ASSEMBLY INSTRUCTION
Read before use
This document contains important technical and safety information about the
device, its safety use and installation.
CAUTION! Before beginning the installation, please read carefully and entirely this guide and any other documents accompanying the device. Failure to follow the installation procedures could lead to malfunction, danger to your health and life, violation of law or refusal of legal and/or commercial guarantee (if any). Allterco Robotics EOOD is not responsible for any loss or damage in case of incorrect installation or improper operation of this device due to failure of following the user and safety instructions in this guide.
Product Introduction
Shelly® is a line of innovative microprocessor-managed devices, which allow remote control of electric circuits through a mobile phone, tablet, PC, or home automation system. Shelly® devices can work standalone in a local Wi-Fi network or they can also be operated through cloud home automation services. Shelly Cloud is a service that can be accessed using either Android or iOS mobile application, or with any internet browser at https://home.shelly. cloud/. Shelly® devices can be accessed, controlled and monitored remotely from any place where the user has internet connectivity, as long as the devices are connected to a Wi-Fi router and the Internet. Shelly® devices have Embedded Web Interface accessible at http://192.168.33. 1 when connected directly to the device access point, or at the device IP address on the local Wi-Fi network. The embedded Web Interface can be used to monitor and control the device, as well as adjust its settings.
https://shelly-api-docs.shelly.cloud/#shelly-family-overview.
Shelly® devices are delivered with factory-installed firmware. If firmware
updates are necessary to keep the devices in conformity, including security
updates, Allterco Robotics EOOD will provide the updates free of charge
through the device Embedded Web Inter- face or the Shelly mobile application,
where the information about the current firmware version is available. The
choice to install or not the device firmware updates is the user’s sole
responsibility. Allterco Robotics EOOD shall not be liable for any lack of
conformi- ty of the device caused by failure of the user to install the
provided updates in a timely manner.
Shelly® Pro Series
Shelly® Pro series is a line of devices suitable for homes, offices, retail
stores, manufacturing facilities, and other buildings. Shelly® Pro devices are
DIN mountable inside the breaker box, and highly suitable for new building
construction. All Shelly® Pro devices can be controlled and monitored through
Wi-Fi and LAN connections. Bluetooth connection can be used for the inclusion
process. Shelly Pro 3EM-400 (The Device) is a DIN rail mountable threephase
energy meter. The Device reports accumulated energy as well as voltage,
current, power factor data in real time. It stores data in non-volatile memory
for later retrieval at least 60 days of 1 min data resolution.
Schematic
Legend
Device terminals:
- A: Phase A input
- B : Phase B input
- C : Phase C and Device power supply input
- N: Neutral input
- IA: Phase A current transformer (CTA) input
- IB: Phase B current transformer (CTB) input
- IC: Phase C current transformer (CTC) input
- IN : Neutral current transformer (CTN) input
Cables:
- LA : Phase A (110-240 VAC)
- LB : Phase B (110-240 VAC)
- LC : Phase C (110-240 VAC)
- N : Neutral cable
Installation Instructions
CAUTION! Danger of electrocution. Mounting/installation of the
Device to the power grid has to be performed with caution, by a qualified
electrician.
CAUTION! Danger of electrocution. Every change in the connections has to
be done after ensuring there is no voltage present at the Device terminals.
CAUTION! Use the Device only with a power grid and appliances which
comply with all applicable regulations. A short circuit in the power grid or
any appliance connected to the Device may damage it.
CAUTION! Do not connect the Device to appliances exceeding the given max
load!
CAUTION! Connect the Device only in the way shown in these instructions.
Any other method could cause damage and/or injury.
CAUTION! Do not install the Device where it can get wet.
CAUTION! Plug in or unplug the LAN cable only when the Device is powered
off!
The LAN cable must not be metallic in the parts touched by the user to plug it
in or unplug it.
RECOMMENDATION : Connect the Device using solid single-core cables with
increased insulation heat resistance not less than PVC T105°C (221°F). Before
starting the mounting/installation of the Device, check that the breakers are
turned off and there is no voltage on their terminals. This can be done with a
phase tester or multimeter. When you are sure that there is no voltage, you
can proceed to connecting the cables.
Following the diagram on fig. 1 install the current transformer CTA around the
Phase A cable to the load(s), CTB around the Phase B cable to the load(s) and
CTC around the Phase C cable to the load(s). Install the CTN around the
Neutral cable from your load(s).
Mount the Device onto the DIN rail. Plug the cables of the CTA, CTB and CTC
into the Device IA, IB and IC input connectors respectively. Plug the CTN
cable into IN. Mount circuit breakers in accordance with your local
regulations and connect the Phase A, Phase B and Phase C cables through them
to the Device A, B and C inputs respectively. Connect the Neutral cable to the
N input.
The Device is powered through its C input. Make sure you have made all the
connections correctly and then turn on the circuit breakers.
Initial Inclusion
If you choose to use the Device with the Shelly Cloud mobile application and
Shelly Cloud service, instructions on how to connect the Device to the Cloud
and control it through the Shelly App can be found in the “App Guide”. The
Shelly mobile application and Shelly Cloud service are not not conditions for
the Device to function properly. This Device can be used standalone or with
various other home automation platforms and protocols.
CAUTION! Do not allow children to play with the buttons/switches
connected to the Device. Keep the devices for remote control of Shelly (mobile
phones, tablets, PCs) away from children.
LED indication
-
Power: Red light if power supply is connected.
-
Wi-Fi (varies):
-
Blue light if in AP mode
-
Red light if in STA mode, and not connected to a Wi-Fi network
-
Yellow light if in STA mode, and connected to a Wi-Fi network.
Not connected to Shelly Cloud or Shelly Cloud disabled -
Green light if in STA mode, and connected to a Wi-Fi network and the Shelly Cloud
-
The LED will be flashing Red/Blue if OTA update is in progress
-
-
LAN: Green light if LAN is connected.
-
Count: Red light will be flashing when the Device is measuring energy according to settings with frequency dependent to the energy flowing through the measured circuit.
User button
- Press and hold for 5 sec to activate Device AP
- Press and hold for 10 sec to factory reset
Specification
- Dimensions (HxWxD): 94x19x69 mm / 3.70×0.75×2.71 in
- Mounting: DIN rail
- Ambient temperature: from -20 °C to 40 °C / from -5 °F to 105 °F
- Humidity 30 % to 70 % RH
- Max. altitude 2000 m / 6562 ft
- Power supply: 110 – 240 VAC, 50/60Hz
- Electrical consumption: < 3 W
- Internal temperature sensor: Yes
- Voltmeters (RMS for each phase): 100 – 260 V
- Voltmeters accuracy: ±1 %
- Ammeters (RMS via CT for each phase and the Neutral): 0 – 400 A
- Ammeters accuracy:
- ±1 % (5 – 400 A)
- ±2 % (0 – 5 A)
- Phase sequence error detection: Yes (option)
- Power and energy meters:
- Active and apparent power
- Active and apparent energy
- Power factor
- Fundamental active and fundamental reactive energy
- Measurement data storage: At least 60 days of 1 min data resolution
- Data export:
- CSV for PQ recorded values
- JSON format export through RPC
- Wi-Fi protocol: 802.11 b/g/n
- RF band: 2400 – 2495 MHz
- Max. RF power: < 20 dBm
- Wi-Fi operational range (depending on local conditions):
- up to 50 m / 160 ft outdoors
- up to 30 m / 100 ft indoors
- Bluetooth protocol : BLE 4.1
- Bluetooth operational range (depending on local construction):
- up to 30 m / 100 ft outdoors,
- up to 10 m / 33 ft indoors
- CPU: ESP32
- Flash: 16 MB
- Webhooks (URL actions): 20 with 5 URLs per hook
- Scripting : mJS
- MQTT : Yes
Declaration of conformity
Hereby, Allterco Robotics EOOD declares that the radio equipment type Shelly
Pro 3EM-400 is in compliance with Directive 2014/53/ EU, 2014/35/EU,
2014/30/EU, 2011/65/EU. The full text of the EU declaration of conformity is
available at the following internet address:
https://shelly.link/Pro3EM-400_DoC
Manufacturer : Allterco Robotics EOOD
Address: 103 Cherni vrah Blvd., 1407 Sofia, Bulgaria
Tel. : +359 2 988 7435
E-mail: support@shelly.cloud
Official website:
https://www.shelly.cloud
Changes in the contact information data are published by the Manufacturer on
the official website. https://www.shelly.cloud
All rights to the trademark Shelly® and other intellectual rights associated
with this Device belong to Allterco Robotics EOOD.
References
- Shelly Home
- Welcome to Shelly Technical Documentation | Shelly Technical Documentation
- Shelly Pro 3EM-400
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>