planika Scandi Freestanding Ethanol Fireplace Stove Installation Guide

June 10, 2024
planika

planika Scandi Freestanding Ethanol Fireplace Stove

PACKAGE CONTENTS

DIMENSIONS

The product is a decorative device creating real fire.
Read the included documentation prior to installing and operating the device. Consult the local regulations for fireplaces.

  1. For indoor use only. Do not use in temperatures below 10°C.
  2. Do not use the device in the area smaller than 41 m3
  3. Room air exchange rate – min. 1/h.
  4. Do not use the device in humid and drafty conditions.
  5. Do not cover top ventilation openings of the device.
  6. No heat-sensitive and flammable objects can be placed within a 1 meter radius from the device.
  7. There must be a CO2 or dry powder fire extinguisher nearby the device.
  8. Keep children, animals and any unauthorized persons away from the device.
  9. Keep the packaging and manuals for future use.
  10. Do not turn on the device in case of fuel spill.
  11. Do not interfere in the fuel tank when the device is operating.
  12. Do not interfere in the device construction.
  13. Do not touch the filament and other hot elements.
  14. Do not transport the device if fueled.
  15. Do not leave an operating device unattended.
  16. For the first few hours of use, there may be a distinct scent of paint

Selected installation options


Connection to chimney flue forbidden

Glass assembly



N Do not cover top ventilation openings of the device.


Follow with the granules (E), which should be distributed on the burner evenly and without gaps. Finish off with the fibres (D), which should be stretched along the line of fire. Note the fibres and granules must not touch the filament (see: page 11)
Glass assembly 
Firstly, put the ceramic logs (C) on the burner (optional). Follow with the granules (E), which should be distributed on the burner evenly and without gaps. Finish off with the fibres (D), which should be stretched along the line of fire. Note the fibres and granules must not touch the filament (see: page 11).

Firstly, put the white stones (H) on the burner (optional). Follow with the granules (E), which should be distributed on the burner evenly and without gaps. Finish off with the fibres (D), which should be stretched along the line of fire. Note the fibres and granules must not touch the filament (see: page 11).

OVERVIEW

  1. Filament
  2. Burner
  3. Device surface
  4. Control pane
  5. Cap with a pumping hose
  6. Fuel container

Overview

  1. ECO mode
  2. Flame ignition / flame extinguishing
  3. Service socket
  4. Control diodes

Diodes OFF
Diodes ON
Blinking diodes

REPLACING FUEL CONTAINER

  1. If the fuel container is empty ( ), unscrew the cap with the pumping hose and remove the container from the holder ( ) (I).
  2. Insert a full fuel container with a cap removed ( ) (II).
  3. Screw the cap with the pumping hose back on (III)

FLAME IGNITION

The green diode (  ) indicates that the device is ready to ignite the flame.
Press and hold START for 3 seconds. Flame ignition will take 2-10 minutes ( ). The smell of ethanol vapours can be present during the ignition. The diode READY off ( ) indicates that the flame has been ignited and the device reached the working temperature

FLAME HEIGHT REGULATION

After 3 min, press ECO to lower the flame (two sound signals). Press ECO again to increase the flame height (one sound signal).
ATTENTION! In case the device temperature is too high, the flame will be automatically lowered (ECO) and the height regulation blocked. If the temperature keeps increasing, the device will be turned off.

FLAME EXTINGUISHING

Press STOP to extinguish the flame (sound signal + ).
You can ignite the flame again when the device is cooled – the green diode READY ( ).

FAST START

The FAST START offers faster flame ignition (when the device is ready ( ), the power consumption is 60 W higher). The function is enabled by default.
To disable FAST START, press and hold ECO for 10 seconds (four sound signals). To enable the function, press and hold ECO for 10 seconds (two sound signals).

TROUBLESHOOTING

Some alarms are accompanied by a sound signal. Press START/STOP to mute.

Lp| DIODES| SOLUTION
(contact the Service Department if the solution does not eliminate the error)
---|---|---
1|

| The device is being cooled. Wait for the green diode .
2| | The device run out of fuel while operating. The device is being cooled. Wait for the red diode to turn off. Refill the tank.
3| | An internal fuel spill occurred. Disconnect the pump. Wipe the visible liquid and wait for min. 1 hour. Press and hold ECO on the control panel for 10 seconds. If the error is not eliminated, wait for min. 24 hours.
If the error occurred during flame ignition, it means that the ignition time has been exceeded. Press and hold ECO on the control panel for 10 seconds.
4| | Device error. Press and hold ECO on the control panel for 10 seconds.
5| | Tank overfilled. Contact the Service Department.
6| | Room temperature too low (<10 c) or device error. Increase the room temperature .
press and hold ECO on the control panel for 10 seconds .wait for the green diode
7| | Device overheat. Please contact service department.

FUEL – Use only fuels consisting of 95-96,6% ethanol by volume. FANOLA® is the recommended fuel. Do not use gel, thick and viscous fuels or fuels of improper electric conductivity. The values must be compliant with those of
FANOLA®. Other fuels, such as dehydrated ethanol (i.e. consisting of more than 96,6% by volume ethanol) will cause a device error and loss of the guarantee. Fuels consisting of 100% by volume ethanol will damage the device.
CLEANING – Clean with a damp cloth and delicate detergents, only when the device is turned off and cooled.
SERVICE – Keep the provided USB cable for service. Reach out to us at service@planikafires.com.