FISHER PAYKEL RDV3 48 Inch Freestanding Dual Fuel Range with 8 Burners Installation Guide
- June 15, 2024
- Fisher & Paykel
Table of Contents
- RDV3 48 Inch Freestanding Dual Fuel Range with 8 Burners
- SAFETY AND WARNINGS
- MODEL IDENTIFICATION
- PARTS SUPPLIED FOR INSTALLATION
- CLEARANCE DIMENSIONS – ALL MODELS
- INSTALLATION SCENARIOS AND USE OF BACKGUARDS
- VENTILATION REQUIREMENTS
- ELECTRICAL CONNECTION
- GAS CONNECTION
- TOE KICK INSTALLATION
- INSTALLING THE ANTI-TIP BRACKET
- Documents / Resources
RDV3 48 Inch Freestanding
Dual Fuel Range with 8 Burners
Installation Guide
RDV3 48 Inch Freestanding Dual Fuel Range with 8 Burners
PROFESSIONAL RANGE
RDV3, RHV3 & RIV3 models
INSTALLATION GUIDE US CA
SAFETY AND WARNINGS
WARNING!
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
NEVER use this appliance as a space heater to heat or warm the room. Doing so
may result in carbon monoxide poisoning and overheating of the appliance.
What to Do if you Smell Gas
- Do not try to light any appliance.
- Do not touch any electrical switch.
- Do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING!
| Electric Shock Hazard
Failure to follow this advice may result in electrical shock or death.
• Before carrying out any work on the electrical section of the appliance, it
must be disconnected from the mains electricity supply.
• Connection to a good ground wiring system is absolutely essential and
mandatory.
• Alterations to the domestic wiring system must only be made by a qualified
electrician
WARNING!
| Cut Hazard
Failure to use caution could result in injury.
• Take care: some edges are sharp.
WARNING!
| Failure to do so can result in death or serious burns to children of
adults.
• To reduce the risk of tipping the appliance, the appliance must be secured
by properly installed anti-tip device packed with the appliance.
• A child or adult can tip the range and be killed.
• Install the anti-tip device to the structure by fastening the supplied
bracket to the floor and wall following the instructions for installing the
anti-tip device.
• Engage the anti-tip device.
• Re-engage the anti-tip device if the range is moved.
WARNING!
**| Extremely Heavy
** Failure to follow this advice may result in damage or personal injury.
• Proper equipment and adequate manpower must be used in moving the range to
avoid personal injury or damage to the unit or the floor. The unit is heavy
and rests on adjustable steel legs.
WARNING!
To avoid hazard, follow these instructions carefully before installing or
using this appliance.
- Please make this information available to the person installing the appliance – doing so could reduce your installation costs.
- Save these instructions for the local inspectors use.
- This range is to be installed and connected to the electricity supply only by an authorized person.
- If the installation requires alterations to the domestic electrical system, call a qualified electrician. The electrician should also check that the socket cable section is suitable for the electricity drawn by the range.
- Service should only be done by authorized technicians. Technicians must disconnect the power supply before servicing this appliance.
- The range must be grounded.
- Installation must comply with your local building and electricity regulations.
- This appliance must be installed and connected to the mains power supply only by a suitably qualified person according to these installation instructions and in compliance with any applicable local building and electricity regulations. Failure to install the appliance correctly could invalidate any warranty or liability claims.
- Ensure the installer shows the customer where the gas supply shut-off valve is located.
- If the power supply cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid a hazard.
- A circuit breaker is recommended.
- Do not use adaptors, reducers or branching devices to connect the oven to the mains electricity supply, as they can cause overheating and burning.
- Improper installation, adjustment alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before using, installing or servicing this appliance.
- A risk of the appliance tipping over exists if the appliance is not installed in accordance with installation instructions.
- DO NOT obstruct the flow of combustion or ventilation air to the appliance. Be sure a fresh air supply is available.
- California Proposition 65 – The burning of gas cooking fuel generates some by-products which are known by the State of California to cause cancer or reproductive harm. California law requires businesses to warn customers of potential exposure to such substances. To minimize exposure to these substances, always operate this unit according to the manufacturer’s instructions and provide good ventilation to the room when cooking with gas.
- Check local building codes for the proper method of range installation. Local codes vary. Installation, electrical connections, and grounding must comply with all applicable codes. In the absence of local codes, the range should be installed in accordance with the latest edition of National Fuel Gas Code ANSI Z223.1 and National Electrical Code ANSI / NFPA 70.
- In Canada: Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/ or local codes.
- Be sure that the unit being installed is set up for the kind of gas being used. The gas range is shipped from the factory set and adjusted for Natural Gas or LP (propane), depending on the specific model ordered. Verify that the range is compatible with the gas at the installation site before proceeding further. Return range to dealer if the unit is not set for site gas supply.
- The appliance must not be installed behind a decorative door in order to avoid overheating.
- Do not lift the range by the door handle. Doing so may damage the product.
- Before use, ensure all doors are correctly installed.
- Two persons are required to move the product safely to the installation location.
IMPORTANT!
SAVE THESE INSTRUCTIONS
The models shown in this installation guide may not be available in all
markets and are subject to change at any time. For current details about model
and specification availability in your country, please go to our website
www.fisherpaykel.com or contact your local
Fisher & Paykel dealer.
MODEL IDENTIFICATION
PARTS SUPPLIED FOR INSTALLATION
PRODUCT DIMENSIONS – 30″ MODELS
| PRODUCT DIMENSIONS| 30″ MODELS
IN| MM
---|---|---|---
A| Overall height of range
(from floor to cooktop, excl. pan supports and vent trim)| min 35 3/4
max 36 3/4| min 908
max 933
B| Overall width of range| 29 7/8| 759
C| Overall depth of range (excl. handle and dials)| 29 1/8| 740
Ⓓ| Depth from rear of chassis to cabinetry face – projecting control panel| 25
3/8| 644
E| Depth from rear of chassis to cabinetry face – flush control panel| 27
11/16| 703
F| Height from top of cook surface to top of pan supports| 1 9/16| 40
G| Height from top of cook surface to top of l vent trim (if fitted)| 1 3/4|
45
| l angled vent trim (if fitted)| 3 1/2| 90
H| Height from top of cook surface to bottom of chassis| 35 1/4| 895
---|---|---|---
PLAN| Adjustable feet height| min 1/2 max 1 1/2| min 13
max 38
J| Depth of open door to front control panel| 19 1/8| 486
PRODUCT DIMENSIONS – 36″ MODELS
| PRODUCT DIMENSIONS| 36″ MODELS
IN| MM
---|---|---|---
A| Overall height of range| min 35 3/4| min 908
| (from floor to cooktop, excl. pan supports and vent trim)| max 36 3/4| max
933
B| Overall width of range| 35 7/8| 911
C| Overall depth of range (excl. handle and dials)| 29 1/8| 740
Ⓓ| Depth from rear of chassis to cabinetry face – projecting control panel| 25
3/8| 644
C E| Depth from rear of chassis to cabinetry face –
flush control panel| 27 11/16| 703
F| Height from top of cook surface to top of pan supports| 1 9/16| 40
G| Height from top of cook surface to top of vent trim (if fitted)| 1 3/4|
45
| l angled vent trim (if fitted)| 3 1/2| 90
H| Height from top of cook surface to bottom of chassis| 35 1/4| 895
I| Adjustable feet height| min 1/2 max 1 1/2| min 13 max 38
J| Depth of open door to front control panel| 19 1/8| 486
PRODUCT DIMENSIONS – 48″ MODELS
| PRODUCT DIMENSIONS| 48″ MODELS
IN| MM
---|---|---|---
A| Overall height of range| min 35 3/4| min 908
B| (from floor to cooktop, excl. pan supports and vent trim)| max 36 3/4| max
933
C| Overall width of range| 47 7/8| 1216
Ⓓ| Overall depth of range (excl. handle and dials)| 29 1/8| 740
E| Depth from rear of chassis to cabinetry face – projecting control panel| 25
3/8| 644
C| Depth from rear of chassis to cabinetry face – flush control panel| 27
11/16| 703
F| Height from top of cook surface to top of pan supports| 1 9/16| 40
G| Height from top of cook surface to top of vent trim (if fitted)| 1 3/4| 45
| l angled vent trim (if fitted)| 3 1/2| 90
H| Height from top of cook surface to bottom of chassis| 35 1/4| 895
I| Adjustable feet height| min 1/2 max 1 1/2| min 13 max 38
J| Depth of open door to front control panel| 19 1/8| 486
CLEARANCE DIMENSIONS – ALL MODELS
| 30″ MODELS| 36″ MODELS| 48″ MODELS
---|---|---|---
CLEARANCE DIMENSIONS| IN| MM| IN| MM| IN| MM I
(…9 Minimum width of ventilation hood installed above range| 30| 762| 36| 914|
48| 12191
C) Minimum vertical distance between countertop and cabinet extending above
counter| 18| 457| 18| 457| 18| 4571
0 Minimum clearance from left and right edge of range to nearest vertical
combustible surface| 12| 305| 12| 305| 12| 3051
(D Minimum clearance from cooking surface to:| | | | | |
•combustible surface centered above the cooking surface| 54| 1372| 54| 1372|
54| 1372
•combustible covering for ventilation hood centered above the cooking surface|
36| 914| 36| 914| 36| 914
•non-combustible surface centered above the cooking surface| 30| 762| 30| 762|
30| 762
Ci) Maximum overall depth of overhead cabinetry| 13| 330| 13| 330| 13| 3301
CD Width of cabinetry opening| 30| 762| 36| 914| 48| 12191
0 Maximum height from floor to countertop:| | | | | |
– for level counter| 35 3/4| 908| 35 3/4| 908| 35 3/4| 908
– with range levelling legs fully extended| 36 3/4| 933| 36 3/4| 933| 36 3/4|
933
0 Maximum depth from wall to cabinetry face:| | | | | |
•projecting control panel| 25 1/8| 638| 25 V8| 638| 25 1/8| 638
•flush control panel| 27 11/16| 703| 27 11/16| 703| 27 11/16| 703
Note:
- If the range is to be placed adjacent to cabinets, the clearances shown are required. The same clearances apply to island installations.
- The range can be placed in various positions with respect to the cabinet front, with the control panel either flush or projecting, depending on the cabinetry depth.
- The electrical and gas supply should be within the zones shown in the following diagrams
- Any openings in the wall behind the range and in the floor under the range must be sealed.
- Always keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
- Do not obstruct the flow of combustion and ventilation air to the unit.
*Non-combustible surfaces: as defined in ‘National Fuel Gas Code’ (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less than 6″ (152mm) must be approved by the local codes and/or by the local authority having jurisdiction.
INSTALLATION SCENARIOS AND USE OF BACKGUARDS
Wall installation
Island installation
*Non-combustible surfaces: as defined in ‘National Fuel Gas Code’ (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less than 6″ (152mm) must be approved by the local codes and/or by the local authority having jurisdiction.
INSTALLATION SCENARIOS AND USE OF BACKGUARDS
Important notes
- All ranges come fitted standard with with an Integral Flat Vent Trim.
- There are three different blackguards available for purchase:
- Range Mount Low Backguard
- Wall Mount High Backguard with Low Shelf
- Wall Mount High Backguard with High Shelf, also supplied with an Angled Vent Trim.
- For installations against non-combustible* surfaces only, you may install the range without a blackguard or choose any of the three blackguards.
- For installations close to combustible surfaces (above the cooking surface), without a blackguard, there must be a minimum 6″ (152mm) clearance (see Scenario 2 or 7 opposite).
- For installations immediately against combustible surfaces (above the cooking surface), you must purchase and fit the Wall Mount High Blackguard High Shelf and Angled Vent Trim (see Scenario 5 opposite).
- The cooking surface must sit flush or above the adjacent countertop level.
Blackguard model numbers
RANGE| RANGE MOUNTLOW BACKGUARD| WALL MOUNT HIGH
BACKGUARD LOW SHELF| WALL MOUNT HIGH
BACKGUARD HIGH SHELF| BACKGUARD WIDTH
IN| MM
---|---|---|---|---|---
30″ models| BGRV2-1230| BGRV2-3030| BGRV3-3030H| 29 7/8| 759
36″ models| BGRV2-1236| BGRV2-3036| BGRV3-3036H| 3 5 7/ 8| 911
48″ models| BGRV2-1248| BGRV2-3048| BGRV3-3048H| 47 7/ 8| 1216
Note: For more information on Backguard installation, refer to the separate instructions provided with your Backguard. Backguard Installation Instructions can also be downloaded from our website, www.fisherpaykel.com
VENTILATION REQUIREMENTS
A suitable ventilation hood must be installed above the range. The following
chart indicates the minimum blower capacity recommended for hood ventilation.
Installation recommendations
Installation recommendations
VENTILATION UNIT| STANDARD WALL INSTALLATION| ISLAND
INSTALLATION
Hood| 23″ (548 mm) deep x unit width| 30″ (762mm) deep x (unit width + 4″
(102mm))
Blower 48″ Range| 1200 CFM| 1200 CFM
36″ Range| 600 – 1200 CFM| 600 – 1200 CFM
30″ Range| 600 CFM| 600 CFM
IMPORTANT
- Ventilation hoods and blowers are designed for use with single wall ducting. However, some local building codes or inspectors may require double wall ducting and/or a damper. Consult local building codes and/or local agencies, before starting, to ensure that hood and duct installation will meet local requirements.
- Hood blower speeds should be variable to reduce noise and loss of heated or air conditioned household air when maximum ventilation is not required. Normally, the maximum blower speed is only required when using the grill or the self-cleaning cycle.
- For best smoke elimination, the lower edge of the hood should be installed a minimum of 30″ (762mm) to a maximum of 36″ (914mm) above the range cooking surface.
- If the hood contains any combustible materials (eg a wood covering) it must be a minimum of 36″ (914mm) above the cooking surface.
- Due to a high volume of ventilation air, a source of make-up air (outside replacement air) is recommended. This is particularly important for tightly sealed and insulated homes. A reputable heating and ventilating contractor should be consulted.
UNPACKING THE RANGE
- REMOVE TOE KICK
- REMOVE DOORS
- REMOVE FROM PALLET Front bolts
At the front of the product, remove the two shipping bolts made visible by removing the toe kick.
Rear bolts
To access the two shipping bolts at the rear of the product, unscrew the lower guard panel. Remove the rear bolts to release.
IMPORTANT!
Two people required.
Before restraining the product to the hand truck, place two cardboard packing
sheets (shipped with the product) against both side panels as shown.
Tilt the product and insert hand truck.
DO NOT insert the hand truck to the front of the product.
Restrain the product and packing sheets to the hand truck using straps and
tilt onto hand truck. Set pallet aside and pull product to the installation
location.
REMOVING AND REFITTING THE OVEN DOOR(S)
IMPORTANT!
- Take care, the oven door is heavy.
- Do not lift the oven door by its handle. Doing so may damage the door.
- Ensure the oven and the door are cool before you begin to remove the door.
- Before removing the door, ensure there is a large enough clear, protected surface in the kitchen to rest the door on.
REMOVE DOOR
REFIT THE DOOR
Holding the door at 45°, carefully align the hinge tongues with the hinge slots. Push the door in until you feel the latches locate into position on each side. Open the door completely and ensure both hinges are secured by the correct notches. Rotate the locks up into the closed position ensuring they rest inside the slots completely. Note: Incorrect installation will prevent door from correctly sealing. Close the oven door ensuring that when closed, the door is vertical and parallel to any surrounding cabinetry.
LOCATION OF ELECTRICAL AND GAS SUPPLY
SUPPLY AREA DIMENSIONS | RDV3 |
---|---|
IN | MM |
A Distance from either edge of range to supply area | 1 1/2 |
B Height of gas and electrical supply areas (from floor) | 6 |
C Depth of supply areas (ie maximum protrusion of gas connection from wall) | |
2 | 51 |
*Regulator location may vary depending on model
| RGV3
---|---
SUPPLY AREA DIMENSIONS
IN| MM
C) Distance from right edge of range to supply area| 1 1/2| 38
C) Width of supply areas
•30″ models
•36″ models
•48″ models| N 1.0 NO| 5112776
C) Depth of supply areas (ie maximum protrusion of gas connection from wall)|
2| 51
® Height of gas supply area (from floor)| 12| 305
1 ® Height of electrical supply area (from floor)| 19| 483
ELECTRICAL CONNECTION
All models
IMPORTANT!
- This range must be connected to the mains power supply only by a suitably qualified person.
- This range must be earthed.
- Always disconnect electric supply cord from the wall outlet or service disconnect before servicing this appliance.
- Observe all governing codes and ordinances when grounding, in absence of which, observe National Electrical Code ANSI / NFPA No. 70.
RDV3 models
-
A neutral supply wire must be provided from the power source (breaker panel) because critical range components, including the surface burner spark reignition module, require 120/240 VAC to operate safely and properly.
-
If the correct power supply circuit is not provided, it is the responsibility and obligation of the installer and user to have proper power supply connected.
This must be accomplished in accordance with all applicable local codes and ordinances by a qualified electrician. It is the responsibility of the installer to ensure compliance of local codes. In the absence of local codes and ordinances, the power supply connection shall be in accordance with the National Electric Code. -
Observe all governing codes and ordinances when grounding. In the absence of these codes or ordinances observe National Electrical Code ANSI/NFPA No. 70 current issue. See the following information in this section for grounding method..
-
The ranges are to be connected to a 240/208 VAC power supply.
IMPORTANT!
- An improper 120/240 VAC power supply will cause malfunction, damage to this appliance, and possibly create a condition of shock hazard.
- Improper connection of aluminum house wiring can result in a fire or shock hazard. Use only connectors designed and certified for connecting to aluminum wire.
MODEL | MAX. CURRENT DRAW | CIRCUIT | FREQUENCY |
---|---|---|---|
RDV3-304 | 27 A | 30 A | 60 Hz |
RIV3-304 | 57 A | 50 A | 60 Hz |
RDV3-366 | 29 A | 30 A | 60 Hz |
RIV3-365 | 72 A | 50 A | 60 Hz |
RDV3-488 | 44 A | 50 A | 60 Hz |
RDV3-485GD | 44 A | 50 A | 60 Hz |
RHV3-484 | 75 A | 50 A | 60 Hz |
IMPORTANT!
The fourth prong (round grounding pin) should not, under any circumstances, be
cut or removed.
RDV3 models
Dual Fuel models must be connected to the power supply utilizing one of the
following methods. For all methods of connection, the length of the cord or
conduit/wiring must allow the unit to be slid completely out of the cabinet
without having to unplug or disconnect the unit from the power supply.
Recommended minimum free length of cord or conduit is 4ft (1.2m). Electrical
installations and grounding must be in accordance with all local codes and
ordinances, and/or the National Electric Code, as applicable.
Permanent connection (hard wiring)
Units may be hard wired to the power supply.
The installer must provide approved flexible steel conduit, maximum 6ft (1.8m)
long. Locate the terminal block on the rear of the unit and remove access
cover.
The strain relief bracket orientation must be switched in order to accommodate
for a permanent wiring connection.
This is done by the following:
- Remove the 4 screws on the bracket.
- Re-secure bracket with the four screws so that the 1 1/8″ (29mm) smaller opening is orientated over the opening of the back panel.
- The conduit must be installed to the terminal block using an approved conduit connector. The free end of the conduit must be connected to a junction box provided in the electrical supply zone.
- Mount a strain relief (not provided) into the 1 1/8″ (29mm) diameter hole located below the terminal block. Wiring for the unit is to be brought into the terminal block through the conduit and through the strain relief. The ends of the wiring must have 1/4″ fasten closed loop lugs attached. Make suitable connections to the terminal block provided.
- See 4-wire and 3-wire connection on the right.
- Installer – show the owner the location of the circuit breaker. Mark it for easy reference.
4-Conductor cord
Normally, a unit must be connected to the power supply with a 3-pole,
4-conductor cord kit rated 125/250 volts, 50 amperes, and marked for use with
ranges.
The cord kit must be attached to the range terminal block with a strain relief
which will fit a 1 – 3/8″ (35mm) diameter hole. If not already equipped, the
cord must also have 1/4″ (6mm) fasten closed-loop lugs attached to the free
ends of the individual conductors, preferably soldered in place.
- Remove upper nuts only from terminal block studs. Do not remove lower nuts which secure range wiring leads. Remove and retain the 2 ferrites.
- Mount strain relief (not provided with range) into the 1-1/2” (38mm) diameter hole in the bracket located below the terminal block. Route the wires up through strain relief.
- Route L1 (Black), L2 (Red) and Neutral (White) wires through ferrites. Ground (Green) wire is not routed through ferrites. Ensure ferrites are not touching any electrically live parts.
- Wire connection
1 Secure the Neutral (white) power lead, to the center stud (silver colored) of the terminal block with nut.
2 Secure the L1 (black) and L2 (red) power leads to the outside terminal studs (brass colored) with nuts.
3 Secure the Ground (green) power lead to the back of the range with the screw located beneath the terminal block.
4 Tighten all connections securely.
5 Reinstall the Terminal Block Cover.
3-Conductor cord
Where local codes and ordinances permit grounding through neutral, and
conversion of supply to 4 wire is impractical, unit may be connected to the
power supply with a 3-pole, 3-conductor cord kit rated 125/250 volts, 50
amperes, and marked for use with ranges. The cord kit must be attached to the
range back panel with a strain relief which will fit a 1 – 1/2″ (38mm)
diameter hole. If not already equipped, the cord must also have 1/4″ (6mm)
fasten closed-loop lugs attached to the free ends of the individual
conductors.
1 Remove upper nuts only from terminal block studs.
Do not remove lower nuts which secure range wiring leads. Remove and retain
the 2 ferrites.
2 Mount strain relief (not provided with range) into the 1-1/2” (38mm)
diameter hole in the bracket located below the terminal block. Route the wires
up through strain relief.
3 Route L1 (Black), L2 (Red) and Neutral (White) wires through ferrites.
3-Wire Lead connection
- Secure the L1 (black) and L2 (red) power leads to the outside corresponding terminal block studs (brass colored).
- Secure Neutral (white), grounded wire of the supply circuit and reconnect one end of the mounted loop Ground wire, located beneath the terminal block, up through the ferrites to the centre stud (silver colored) of the terminal block with nut.
- Leave the other end of the Ground wire screwed into the back of the range.
- Tighten nuts securely.
- Reinstall the Terminal Block Cover.
GAS CONNECTION
Gas requirements
Verify the type of gas supplied to the location.
The range is shipped from the factory set up and adjusted for Natural Gas or
LP, depending on the specific model ordered.
Verify that the range is compatible with gas supply at the installation site
before proceeding further.
Return the range to the dealer if the unit is not set for the gas supplied at
the site.
Natural gas
Connection: 1/2″ NPT Minimum 5/8” dia. flex line.
Supply Pressure: 6” to 9″ WC.
LP gas
- Connection: 1/2″ NPT Minimum 5/8″ dia. flex line.
Supply Pressure: 11″ to 14″ W.C. - Regulator is required at the LP source to provide a maximum pressure of 14” W.C. to the range regulator.
Requirements for hook-up to gas supply
- The gas supply connections should be made by a qualified technician in accordance with local codes or ordinances. In the absence of a local cade, the installation must conform to the latest edition of National Fuel Gas Code ANSI Z.223.1 (Warning: this appliance must be installed by a licensed plumber or gas fitter when within the Commonwealth of Massachusetts).
- A manual shut-off valve (supplied by the installer) must be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance. (In Massachusetts such shut-off valves should be approved by the Board of State Examiners of Plumbers & Gas Fitters.) The shut-off valve must be located within 6 feet (1.8 meters) of the appliance it serves.
IMPORTANT!
Fisher & Paykel recommends installing the manual shutoff valve In a location readily accessible by the customer, so that gas to the appliance can be shut off in an emergency situation. However, the appliance must not be modified in any way to accommodate such placement.
- The gas supply line must not protrude beyond the back of the appliance.
- Make sure the gas supply is turned off at the wall valve before connecting the appliance
- Leak-testing of the appliance shall be conducted according to the manufacturer’s instructions. See instructions following.
- The appliance must be isolated from the building’s gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa.). The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at the test pressures in excess of 1/2 psig (3.5kPa.). When checking the manifold gas pressure, the inlet pressure to the regulator should be at least 7.0″ W.-C. for natural gas or 12.0″ for LP.
- The flex line for the gas supply must be metal and be approved for appliance use by a certifying agency (CSA, CGA, or UL). Never use a hose made of rubber or other synthetic material, as the heat may cause the hose to melt and develop leaks.
- When hooking up the gas supply from the wall hard pipe to the range hard pipe, installation length of flex line between range/wall hard piping must accommodate range being pulled from wall for cleaning or servicing purposes. When range is pulled from wall, no strain should occur at range or wall hard pipe connections.
TOE KICK INSTALLATION
Insert both foot covers into the toe kick ensuring the long hem edge is facing the inside of the product.
Align the toe kick with side panels of the range.
Clip into place by rotating and pushing the bracket down over the range
structure.
Check toe kick is flush with the range and secure using 2 screws.
LEVELLING THE RANGE
To expose both front feet, slide the interlocking foot covers out of the way.
Turn feet to adjust the height.
Replace both sets of covers, ensuring each set locks together.
PRIOR TO FINAL POSITIONING
- Ensure the doors and toe kick panel are securely in place, if removed previously.
- Ensure any Backguard is fitted prior to final positioning. Refer to page 10 for the Backguard options.
- Ensure all electrical and gas connections have been done as per instructions.
- Ensure flooring and adjacent cabinetry are also level. To achieve a flush fit of the range to adjoining countertops, it will be necessary to have level cabinets (front to back, and left to right across opening of the range).
COOKTOP BURNERS
- To check that the ignition system operates correctly, light each burner by itself, then all burners in combination.
- Check for a well-defined blue flame without any yellow tipping.
- If any abnormality is evident, check that the components of the burner assembly are located properly.
- When installing the burner port ring, align the two locating pins in the bottom side of the port ring with the locating notch and center holes on the top side of the simmer ring, and make sure these are properly engaged.
- Incorrect installation may produce a potentially dangerous flame and result in poor burner performance.
- No air shutter adjustment is possible on the cooktop burners. Proper operation is achieved with factory installed settings for the correct gas type.
- If proper operation cannot be obtained, contact Customer Care or your nearest Fisher & Paykel Authorized Service Center.
- The range and cooktop must not be used by the customer until proper operation has been achieved.
LEAK TESTING
- Make sure all oven and burner knobs are set to OFF before connecting range to gas supply.
- After final gas connection is made, turn gas supply on and test all connections in gas supply piping for gas leaks with a soapy water solution.
- In order to avoid property damage or serious personal injury, never use a Lighted match or open flame.
If a leak is present, tighten joint or unscrew, apply more joint compound, tighten again and retest connection for leak.
GRILL AND GRIDDLE BURNERS (SOME MODELS ONLY)
- Each valve and air shutter is individually tested and adjusted prior to shipment. Normally adjustment is not required, however, vibration during transit, gas conversion or variations in the local gas supply may make minor adjustments necessary.
- Check for the proper burner flame characteristics and adjust air shutters if necessary.
Burner flames should be blue and stable with no yellow tips, excessive noise or lifting of the flame from the burner.
If any of these conditions exist, check that the air shutter or burner ports are not blocked.
If this condition persists, adjust the air shutter as required.
If the flame is too yellow, indicating insufficient air, open the shutter to increase air inlet.
If the flame is noisy or tends to lift away from the burner, indicating too much air, close the shutter to reduce air.
INSTALLING THE ANTI-TIP BRACKET
WARNING!
****| To reduce the risk of tipping the appliance, it must be secured by
properly installed anti-tip device packed with the appliance.
• A child or adult can tip the range and be killed.
• Install the anti-tip device to the structure by fastening the supplied
bracket to the floor and wall following the instructions for installing the
anti-tip device.
• Engage the anti-tip device.
• Re-engage the anti-tip device if the range is moved.
All ranges must have an anti-tip device correctly installed as per the
following instructions. If you pull the range out from the wall for any
reason, make sure that the device is properly engaged when you push the range
back against the wall. If it is not, there is a risk of the range tipping
over and causing injury if you or a child stand, sit or lean on an open oven
door.
Instructions are provided for wood and concrete floors. Any other type of
construction may require special installation techniques as deemed necessary
to provide adequate fastening of the Anti-tip bracket to the floor and wall.
The use of this bracket does not preclude tipping of the range when not
Wood substrate
- Place the bracket against the back wall, into the right rear corner where the range is to be located. Leave a gap between the wall (or side of range) and the bracket, as shown.
- Drill 1/8″ diameter pilot holes in the center of the two small holes. A nail or awl may be used if a drill is not available.
- Fasten the bracket securely to the floor and wall.
Concrete or cement substrate
- Locate the bracket as shown.
- Using the bracket as a template, drill (x2) 5/16″ diameter pilot holes in the center of the larger holes to a depth of at least 1 3/4″.
- Place the sleeve anchors into the holes and use a hammer to tap them all the way in.
- Tighten the nuts on the sleeve anchors to fasten the bracket securely to the floor.
Once installed
Check for proper installation of the range and Anti-tip bracket by grasping
the back of the range and carefully attempting to tilt it forward.
FINAL CHECKLIST
TO BE COMPLETED BY THE INSTALLER
GENERAL
- Placement of unit.
- Specified clearance maintained to cabinet surfaces.
- Unit level – front to back, side to side.
- All packaging material and tie straps removed.
- Backguard attached if there is less than 6″ (152mm) clearance to combustibles behind unit.
- Radiant tray placed in grill unit (if equipped). The grill grate is in place.
- Door is correctly installed. Check hinge locks both rest inside slots comfortably and neither of the locating notches are visible when oven door is open. When oven door is closed it should run parallel to surrounding cabinetry and sit completely vertical to ensure oven is sealing correctly.
GAS SUPPLY
- Connection: 1/2 NPT with a minimum 5/8″ diameter flex line. Site gas supply is compatible with range model, and sufficient pressure is available (see section ‘Gas connection’).
- The pressure regulator which is connected to the manifold is set for 5.0″ W.C. for natural gas or 10.0″ W.C. for LP.
- Manual gas shut-off valve installed in an accessible location.
- Unit tested and free of gas leaks.
ELECTRICAL
- Receptacle with properly rated over-current protection is provided for service cord connection.
- Adequate ground connection.
- Front kick panel in place and two screws secure.
OPERATION
- All internal packing materials removed. Check below the grate and inside the oven.
- If used on LP gas, verify that pressure regulator, orifice hoods, air shutters, and valve have been set for use with LP gas.
- Grill grate is seated and does not rock (if equipped).
- Knobs turn correctly and freely.
- Each burner lights satisfactorily, both individually and with other burners operating at the same time.
- Flame adjustment made on air shutter of each oven, griddle, or grill burner.
- Griddle is level and does not rock (if equipped).
- Oven door hinges seated and door opens and closes properly.
- Burner pan supports correctly positioned, level, and do not rock.
- Griddle flame correct.
- Grill flame correct.
- Cooktop burner flame correct.
Complete and keep for safe reference:
Model
Serial no.
Purchase date
Purchaser
Dealer address
Installer’s name
Installer’s signature
Installation company
Installation date
FISHERPAYKEL.COM
© Fisher & Paykel Appliances 2019. All rights reserved.
The product specifications in this document apply to the specific products
and models described at the date of issue. Under our policy of continuous
product improvement, these specifications may change at any time. You should
therefore check with your Dealer to ensure this document correctly describes
the product currently available.
US CA 592032A 08.19
Documents / Resources
|
FISHER PAYKEL RDV3 48 Inch Freestanding Dual Fuel Range with 8
Burners
[pdf] Installation Guide
RDV3 48 Inch Freestanding Dual Fuel Range with 8 Burners, RDV3, 48 Inch
Freestanding Dual Fuel Range with 8 Burners, Dual Fuel Range with 8 Burners,
Range with 8 Burners
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>