Keston Combi 2 30kw and 35kw Output Combi Boiler Owner’s Manual
- October 30, 2023
- Keston
Table of Contents
Keston Combi 2 30kw and 35kw Output Combi Boiler Owner’s Manual
Features & specification
Offering first-class comfort in a compact, wall-hung appliance small enough to fit inside a standard kitchen cupboard*, the Keston Combi 2 range enables heating and hot water to be controlled independently, ensuring maximum comfort and efficiency.
Keston Combi 2 can be sited almost anywhere in the home, without the need for a separate tank. And because it connects to the unique Keston Twin Flue system, the boiler can be situated anywhere up to 27** metres from the flue outlet, helping to provide further flexibility when required.
Fully modulating, and with weather compensation, Keston Combi 2 provides excellent energy savings, making it the perfect choice for new or replacement installations alike.
THE FACTS
- 7 year warranty†
- Easy to see pressure gauge
- Large backlit display with user friendly controls
- Low lift weight
- Low component count maximising reliability
- Compact dimensions
- Twin flue up to 27m
- 50mm muPVC (PVC-C) solvent weld flue allowing simple, cost effective installations
- Weather compensator supplied as standard making Keston Combi 2 Boiler Plus compliant out of the box
- Pre-fitted filling loop
- Inbuilt frost protection
- Fully modulating
- LPG conversion kit available
7 year warranty when installed with a Keston 22mm System Filter and registered within 30 days of installation. 5 year parts & labour warranty as standard. Terms and conditions apply.
-
Please check
cupboard size prior to installation. -
For the maximum total equivalent flue length, please refer to
the installation manual. -
The only systems approved for this application are: Marley muPVC (PVC-C) Solvent Weld Waste System (50mm), Polypipe System 2000 muPVC (PVC-C) Solvent Weld Waste System (50mm), Polypipe Terrain Solvent Weld System (50mm) and Wavin Osma PVC-C Solvent Weld System (50mm). Please use the recommended Solvent Weld Cement for each system.
DIMENSION & CLEARANCES
Specification Data
CENTRAL HEATING | C30 | C35 |
---|---|---|
CH Output @ 70°C | Max | kW |
Max | kW | 6.1 |
CH Output @ 40°C | Max | kW |
Min | kW | 6.4 |
CH Input | Nett CV Max | kW |
Nett CV Min | kW | 6.1 |
CH Input | Gross CV Max | kW |
Gross CV Min | kW | 6.7 |
CH Gas Consumption | Max | m3 /h |
Min | m3 /h | 0.627 |
HOT WATER | C30 | C30 |
DHW Output | Max | kW |
DHW Input | Nett CV M | kW |
DHW Input | Gross CV Max | kW |
DHW Gas Consumption | m3 /h | 3.135 |
DHW Flow Rate at 35°C Rise | l/min | 12.4 |
DHW Specific Rate | l/min | 14.5 |
OTHERS | C30 | C35 |
Seasonal Efficiency | SEDBUK 2005 | % |
SEDBUK 2009/2012 | % | 89.6 |
Seasonal Space Heating Efficiency Class | A | A |
NOx Classification | Class 6 | Class 6 |
GENERAL DATA | C30 | C30 |
Max Horizontal Flue Length | m | 27 Flue / 2 Air |
Max Horizontal Flue Length (Parallel) | m | 18 Flue / 18 Air |
Flue Terminal Diameter | mm | 50 |
Gas Supply | 2H – G20 – 20mbar | |
Gas Supply Connection | 15mm copper compression | |
Injector Size | 15mm copper compression | |
Injector Sizemm | 4.65 | 4.90 |
Flow Connection (CH) | 22mm copper compression | |
Inlet Connection (DHW) | 22mm copper compression | |
Inlet Connection (DHW) | 15mm copper compression | |
Outlet Connection (DHW) | 15mm copper compression | |
Average Flue Temp – Mass Flow Rate (DHW) | 68°C – 13g/s | 73°C – 15g/s |
CO2 Content (±0.7) (Min CH) | % | 8.5 |
CO2 Content (±0.7) (Max DHW) | % | 9.3 |
Max Working Pressure (Sealed Systems) | bar (psi) | 2.5 (36.3) |
Max DHW Inlet Pressure | bar (psi) (kPa) | 10.0 (145) (1000) |
Min DHW Inlet Pressure | bar (psi) (kPa) | 1.3 (18.9) (130) |
Electrical Supply | 230V – 50Hz | |
Power Consumption | W | 93 |
Fuse Rating | External 3A / Internal: T4A HRC L250V | |
Water Content (CH) | l (gal) | 1.2 (0.26) |
Water Content (DHW) | l (gal) | 1.0 (0.22) |
Weight (Packed) | kg | 32.9 |
Maximum Installation Weight | kg | 28.6 |
Example Flue Installation
Keston Combi 2 C30 – Flue & Air Pipe Length
Flue Pipe Length [m]
acceptable flue operating area
Graph indicates maximum flue run 27m with 2m air. Also, 18m flue with 18m air pipe for parallel twin flue run.
C53 HORIZONTAL
Calculations:
Flue
Elbows 3 x 1m = 3m
Straights 4+6+1.5+1 = 12.5m
Total = 15.5m
Air
Elbows 2 x 1m = 2m
Straights 6+2+0.1+1 = 8.1m
Total = 10.1m.
Keston Combi 2 C35 – Flue & Air Pipe Length
Flue Pipe Length [m
acceptable flue operating area
Graph indicates maximum flue run 25m with 2m air. Also, 15m flue with 15m air pipe for parallel twin flue run.
C13 HORIZONTAL
Calculations:
Flue
Elbows 3 x 1m = 3m
Straights 4+3.5+1.5+2.5 = 11.5m
Total = 14.5m
Air
Elbows 4 x 1m = 4m
Straights 2+2+3.5+4+0.15 = 11.65m 2 4 6 8 10 12 14 16 18 20 22 24 26 28
Total = 15.65m
The following minimum clearances must be maintainedfor operation and
servicing.
Front of boiler – 450mm†
Sides of boiler – 2.5mm
Above boiler – 350mm, with 30mm above the flue
Below boiler – 100mm†
Dimensions:
KESTON COMBI 2
Height| 700mm
Width| 395mm
Depth| 278mm
- Or equivalent length.
- Can be reduced to 5mm for cupboard fit, 450mm required for servicing.