NuTone G8SD Series Single Stage Upflow Horizontal Gas Furnaces Owner’s Manual
- June 15, 2024
- NuTone
Table of Contents
- G8SD Series Single Stage Upflow Horizontal Gas Furnaces
- Technical Specifications
- Features and Benefits
- Gas Furnace Dimensions
- Gas Furnace Components
- Gas Furnace Design Series
- Model Identification Code
- Specifications
- FAQ
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
G8SD Series Single Stage Upflow Horizontal Gas Furnaces
Technical Specifications
G8SD Series
Single Stage Upflow/Horizontal Gas Furnaces
Induced Draft – 95+ AFUE, Ultra-Low NOx Input 50,000 – 100,000
Btuh
The gas furnace may be installed free standing in a utility
room, basement, or enclosed in an alcove or closet. The rounded
corner jacket provides a pleasing appliance appearance. Design
certified by CSA for application in the United States.
This furnace series is approved and certified by the SCAQMD and
the SJVAPC Districts in the state of California with NOx levels
below 14 ng/J when operating on natural gas.
Features and Benefits
- Ultra-Low NOx emissions
- High efficiency with AFUE of 95+
- Single stage heating
- Induced draft for improved combustion
- Free standing or enclosed installation options
- Rounded corner jacket for attractive appearance
Gas Furnace Dimensions
Model # | DIM. -A- | DIM. -B- | DIM. -C- | DIM. -D- |
---|---|---|---|---|
050U | 14 1/4 | 10 3/4 | 12 5/8 | 12 7/8 |
100U | 21 | 14 | 19 3/8 | 19 7/8 |
Note: Dimensions shown in Inches.
Gas Furnace Components
- Air / Fuel Mixing Tube
- Gas Burner Head
- Igniter / Flame Sensor Assembly
- Access In-Line Drain Assembly
- Sight Glass
- Primary Air Limit Switch
- Flexible Gas Line Pressure Switches
- Pressure Transducer
- Inducer Assembly
- Inducer Motor
- Pressure Switch
- Blower Door Switch
- Combustion Air Orifice Plate
- Gas Valve
- Pressure Switch
- Blower Limit Switch
- Motor Choke
Gas Furnace Design Series
S = Single Stage T = Two Stage M = Modulating
A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal D =
95% Upflow/Horizontal E = 96% Upflow K = 80% Downflow L = 92.1% /
95.1% Downflow M = 95% Downflow N = 96% Downflow Q = 96.4+% AFUE
Upflow/Horizontal
Model Identification Code
G 8 S D 050 U
Input Heating Capacity 050 = 50,000 100 = 100,000
T 23 A
1P
Powder Painted
First Revision
Cabinet Width A = 14.25 B = 17.50 C = 21.00 D = 24.50
Cooling Airflow 23 = 2-3 Tons 24 = 2-4 Tons 35 = 3-5 Tons 45 = 4-5
Tons
Motor Technology V = VSHE E = FSHE T = 5 Tap ECM
NOx C/D = 40 Ng/J or less NOx U = 14 Ng/J or less NOx
Specifications
G8SD MODEL NUMBERS| Input – Btuh (a)| Heating Capacity – BtuH| AFUE| Motor
H.P. – Speed – Type| Motor FLA| Rated Ext. SP – In. W.C.| Temperature Rise
Range – F| Shipping Weights| NOx
---|---|---|---|---|---|---|---|---|---
-050U-T23A1| 50000| 48000| 95.0| 3/4 – 9 – ECM| 8.4| 0.5| 30-60| 115| C/D = 40 Ng/J or less NOx U = 14 Ng/J or less NOx
-100U-T35C1| 100000| 95000| 95.0| 1 – 9 – ECM| 11| 0.5| 35-65| 153| C/D = 40 Ng/J or less NOx U = 14 Ng/J or less NOx
FAQ
Q: Can the gas furnace be installed in an enclosed
space?
A: Yes, the gas furnace can be installed in an enclosed space
such as a utility room, basement, alcove, or closet.
Q: What is the AFUE rating of this gas
furnace?
A: The gas furnace has an AFUE rating of 95+ which means it is
highly efficient in converting fuel to heat.
Q: Is this gas furnace approved for use in
California?
A: Yes, this gas furnace is approved and certified by the SCAQMD
and the SJVAPC Districts in California with NOx levels below 14
ng/J when operating on natural gas.
Q: What are the dimensions of the gas
furnace?
A: The dimensions vary depending on the model. Please refer to
the “Gas Furnace Dimensions” section for specific dimensions.
Q: What is the motor technology used in this gas
furnace?
A: The motor technology used in this gas furnace can be either
VSHE (Variable Speed High Efficiency), FSHE (Fixed Speed High
Efficiency), or 5 Tap ECM (Electronically Commutated Motor with 5
speed taps).
TECHNICAL SPECIFICATIONS
G8SD Series
Single Stage Upflow/Horizontal Gas Furnaces
Induced Draft – 95+ AFUE, Ultra-Low NOx Input 50,000 – 100,000 Btuh
The gas furnace may be installed free standing in a utility room, basement, or
enclosed in an alcove or closet. The rounded corner jacket provides a pleasing
“appliance appearance.” Design certified by CSA for application in the United
States.
This furnace series is approved and certified by the SCAQMD and the SJVAPC
Districts in the state of California with NOx levels below 14 ng/J when
operating on natural gas.
FEATURES and BENEFITS
· Ultra-low emissions: 65% less NOx than standard furnaces.
· 100% fired and tested: All units and each component are tested on the
manufacturing line.
· Best packaging in the industry: Unique corner post design assures product
will arrive to the homeowner dent free.
· Low Boy Height: Easy to apply in low ceiling applications, works well with
taller high SEER coils, easier to handle and install.
· Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger
assures a long life.
· 30 second blower delay at start-up: Assures a warm duct temperature at
furnace start-up. Adjustable blower off settings (60, 90, 120 and 180
seconds).
· 30 second post purge: Increases life of heat exchanger. · Hot surface
igniter: Innovative application of a silicon
nitride igniter. · Color coded wire harness: Designed to fit the
components, all with quick-connect fittings for ease of service and
replacement. · High static blowers: All models equipped with high static
blowers. · 60 second cooling cycle blower-off delay (TDR): increases cooling
performance when matched with a Nortek Global HVAC coil. · Flexible category
IV venting system: May be vented with dedicated venting system or common
vented with other category one appliances. · High efficiency blower kits:
Maximize efficiencies and provide better temperature control, humidity control
and air distribution. · Multi-speed direct drive blower: Energy-efficient,
brushless DC (ECM). Designed to give a wide range of cooling capacities. ·
Diagnostic lights for easy troubleshooting without counting flashes: Dedicated
light for flame signal strength and 2 lights in combination to indicate all
other fault codes with easy to recognize states without counting flashes. ·
Integrated control board: Incorporates connections for electronic air cleaner
and humidifier. Ergonomically located for ease of service. · Two piece door
design: Enhances furnace appearance and uses captured screws to prevent
loosing door screws. · Furnace Air Leakage: These furnaces comply with Energy
Star cabinet air leakage requirement of less than or equal to 2%. Keep the
conditioned air flowing to where it’s needed.
2
GAS FURNACE DIMENSIONS
ULTRA-LOW NOX UPFLOW/HORIZONTAL FURNACE
MODEL #’S
DIM. -A-
DIM. -B-
050U 100U
14 1/4 21
10 3/4 14
NOTE: Dimensions shown in Inches.
DIM. -C-
12 5/8 19 3/8
DIM. -D-
12 7/8 19 7/8
TOP VIEW B
FLANGES
19
BOTTOM VIEW C
Front Brace
Bottom Panel
23 1/2
34 1/2 17 1/4 17 7/8
2 3/4 22 1/2
25 3/8 22 1/2 Vent pipe (Ø 3″)
28 LEFT SIDE
3 1/4
T-stat (Ø 7/8)
Electric (Ø 7/8)
Gas (Ø 1 5/8)
Combustion Air
A
T-stat (Ø 7/8)
Vent pipe (Ø 3″)
Electric (Ø 7/8)
22 1/2 Gas (Ø 1 5/8)
24 7/8
Condensate (Ø 1 1/16)
FRONT VIEW
4 Knockouts
(both sides)
15
1
Cond. (Ø 1 1/16)
23 RIGHT SIDE
1 1/4
GAS FURNACE COMPONENTS
Air / Fuel Mixing Tube
Gas Burner Head
Igniter / Flame Sensor Assembly
Access
In-Line Drain Asssembly
Sight Glass
Primary Air Limit Switch
Flexible Gas Line Pressure Switches
Pressure Transducer
Inducer Assembly
Inducer Motor
Pressure Switch
Blower Door Switch
Combustion Air Orifice Plate
Gas Valve
Pressure Switch
Blower Limit Switch
Motor Choke
3
Gas Furnace
Design Series
S = Single Stage T = Two Stage M = Modulating
A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal D = 95%
Upflow/Horizontal E = 96% Upflow K = 80% Downflow L = 92.1% / 95.1% Downflow M
= 95% Downflow N = 96% Downflow Q = 96.4+% AFUE Upflow/Horizontal
MODEL IDENTIFICATION CODE
G 8 S D 050 U
Input Heating Capacity 050 = 50,000 100 = 100,000
T 23 A
1P
Powder Painted
First Revision
Cabinet Width A = 14.25 B = 17.50 C = 21.00 D = 24.50
Cooling Airflow 23 = 2-3 Tons 24 = 2-4 Tons 35 = 3-5 Tons 45 = 4-5 Tons
Motor Technology V = VSHE E = FSHE T = 5 Tap ECM
NOx C/D = 40 Ng/J or less NOx U = 14 Ng/J or less NOx
SPECIFICATIONS
G8SD MODEL NUMBERS Input – Btuh (a) Heating Capacity – BtuH AFUE Motor H.P. – Speed – Type Motor FLA Rated Ext. SP – In. W.C. Temperature Rise Range – F Shipping Weights NOx
-050U-T23A1 -100U-T35C1
50000
100000
48000
95000
95.0
95.0
3/4 – 9 – ECM 1 – 9 – ECM
8.4
11
0.5
0.5
30-60
35-65
115
153
<14ng/J
<14ng/J
4
ACCESSORIES
Description Side return filter kit
G8SD KITS
SKU 541036
AIRFLOW DATA
MODEL NAME/ HEATING INPUT
G8SD
-050U-T23A*
RETURN AIR VIA:
MOTOR SPEED
Bottom Side
Tap 9 Tap 8 Tap 7 Tap 6
Tap 5
Tap 4 Tap 3 Tap 2 Tap 1 Tap 9 Tap 8 Tap 7 Tap 6 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1
HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
TORQUE SETTING
0.1
CFM
RISE
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.2
0.3
0.4
CFM
RISE
CFM
RISE
CFM
RISE
51.0 42.0 33.0 27.6
22.5
970
45
935
47
915
48
880
50
18.2
875
50
835
53
810
54
770
57
16.2
835
53
795
55
765
57
9.5
6.0
51.0
42.0
33.0
27.6
22.5
935
47
915
48
880
50
845
52
18.2
850
52
815
54
780
56
745
59
16.2
815
54
775
57
740
59
9.5 6.0
MODEL NAME/ HEATING INPUT
G8SD
RETURN AIR VIA:
MOTOR SPEED
-050U-T23A*
Tap 9
Bottom Only
Tap 8 Tap 7 Tap 6 Tap 5 Tap 4 Tap 3
Tap 2
Tap 1
Tap 9
Tap 8
Tap 7
Tap 6 Left Side Only
Motor
Tap 5
Tap 4
Tap 3
Tap 2 Tap 1
COOLING AIRFLOW (CFM)
TORQUE SETTING
51.0 42.0 33.0 27.6 22.5 18.2 16.2 9.5 6.0 51.0 42.0 33.0 27.6 22.5 18.2 16.2
9.5 6.0
0.1
CFM
1,420 1,310 1,180 1,085 970 875 835 650 550 1,410 1,290 1,145 1,045 935 850
815 605 495
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.2
0.3
0.4
0.5
0.6
CFM
CFM
CFM
CFM
(CFM)
1,395 1,270 1,145 1,050
935
835 795 590 485 1,380 1,260 1,115 1,015 915 815 775 575 470
1,360 1,245 1,115 1,015
915
810 765 560 450 1,350 1,230 1,090 980 880 780 740 530 410
1,330 1,215 1,085 985
880
770 725 520 405 1,315 1,195 1,055 950 845 745 700 495 365
1,300 1,180 1,050 950
845
735 690 465 330 1,285 1,160 1,030 920 805 715 675 445 320
1,280 1,145 1,020 920
810
700 655 430 290 1,255 1,135 995 885 775 665 620 390 260
0.7
(CFM)
1,245 1,120 990 890 780 665 615 380 250 1,225 1,100 960 855 745 625 575 325
160
0.8
(CFM)
1,220 1,095 955 855 745 630 580 340 195 1,200 1,070 920 825 695 585 540 235
NOTES: 1. To comply with government mandated efficiency standards, two
openings are required for airflows above 1,600 CFM. 2. Data is shown without
filter. 3. Temperature rises in the table are approximate. Actual temperature
rises may vary. 4. Individual cells shaded in gray indicate a temperature rise
outside of the recommended range. 5. To comply with government mandated
efficiency standards, speed settings shaded in gray are not allowed in HEAT
mode. 6. The “” denotes the factory COOL setting, “” denotes the factory
HEAT setting, and “” denotes factory FAN setting. If the Alternate
speed is to be used, the speed tap must be adjusted at the blower motor plug.
0.5
CFM
RISE
845
52
735
60
805
55
5
AIRFLOW DATA
HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
MODEL NAME/ HEATING INPUT
G8SD
RETURN AIR VIA:
MOTOR SPEED
TAP
9 8 7 6 Bottom Only 5 4 3 2 1 9 8 7 6 G8SD-100U-T35C Side Only 5 4 3 2 1 ** 9 8 7 6 Side + Bottom 5 4 3 2 1 ***
0.1 CFM RISE — —– —– –1,850 48 1,745 50 1,480 59 1,315 1,140 1,025 — —– —– –1,785 49 1,690 52 1,435 61 1,265 1,095 980 — —– —– –1,865 47 1,760 50 1,495 59 1,325 1,175 1,040
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.2
0.3
0.4
CFM RISE CFM RISE CFM RISE
— — — — — —
— — — — — —
— — — — — —
1,790 49 1,745 50 1,700 52
1,690 52 1,645 53 1,590 55
1,420 62 1,360 65 1,300
1,245
1,170
1,100
1,055
975
890
920
830
745
— — — — — —
— — — — — —
— — — — — —
1,740 51 1,690 52 1,640 54
1,640 54 1,595 55 1,540 57
1,375 64 1,300
1,250
1,190
1,140
1,070
1,015
945
870
905
835
740
— — — — — —
— — — — — —
— — — — — —
1,810 49 1,755 50 1,695 52
1,705 52 1,655 53 1,595 55
1,430 62 1,365 64 1,290
1,245
1,175
1,095
1,065
965
900
930
850
750
0.5 CFM RISE — —– —– –1,650 53 1,535 57 1,230 1,025 820 690 — —– —– –1,590 55 1,490 59 1,195 1,005 790 665 — —– —– –1,645 53 1,535 57 1,235 1,035 810 680
NOTES: 1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 2. Data is shown without filter. 3. Temperature rises in the table are approximate. Actual temperature rises may vary. 4. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 5. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 6. The “” denotes the factory (default) COOL setting, “” denotes the factory (default) HEAT setting, and “” denotes the factory (default) FAN setting. If an alternate speed is to be used, refer to the installation instructions for Speed Tap Selection.
6
AIRFLOW DATA
COOLING AIRFLOW (CFM)
MODEL NAME/ HEATING INPUT
G8SD
RETURN AIR VIA:
MOTOR SPEED
TAP
0.1 CFM
EXTERNAL STATIC PRESSURE (IN. W.C.) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM (CFM) (CFM) (CFM)
G8SD-100UT35C*
9
8
7
6 *
Bottom Only
5 **
4
3
2
1 ***
9
8
7
6 *
Side Only 5 **
4
3
2
1 ***
9
8
7
6 *
Bottom + Side
5 **
4
3
2
1 ***
2,250 2,055 1,900 1,850
1,745
1,480 1,315 1,140 1,025 2,155 1,980 1,835 1,785 1,690 1,435 1,265 1,095 980
2,245 2,080 1,915 1,865 1,760 1,495 1,325 1,175 1,040
2,250 2,010 1,845 1,790
1,690
1,420 1,245 1,055 920 2,110 1,940 1,785 1,740 1,640 1,375 1,190 1,015 905
2,195 2,030 1,875 1,810 1,705 1,430 1,245 1,065 930
2,190 1,970 1,795 1,745
1,645
1,360 1,170 975 830 2,075 1,890 1,740 1,690 1,595 1,300 1,140 945 835 2,155
1,980 1,820 1,755 1,655 1,365 1,175 965 850
2,130 1,900 1,750 1,700
1,590
1,300 1,100 890 745 2,020 1,850 1,685 1,640 1,540 1,250 1,070 870 740 2,095
1,930 1,765 1,695 1,595 1,290 1,095 900 750
2,080 1,840 1,700 1,650
1,535
1,230 1,025 820 690 1,975 1,805 1,635 1,590 1,490 1,195 1,005 790 665 2,065
1,880 1,715 1,645 1,535 1,235 1,035 810 680
2,025 1,790 1,650 1,595
1,485
1,165 975 765 625 1,965 1,760 1,585 1,540 1,440 1,140 935 715 590 2,070 1,820
1,655 1,585 1,480 1,170 970 775 610
1,975 1,730 1,575 1,535
1,420
1,110 915 705 580 1,950 1,710 1,545 1,490 1,390 1,080 875 665 525 2,015 1,765
1,600 1,530 1,430 1,115 910 705 560
1,915 1,675 1,520 1,470
1,365
1,055 860 660 500 1,900 1,650 1,495 1,440 1,340 1,020 815 615 440 1,950 1,705
1,535 1,485 1,370 1,065 855 635 475
NOTES: 1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 2. Data is shown without filter. 3. Temperature rises in the table are approximate. Actual temperature rises may vary. 4. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 5. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 6. The “” denotes the factory (default) COOL setting, “” denotes the factory (default) HEAT setting, and “” denotes the factory (default) FAN setting. If an alternate speed is to be used, refer to the installation instructions for Speed Tap Selection.
7
GENERAL TERMS OF LIMITED WARRANTY Nortek Global HVAC, LLC will furnish a
replacement for any part of this product which fails in normal use and service
within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and
conditions, see your local installer or contact the Nortek Global HVAC, LLC
warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (10/2020)
628F-1020
www.nutonehvac.com
NuTone ® trademark used under license. © Nortek Global HVAC, LLC. All Rights Reserved.