The product is a decorative device creating real fire.
Read the included documentation prior to installing and operating the device.
Consult the local regulations for fireplaces.
- For indoor use only. Do not use in temperatures below 10°C.
- Do not use the device in the area smaller than 41 m3
- Room air exchange rate – min. 1/h.
- Do not use the device in humid and drafty conditions.
- Do not cover top ventilation openings of the device.
- No heat-sensitive and flammable objects can be placed within a 1 meter radius from the device.
- There must be a CO2 or dry powder fire extinguisher nearby the device.
- Keep children, animals and any unauthorized persons away from the device.
- Keep the packaging and manuals for future use.
- Do not turn on the device in case of fuel spill.
- Do not interfere in the fuel tank when the device is operating.
- Do not interfere in the device construction.
- Do not touch the filament and other hot elements.
- Do not transport the device if fueled.
- Do not leave an operating device unattended.
- For the first few hours of use, there may be a distinct scent of paint
Selected installation options
Connection to chimney flue forbidden
Glass assembly
N Do not cover top ventilation openings of the device.
Follow with the granules (E), which should be distributed on the burner evenly
and without gaps. Finish off with the fibres (D), which should be stretched
along the line of fire. Note the fibres and granules must not touch the
filament (see: page 11)
Firstly, put the ceramic logs (C) on the burner (optional). Follow with the
granules (E), which should be distributed on the burner evenly and without
gaps. Finish off with the fibres (D), which should be stretched along the line
of fire. Note the fibres and granules must not touch the filament (see: page
11).
Firstly, put the white stones (H) on the burner (optional). Follow with the granules (E), which should be distributed on the burner evenly and without gaps. Finish off with the fibres (D), which should be stretched along the line of fire. Note the fibres and granules must not touch the filament (see: page 11).
OVERVIEW
- Filament
- Burner
- Device surface
- Control pane
- Cap with a pumping hose
- Fuel container
- ECO mode
- Flame ignition / flame extinguishing
- Service socket
- Control diodes
Diodes OFF
Diodes ON
Blinking diodes
REPLACING FUEL CONTAINER
- If the fuel container is empty ( ), unscrew the cap with the pumping hose and remove the container from the holder ( ) (I).
- Insert a full fuel container with a cap removed ( ) (II).
- Screw the cap with the pumping hose back on (III)
FLAME IGNITION
The green diode ( ) indicates that the device is ready to ignite the flame.
Press and hold START for 3 seconds. Flame ignition will take 2-10 minutes (
). The smell of ethanol vapours can be present during the ignition. The diode
READY off ( ) indicates that the flame has been ignited and the device reached
the working temperature
FLAME HEIGHT REGULATION
After 3 min, press ECO to lower the flame (two sound signals). Press ECO again
to increase the flame height (one sound signal).
ATTENTION! In case the device temperature is too high, the flame will be
automatically lowered (ECO) and the height regulation blocked. If the
temperature keeps increasing, the device will be turned off.
FLAME EXTINGUISHING
Press STOP to extinguish the flame (sound signal + ).
You can ignite the flame again when the device is cooled – the green diode
READY ( ).
FAST START
The FAST START offers faster flame ignition (when the device is ready ( ), the
power consumption is 60 W higher). The function is enabled by default.
To disable FAST START, press and hold ECO for 10 seconds (four sound signals).
To enable the function, press and hold ECO for 10 seconds (two sound signals).
TROUBLESHOOTING
Some alarms are accompanied by a sound signal. Press START/STOP to mute.
Lp| DIODES| SOLUTION
(contact the Service Department if the solution does not eliminate the error)
---|---|---
1|
| The device is being cooled. Wait for the green diode .
2| | The device run out of fuel while operating. The device is being cooled.
Wait for the red diode to turn off. Refill the tank.
3| | An internal fuel spill occurred. Disconnect the pump. Wipe the visible
liquid and wait for min. 1 hour. Press and hold ECO on the control panel for
10 seconds. If the error is not eliminated, wait for min. 24 hours.
If the error occurred during flame ignition, it means that the ignition time
has been exceeded. Press and hold ECO on the control panel for 10 seconds.
4| | Device error. Press and hold ECO on the control panel for 10 seconds.
5| | Tank overfilled. Contact the Service Department.
6| | Room temperature too low (<10 c) or device error. Increase the room
temperature .
press and hold ECO on the control panel for 10 seconds .wait for the green
diode
7| | Device overheat. Please contact service department.
FUEL – Use only fuels consisting of 95-96,6% ethanol by volume. FANOLA®
is the recommended fuel. Do not use gel, thick and viscous fuels or fuels of
improper electric conductivity. The values must be compliant with those of
FANOLA®. Other fuels, such as dehydrated ethanol (i.e. consisting of more
than 96,6% by volume ethanol) will cause a device error and loss of the
guarantee. Fuels consisting of 100% by volume ethanol will damage the device.
CLEANING – Clean with a damp cloth and delicate detergents, only when the
device is turned off and cooled.
SERVICE – Keep the provided USB cable for service. Reach out to us at