resideo EW150 Electronic Water Meter Instruction Manual

June 15, 2024
resideo

resideo EW150 Electronic Water Meter

resideo EW150 Electronic Water Meter

READ THROUGH CAREFULLY BEFORE USE. KEEP ACCESSIBLE THROUGHOUT THE PRODUCT LIFETIME.

Security and guarantee

The device is maintenance-free. This product may only be installed by trained specialist personnel in accordance with with this installation manual.
Suitable measures must be taken to ensure that drinking water hygiene requirements are met during transport, storage and use. Observe country- specific standards and guidelines!

Intended use

Water meters are used to record the consumption of drinking water. Water meters are exclusively intended for this purpose. Any other use of the device is considered to be improper. Changes to the unit must be approved.

Warranty and guarantee

Warranty and guarantee claims can only be asserted if the parts have been used as intended and the technical specifications of the applicable rules have been observed.

Safety Instructions

Improper handling or excessive tightening of screwed connections leads to leaks. Observe the maximum torque specified in the instructions.

Non-permissible assembly materials!
Impact wrenches, hemp, sealing tape, grease or lubricants are not permitted during installation.

Seals

Seals must be suitable for the intended use in terms of dimensions and thermal load. Only use the seals supplied with the device.

Safety Instructions for Lithium Batteries

For the non-replaceable lithium metal battery permanently installed in the device, regulations for the transport of dangerous goods and recycling as well as safety instructions for handling batteries must be observed. The test certificates for the batteries used are available on request.

Correct disposal of this product

WEEE Directive 2012/19/EU; Waste of Electrical and Electronics Equipment Directive; Disposal Information:
Do not dispose this device and contained batteries with the general household waste. For proper treatment, recovery and recycling, please take the device and contained batteries to designated collection points. Disposing of this device and of contained batteries correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling.

Radio activation

The radio transmitter of the device is automatically activated after a flow of 50 litres, but without sending installation telegrams. Alternatively, the radio is activated with the RML10-STD or the parameterisation software

Walk-by (mobile data recording)

12 minutes after the radio transmitters are activated, the device sends control telegrams. The device then sends regular walk-by telegrams.

AMR (automatic data recording)

After the radio transmitter has been activated, the device transmits installation telegrams for integration in the AMR network. Then the device transmits regular data telegrams and statistics telegrams depending on the radio mode set.

Parameter setting

The parameter setting of the device is done using the parameter setting software.

Display loop

  1. Error code
  2. Error date
  3. Cum. volume
  4. Segment test: Display on/off
  5. Last due date
  6. Consumption until last due date
  7. Radio mode
  8. Displayed only in the event of an error
  9. Can be shown and hidden via parameterisation software
    Display loop

Environmental conditions

Protection class:| III according to EN 61140
Transport:| -25 °C … 70 °C, Relative air humidity: max. 95 %, without condensation
Storage:| -5 °C … 45 °C, Relative air humidity: max. 95 %, without condensation
Operation:| 5 °C … 55 °C, Relative air humidity: max. 95 %, without condensation
Influencing quantities

Electromagnetic class:| E1
Mechanical class:| M1
Protection rating

IP protection rating:| IP65, IP68
Temperature range

Hot water meter:| 30 °C … 90 °C
Cold water meter:| 0,1 °C … 30 °C
Flow sensor

Max. permissible operating pressure| 1,6 MPa (16 bar)
Pressure loss:| ≤ 0,63 bar (0,063 MPa)
Inflow and outflow zone:| not necessary (U0/D0)
Radio

Radio modes:| S-Mode (AMR, walk-by) C-Mode (AMR, walk-by)
Radio frequency:| S-Mode (868,3 +/- 0,3) MHz
C-Mode (868,95 +/- 0,25) MHz
Transmission power:| typically 10 dBm, maximum 14 dBm
Encryption: (optional)| Security Mode 5 according to EN 13757-7, Security Profile A according to OMS specification
Power supply

Nominal voltage:| DC 3 V
Battery life:| 1 year storage, 10 years radio operation, 1 year reserve
Battery

Lithium content per battery:| 0,58 g
Battery type:| CR AA
Batteries per unit:| 1x

Installation positions

  1. Installation horizontal
  2. Installation vertical
  3. Installation horizontal, rotated 90 degrees
  4. No overhead installation!
    Installation positions

Install the meter in the direction of flow!
Observe the marking on the meter!

Before starting assembly

  1. Thoroughly flush the pipeline, shut off the measuring point and relieve the pressure!
  2. Dismantle flush pipe / seals / old meter
    Before starting assembly

Danger of scalding!
Hot water or steam.
Let the pipeline cool down!

Mounting steps – Installation

  1. Check the sealing surfaces for damage and clean if necessary.
  2. Install the new meter with new seals.
  3. Tighten the threaded joints!
    Mounting steps - Installation

Pay attention to torque!
25…30 Nm

Installation steps – Check and seal installation

  1. Slowly open the shut-off valves.
  2. Check the installation spot for leaks.
  3. Seal the device!
    Installation steps - Check and seal installation

EU Declaration of conformity

Device Type: WME5 N 1 ** | WME5 T *1 ***

We, QUNDIS GmbH, Sonnentor 2, DE-99098 Erfurt, declare under our sole responsibility that this product(s) of the product line:

Water meter: Q water 5.5

to which this declaration relates is/are in conformity with the requirements of the following directive(s):

2014/32/EU: Measuring Instrument Directive (MID) OJ L96/149, 29.03.2014
2014/53/EU: Radio Equipment Directive (RED) OJ L153/62, 22.05.2014
2011/65/EU: Restriction of the use of certain hazardous substances (RoHS), OJ L174/88, 01.07.2011

The conformity was checked in accordance with the following harmonised EN standard(s):

EN 62479:2010
EN 300 220-2 V3.1.1
EN 301 489-1 V1.9.2
EN 62368-1:2014 + AC:2015
EN IEC 63000:2018

The notified body, Body No

Physically  Technical Federal agency, Braunschweig and Berlin, 0102 issued the certificate:

MID MODUL B : DE-18-MI001-PTB002 (single jet)
MID MODUL B : DE-18-MI001-PTB003 (multi jet)
MID MODUL D: DE-M-AQ-PTB008

Further applied standards/specifications:

EN ISO 4064-1:2017
EN ISO 4064-2:2017
EN 301 489-1 V2.1.1
EN 301 489-3 V1.6.1

Signature

For support contact:
Ademco 1 GmbH, Hardhofweg 40,
74821 MOSBACH, GERMANY
Phone: +49 6261 810
Subject to change
EN0H-0461GE23 R0923
© 2023 Resideo Technologies, Inc.
All rights reserved.

For more information resideo.com

This document contains proprietary information and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization is strictly forbidden.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

resideo User Manuals

Related Manuals