G2 GoGEN ME 1296 Weather Station User Manual

June 4, 2024
G2

ME 1296
WEATHER STATION
User Manual
G2 GoGEN ME 1296 Weather Station

MAIN FUNCTION

  • 5 function Keys: SNZ/LIGHT, UP, DOWN, SET, ALARM
  • Radio Controlled Clock receive form: DCF77
  • The barometric absolute pressure value display
  • 4-level weather forecast: Sunny, Partly sunny, Cloudy, Rainy
  • Low Battery indicator for outdoor sensor and indoor station
  • Time display: hour, minute
  • Date display: month, day
  • Week display in English
  • The temperature in °C/°F
  • Indoor temperature from 0°C ~ 50°C
  • Outdoor temperature from -40°C ~ 70°C
  • Indoor/Outdoor humidity 20% ~ 99%
  • Indoor/Outdoor temperature trend indicator
  • Moon phase function
  • Single ring alarm
  • SNOOZE function
  • LED backlight
  • Summertime

DESCRIPTION OF CONTROL

**** 1. Icons weather forecast
2. Barometer display
3. Outdoor temperature/humidity external sensor
4. Channel external sensor
5. Outdoor sensor signal strength
6. Sensor low battery indicator
7. Tendency to outdoor temperature
8. Indoor temperature/humidity
9. Display low battery indicator
10. Tendency to indoor temperature
11. Time display
12. Symbol Radio Control DCF77
13. Weekday
14. Alarm Clock icons| 15. Calendar
16. Moon phase
17. SNZ/LIGHT button
18. UP button
19. DOWN button
20. SET button
21. ALARM button
22. External power supply socket
23. Battery Compartment 3xAA (batteries not included)
24. Wireless signal indicator (Flashes when data is being sent to the display unit)
25. Integrated hang hole
26. TX button
27. TX channel selector, select external sensor channel
28. Compartment 2xAA batteries (batteries not included)
---|---

GUIDE TO THE APPLIANCE

G2 GoGEN ME 1296 Weather Station - FIG 1

POWER METEO STATION
Open the battery compartment (23) on the back of the unit and insert three AA batteries according to polarity. Insert the external power in the socket (22), and insert the adaptor to a wall outlet.
POWER SENSOR EXTERNAL
Open the battery compartment (28) on the rear and insert two AA-size batteries according to polarity.
SETTING THE EXTERNAL SENSOR
This weather station is arranged to communicate with three external sensors. One of these comes with the unit, the remaining two are optional.

  • Power the weather station as described in POWER METEO STATION.
  • Insert the batteries in the external sensor, and set the selector (27) to the desired transmission channel (1, 2, or 3).
  • Press the DOWN button (19) more times to select the channel set on the external sensor.
  • Sequentially selects channel 1, channel, 2, and channel 3. In case of nonreceipt of the display, signal it is shown the character -. Press and hold the DOWN (19) button to receive the RF signal.

Notes: Place the weather station away from equipment that generates magnetic fields such as mobile phones, televisions, etc.
TIME SETTING – DCF77
This device is able to receive the time signal DCF77.

  • Power automatically enters DCF77 receiving after receiving RF. Press and hold the UP button (18) of the weather station, and the symbol (12) will flash the radio control.
  • Receive DCF77 automatically time point for: 1:00 am; 2:00 am; 3:00 am; 4:00 am; 5:00 am; 1:00 – 3:00 am forced receiving, 4:00 – 5:00 am selective receiving.

Notes:

  • When the symbol of the blinking control radio is displayed you cannot make any manual adjustments.
  • When the symbol is steady, it means that the signal was properly received.
  • DCF77 defaults to German local time, if in other European countries, need to set up TIME ZONE, according to the local time compare the German time to the corresponding add and subtract. For example: If the users are in the UK then set TIME ZONE to -1H. Set method: Press the „SET (20)“ button for 3s into setting mode, when TIME ZONE settings, press the UP or DOWN button to adjust the desired time zone. Setting order: Time zone→ 12/24HR→ hour→ minute→ year→ month→ day→ barometer unit→ exit, then back to time mode.
  • Place the weather station away from equipment that generates magnetic fields such as mobile phones, televisions, etc… not all areas of Europe may be able to receive the signal of the radio control. In this case, you must set the time manually.
  • When the weather station is receiving a DCF77 signal, the display will be dark. If the unit has got the DCF77 signal successfully or the DCF77 signal is not automatically received after 7 minutes, the display unit will light up again.

MANUAL TIME/ALARM SETTING

  • Press and hold the SET (20) to enter the manual clock setting.
  • Set the time zone of your region through the UP (18) or DOWN (19). You can choose between +12 to -12.

TIME SETTING

  • In time display mode, long press the SET (20) button for 2 seconds to enter time setting mode, Setting project start flicker
  • Setting order: Time zone→ 12/24HR→ hour→ minute→ year→ month→ day→ barometer unit→ exit
  • In the setting process, single press UP(18) button, the setting value plus one, long press UP(18) button for 2 seconds, the setting value forward at 8 step/second; In the setting process, single press DOWN button, the setting value minus one, long press DOWN(19) button for 2 seconds, the setting value decrease at 8 step/second
  • Weekly changes with year, month, and day.
  •  Without pressing any key within 10 seconds, will automatically exit the setting mode, and the set value will be saved.

ALARM SETTING
In standard mode, single press ALARM (21) to switch time display for alarm mode, displays ALM in the week position.

  • In alarm display mode, single press ALARM (21), open or close the alarm, and the bell symbol appears or disappears.
  • In alarm display mode, long press ALARM (21) button enter alarm setting mode, hour start flicker
  • Setting order: Hour→ minute→ exit
  • In the setting process, single press UP (18) button, setting value plus one; long press UP (18) button, the setting value forward at 8 step/second
  • In the setting process, single press DOWN (19) button, the setting value minus one, long press DOWN (19) button, the setting value decrease at 8 step/second
  • Single press ALARM (21) to confirm the setting or 10 seconds without setting will automatically exit and save.

ALARM AND SNOOZE FUNCTION

  • Default alarm time: am7:00
  • When alarm time arrives, start the BIBI sound alarm
  • Specific formats for: BI(0-10S), BIBI (11-20S), BIBIBIBI (21-30S), BIBIBIBI…(After 31S), The continuous alarm time is 2 minutes.
  • The bell symbol will flick when alarm
  • When the beeping alarm, single press SNZ/LIGHT (17) button to pause the alarm and enter the snooze mode; after a delay of 10 minutes will beep again; the bell symbol will flicker in the snooze function.
  • Whether in alarm mode or in snooze mode, pressing any key except SNZ/LIGHT (17) will exit alarm or snooze mode and return to normal time mode
  • In snooze mode, press the SNZ/LIGHT (17) button again, its original function is not affected.

BACKLIGHT FUNCTION

  • Battery mode: single press SNZ/LIGHT (17) button for a backlight for 10 seconds
  • Adaptor mode: plug the adaptor, automatically switch to light level, and press the SNZ/LIGHT (17) button again to switch the backlight brightness: HI→ LO→ OFF→

LOW VOLTAGE INDICATOR

  • Indoor low voltage: when detecting at a high level, there is no low voltage; when detecting at a low level, there is low voltage, and the low-level symbol appears (9).
  • Outdoor low voltage: according to the transmitter signal instruction, there is a low voltage display (6).

WEATHER FORECAST

  • The unit predicts weather conditions for the next 12 – 24 hours based on the change in atmospheric pressure. The weather forecast is based on atmospheric pressure change and is about 70-75% correct.4 kinds of graphics (SUNNY/PARTLY SUNNY/CLOUDY/RAINY):

G2 GoGEN ME 1296 Weather Station - FIG 2

The atmospheric pressure unit is HPa or in. When set time, you can choose a unit. The digital barometer automatically detects the atmospheric pressure changes accordingly to display the symbol to forecast weather (1). This forecast concerns the 12/24 hours. For example:
If the barometer detects high pressure, the display will show the symbol of the sun, but externally it could rain because the provision relates to the 12/24 hours.
NOTES. The weather forecast symbols may not reflect current weather conditions. They relate only to future conditions. Predictions cannot be 100% secure due to various factors.
The manufacturer is not liable for any damages or situations caused by an incorrect forecast.
TREND OF INDOOR TEMPERATURE – INDOOR TEMPERATURE LESS THAN 0°C
Along with the outdoor temperature, it is shown the prediction of the temperature through the icons (10):

  • temperature decreases, the icon is displayed when a change is registered at a lower temperature of -1°C.
  • stationary temperature, the icon is displayed when a change is registered in temperature between +/-1°C.
  • temperature rising, the icon is displayed when you record a higher temperature change of +1°C.

TREND OF OUTDOOR TEMPERATURE – OUTDOOR TEMPERATURE LESS THAN 0°C
Along with the outdoor temperature, it is shown the prediction of the temperature through the icons (7):

  • temperature decreases, the icon is displayed when a change is registered at a lower temperature of -1°C.
  • stationary temperature, the icon is displayed when a change is registered in temperature between +/-1°C.
  • temperature rising, the icon is displayed when you record a higher temperature change of +1°C.

Accuracy:
Temperature accuracy: : -40°C až -20°C: ± 4°C / -20°C až 0°C: ± 2°C / 0°C až +50°C: ±1°C
Humidity accuracy ±5 % od 35 % do 75 % a ±10 % od 20 % do 35 % a od 75 % do 95 %.

IMPORTANT PLACEMENT GUIDELINES

  • To ensure accurate temperature measurement, place units out of direct sunlight and away from any heat sources or vents.
  • The display unit and outdoor sensor must be within 99ft (30m) of each other.
  • To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
  • To prevent wireless interference, place both units at least 0,9 m away from electronic devices (TV, computer, microwave, radio, etc.)

G2 GoGEN ME 1296 Weather Station - FIG 3

TECHNICAL DATA

Weather station: 0°C ~ 50°C
Indoor humidity: from 20% ~ 99% RH (relative humidity)
External sensor: from -40°C ~ + 70°C
Channel: max. 3 external sensors
Receiving radio control signal: 77,5 kHz
Transmission: 30m RF 433.92MHz, Earp 0,04 mW
Main unit power: 3 x AA batteries (not included)
External sensor supply: 2 x AA batteries (not supplied)
WE RESERVE THE RIGHT TO CHANGE TECHNICAL SPECIFICATIONS.
WARNING: DO NOT USE THIS PRODUCT NEAR WATER, OR IN WET AREAS TO AVOID FIRE OR INJURY OF ELECTRIC CURRENT. ALWAYS TURN OFF THE PRODUCT WHEN YOU DON’T USE IT OR BEFORE A REVISION. THERE AREN’T ANY PARTS IN THIS APPLIANCE WHICH ARE REPARABLE BY CONSUMER. ALWAYS APPEAL TO A QUALIFIED AUTHORIZED SERVICE. THE PRODUCT IS UNDER A DANGEROUS TENSION.
TO AVOID THE DANGER OF SUFFOCATION, KEEP THE PLASTIC BAG AWAY FROM BABIES AND CHILDREN. DO NOT USE THIS BAG IN CRIBS, BEDS, CARRIAGES, OR PLAYPENS. THIS BAG IS NOT A TOY.
Disposal of old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems)
This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead, it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling this product, please contact your local Civic Office, your household waste disposal service, or the shop where you purchased the product.
Hereby, ETA a.s. declares that the radio equipment type ME1296 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: http://www.gogen.cz/declaration_of_conformity

Charging adapter

A| Manufacturer’s name or trademark, business registration number and address| HUAXU ELECTRONICS FACTORY, No. 1 Shi Tang Bei Street 2, Shi Jie Town, Dong Guan City, 523290, Guangdong,  China
B| Model identifier| HX075-0500600-AG-001
C| Input voltage| 100 – 240 V
D| Input frequency| 50/60 Hz
E| Output voltage| 5,0 V
F| Output current| 0,6 A
G| Output power| 3,0 W
H| Average efficiency in active mode| 76,04%
I| Low load efficiency (10%)| –
J| Power consumption without load| 0,083 W

www.GoGEN.cz

Documents / Resources

| G2 GoGEN ME 1296 Weather Station [pdf] User Manual
GoGEN ME 1296 Weather Station, GoGEN ME, 1296 Weather Station, Weather Station
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

G2 User Manuals

Related Manuals