VASSILIAS R-91216 Dehumidifier Health Clean Instruction Manual

June 15, 2024
VASSILIAS

VASSILIAS R-91216 Dehumidifier Health Clean

Product Information

Specifications

  • Model: R-91216
  • Type: Dehumidifier
  • Operation Area: Not for commercial or industrial applications
  • Working Effect: Ensure air inlet/outlet is clean and not blocked, avoid direct sunlight
  • Minimum Clearance:
    • Up: 30 cm or more
    • Left: 20 cm or more
    • Right: 20 cm or more

Product Usage Instructions

Safety Precautions

  • This appliance can be used by children aged 8 years and above, as well as individuals with reduced physical, sensory, or mental capabilities if they are supervised or instructed on safe usage.
  • Before operation, check if the power cord complies with the requirements indicated on the nameplate.
  • Always turn off and unplug the dehumidifier before cleaning.
  • Avoid pressing the power cord with any hard object.
  • Do not remove the power plug or move the unit by pulling the power cord.
  • Avoid using any heating applications near the dehumidifier.
  • Do not remove the power plug with wet hands.
  • Use a grounded power cord and ensure it is well connected and undamaged.
  • Children and disabled people should not use the dehumidifier without supervision.
  • Keep children from playing or climbing on the dehumidifier.
  • Do not place the dehumidifier under dripping objects.
  • When the unit is not attended, turn it off, remove the power plug, or disconnect power.
  • Do not attempt to repair or disassemble the unit yourself.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid hazards.
  • Cleaning and user maintenance should not be done by children without supervision.
  • If an abnormal condition occurs (e.g., burned smell), disconnect power immediately and contact the local dealer.
  • Proper disposal of the dehumidifier should be done in accordance with local regulations and guidelines.

Warning

Do not use any means to accelerate the defrosting process or clean the dehumidifier other than those recommended by the manufacturer. Store the appliance in a room without continuously operating ignition sources (e.g., open flames, operating gas appliances, or operating electric heaters). Do not pierce or burn the appliance. Be aware that refrigerants may not have an odor. The maximum refrigerant charge amount is 55 g. If the machine malfunctions, do not attempt to repair it yourself. Contact a professional organization or a service organization recommended by the supplier for repair.

Parts Name

  • HUMIDITY INDICATOR LIGHT
  • CONTROL PANEL
  • HANDLE
  • ROLLERS
  • CONTINUOUS DRAIN WATER TANK

Check Before Operation

Before operating the dehumidifier, perform the following checks:

  1. Hold the handles on both sides of the water bucket and pull it out following the arrow direction.
  2. Check if the dehumidifier is properly placed. If it has been moved during transportation, adjust it to the correct position by hand.
  3. Remove the handle and inspect it for any damage.

FAQ

Q: Can children use this dehumidifier?
A: This appliance can be used by children aged 8 years and above, but they should be supervised or instructed on safe usage.

Q: Can I repair the dehumidifier myself?
A: No, do not attempt to repair the unit yourself. Contact a professional organization or a service organization recommended by the supplier for repair.

Q: How should I dispose of the dehumidifier?
A: Proper disposal should be done in accordance with local handling disposal or information service center guidelines.

Instruction Manual

Thank you for choosing our product.
For proper operation, please read and keep this manual carefully.

Operation Area

  • This dehumidifier is intended for indoor residential applications only. It should not be used for commercial or industrial applications.
  • Place the dehumidifier on a smooth and level floor.
  • A dehumidifier operating indoors will have no effect in drying an adjacent enclosed area, such as a closet.
  • Place the dehumidifier in an area where the temperature will not below 5°C or above 32°C.
  • Allow at least 20-30 cm of air space on all sides of the unit.
  • Close all doors, windows and other outside openings of the room to improve the working effect.
  • Please keep the air inlet/outlet clean and not blocked.
  • Do not use a dehumidifier in a bathroom.
  • Avoid direct sunlight.

VASSILIAS-R-91216-Dehumidifier-Health-Clean-1

Notes:
The dehumidifier has rollers to aid placement. Do not attempt to roll the dehumi- difier on carpet or over objects. Otherwise, water may spill out from the bucket or the dehumidifier may get stuck by the objects.

Safety Precautions

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Before operation, please check the power cord if it complies with the requirement indicated on the nameplate.
  • Before cleaning, please turn it off and unplug the dehumidifier.
  • Make sure the power cord is not pressed by any hard object.
  • Do not remove the power plug or move unit by pulling the power cord.
  • Do not use any heating application near the dehumidifier.
  • Do not remove the power plug in wet hands.
  • Please use grounded power cord and make sure it’s well connected and not damaged.
  • Children and disabled people are not allowed to use the dehumidifier without supervision.
  • Children shall not play with the appliance.
  • Keep children from playing or climbing on the dehumidifier.
  • Do not place the dehumidifier under dripping objects.
  • Memory function is included in this dehumidifier. When nobody is taking care of the unit, please turn it off and remove the power plug or disconnect power.
  • Do not repair or disassemble the unit by yourself.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • If abnormal condition occurs (e.g. burned smell), please disconnect power at once and then contact local dealer.
  • Dehumidifier can not be disposed of everywhere. If you want to get rid of this dehumidifier, please check with local handling disposal or information service center about what to do.

WARNING

Caution, risk of Fire
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater. Do not pierce or burn. Be aware that refrigerants may not contain an odour. The maximum refrigerant charge amount: 55 g. When the machine malfunctions, do not repair it yourself. Please contact a professional organization or a professional trained maintenance personnel or a service organization recommended by the supplier for repair!

Parts Name

Front Side

VASSILIAS-R-91216-Dehumidifier-Health-Clean-2

Back Side

Check Before Operation

Before operation, please first check whether float is properly placed.

Below are the checking steps:

  1. Hold the handles on both sides of the water bucket and pull it out following the arrow direction.
  2. Check whether float in the water bucket is properly placed. It might have been moved a little after long-time transportation. If it’s not placed properly, move it to the correct position by hand. Please remove the handle and check it.

Operation Method

VASSILIAS-R-91216-Dehumidifier-Health-Clean-5

Indicator Lights

VASSILIAS-R-91216-Dehumidifier-Health-Clean-6

Notes:

  • Water bucket must be correctly installed for the dehumidifier to operate.
  • Do not remove the bucket while unit is in operation.
  • If you want to use drain hose to drain water away, please install the hose according to section “Drainage method”.
  • Each time pressing the effective button on the control panel will give out a “beep” sound.

Basic Functions of the Buttons

Power Button or Stand by
Press this button to turn on/off dehumidifier.

Humidity Settings
Set humidity, set the range of 30%-80%
In normal mode, press left or right arrows to set humidity level

Air Cleaner
If vou choose the compressor ston to work and the unit work as air purifier only

Auto Swing button
Press Auto Swing button and the corresponding indicator will light up. The louver will start to swing automatically.

Clild Lock
Long press Auto Swing button and Air clean button
Again long press 5 second to unlock

Fan Speed Button
Pressing this button can set fan speed circularly as: High, Low.
Corresponding indicator will be on for each fan speed.

Timer Button
Press this button to set Timer On or Timer Off (Timing range 01~24h).

  • Set Timer Off:
    When unit is on, press this button and the Timer Indicator will be blink.
    Timer will increase each time you press the button by 01 to 24 h.
    When time is set, wait for 5s or press this button to turn this function on.

  • Cancel Timer Off:
    Under the condition that this function is turned on, press the button TIMER until the timer screen 00 h

  • Set Timer On:
    When unit is off, press this button and the Timer Indicator will be blink.
    Timer will increase each time you press the button by 01 to 24 h.
    When time is set, wait for 5s or press this button to turn this function on.

  • Cancel Timer On:
    Under the condition that this function is turned on, press the button TIMER until the timer screen 00 h

  • Timing range: 01~24 hours.

Dehumidify Mode Button

Press this button to select different kinds of working mode. After each pres- sing of this button, mode will switch among the below options

  • Normal
  • Automatic
  • Strong
  • Normal

You can set the target humidity 30% – 80 % and se the speed fan as you wish.

  • Automatic
    In this option the unit work without any set of humidity but the fan speed is in LOW speed automatically. In this option you cannot set the humidity the unit works continuously.

  • Strong

The default target humidity level is 30%. The appliance constantly works with the dehumidifying function until ambient humidity reaches 30%. The fan will operate at high speed and cannot be adjusted.

Dry Cloths button
In this option the unit work appropriate in order to dry your cloths the fan speed set in HIGH speed automatically. In this option you cannot set the humidity the unit works.

Other Instructions

  1. Alarm Warning
    If bucket is full or not locked into place, buzzer will go off for 20s to remind you to empty bucket or put it back into the correct place.

  2. Auto Stop
    When bucket is full, removed or not placed correctly or the humidity is 5% lower than the set humidity, unit will automatically stop.

  3. Memory Function
    If power is lost, all of the control settings are remembered. So when power is restored, the unit will start back up in the settings it was in when power was lost.

  4. Full of water light
    This indicates that bucket is full or removed or not placed correctly.

Drainage Option

Option 1 Emptying Manually

Notes:

  • Do not remove the bucket when unit is in operation or has just stopped.
  • Do not use the hose if using water bucket to collect water. When the hose is connected, water will be drained out through it instead of into the bucket.
    1. Hold the handles on both sides of the water bucket and pull it out following the arrow direction. (Attention: Pull out the bucket carefully in case the water may spill out from the bucket and onto the floor.)
    2. Empty the bucket by grasping the handle on the top of bucket with one hand and grasping the bottom of bucket with the other hand.
    3. Replace bucket in the dehumidifier according to the arrow direction.

Option 2 Gravity Drain Hose

  1. Hose is provided, so user shall prepare it in advance. [Size: The hose thread should have an outer diameter of 10 mm and length 1 meter ]
  2. Remove bucket from the unit as instructed.
  3. Thread the drain hose onto the nozzle and make sure it’s securely locked.
  4. Replace the bucket. Make sure the drain hose goes through the bucket’s drain hole and is placed downward. Lead the hose to the floor drain and then cover the hole with a lid. Note that drain hose should not be pressed, otherwise water can not be drained out.

Note: When you want to take off the drain hose, prepare a receptacle to collect water from the nozzle.
Set an air clean filter to a dehumidifier

Notes:
The time life of the ionic and carbon filter is based on the environmental air, normally it replaces after 1 year If it is dirty, clean up dust or debris with a brush and out it in the sunshine.

Clean and Maintenance

Warning:

  • Before cleaning, turn off the dehumidifier and disconnect power. Otherwise it may lead to electric shock.
  • Do not wash the dehumidifier with water, or it may lead to electric shock.
  • Do not use volatile liquid (such as thinner or gasoline) to clean dehumidifier.

Otherwise it will damage unit’s appearance.

  • Grille and Case
    To clean the case:
    When there is dust on the case, use soft towel to dust it off; When the case is very dirty(greasy), use mild detergent to clean it.
    To clean the grille: Use a dust catcher or brush.

  • Water Bucket
    Every few weeks, clean the bucket to prevent growth of mold, mildew and bacteria. Use soft brush to clean the bucket and then rinse it.

Warning:

  • Do not operate the dehumidifier without a filter.
    Otherwise the evaporator will catch dust and affect unit’s performance.

  • Do not dry the air filter with fire or electric hair dryer. Otherwise the air filter may be unshaped or caught on fire.

  • Don’t use dust catcher or brush to clean the air filter. Otherwise the air filter may be destroyed

Check Before Use-season

  • Check whether air outlet is blocked.
  • Check whether power plug and power socket are in good condition.
  • Check whether air filter is clean.
  • Check whether drain hose is damaged.

Long-time Storage
If you won’t use the dehumiditier for a long time, we suggest that you follow the steps below in order to maintain the unit in good condition.

  • Make sure the bucket is clear of water and drain hose is removed.
  • Unplug the dehumidifier and pack the power cord.
  • Clean the unit and wrap it well to prevent the gathering of dust.

Troubleshooting

Not all the following problems are malfunctions.

VASSILIAS-R-91216-Dehumidifier-Health-Clean-10

Problem of Water Leakage.

VASSILIAS-R-91216-Dehumidifier-Health-Clean-11

Dehumidifier does not start

VASSILIAS-R-91216-Dehumidifier-Health-Clean-8

Defrost procedure

Please note if the ROOM temperature is less than 24°C, the unit will start defrost function!

  • ≥24°C: no defrost
  • 18-23°C 2hours dehumidify then 5minute defrost, cycle;
  • 12-18°C: 25minute dehumidify then 5minute defrost, cycle;
  • 5-12°C: 8minute dehumidify then 3minute defrost, cycle; 5-12°C
  • <5°C: unit protection, compressor of, fan of. All operation mode cannot be activated except air circulation mode.

Dehumidifier does not dry air as intended

VASSILIAS-R-91216-Dehumidifier-Health-Clean-12

IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002/96/EC.
At the end of its working life, the product must not be disposed of as urban waste.
It must be taken to a special local authority differentiated waste collection centre or to a dealer providing this service.
Disposing of a household appliance separately avoids possible negative consequences for the environment and health, deriving form inappropriate disposal and enables the constituent materials to be recovered to obtain significant savings in energy and resources. As a reminder of the need to dispose of household appliances separately, the product is marked with a crossed-out wheeled dustbin.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals