Keston Combi 2 30kw and 35kw Output Combi Boiler Owner’s Manual

October 30, 2023
Keston

Keston Combi 2 30kw and 35kw Output Combi Boiler Owner’s Manual
Keston Combi 2 30kw and 35kw Output Combi Boiler

Features & specification

Offering first-class comfort in a compact, wall-hung appliance small enough to fit inside a standard kitchen cupboard*, the Keston Combi 2 range enables heating and hot water to be controlled independently, ensuring maximum comfort and efficiency.

Keston Combi 2 can be sited almost anywhere in the home, without the need for a separate tank. And because it connects to the unique Keston Twin Flue system, the boiler can be situated anywhere up to 27** metres from the flue outlet, helping to provide further flexibility when required.

Fully modulating, and with weather compensation, Keston Combi 2 provides excellent energy savings, making it the perfect choice for new or replacement installations alike.

Keston Combi 2 30kw and 35kw Output Combi Boiler
specification

THE FACTS

  • 7 year warranty†
  • Easy to see pressure gauge
  • Large backlit display with user friendly controls
  • Low lift weight
  • Low component count maximising reliability
  • Compact dimensions
  • Twin flue up to 27m
  • 50mm muPVC (PVC-C) solvent weld flue allowing simple, cost effective installations
  • Weather compensator supplied as standard making Keston Combi 2 Boiler Plus compliant out of the box
  • Pre-fitted filling loop
  • Inbuilt frost protection
  • Fully modulating
  • LPG conversion kit available

7 year warranty when installed with a Keston 22mm System Filter and registered within 30 days of installation. 5 year parts & labour warranty as standard. Terms and conditions apply.

  • Please check
    cupboard size prior to installation.

  • For the maximum total equivalent flue length, please refer to
    the installation manual.

  • The only systems approved for this application are: Marley muPVC (PVC-C)  Solvent Weld Waste System (50mm), Polypipe System 2000 muPVC (PVC-C) Solvent Weld Waste System (50mm), Polypipe Terrain Solvent Weld System (50mm) and Wavin Osma PVC-C Solvent Weld System (50mm). Please use the recommended Solvent Weld Cement for each system.

DIMENSION & CLEARANCES

DIMENSION & CLEARANCES
DIMENSION & CLEARANCES

Specification Data

CENTRAL HEATING C30 C35
CH Output @ 70°C Max kW
Max kW 6.1
CH Output @ 40°C Max kW
Min kW 6.4
CH Input Nett CV Max kW
Nett CV Min kW 6.1
CH Input Gross CV Max kW
Gross CV Min kW 6.7
CH Gas Consumption Max m3 /h
Min m3 /h 0.627
HOT WATER C30 C30
DHW Output Max kW
DHW Input Nett CV M kW
DHW Input Gross CV Max kW
DHW Gas Consumption m3 /h 3.135
DHW Flow Rate at 35°C Rise l/min 12.4
DHW Specific Rate l/min 14.5
OTHERS C30 C35
Seasonal Efficiency SEDBUK 2005 %
SEDBUK 2009/2012 % 89.6
Seasonal Space Heating Efficiency Class A A
NOx Classification Class 6 Class 6
GENERAL DATA C30 C30
Max Horizontal Flue Length m 27 Flue / 2 Air
Max Horizontal Flue Length (Parallel) m 18 Flue / 18 Air
Flue Terminal Diameter mm 50
Gas Supply 2H – G20 – 20mbar
Gas Supply Connection 15mm copper compression
Injector Size 15mm copper compression
Injector Sizemm 4.65 4.90
Flow Connection (CH) 22mm copper compression
Inlet Connection (DHW) 22mm copper compression
Inlet Connection (DHW) 15mm copper compression
Outlet Connection (DHW) 15mm copper compression
Average Flue Temp – Mass Flow Rate (DHW) 68°C – 13g/s 73°C – 15g/s
CO2 Content (±0.7) (Min CH) % 8.5
CO2 Content (±0.7) (Max DHW) % 9.3
Max Working Pressure (Sealed Systems) bar (psi) 2.5 (36.3)
Max DHW Inlet Pressure bar (psi) (kPa) 10.0 (145) (1000)
Min DHW Inlet Pressure bar (psi) (kPa) 1.3 (18.9) (130)
Electrical Supply 230V – 50Hz
Power Consumption W 93
Fuse Rating External 3A / Internal: T4A HRC L250V
Water Content (CH) l (gal) 1.2 (0.26)
Water Content (DHW) l (gal) 1.0 (0.22)
Weight (Packed) kg 32.9
Maximum Installation Weight kg 28.6

Example Flue Installation

Keston Combi 2 C30 – Flue & Air Pipe Length

DIMENSION
Flue Pipe Length [m]

acceptable flue operating area

Graph indicates maximum flue run 27m with 2m air. Also, 18m flue with 18m air pipe for parallel twin flue run.

C53 HORIZONTAL

DIMENSION

Calculations:
Flue
Elbows 3 x 1m = 3m
Straights 4+6+1.5+1 = 12.5m
Total = 15.5m
Air
Elbows 2 x 1m = 2m
Straights 6+2+0.1+1 = 8.1m
Total = 10.1m.

Keston Combi 2 C35 – Flue & Air Pipe Length

DIMENSION

Flue Pipe Length [m

acceptable flue operating area

Graph indicates maximum flue run 25m with 2m air. Also, 15m flue with 15m air pipe for parallel twin flue run.

C13 HORIZONTAL

DIMENSION
Calculations:
Flue
Elbows 3 x 1m = 3m
Straights 4+3.5+1.5+2.5 = 11.5m
Total = 14.5m
Air
Elbows 4 x 1m = 4m
Straights 2+2+3.5+4+0.15 = 11.65m 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Total = 15.65m

The following minimum clearances must be maintainedfor operation and servicing.
Front of boiler – 450mm†
Sides of boiler – 2.5mm
Above boiler – 350mm, with 30mm above the flue
Below boiler – 100mm†

Dimensions:

KESTON COMBI 2

Height| 700mm
Width| 395mm
Depth| 278mm

  • Or equivalent length.
  • Can be reduced to 5mm for cupboard fit, 450mm required for servicing.