planika 590 Prime Fire Bioethanol Fireplace Instruction Manual

June 15, 2024
planika

Prime Fire
590, 790, 990, 1190
Installation manual

planika 590 Prime Fire Bioethanol Fireplace - Cover

590 Prime Fire Bioethanol Fireplace

WARNING
This manual only applies to the installation and operation of Prime Fire 590, 790, 990, 1190 burner only. The installation of the fireplace in Forma firebox, Daze / Laurent Box is included in the other manual.

The product is a decorative device creating real fire.
Read the included documentation prior to installing and operating the device.
Consult the local regulations for fireplaces.

  1. For indoor use and in housing only. Min. temperature of use is 10°C.
  2. Natural air exchange rate in room – min. 1/h.
  3. Do not use the device in humid and drafty spaces.
  4. Do not cover top ventilation openings of the device.
  5. No heat-sensitive and flammable objects can be placed within a 1 meter radius from and directly above the device.
  6. Do not place any objects on the top of the device.
  7. We recommend placing a CO2 or dry powder fire extinguisher nearby the device
  8. For service purposes, the surrounding must allow for easy removal of the device.
  9. Keep children, animals and unauthorized persons away from the device.
  10. Keep the packaging and manuals for future use.
  11. Do not turn on the device in case of fuel spill.
  12. Do not interfere in the fuel filler when the device is operating.
  13. Do not interfere in the device construction.
  14. Do not touch the filament and other hot elements.
  15. Do not transport the device if fueled.
  16. Do not leave an operating device unattended.

Burner| L [mm]| D [mm]| H [mm]| Minimum
Room Size [m3]| Heat
[kW]
---|---|---|---|---|---
Prime Fire| Prime Fire| Prime Fire| Prime Fire| FLA 3 / FLA 3+
590| 590| 280| 220| 31| 3,1
790| 790| 44| 4,4
990| 990| 70| 7,0
1190| 1190| 94| 9,4

planika 590 Prime Fire Bioethanol Fireplace - Product Overview
1

A. Burner Quantity
B. Glass shield 1
C. Small glass holder 1x 590, 790, 990, 1190
D. Glass holderconnector 2x 590, 790, 990 3x 1190
E. Remote control
F. Service cable 1
G. Fuel pump 1
H. Installation and user’s manual 1
I. Windscreen connector type 1 1
J. Windscreen 4x 590, 790, 990,1190
K. Tall glass holder 2x 590, 790, 990,1190,
L. Windscreen connector type 2 4x 590, 790, 990,1190,
M. Washer

NON-FLAMMABLE MATERIAL

planika 590 Prime Fire Bioethanol Fireplace - Product Overview
2

The fireplace surrounding must be made of non-flammable materials and insulated from any flammable elements of the construction. Use only fasteners and adhesives that are resistant to high temperature.

planika 590 Prime Fire Bioethanol Fireplace - Product Overview
3 planika 590 Prime Fire
Bioethanol Fireplace - Product Overview 4

Selected installation options

| GLASS SHIELD (B)| | NON-FLAMMABLE MATERIAL
---|---|---|---

planika 590 Prime Fire Bioethanol Fireplace - Product Overview
5

| GLASS SHIELD (B)| | OPTIONAL TEMPERED GLASS PANEL (I)| | NON-FLAMMABLE MATERIAL
---|---|---|---|---|---

planika 590 Prime Fire Bioethanol Fireplace - Product Overview
7 planika 590 Prime Fire
Bioethanol Fireplace - Product Overview 8 planika 590 Prime Fire Bioethanol Fireplace - Product
Overview 9

planika 590 Prime Fire Bioethanol Fireplace - Product Overview
12

1. Filament
2. Burner
3. Device surface| 4. Control panel
5. Fuel filler
6. Fuel pump (a, b, c)
---|---

planika 590 Prime Fire Bioethanol Fireplace - Product Overview
13

1. ECO mode
2. Flame ignition / flame extinguishing| 3. Service socket
4. Control diodes
---|---
| Diodes OFF
---|---
| Diodes ON
| Blinking diodes

FUEL FILLING

  1. If the tank is empty ( ) or you want to fill the fuel, open the fuel inlet (I), firmly connect the pump hose ‘a’ (click!) and power cable ‘b’ (II) ( ). ATTENTION! Do not  refuel when the flame is ignited!
    planika 590 Prime Fire Bioethanol Fireplace - Product Overview
14Place the fuel container stably on the floor and insert the pump hose ‘c’ (III). Press and hold the button on the pump to start refuelling (IV).
    planika 590 Prime Fire Bioethanol Fireplace - Product Overview
15Once the fuel container has been emptied, replace it with a full one and start the pump again (see point 2).
    The pump will stop when the tank is full (sound + ).

  2. Disconnect the power cable ‘b’. To disconnect the pump, hold the end of the hose ‘a’ and firmly press the button in the place marked with a sticker (V). Close the fuel inlet..

  3. Shake the remaining fuel from the hose ‘c’ to the container and place the pump in the bag (VI).
    planika 590 Prime Fire Bioethanol Fireplace - Product Overview
17

FLAME IGNITION

The green diode indicates that the device is ready to ignite the flame.
Press and hold START for 3 seconds. Flame ignition will take 2-10 minutes ( ). The smell of ethanol vapors can be present during the ignition. The diode READY off ( ) indicates that the flame has been ignited and the device reached the working temperature.

FLAME HEIGHT REGULATION

When the flame is ignited, press ECO to lower the flame (two sound signals). Press ECO again to increase the flame height (one sound signal).
ATTENTION! In case the device temperature is too high, the flame will be automatically lowered (ECO) and the height regulation blocked. If the temperature keeps increasing, the device will be turned off.

FLAME EXTINGUISHING

Press STOP to extinguish the flame (sound signal + ).
You can ignite the flame again when the device is cooled – the green diode READY ( ).

FAST START

The FAST START offers faster flame ignition (when the device is ready ( ), the power consumption is 60 W higher).
The function is enabled by default.
To disable FAST START, press and hold ECO for 10 seconds (four sound signals). To enable the function, press and hold ECO for 10 seconds (two sound signals).

ERRORS

Some alarms are accompanied by a sound signal. Press START/STOP to mute.

Lp.| DIODES| SOLUTION
(contact the Service Department if the solution does not eliminate the error)
---|---|---
1.| | The device is being cooled. Wait for the green diode .
2| | The device run out of fuel while operating. The device is being cooled.
Wait for the red diode to turn off. Refill the tank.
3.| | If spillage occurred while pouring the fuel, disconnect the fuel pump and wipe off the visible liquid. Mute the device ( START/STOP button) and wait for at least one hour.
Press and hold ECO for 10 seconds. If the message does not disappear, turn off the device and wait for a minimum of 24 hours.
If the error occurred during flame ignition, it means that the ignition time has been exceeded. Press and hold ECO for 10 seconds.
4.| | Device error. Press and hold ECO for 10 seconds.
5.| | Tank overfilled. Contact the Service Department.
6.| | Room temperature too low (<10°C) or device error. Increase the room temperature.
Press and hold ECO for 10 seconds. Wait for the green diode READY .
7.| | Press and hold ECO on the control panel for 10 seconds.

FUEL – Use only ethanol fuel produced from plants in the process of two- time alcohol distillation consisting of 95-96.6% ethanol by volume. Fanola is the recommended fuel with pharmacological purity.
DO NOT USE SYNTHETIC PETROLEUM BASED FUELS AS THEY ARE CONTAMINATED, EMIT UNPLEASANT ODORS AND CAN
DAMAGE THE FIREPLACE! DO NOT USE FUELS CONTAINING 100% ETHANOL BY VOLUME, GEL, OR AROMATIC FUELS!
CLEANING – Clean with a damp cloth and delicate detergents, only when the device is turned off and cooled.
SERVICE – Keep the provided USB cable for service. Reach out to us at service@planikafires.com.