Literature Library FG7T Two Stage Fixed Speed High Efficiency Upflow Horizontal and Downflow Gas Furnaces Owner’s Manual

June 15, 2024
Literature Library

Literature Library FG7T Two Stage Fixed Speed High Efficiency Upflow

Horizontal and Downflow Gas Furnaces

INFORMATION

The high efficiency gas furnace may be installed free-standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.

This furnace series is approved and certified by the SCAQM and the SJVAPC Districts in the state of California under each Districts’ Mitigation Fee Plan for shipment into and sales in both districts.
For California installations in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.

FEATURES and BENEFITS

  • iSEER: Energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling.
  • 100% fired and tested: All units and each component are tested on the manufacturing line.
  • Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
  • 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
  • 30 second post purge: Increases life of heat exchanger.
  • Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology.
  • Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • High static blowers: All models equipped with high static blowers.
  • 90-second cooling cycle blower-off delay (TDR): Increases cooling performance when matched with a Nortek Global HVAC coil.
  • Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
  • Variable speed blower kit: Upgradable to full variable speed with kit.
  • LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
  • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
  • Integrated control board: Incorporates connections for electronic air cleaner, humidifier and twinning.
  • Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws.
  • Blower Compartment: Insulated for ultra quiet operation.
  • 2 Stage Inducer: Optimizes efficiency on first stage heat and reduces sound levels.
  • Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

GAS FURNACE COMPONENTS

Literature-Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-
Horizontal-and-Downflow-Gas-Furnaces- \(1\) Literature-
Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-Horizontal-and-
Downflow-Gas-Furnaces- \(2\)

DIMENSIONS

Literature-Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-
Horizontal-and-Downflow-Gas-Furnaces- \(3\) Literature-
Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-Horizontal-and-
Downflow-Gas-Furnaces- \(4\)

BLOWER PERFORMANCE – FG7TA/TK

Literature-Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-
Horizontal-and-Downflow-Gas-Furnaces- \(5\) Literature-
Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-Horizontal-and-
Downflow-Gas-Furnaces- \(6\)

Notes:

  1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
  2. Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Temperature rises that are shaded in grey are not recommended.

Literature-Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-
Horizontal-and-Downflow-Gas-Furnaces- \(7\) Literature-
Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-Horizontal-and-
Downflow-Gas-Furnaces- \(8\)

Notes:

  1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
  2. Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Temperature rises that are shaded in grey are not recommended.

Literature-Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-
Horizontal-and-Downflow-Gas-Furnaces- \(9\) Literature-
Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-Horizontal-and-
Downflow-Gas-Furnaces- \(10\)

Notes:

  1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
  2. Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Temperature rises that are shaded in grey are not recommended.

MODEL IDENTIFICATION CODELiterature-Library-FG7T-Two-Stage-Fixed-Speed-
High-Efficiency-Upflow-Horizontal-and-Downflow-Gas-Furnaces-
\(11\)

SPECIFICATIONS

FG7TA/TK

MODEL NUMBERS

| ****

060C- 23A1

| ****

080C- 24B1

| ****

100C- 24B1

| ****

100C- 35C1

| ****

120C- 35C1

| ****

140C- 45D1

---|---|---|---|---|---|---
Input – Btuh (a)| 60,000 / 39,000| 80,000 / 52,000| 100,000 / 65,000| 100,000 / 65,000| 120,000 / 78,000| 140,000 / 91,000
Heating Capacity – Btuh| 48,000 / 31,200| 64,000 / 41,600| 80,000 / 52,000| 80,000 / 52,000| 96,000 / 62,400| 112,000 / 72,800
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0
Motor H.P. – Speed – Type| 1/2 – BLDC| 1/2 – BLDC| 3/4 – BLDC| 3/4 – BLDC| 3/4 – BLDC| 1 – BLDC
Motor FLA| 6.2| 6.2| 8.7| 8.7| 8.7| 11.7
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 25-55| 30-60| 30-60| 35-65| 35-65| 40-70
Shipping Weights| 115lbs| 110lbs| 120lbs| 125lbs| 135lbs| 155lbs
FG7TA SKU| 904956F| 904957F| 904958F| 904959F| 904960F| 904961F
FG7TK SKU| 904932F| 904963F| N/A| 904964F| 904965F| 904966F

  • All models are 115 V, 60 HZ. Gas connections are 1/2″ N.P.T. AFUE= Annual Fuel Utilization Efficiency

ACCESSORIES

FG7TA/TK KITS

Description| SKU
Fixed Speed to Variable Speed| 904880
“A” Cabinet Downflow Sub Base Kit| 902974
“B”, “C”, “D” Cabinet Downflow Sub Base Kit| 904911
U.S. LP Conversion Kit (0 to 10,000 ft.) and High Altitude LP| 905028
Canada LP Conversion Kit (0 to 4,500 ft.) and High Altitude LP| 905029
Side Return Filter Kit| 541036
Furnace Twinning Kit| 1010035

Literature-Library-FG7T-Two-Stage-Fixed-Speed-High-Efficiency-Upflow-
Horizontal-and-Downflow-Gas-Furnaces- \(12\)

GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty. For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (03/2019)