINS POWER OFF
To remove all power to the boiler the mains power switch must be turned off.
SYSTEM WATER PRESSURE
The system pressure gauge which can be viewed by lowering the drop down door,
indicates the central heating system pressure. If the pressure is seen to fall
below the original installation pressure of 1-2 bar over a period of time and
continue to fall then a water leak may be indicated. In this event re-
pressurise the system as shown below. If unable to do so or if the pressure
continues to drop a Gas Safe Registered Engineer and in IE a Registered Gas
Installer (RGII) should be contacted. THE BOILER WILL NOT OPERATE IF THE
PRESSURE HAS REDUCED TO LESS THAN 0.3 BAR UNDER THIS CONDITION.
To Top up the system:-
- Ensure both A & B handles (blue & green) are in closed position (as shown below)
- Remove the plug and cap and retain.
- Connect the filling loop to the Domestic Hot Water (DHW) inlet and tighten. Also, ensure that the other end of the filling loop is hand tight.
- Turn the Domestic Hot Water (DHW) Inlet A blue handle to the horizontal position.
- Ensuring no leaks are seen, gradually turn the filling loop handle (green) B to the horizontal position.
- Wait for the pressure gauge to reach 1 to 1.5 bar.
- Once pressure is reached turn valves A & B back to the closed position.
- Disconnect the filling loop, and replace the cap and plug. There can be some water spillage at this point.
Filling Positions shown
Top Up Positions shown
POINTS FOR THE BOILER USER
In line with our current warranty policy we would ask that you check
through the following guide to identify any problems external to the boiler
before requesting a service engineer’s visit. Should the problem be found to
be other than with the appliance we reserve the right to levy a charge for the
visit, or for any pre-arranged visit where access is not gained by the
engineer.
FOR ANY QUERIES PLEASE RING THE KESTON CONSUMER HELPLINE: 01482 443005 BOILER RESTART PROCEDURE – To restart the boiler press the restart button
FROZEN CONDENSATE DRAIN
This appliance is fitted with a siphonic condensate trap system that reduces
the risk of the appliance condensate from freezing. However, should the
condensate pipe to this appliance freeze, please follow these instructions:
- If you do not feel competent to carry out the defrosting instructions below please call your local Gas Safe Registered installer and in IE a Registered Gas Installer (RGII) for assistance.
- If you do feel competent to carry out the following instructions please do so with care when handling hot utensils. Do not attempt to thaw pipework above ground level.
If this appliance develops a blockage in its condensate pipe, its condensate will build up to a point where it will make a gurgling noise before locking out and displaying “Blocked Flue/Condensate” on the display. If the appliance is restarted it will make a gurgling noise prior to it locking out displaying “Ignition Lockout” on the display.
To unblock a frozen condensate pipe;
- 1. Follow the routing of the plastic pipe from its exit point on the appliance, through its route to its termination point. Locate the frozen blockage. It is likely that the pipe is frozen at the most exposed point external to the building or where there is some obstruction to flow. This could be at the open end of the pipe, at a bend or elbow, or where there is a dip in the pipe in which condensate can collect. The location of the blockage should be identified as closely as possible before taking further action.
- Apply a hot water bottle, microwaveable heat pack or a warm damp cloth to the frozen blockage area. Several applications may have to be made before it fully defrosts. Warm water can also be poured onto the pipe from a watering can or similar. DO NOT use boiling water.
- Caution when using warm water as this may freeze and cause other localised hazards.
- Once the blockage is removed and the condensate can flow freely, restart the appliance. (Refer to “To Start the boiler”)
- If the appliance fails to ignite, call your Gas Safe Registered engineer. In IE a Registered Gas Installer (RGII).
Preventative Solutions
During cold weather, set the central heating temperature knob (B) to “MAX”,
(Remember to return to original setting once cold spell is over). Place the
heating on continuous and turn the room thermostat down to 15ºC overnight or
when unoccupied. (Return to normal after cold spell).
GENERAL INFORMATION
BOILER PUMP
The boiler pump will operate briefly as a self-check once every 24 hours,
regardless of system demand.
MINIMUM CLEARANCES
Clearance of 165 mm above, 100 mm below, 2.5 mm at the sides and 450 mm at the
front of the boiler casing must be allowed for servicing.
BOTTOM CLEARANCE
Bottom clearance after installation can be reduced to 5 mm. This must be
obtained with an easily removable panel, to enable the system pressure gauge
to be visible and to provide the 100 mm clearance required for servicing.
SERVICE REQUEST FUNCTION
When the boiler has been installed for more than 1 year the following message
will appear on screen:
Press “Restart” to clear this message.
ESCAPE OF GAS
Should a gas leak or fault be suspected contact the National Gas Emergency
Service without delay. Telephone 0800 111 999.
Ensure that;
- All naked flames are extinguished
- Do not operate electrical switches
- Open all windows and doors
CLEANING
For normal cleaning simply dust with a dry cloth. To remove stubborn marks
and stains, wipe with a damp cloth and finish off with a dry cloth. DO NOT use
abrasive cleaning materials.
MAINTENANCE
The frequency of servicing will depend upon the installation condition and
usage but should be carried out at least annually by a Gas Safe Registered
Engineer. In IE a Registered Gas Installer (RGII)
TROUBLESHOOTING
DISPLAY FUNCTIONS – NORMAL OPERATION MODE
Normal Operation Screens
How to adjust Boiler Temperatures
The display scrolls through a maximum of 3 messages under any operational condition, as shown above
Note. The temperatures shown below are for illustration purposes only. The measured temperatures will be shown on the boiler.
DISPLAY FUNCTIONS – FAULT MESSAGES
At Keston we take our environmental impact seriously, therefore when installing any Keston by Ideal Heating product please make sure to dispose of any previous appliance in an environmentally conscious manner. Households can contact their local authority to find out how. See https://www.gov.uk /managing-your-waste-an-overview for guidance on how to efficiently recycle your business waste.
Technical Training
Our Expert Academy offers a range of training options designed and delivered
by our experts in heating. For details please visit: expert-academy.co.uk
Ideal Boilers Ltd., pursues a policy of
continuing improvement in the design and performance of its products. The
right is therefore reserved to vary specifications without notice.
Registered Office Ideal Boilers Ltd., National Avenue, Hull, East Yorkshire, HU5 4JN Tel 01482 443005 Registration No. London 322 137 EU Authorised Representative: Atlantic SFDT 44 Boulevard des Etats-Unis, 85 000 La Roche- Sur-Yon, France +33 (0)2 51 44 34 34 Keston by Ideal Heating Helpline: 01482 443005 Ideal Heating Parts: 01482 498665 keston.co.uk